Laserfiche WebLink
M. <br />w <br />J <br />Y <br />U_ <br />z <br />Y <br />O <br />m <br />0 <br />w <br />Q <br />cn <br />H <br />U) <br />p <br />I <br />M <br />lt') <br />N <br />O <br />N <br />N <br />N <br />W <br />H <br />z <br />a <br />cn <br />p <br />GENERAL NOTES SYSTEM DESCRIPTION / SCOPE OF WORK SYMBOL KEY <br />OCCUPANCY TYPE: 1-2 INSTITUTIONAL GROUP <br />1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF <br />CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES <br />SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. <br />SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED <br />2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR <br />DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT <br />PROVIDE AND INSTALL A NEW AUTOMATIC AND MANUAL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS. <br />TO IMPAIR THE CONSTRUCTION SCHEDULE. <br />3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING <br />ALL WIRING TO BE CLASS B. WIRING IS STYLE Y FOR NOTIFICATION APPLIANCE CIRCUITS, STYLE B FOR INITIATING DEVICE CIRCUITS, <br />AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY <br />AND STYLE 4 FOR SIGNALING LINE CIRCUITS. <br />AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. <br />4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR <br />AUTOMATIC FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY AND TROUBLE SIGNALS TO AN APPROVED SUPERVISING <br />INSTALLATION. <br />STATION. THE SUPERVISING STATION SHALL BE LISTED AS EITHER UUFX OR UUJS UNDERWRITERS LABORATORY OR SHALL MEET THE <br />5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A <br />REQUIREMENTS OF FACTORY MUTUAL RESEARCH APPROVAL STANDARD 3011. SUPERVISION OF SYSTEM AND LEASED TELEPHONE LINES <br />BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK -ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE <br />SHALL BE ARRANGED BY THE OWNER. <br />ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE <br />PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. <br />6. UPDATE THE AS -BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS -BUILT DRAWING SET TO <br />SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. <br />7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. <br />8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. <br />9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO <br />PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE <br />FIRE ALARM INSTALLER. <br />10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF <br />ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. <br />11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND <br />NON -POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS AND NEC. <br />FIRE ALARM APPLICABLE CODES & STANDARDS <br />12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). <br />13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE <br />ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON -POWER LIMITED WIRE. <br />14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE <br />FLORIDA FIRE PREVENTION CODE, 5th EDITION (2014) <br />FPLP. <br />15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED <br />LIFE SAFETY CODE (NFPA 101, 2012 EDITION) <br />IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. <br />16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET <br />LOCATIONS. <br />NATIONAL FIRE ALARM CODE (NFPA 72), 2010 EDITION <br />17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE <br />WITH NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. <br />FLORIDA BUILDING CODE, 2014 EDITION <br />18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. <br />19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. <br />NATIONAL ELECTRICAL CODE (NEC, NFPA 70), 2011 EDITION <br />20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. <br />21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. <br />22. MAINTAIN 40 PERCENT MAXIMUM CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. <br />23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING <br />CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO <br />STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. <br />JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. <br />CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. <br />WIRE SCHEDULE <br />ABBREVIATIONS LEGEND <br />AC = ABOVE CEILING HT = HEIGHT <br />C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING <br />FIRE ALARM WIRE LIST <br />CIRCUIT DESCRIPTION <br />RISER RATED: FPLR <br />SINGLE CONDUCTOR(THHN,TFFN) <br />PLENUM RATED: FPLP <br />D <br />DOOR HOLDER CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE <br />2 CONDUCTOR TWISTED AREA=0.0380 SO. INCH AREA=0.0333 SQ. INCH <br />PAIR 14 AWG SOLID ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER <br />FA-1402C-1-1N-03-BX :AREA=0.0097 SO. INCH (EACH): FA-1 402C-1 -2N-03 <br />K <br />REMOTE TEST SWITCH/ SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE <br />LED CIRCUIT - (2) 2 AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH <br />CONDUCTOR 14 AWG ANIXTER PART NUMBER :(4) #14 AWG : ANIXTER PART NUMBER <br />SOLID FA-1402C-1-1N-03-BX :AREA=0.0097 SQ. INCH (EACH): FA-1402C-1-2N-03 <br />M <br />MAPNET/IDNET CIRCUIT SG ANIX./PAIGE 740215 SG ANIX./PAIGE 740214L <br />1 PAIR 18 AWG TWISTED AREA=O. 196 SQ. INCH AREA=0.0196 SQ. INCH <br />OVERALL SHIELD ANIXTER PART NUMBER ANIXTER PART NUMBER <br />T740215 FAMC-1802C-1-2S-03135 <br />P <br />POWER CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE <br />2 CONDUCTOR AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH <br />14 AWG SOLID (SUBSCRIPT: ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER <br />"r' IF RESETTABLE) FA-1402C-1-1N-03-BX :AREA=0.0097 SQ. INCH (EACH): FA-1 402C-1 -2N-03 <br />R <br />RELAY CIRCUIT SG ANIX./PAIGE 454718ARE: SG ANIX./PAIGE 454719ARE <br />2 CONDUCTOR AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH <br />14 AWG SOLID ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER <br />FA-1402C-1-1N-03-BX :AREA=0.0097 SQ. INCH (EACH): FA-1 402C- 1 -2N-03 <br />S <br />AUDIO CIRCUIT SG ANIX./PAIGE 454722ARE SG ANIX./PAIGE 454717ARE <br />AREA=0.0204 SQ. INCH <br />1 PAIR 18 AWG TWISTED AREA=0.0165 SO. INCH <br />OVERALL SHIELD ANIXTER PART NUMBER ANIXTER PART NUMBER <br />FA-1802C-1-1S-03-BX FA-1802C-1-2S-03-BX <br />V <br />VISUAL/SIGNAL CIRCUIT SG ANIX./PAIGE 454718ARE: SG ANIX./PAIGE 454719ARE <br />2 CONDUCTOR 14 AWG AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH <br />SOLID ANIXTER PART NUMBER : (2) #14 AWG ANIXTER PART NUMBER <br />FA-1402C-1-1N-03-BX :AREA=0.0097 SO. INCH (EACH): FA-1402C-1-2N-03 <br />CONDUIT SIZE <br />CONDUCTOR AREA <br />CONDUIT SIZE <br />CONDUCTOR AREA <br />1/2" <br />0.12 SQ INCH * <br />1-1/4" <br />0.60 SQ INCH * <br />3/4" <br />0.21 SQ INCH * <br />1-1/2" <br />0.82 SQ INCH * <br />1 " <br />0.34 SQ INCH * <br />2" <br />1.34 SQ INCH * <br />* 40% FILL PER N.E.C. <br />THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL <br />CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE <br />SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS <br />CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT <br />DESIGN OF THIS SYSTEM INSTALLATION. <br />REFERENCE https://www.anixter.com/customer/tycofs FOR SG ANIXTER CABLE DATA <br />E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM <br />RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM <br />RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM <br />RL = RELOCATED DEVICE N/A = NOT APPLICABLE <br />RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER <br />NDU = NETWORK DISPLAY UNIT <br />WP = WEATHERPROOF NEC = NATIONAL ELECTRICAL CODE <br />XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION <br />H = HIGH HUMIDITY NIC = NOT IN CONTRACT <br />AFF = ABOVE FINISHED FLOOR NPU = NETWORK PROCESSING UNIT <br />AHJ = AUTHORITY HAVING JURISDICTION NTS = NOT TO SCALE <br />ALM = ALARM PAP = PRE -ACTION PANEL <br />ANN = ANNUNCIATOR SCC = STATUS COMMAND CENTER <br />BMS = BUILDING MANAGEMENT SYSTEM SLC = SIGNALING LINE CIRCUIT <br />CBC = CALIFORNIA BUILDING CODE SMK = SMOKE <br />CD = (eg. 15CD) CANDELA SUPV = SUPERVISORY <br />FIRE ALARM SYMBOLS LEGEND <br />SYMBOL <br />DESCRIPTION <br />MODEL# <br />COMMONLY USED BACKBOX, REFER <br />TO DATA SHEET FOR OTHER OPTIONS <br />XPDR <br />FIRE ALARM TRANSPONDER PANEL <br />SIMPLEX 4100-9601 <br />SUPPLIED BY SIMPLEXGRINNELL <br />W / 25AH BATTERY SET <br />SIMPLEX 2081-9287 <br />(REFER TO MOUNTING DETAIL FOR SPECIFIC DIMENSIONS) <br />NAC EXTENDER PANEL <br />F_NA_C_j <br /># DESIGNATES THE NAC PANEL NUMBER <br />SIMPLEX 4009-9201 <br />SUPPLIED BY SIMPLEXGRINNELL <br />W / 6.2AH BATTERY SET <br />SIMPLEX 2081-9272 <br />�F <br />MANUAL PULL STATION, ADDRESSABLE <br />SIMPLEX 4099-9004 <br />SINGLE GANG BOX 2 1/2" DEEP <br />SMOKE SENSOR / BASE <br />SIMPLEX 4098-9714 <br />0 <br />SIMPLEX 4098-9792 BASE <br />4. OCTAGONAL BOX 1 1/2" DEEP <br />HEAT SENSOR / BASE <br />SIMPLEX 4098-9733 <br />SIMPLEX 4098-9792 BASE <br />4- OCTAGONAL BOX 1 1/2" DEEP <br />DUCT SMOKE SENSOR <br />SIMPLEX 4098-9756 <br />MOUNT TO DUCTWORK <br />OP <br />ENCAPSULATED RELAY <br />SIMPLEX 4098-9843 <br />SINGLE GANG BOX 2 1/8" DEEP W/COVER <br />(APOLLO AMERICA INC PAM-SD) <br />❑X <br />REMOTE TEST STATION W/ LED AND KEY SWITCH <br />SIMPLEX 2098-9806 <br />SINGLE GANG BOX 2 1/2" DEEP <br />O <br />INDIVIDUAL ADDRESSABLE MODULE <br />SIMPLEX 4090-9001 <br />SINGLE GANG BOX 2 1/2- DEEP WITH COVER <br />RELAY IAM <br />SIMPLEX 4090-9002 <br />4" SQUARE BOX 2 1/8" DEEP W/TWO GANG COVER <br />® <br />TRACK MOUNTED SINGLE RELAY SPDT W/ ENCLOSURE <br />SIMPLEX 2088-9008 <br />SUPPLIED W/ ENCLOSURE <br />(APOLLO AMERICA INC MR-101/C) <br />WALL MOUNT MULTI -CANDELA STROBE ONLY RED <br />SIMPLEX 4906-9101 <br />4" SQUARE BOX 1 1/2" DEEP <br /># =CANDELA RATING <br />W/4905-9937 ADAPTER SKIRT WHEN SURFACE MOUNTED <br />WALL MOUNT MULTI -CANDELA SPEAKER/STROBE RED <br />SIMPLEX 4906-9151 <br />4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" EXTENSION RING <br /># =CANDELA RATING, #W = SPEAKER TAP **USE 70 VOLT TAP** <br />W/4905-9946 ADAPTER SKIRT WHEN SURFACE MOUNTED <br />CEILING MOUNT MULTI -CANDELA SPEAKER/STROBE WHITE <br />SIMPLEX 4906-9154 <br />4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" EXTENSION RING <br />C <br /># =CANDELA RATING, #W = SPEAKER TAP **USE 70 VOLT TAP** <br />Q <br />DOOR HOLDER <br />RSG/AAMES DH24120FPC <br />SINGLE GANG BOX 2" DEEP <br />Q2 �- <br />SMOKE DAMPER <br />SUPPLIED BY OTHERS <br />SUPPLIED BY OTHERS <br />FS-S-pl <br />SURGE SUPPRESSOR <br />DITEK DTK-120HW <br />SEE DATA SHEET <br />JB <br />JUNCTION/PULL BOX <br />SUPPLIED BY OTHERS <br />SUPPLIED BY OTHERS <br />END -OF -LINE RESISTOR 3.3K (EOL) <br />SIMPLEX 4081-9002 <br />Aw <br />END -OF -LINE RESISTOR 4.7K (EOL) <br />SIMPLEX 4081-9003 <br />END -OF -LINE RESISTOR 6.8K (EOL) <br />SIMPLEX 4081-9004 <br />END -OF -LINE RESISTOR 10K (EOL) <br />SIMPLEX 4081-9008 <br />CSFM = CALIFORNIA STATE FIRE MARSHAL TAC = TRUEALERT ADDRESSABLE CONTROLLER <br />DET = DETECTOR TRBL = TROUBLE <br />DGP = DATA GATHERING PANEL TS = TAMPER SWITCH <br />EOL = END OF LINE TYP = TYPICAL <br />EPO = EMERGENCY POWER OFF UON = UNLESS OTHERWISE NOTED <br />FACP = FIRE ALARM CONTROL PANEL VCC = VOICE COMMAND CENTER <br />FATC = FIRE ALARM TERMINAL CABINET VT = VALVE TAMPER <br />FBO = FURNISHED BY OTHERS WF = WATER FLOW <br />FCC = FIRE COMMAND CENTER W = (eg. 1/2W) WATT <br />FAA = FIRE ALARM ANNUNCIATOR W/ = WITH <br />FTR = FIRE ALARM TRANSPONDER W/O = WITH OUT <br />FSD = FIRE SMOKE DAMPER <br />DEVICE ADDRESSING LEGEND SEQUENCE OF OPERATION <br />CONTROL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL <br />ADDRESSABLE CARD (IDNEr OR MAPNE) J <br />DEVICE ADDRESS �Q c,�Q��QN p�y�`�y���,�P\o�Pp� P�o��o� <br />M 2 -1 <br />Gj o� �O o� �� o� �� Q�P Jp�O \��0� <br />ADDRESSABLE DEVICES NUMBERING<11 <br />SYSTEM INPUTS <br />A B C I D I E FIG]HIIIJIKILIMI N 1 0 1 P I Q I R I S I T I U I V I W I X I Yj Z I AA_LABj AC I AD I AE I AF I AG I AH I Al I AJ REMARKS <br />SPEAKER CIRCUIT r DEVICE DESIGNATOR <br />S2-11 <br />SPEAKER DEVICE <br />CIRCUIT DESIGNATOR <br />V=VISUAL OR A/V, H=AUDIBLE ONLY) <br />r DEVICE DESIGNATOR <br />V2-1 <br />VISUAL, AUDIBLE OR A/V DEVICE <br />SMOKE1• 1 1• <br />©MANUAL <br />PULL STATION00----000-00-------------�----------© <br />©HEAT <br />SENSOR/DETECTOR <br />0 <br />1 1 • 1 1- <br />© <br />MAIN FLR. ELEV. LOBBY1 DETECTOR <br />1 • 1:: 1 1 1 • <br />00����000�00���0�0�0������������00��� <br />0 <br />1 • MECH. • 11 DETECTOR <br />0 <br />1- ROOM DETECTOR <br />M­ELEvAToR <br />SHAFT HEAT DETECTOR <br />m <br />ELEVATOR SHAFT SMOKEDETECTOR <br />MELEVATOR <br />POWER 1 1' <br />M-FIRE <br />ALARM AC POWERFAILUREM <br />FIRE ALARM SYSTEM LOW BATTERY <br />M <br />OPEN CIRCUIT OR GROUND FAULT <br />IN <br />CLASS B NOTIFICATION CIRCUIT (NAC) - SHORT <br />In <br />mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm <br />m <br />mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm <br />m <br />mmmmmmmmmmmmmmmmmmmmmMMMMMMMMMMMMMMMm <br />® <br />mmmmmmmmmmmmmmmmmmmmmMMMMMMMMMMMMMMM® <br />® <br />------------------------------------m <br />No <br />------------------------------------® <br />m <br />mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm <br />® <br />------------------------------------® <br />® <br />------------------------------------m <br />® <br />------------------�mmmmm------mmmmmm <br />®• <br />------------------------------------m <br />® <br />------------------------------------® <br />0 <br />------------------------------------o <br />® <br />mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm® <br />® <br />------------------------------------E <br />AIBICIDIEIFIGIHI I IJI-KI-L W N I I P I Q-1- RYS-1 T I U I V I W I X I Y I Z I AA I AB I AC I AD I AE I AF I AG LAH AI AJ <br />CURTIS ENGINEERING SERVICE, LLC - CA#31 61 <br />JAMES M. CURTIS, P.E. - PE#37912 <br />29775 BAYHEAD ROAD <br />DADE CITY, FLORIDA 33523 <br />DEL EGA TED ENGINEER OF RECORD <br />Digitally signed S01'"1111'i11f <br />by James Curtis •� <br />N. • . <br />Date: <br />OF <br />2016.07.22 " ,•., �' <br />•!lOR1vlk- <br />'09:25:32 -04'00 'QN"'-``��� <br />�j�+1►I�i��i <br />C*C* <br />�� <br />C9Cp <br />c')00 <br />04 <br />N W <br />W Z <br />�o� <br />\ <br />cam <br />LU <br />1� <br />Z N <br />W o0 <br />N <br />N <br />WMM <br />v <br />zwui <br />�CLU3 <br />c <br />U) <br />Z <br />0 <br />/ j <br />0 = <br />Z <br />LU <br />00- <br />LU <br />� N <br />0 -� <br />Ax <br />W <br />Z 0- <br />0 cn <br />0 <br />VJ <br />Z <br />0- o <br />W W <br />0 <br />0 I <br />LU LL <br />z <br />O <br />F- <br />L) <br />U <br />W <br />0 <br />Y <br />U <br />0 <br />U <br />W <br />Q <br />O <br />LU <br />=3 W <br />U 2 <br />r <br />NT <br />CM <br />cM <br />C Q <br />fir- 0 <br />Qw <br />0 <br />___I LJL <br />U) O J <br />om <br />Q J = <br />� O = <br />LL7 <br />LLM O11`�_ N <br />DRAWN BY: B. KNICKLE <br />CHECKED BY: F. REINHART <br />ISSUE DATE: 7/19/16 <br />JOB #: 292415807 <br />PROJECT #: 292:993523001 <br />SIMPLEXGRINNELL © 2016 <br />SYSTEM: <br />FIRE ALARM SYSTEM <br />SHEET: <br />GENERAL INFORMATION <br />FA-002 <br />