Laserfiche WebLink
0-1 <br />3 ■ 4 ■ 5 ■ 6 ■ 7 ■ 8 ■ 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ 16 ■ 17 ■ 18 <br />■ 19 ■ 20 <br />R <br />■ <br />P <br />■ <br />0 <br />■ <br />N <br />i <br />I <br />■ <br />M <br />1 ■ <br />I <br />L <br />■ <br />K <br />■ <br />J <br />■ <br />H <br />1 <br />I <br />■ <br />1 <br />G <br />I <br />I <br />■ <br />I <br />F <br />■ <br />E <br />■ <br />D <br />1 <br />ai ■ <br />I Y <br />I NrN <br />LL <br />H <br />C <br />a <br />w <br />oc <br />U_ <br />c <br />I � <br />� o ■ <br />w <br />a. <br />m <br />N <br />0) <br />� B <br />Ln <br />T <br />0 <br />J <br />N <br />ac ■ <br />to U <br />N <br />CL <br />U r <br />I� M <br />'Ic N A <br />Q M <br />coN <br />O ti <br />c <br />7 <br />U <br />L <br />m <br />a <br />0 <br />r� <br />-�- <br />1 <br />■ 2 <br />■ <br />° <br />4 < 4 <br />a ° <br />a <br />a 4 ° 4 <br />Q 4 <br />d a 4 <br />° <br />a 4 <br />CONCRETE FASTENER <br />(U.L. LISTED OR F.M. APPROVED) <br />BRANCH LINE <br />ALL THREAD ROD <br />V NIPPLE <br />1" 900 ELL - 1" 900 ELL <br />1"DROP <br />REDUCER <br />CEILING <br />PIPE HANGER RING <br />(U.L. LISTED OR F.M. APPROVED) <br />SPRINKLER HEAD <br />SWING JOINT <br />qR <br />HANGER -CONCRETE <br />No Scale <br />No Scale <br />System No. W-L-1001 <br />(Formerly System No. 147) <br />F Rating-1, 2, 3 and 4 Hr (See Items 2 and 3) <br />TOP BEAM CLAMP <br />T Ratings--0, 1, 2, 3, and 4 Hr (See Items 2 and 3) <br />(UL LISTED OR FM APPROVED) <br />L Rating at t--less than 1 CFM/sq ft <br />L Rating At 400 F--le _q khan 1 CFM/sq ft <br />1A <br />ALL THREAD ROD <br />LZI <br />O <br />PIPE HANGER RING <br />(UL LISTED OR FM APPROVED) <br />QAA <br />2 <br />1B <br />SECTION A -A <br />1. Wall Assembly --The 1, 2, 3 or 4 hr fire -rated gypsum wallboard/stud <br />wall assembly shall be constructed of the materials and in the manner <br />described in the individual U300 or U400 Series Wall or Partition Designs <br />in the UL Fire Resistance Directory and shall include the following <br />construction features: <br />HANGER - STEEL <br />A. Studs --Wall framing may consist of either wood studs (max 2 h fire <br />No Scale <br />rated assemblies) or steel channel studs. Wood studs to consist of <br />nom 2 by 4 in. lumber spaced 16 in. OC with nom 2 by 4 in. lumber <br />end plates and cross braces. Steel studs to be min 3-5/8 in. wide by <br />1-3/8 in. deep channels spaced max 24 in. OC. <br />B. Wallboard, Gypsum *--Nom 1/2 or 5/8 in. thick, 4 ft. wide with <br />square or tapered edges. The gypsum wallboard type, thickness, <br />number of layers, fastener type and sheet orientation shall be as <br />specified in the individual U300or U400 Series Design in the UL Fire <br />Resistance Directory. Max diam of opening is 13-1/2 in. <br />2. Pipe or Conduit--Nom 12 in. diam (or smaller) Schedule 10 (or heavier) <br />steel pipe, nom 12 in. diam (or smaller) service weight (or heavier) cast <br />iron soil pipe, nom 12 in. diam (or smaller) Class 50 (or heavier) ductile <br />iron pressure pipe, nom 6 in. diam (or smaller) steel conduit, nom 4 in. <br />diam (or smaller) steel electrical metallic tubing, nom 6 in. diam (or <br />smaller) Type L or (or heavier) copper tubing or nom 1 in. diam (or <br />smaller) flexible steel conduit. When copper pipe is used, max F Rating <br />1"90• ELL 1"900 ELL <br />of firestop system (Item 3) is 2 h. Steel pipes or conduits larger than <br />nom 4 in. diam may only be used in .calls constructed using steel <br />channel studs. A max of one pipe or conduit is permitted in the <br />firestop system. Pipe or conduit to be installed near center of stud <br />cavity width and to be rigidly supported on both sides of wall <br />assembly. <br />3. Fill, Void or Cavity Material*--Caulk--Caulk fill material installed to <br />completely fill annular space between pipe or conduit and gypsum <br />wallboard and with a min 1/4 in. diam bead of caulk applied to perimeterBRANCH <br />LINE <br />of pipe or conduit at its egress from the wall. Caulk installed symmetrically <br />1x1l2 REDUCER <br />on both sides of wall assembly. The hourly F Rating of the firestop system <br />is dependent upon the hourly fire rating of the wall assembly in which it <br />1" DROP <br />is installed, as shown in the following table. The hourly T Rating of the <br />i <br />CEILING <br />firestop system is dependent upon the type or size of the pipe or conduit <br />and the hourly fire rating of the wall assembly in which it is installed, as <br />tabulated below: <br />Max pipe Annular F T <br />or Conduit Space Rating Rating <br />Diam In. In. Hr. Hr. <br />1 3 to 3/16 1 or 2 0+, 1 or 2 <br />1 1/4to112 3or4 3or4 <br />4 0 to 1-112 1 or 2 0 <br />SPRINKLER HEAD <br />6 1 /4 to 1/2 3 or 4 0 <br />12 3/16 to 3/8 1 or 2 0 <br />+When copper is used, T Rating is Oh. <br />Minnesota Mining & Mfg. Co. --Types FB-2000, FB-2000+. <br />*Bearing the UL Classification Marking <br />WALL - DRYWALL - PIPE-1/2/3/4 HR <br />5 <br />RETURN BEND <br />3 <br />System No. W-L-1001 <br />-No Scale <br />3 ■ 4 ■ 5 ■ 6 ■ 7 ■ 8 ■ 9 ■ 10 ■ 11 <br />SYMBOL <br />DESCRIPTION <br />1. <br />FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13 AND ALL APPLICABLE STATE CODES. <br />oE OR oa <br />- CONTROL VALVE w/TAMPER SWITCH <br />2. <br />FINAL INSPECTION AND APPROVAL BY LOCAL FIRE MARSHAL AND ARCHITECT/ENGINEER. <br />- U/G GATE VALVE <br />3. <br />SPRINKLER SHOP DRAWINGS AND MATERIAL SUBMITTALS SHALL BE SUBMITTED TO THE <br />n <br />- FIRE VALVE CABINET <br />ARCHITECT/ENGINEER AND STATE FIRE MARSHAL AND SHALL BE APPROVED PRIOR TO ANY <br />INSTALLATION. <br />- NEW SPRINKLER PIPING <br />4. <br />PIPE ROUTING SHOWN; IS SCHEMATIC ONLY. IT IS THE RESPONSIBILITY OF THIS <br />CONTRACTOR TO PROVIDE ANY ADDITIONAL OFFSETS REQUIRED FOR PROPER <br />- <br />- EXISTING SPRINKLER PIPING <br />INSTALLATION AND COORDINATION WITH OTHER TRADES. <br />-------- <br />- DEMOLISHED SPRINKLER PIPING <br />5. <br />PIPING IN AREAS WITH EXPOSED STRUCTURE SHALL BE INSTALLED AS HIGH AS POSSIBLE <br />TO ALLOW THE OWNER MAXIMUM USE OF THE SPACE. <br />2112" <br />- PIPE SIZE <br />6. <br />REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING DESCRIPTIONS AND <br />HEIGHTS. <br />2112" <br />- PIPE SIZE AND LENGTH <br />7. <br />SPRINKLERS ARE TO BE COORDINATED WITH ALL DIFFUSERS, SPEAKERS, LIGHTING <br />3-0 <br />FIXTURES AND CEILING SYSTEMS. SPACING OF SPRINKLERS SHALL BE IN ACCORDANCE <br />WITH NFPA 13 AND THE LISTING OF THE SPRINKLER. <br />-CONTROL VALVE W/ TAMPER SWITCH <br />8. <br />SPRINKLER LOCATIONS SHALL BE CENTERED IN THE TILE. PROVIDE ARMOVER OR SWING <br />JOINT AS REQUIRED. <br />-0-4 <br />- 2-1/2" FIRE DEPARTMENT VALVE W/ CAP AND CHAIN <br />9. <br />SPRINKLERS IN ARIE-A0 WITH EXPOSED STRUCTURE (OBSTRUCTED CONSTRUCTION) SHALL <br />BE INSTALLED WITH DEFLECTOR 1" BELOW THE BOTTOM OF THE BEAM (MAXIMUM 22" <br />BELOW ROOF DECK). EXPOSED BAR JOISTS THAT HAVE SPRAY -ON FIRE PROOFING THAT <br />- HYDRAULIC REMOTE AREA <br />MAKES THE JOIST SO' ID SHALL BE TREATED LIKE A BEAM WITH THE SPRINKLERS 1" BELOW <br />THE BOTTOM OF THE I IRE PROOFING. <br />10. <br />SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND <br />�- <br />-KEYNOTE <br />FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL OR <br />EXCEED THE RATING 'DF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS <br />® <br />- HYDRAULIC REFERENCE NODE <br />FOR FINAL FINISHES, <br />11. <br />PROVIDE ACCESS PAiNIELS TO ALL VALVES ABOVE NON -ACCESSIBLE CEILINGS AND CHASES. <br />A# <br />- REVISION REFERENCE <br />e <br />CONNECT TO <br />12. <br />PROVIDE A PERMANENTLY ATTACHED NAME TAG TO THE RISER STATING THE REQUIRED <br />DESIGN CRITERIA FOR EACH HYDRAULICALLY -DESIGNED SYSTEM. <br />- <br />Q <br />- DEMO TO <br />13. <br />PROVIDE SPRINKLERS UNDERNEATH ALL EXPOSED DUCTWORK WHICH IS OVER 48" WIDE <br />AND SPACE HEADS AROUND ALL OBSTRUCTIONS IN ACCORDANCE WITH NFPA 13. HEADS <br />UNDER DUCTS ARE NOT INDICATED ON THE DRAWINGS BUT ARE REQUIRED AND SHALL BE <br />PROVIDED IN ACCORDANCE WITH NFPA 13. SPRINKLER LOCATIONS UNDER DUCTWORK AND <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT <br />AROUND OBSTRUCTIONS SHALL BE GOVERNED BY FINAL INSTALLED LOCATIONS. <br />-, <br />A�' F�O�� <br />14. <br />PROVIDE SPRINKLERS AT THE TOP AND BOTTOM OF ALL STAIRWELLS AND AT THE LANDING <br />OF EACH FLOOR THAT OPENS INTO MORE THAN ONE FIRE ZONE. <br />.......... <br />15. <br />PROVIDE SPRINKLER ;UARDS ON ALL HEADS IN ELECTRIC ROOMS, TELEPHONE ROOMS, <br />ELEVATOR ROOMS, ELEVATOR SHAFTS AND ON ANY HEADS LESS THAN 7-0" ABOVE THE <br />FLOOR. <br />a) <br />THE POINT OF SERVICE AND THE WATER SUPPLY CHARACTERISTIC'S FOR THE FIRE <br />16. <br />IF SYSTEM PRESSURE EXCEEDS 100 PSI PROVIDE HANGERS PER NFPA 13 9.2.3.4. AND <br />PROTECTION SYSTEM IS SHOWN ON THE FIRE PROTECTION SITE PLAN. <br />9.2.3.5.2 THAT PREVENTS UPWARD MOVEMENT OF THE PIPE FOR SPRINKLERS IN THE <br />b) <br />THE FIRE PROTECTION DESIGN, CALCULATIONS, INSTALLATION AND THE ACCEPTANCE TESTING <br />PENDENT POSITION. A MAXIMUM OF 12" FROM THE END SPRINKLER ON A BRANCH LINE AND <br />OF THE FIRE PROTECTION SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 13, 2010 EDITION; THE <br />ALL ARM-OVERS OVEF, 12". <br />FLORIDA BUILDING CODE AND THE FLORIDA FIRE PREVENTION CODE 2014 EDITION AND ALL <br />17. <br />COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) <br />LOCAL CODES REQUIRED BY THE AUTHORITY HAVING JURISDICTION. <br />PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL PANELS <br />c) <br />AREA OCCUPANCIES AND HAZARD CLASSIFICATIONS ARE LISTED IN THE DESIGN CRITERIA <br />UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER ELECTRICAL SHALL BE REROUTED AT <br />NOTE LOCATED ON THE CONTRACT DOCUMENTS. <br />NO ADDITIONAL COST. <br />d) <br />THE FIRE PROTECTION CONTRACTOR SHALL PREPARE AND PROVIDE FIRE PROTECTION SYSTEM <br />18. <br />SPRINKLERS IN EQUIPMENT ROOMS ARE TO BE INTERMEDIATE TEMPERATURE 200°F <br />LAYOUT DOCUMENTS WITH HYDRAULIC CALCULATIONS. FIRE PROTECTION SYSTEM LAYOUT <br />SPRINKLERS PER NFPA 13. <br />DOCUMENTS WITH HYDRAULIC CALCULATIONS SHALL BE SUBMITTED TO THE <br />ARCHITECT/ENGINEER AND THE LOCAL AHJ FOR ACCEPTANCE PRIOR TO PERMITTING. <br />19. <br />WET BULK SUPPLY MAINS AND HOSE SUPPLY MAINS EXPOSED TO THE WEATHER SHALL BE <br />INSULATED AND PROVIDED WITH AN ALUMINUM JACKET. <br />e) <br />SEE SITE PLAN FOR THE CHARACTERISTICS WATER SUPPLY PIPING. <br />20. <br />PROVIDE A TEMPORA.I -Y STANDPIPE SYSTEM WITH FIRE DEPARTMENT CONNECTIONS <br />f) <br />THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE A HYDRANT FLOW TEST AND PERFORM <br />DURING CONSTRUCTION. <br />HYDRAULIC CALCULATIONS FOR PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT <br />DOCUMENTS (WORKING PLANS).------------------------------------ <br />g) <br />ALL SYSTEM CONTROL VALVES SHALL BE PROVIDED WITH TAMPER SWITCHES AND INTERFACE <br />THE ALARM CIRCUIT. <br />- <br />h) <br />THE WATER SUPPLY FOR THE FIRE PROTECTION SYSTEM HAS NOT SHOWN ANY EVIDENCE OF <br />THESE DRAWINGS ARE COMPLETE SPRINKLER DESIGN DRAWINGS FOR REVIEW BYACHA FOR <br />MICROBIAL INDUCED CORROSION (MIC). THE FIRE PROTECTION CONTRACTOR SHALL NOTIFY <br />STAGE III CONSTRUCTION DOCUMENTS. THE LAYOUT OF THE PIPING SYSTEM COMPLETED BY TLC, <br />THE ARCHITECT/ENGINEER OF ANY EVIDENCE OF MIC AND PROVIDE NECESSARY WATER <br />AND ARE IN COMPLIANCE WITH FLORIDA STATUTE 61 G15-32.003 AND-32.004. <br />TREATMENT AS NEEDED TO REDUCE OR ELIMINATE MIC. <br />ENTIRE BUILDING (EXCEPT AS NOTED): <br />i) <br />ALL METERING AND BACK FLOW PREVENTION DEVICES SHALL MEET WITH ALL WATER <br />OCCUPANCY CLASSIFICATION: LIGHT HAZARD <br />PURVEYORS REQUIREMENTS. <br />SYSTEM TYPE: WET PIPE <br />DESIGN DENSITY: .10 GPM/SQ. FT. <br />j) <br />ALL FIRE PROTECTION EQUIPMENT AND COMPONENTS SHALL BE LISTED AND TESTED FOR FIRE <br />HYDRAULIC REMOTE AREA: 1,500 SQ. FT. <br />PROTECTION USE. ALL FIRE PROTECTION EQUIPMENT AND COMPONENTS SHALL BE THE U.L. <br />SPRINKLER ORIFICE SIZE: 1/2" <br />LISTED AND FM APPROVED. <br />DURATION OF SUPPLY: 30 MIN. <br />MAXIMUM COVERAGE/SPRINKLER HEAD. 225 SQ. FT. <br />............. - ..,: <br />�t ��R������ <br />HOSE STREAM ALLr�WANCE• 100 GPM <br />UNLESS OTHERWISE NOTED ALL STORAGE MECHANICAL AND ELECTRICAL ROOMS: <br />. ....... <br />............. <br />....... - --------------------- <br />-------------- <br />OCCUPANCY CLASSIFICATION: ORDINARY HAZARD GROUP I <br />SYSTEM TYPE: WET PIPE <br />DESIGN DENSITY: <br />THE WATER -BASED FIRE PROTECTION SYSTEM HAS BEEN DESIGNED IN COMPLIANCE_ WITH NFPA <br />HYDRAULIC REMOTE AREA: 1,500 SQ. FT. <br />SPRINKLER ORIFI(`E SIZE: 1/2" <br />13-2010, FLORIDA ADMINISTRATIVE CODE 61G15-32, AND THE STATE OF FLORIDA AGENCY FOR <br />DURATION OF SUPPLY: 60-90 MIN. <br />HEALTHCARE ADMINISTRATION (AHCA) AS FOLLOWS: <br />MAXIMUM COVERAGE/SPRINKLER HEAD: 130 SQ. FT. <br />1. <br />THESE DRAWINGS REPRESENT A COMPLETE SPRINKLER DESIGN AS REQUIRED FOR REVIEW BY AHCA <br />HOSE STREAM ALLOWANCE: 250 GPM <br />FOR STAGE III CONSTRUCTION DOCUMENTS, IN CONJUNCTION WITH ASSOCIATED HYDRAULIC <br />CALCULATIONS AND A LAYOUT OF THE PIPING SYSTEM COMPLETED BY TLC, AND ARE THE COMPLETE <br />DESIGN CRITERIA: <br />ENGINEERING DOCUMENTS IN COMPLIANCE WITH FLORIDA ADMINISTRATIVE CODE 61G15-32.003 AND -, <br />32.004. <br />DESIGN OF THE FIRE SUPPRESSION SYSTEM ON THIS PROJECT. THE <br />FOLLOWING PUBLICATIONS SHALL BE USED AS A REFERENCE. CIITY OF .E.EPHYRHILLS <br />2. <br />SUPPLEMENTAL INFORMATION HAS ALSO BEEN PROVIDED HEREIN TO ASSIST AHCA AND OTHER <br />1. NFPA 13, INSTALLATION OF SPRINKLER SYSTEMS, 2010 EDITION PUN EXAMINER o. <br />AUTHORITIES HAVING JURISDICTION (AHJ) IN UNDERSTANDING THE OWNER'S INTENDED USE AND <br />2. NFPA 14, INSTALLATIONS OF STANDPIPES AND HOSE SYSTEMS, 2010 EDITION <br />PROPOSED PROTECTION OF THE BUILDING PURSUANT TO FLORIDA ADMINISTRATIVE CODE 61G15- <br />3. NFPA 20, INSTALLATION OF CENTRIFUGAL FIRE PUMPS, 2010 EDITION <br />32.003 (8) AND AS OUTLINED IN NFPA 13 - 22.1 AS PRELIMINARY PLANS TO PROVIDE A CLEAR <br />4. NFPA 24, PRIVATE FIRESERVICE MAINS AND THEIR APPURTENANCES, 2010 EDITION <br />REPRESENTATION OF THE HAZARD TO BE PROTECTED, THE SYSTEM DESIGN CONCEPT, THE <br />5. FLORIDA FIRE PREVENTION CODE, 2014 EDITION <br />PROPOSED WATER SUPPLY CONFIGURATION, AND BUILDING CONSTRUCTION INFORMATION <br />PERTINENT TO THE SYSTEM LAYOUT AND DETAILING. <br />FIRE SPRINKLER: <br />3. <br />IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE 61 G15-32.004 (4), INSOFAR AS ADDITIONAL <br />THE CONTRACTOR SHALL PREPARE SYSTEM LAYOUT DRAWINGS PER CHAPTER 22, OF NFPA 13 - <br />INFORMATION IS SHOWN IN THESE ENGINEERING DOCUMENTS THAN IS REQUIRED, TLC IS <br />2010 EDITION. THE CONTRACTOR SHALL PERFORM HYDRAULIC CALCULATIONS. CONTRACTOR'S <br />RESPONSIBLE FOR THE TECHNICAL ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE <br />SPRINKLER SYSTEM LAYOUT (SHOP DRAWINGS), HYDRAULIC CALCULATIONS AND MATERIAL <br />CODES, STANDARDS AND SOUND ENGINEERING PRINCIPLES. <br />DATA SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER AND AUTHORITY HAVING <br />JURISDICTION FOR APPROVAL PRIOR TO SYSTEM INSTALLATION. <br />4. <br />SHOP DRAWINGS SHALL BE DEVELOPED AND SUBMITTED BY THE FIRE PROTECTION SUB- <br />CONTRACTOR AS FOLLOWS: <br />STANDPIPE DESIGN CRITERIA: <br />SHALL COr,jPLY WITH <br />A. THE FIRE PROTECTION INSTALLING SUBCONTRACTOR, IN ACCORDANCE WITHTHE FIRE <br />ALL WORK <br />HYDRAULIC DESIGN CRITERIA: AUTOMATIC WET (CLASS 3) PREVAILING CrJi3ES <br />PROTECTION SPECIFICATION SECTIONS, MUST PROVIDE LAYOUT DOCUMENTS OR WORKING <br />FLORIDA BUILDING CODE. <br />PLANS (SHOP DRAWINGS) IN COMPLIANCE WITH FLORIDA ADMINISTRATIVE CODE 61G15-32.002 <br />STANDPIPE HYDRAULIC DESIGN CRITERIA: NATIONAL ELECTRIC CoUl,- A' � <br />AND NFPA 13 CHAPTER 22 FOR TLC REVIEW. <br />�y of Z>~PHYRHILLS OR , <br />HYDRAULIC CALCULATIONS AND PIPE SIZES FOR EACH STANDPIPE SHACL�- BE BASED ON PROVIDING <br />B. TLC WILL REVIEW THE SHOP DRAWINGS FOR ACCURACY, DESIGN INTENT AND COMPLIANCE WITH <br />250 GPM AT THE HYDRAULICALLY MOST REMOTE TWO HOSE CONNECTIONS ON THE MOST REMOTE <br />THE REQUIREMENTS OF FLORIDA ADMINISTRATIVE CODE 61 G15 AND NFPA 13. <br />STANDPIPE AND 250 GPM FROM THE MOST REMOTE HOSE CONNECTION ON EACH ADDITIONAL <br />STANDPIPE AT A MINIMUM RESIDUAL PRESSURE OF 100 PSI AT THE HOSE VALVE OUTLET. <br />C. IF THE LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATIONS (ANY DEVIATION FROM THE DESIGN <br />PARAMETERS ESTABLISHED AND DOCUMENTED IN THESE PLANS), THE FIRE PROTECTION SUB- <br />WATER SUPPLY DATA: <br />CONTRACTOR SHALL REIMBURSE TLC ENGINEERING FOR ALL ENGINEERING FEES REQUIRED TO <br />THE CONTRACTOR SHALL PERFORM HYDRANT -FLOW TEST TO VERIFY WATER PRESSURE <br />REVISE THE ENGINEERING DOCUMENTS AND FOR RESUBMISSION TO AHCA AND OTHER AHJ'S. <br />REQUIRED FOR HYDRAULIC CALCULATIONS. <br />D. A COPY OF THE APPROVED SHOP DRAWINGS AND ENGINEERING DOCUMENTS SHALL BE <br />PROVIDED FOR AHJ REVIEW AS REQUIRED FOR PERMITS. <br />THE EXISTING FIRE PROTECTION SYSTEM SHALL REMAIN ACTIVE DURING THE CONSTRUCTION <br />SHEET <br />I DESCRIPTION <br />ISSUED <br />AND INSTALLATION OF THE NEW FIRE SPRINKLER SYSTEM. ONCE THE NEW SYSTEM IS INSTALLED, <br />FP001 <br />GENERAL FIRE PROTECTION INFORMATION <br />Yes <br />CONNECTED TO THE WATER SOURCE, IS TESTED AND ACCEPTED BY THE AHJ THE EXISTING <br />SYSTEM CAN BE DEMOLISHED. THE BUILDING SHALL NOT BE WITH OUT FIRE SPRINKLER <br />FP111 <br />FIRE PROTECTION DEMOLITION PLAN - LEVEL 1 - PHASE 1 <br />Yes <br />PROTECTION AT ANY TIME DURING CONSTRUCTION EXCEPT FOR THE TIME OF CONNECTING THE <br />FP112 <br />FIRE PROTECTION DEMOLITION PLAN - LEVEL 1 - PHASE 2 <br />Yes <br />NEW SYSTEM AND DISCONNECTING THE EXISTING SYSTEM. PROVIDE 72 HOUR NOTICE TO THE <br />OWNER PRIOR TO SYSTEM SHUT DOWNS. COORDINATION WITH THE OWNER PRIOR TO SHUT <br />FP121 <br />FIRE PROTECTION DEMOLITION PLAN - LEVEL 2 - AREA 1 <br />Yes <br />DOWN OF THE EXISTING FIRE SPRINKLER SYSTEM IS REQUIRED TO IMPLEMENT OTHER MEANS OF <br />FIRE SAFETY FOR THE BUILDING. <br />FP122 <br />FIRE PROTECTION DEMOLITION PLAN - LEVEL 2 - AREA 2 <br />Yes <br />FP21 1 <br />FIRE PROTECTION PLAN - LEVEL 1 - PHASE 1 <br />Yes <br />TEMPORARY FIRE PROTECTION: <br />PROVIDE TEMPORARY SPRINKLER HEADS TO PROVIDE COVERAGE IN ALL CONSTRUCTION ZONES <br />FP212 <br />FIRE PROTECTION PLAN - LEVEL 1 - PHASE 2 <br />Yes <br />CREATED BY TEMPORARY CONSTRUCTION BARRIERS INCLUDING CONSTRUCTION FOR ALL <br />FP221 <br />FIRE PROTECTION PLAN -LEVEL 2 -AREA 1 <br />Yes <br />PHASES. <br />FP222 <br />FIRE PROTECTION PLAN -LEVEL 2 -AREA 2 <br />Yes <br />­--------­-------- -------_---------------- ...............������T� F��� �A------------------- <br />................ <br />----------­- - --- - - - ------_------_---F11................ <br />FP301 <br />FIRE PROTECTION RISER DIAGRAM <br />Yes <br />STATIC PRESSURE: 40 PSI FLOW: 1508 GPM DATE: 01/14/2015 <br />RESIDUAL PRESSURE: 30 PSI <br />LOCATION: 7050 GALL BOULEVARD <br />TEST CONDUCTED BY: CINTAS FIRE PROTECTION <br />SYMBOL <br />ORIFICE <br />TEMP <br />RESPONSE <br />K-FACTOR <br />FINISH <br />MODEL <br />STYLE <br />PLATE <br />MFG <br />po <br />1/2" <br />155' F <br />QUICK <br />5.6 <br />BRASS <br />G5-56 <br />CONCEALED <br />WHITE <br />RELIABLE <br />1/2" <br />200° F <br />QUICK <br />5.6 <br />BRASS <br />F1 FIR <br />HORIZONTAL SIDEWALL <br />HEAD GUARD <br />RELIABLE <br />1/2" <br />1550 F <br />- <br />-- <br />-- <br />EXISTING <br />PENDENT <br />- <br />EXISTING <br />0 <br />1/2" <br />155° F <br />QUICK <br />5.6 <br />BRASS <br />F1 FR <br />UPRIGHT <br />HEAD GUARD <br />RELIABLE <br />212' <br />1/2" <br />2120 F <br />QUICK <br />5.6 <br />BRASS <br />F1 FR <br />UPRIGHT <br />HEAD GUARD <br />RELIABLE <br />R <br />■ <br />P <br />/ <br />■ <br />�j"V <br />0 <br />■ <br />k <br />N <br />■ <br />M <br />■ <br />L <br />■ <br />K <br />■ <br />J <br />4; ■ <br />H <br />255 S. Orange Avenue <br />EW Suite 1600 <br />Orlando, FL 32801 <br />Phone: 407-841-9050 ■ <br />ENGINEERING Fax: 407-540-0234 <br />FOR CRCOITECTORE www.tic-engineers.com <br />©Copyright2016 TLC Engineering for Architecture, Inc. <br />COA 15 TLC NO: 115498 <br />SEAL Aaron Lee Johnson, P.E. G <br />Florida License #71576 <br />0 1 6 <br />A� <br />• OF .•w <br />E® F <br />C' •• <br />n <br />®�4414 /DNA1-li o <br />i <br />■ <br />Florida Hospital <br />zephyrhills <br />E <br />ED EXPANSION & ORTHO <br />RENOVATION <br />■ <br />D <br />Hunton •� <br />■ <br />A R C H I T E C T S <br />DATE SUBMISSION NO. C <br />04.15.16 CONSTRUCTION DOCUMENTS <br />■ <br />B <br />■ <br />GENERAL FIRE PROTECTION <br />INFORMATION E <br />PROD. NO. H-15021.00 SHEET A <br />DRAWN J1-1- <br />EPoo1 <br />■ 12 ■ 13 ■ 14 ■ 15 ■ 16 ■ 17 ■ 18 ■ 19 ■ 20 <br />Copyright HuntonBrady Architects P.A. All Rights Reserved. 800 N. Magnolia Ave., Suite 600, Orlando, Florida 32803 (407) 839-0886 (407) 839-1709/Fax www.huntonbrody.com License AAC001744 <br />