RELIABLE F1 FR56 RELIABLE G5-56 <br />STANDARD COVERAGE STANDARD COVERAGE <br />QUICK RESPONSE UPRIGHT QUICK RESPONSE PENDENT <br />(NO ESCUTCHEON) (CONCEALED ESCUTCHEON) <br />SIN# RA1425 SIN# RA3415 <br />FIRE SPRINKLER HEAD DETAIL <br />N.T.S. <br />RELIABLE F1 FR56 <br />STANDARD COVERAGE <br />QUICK RESPONSE HORIZONTAL SIDEWALL <br />(NO ESCUTCHEON) <br />SIN# RA1435 <br />SPRINKLER LEGEND <br />SYMBOL <br />COUNT <br />K- FACTO R <br />SIN # <br />DESCRIPTION <br />0 <br />9 <br />5.6 <br />RA1425 <br />RELIABLE BRASS UPRIGT FIRE SPRINKLER HEAD 155° OR 212' <br />® <br />262 <br />5.6 <br />RA3415 <br />RELIABLE WHITE CONCEALED PENDENT FIRE SPRINKLER HEAD 155° <br />a <br />1 <br />5.6 <br />RA1435 <br />RELIABLE BRASS SIDEWALL FIRE SPRINKLER HEAD 200` <br />TOTAL HEAD COUNT - 272 <br />BASIC PIPE AND FITTING <br />MATERIAL REQUIREMENTS: <br />MINIMUM PIPE SCHEDULE FOR <br />WELD/GROOVED/PLAIN <br />MISCELLANEOUS MATERIAL REQUIREMENTS: <br />END PIPING: <br />❑ SCH. 7 (DYNAFLOW, ETC.) <br />[vrBLACK STEEL PIPE <br />❑ DOMESTIC MATERIAL ONLY <br />E'SCH. 10 <br />❑ GALVANIZED PIPE <br />[DOMESTIC OR FOREIGN MATERIAL ACCEPTABLE <br />❑ SCH. 40 <br />❑ "SEAMLESS" <br />ErMATERIAL TO MEET THE MINIMUM REQUIREMENTS OF NFPA 13 <br />❑ SCH. 80 <br />❑ SHOP PAINTED <br />[MATERIAL TO BE UL LISTED AT A MINIMUM <br />❑ CPVC <br />❑ MATERIAL TO BE UL LISTED & FM APPROVED <br />❑ DRAIN PIPE & FITTINGS TO BE "GALVANIZED" <br />MINIMUM PIPE SCHEDULE FOR <br />THREADED PIPING: <br />❑ GALVANIZED PIPE & FITTINGS REQUIRED FOR EXTERIOR WALL <br />PENETRATIONS & EXTERIOR PIPING RUNS. <br />❑ "THREADABLE" LIGHTWALL <br />EeBLACK STEEL PIPE <br />HANGER MATERIAL <br />Ej�SCH. 40 <br />❑ GALVANIZED PIPE <br />❑ SCH. 80 <br />❑ "SEAMLESS" <br />STANDARD LOOP HANGER RINGS <br />❑ _________ <br />❑ SHOP PAINTED <br />❑ CLEVIS HANGERS REQUIRED <br />❑ ALL THREAD ROD TO 'BLACK' <br />EeALL THREAD ROD TO BE 'CAD PLATED' <br />FITTINGS UTILIZED ON THIS PROJECT: <br />❑ "STAINLESS" HANGER MATERIAL REQUIRED <br />❑ GROOVED (STANDARD TAKEOUT) <br />❑ C.I. SCREWED <br />❑ GROOVED (SHORT RADIUS) <br />[�rD.I. SCREWED <br />❑ GROOVED COUPLINGS (RIGID) <br />❑ M.I. SCREWED (BILK) <br />❑ GROOVED COUPLINGS (FLEXIBLE) <br />❑ M.I. SCREWED (GALV) <br />❑ WELDED OUTLETS <br />❑ FLANGED 125# <br />E�MECHANICAL TEES <br />❑ FLANGED 250# <br />* = SEE MISCELLANEOUS NOTES <br />❑ CPVC <br />"DROP -IN" TYPE ANCHOR IN <br />CLEANLY -DRILLED HOLE (HILTI <br />HDI OR UL LISTED EQUIVALENT) <br />HILTI SIZES LISTED BELOW <br />SWIVEL <br />;ER <br />ALL THREAD ROD SIZES <br />PIPE SIZES 1" - 4" -- ROD SIZE = 3/8" <br />PIPE SIZES 5" - 8" -- ROD SIZE = 1/2" <br />PIPE SUPPORT - TYPE C01 <br />DROP -IN ANCHOR W/ RING HANGER <br />STEEL BAR JOIST <br />CAD PLATED FERROUS <br />ALL -THREAD ROD <br />SEE MINIMUM SIZE <br />REQUIREMENTS BELOW <br />NOTE: <br />BULK HANGER MATERIAL HAS <br />BEEN SENT TO THE JOBSITE. <br />FIELD CUT HANGERS AS <br />NECESSARY. <br />PIPE <br />ALL THREAD ROD SIZES <br />PIPE SIZES 1" - 4" -- ROD SIZE = 3/8" <br />PIPE SIZES 5" - 8" -- ROD SIZE = 1/2" <br />PIPE SUPPORT - TYPE S01 <br />TOP BEAM CLAMP W/ RING HANGER <br />SAMMY SUPER SCREW FOR <br />1/4" PRE -DRILLED CONCRETE, CST 20 (FM <br />HOLE IN CONCRETE APPROVED FOR PIPE SIZES <br />UP TO 4") <br />NOTE: <br />BULK HANGER MATERIAL HAS BEEN <br />SENT TO THE JOBSITE. FIELD CUT <br />HANGERS AS NECESSARY. <br />\3/8" CAD PLATED <br />FERROUS ATR <br />UL LISTED SWIVEL <br />RING HANGER <br />PIPE <br />PIPE SUPPORT <br />SAMMY SUPER SCREW FOR CONCRETE <br />W/ RING HANGER <br />HANGER DETAIL <br />N.T.S. <br />GENERAL NOTES <br />SCOPE OF WORK: <br />TO DESIGN AND RETROFIT THE FIRE SPRINKLER SYSTEM IN ACCORDANCE <br />WITH NFPA 13, 2010 AND LOCAL AUTHORITY. <br />BUILDING HAS AN OPERATIONAL FIRE SPRINKLER SYSTEM. <br />WORK CONSIST OF RELOCATION EXISTING SPRINKLERS TO NEW ROOM <br />LAYOUT, AS SHOWN ON PLANS. <br />NAME OF OWNER: FLORIDA HOSPITAL <br />AREA OF WORK APPROXIMATELY 42,838 SQ. FT. <br />1. ALL UNDERGROUND PIPING IS EXISTING TO REMAIN AS IS <br />UNDISTURBED. <br />2. ALL 1" TO 2" PIPING TO BE BLACK SCHEDULE 40 THREADED AND JOINED <br />BY DUCTILE IRON FITTINGS AND COUPLINGS. <br />3. ALL 22" TO 6" PIPING TO BE BLACK SCHEDULE 10 ROLL GROOVED AND <br />JOINED BY GROOVE TYPE FITTINGS. <br />4. ALL HANGERS AND TRAPEZE ASSEMBLIES SHALL UTILIZE UL/FM LISTED <br />COMPONENTS AND COMPLY WITH NFPA 13 REQUIREMENTS. <br />5. ALL CONTROL VALVES ARE EXISTING TO REMAIN AS IS UNDISTURBED. <br />6. ALL NEW INTERIOR PIPING SHALL BE HYDROSTATICALLY TESTED AS <br />REQUIRED PER NFPA 13 SECTION 24.2.1. <br />7. INSTALL PENDANT SPRINKLER HEADS IN CENTER OF THE CEILING TILE. <br />8. A STOCK OF SPARE SPRINKLER HEADS SHALL BE PROVIDED IN <br />ACCORDANCE WITH NFPA 13. <br />9. MIC (MICRO -BIOLOGICALLY INFLUENCED CORROSION) IS NOT KNOWN <br />TO BE A PROBLEM AT THIS LOCATION. <br />SEE FLOOR PLAN FOR <br />ARM -OVER LENGTHS <br />NE OF EXISTING <br />LINE PIPING <br />SCHEDULE 40 DROP NIPPLE <br />w/1 "x1h" REDUCER <br />FINISHED CEILING <br />ICK RESPONSE <br />*NT SPRINKLER CONCEALED ESCUTCHEON <br />ARM -OVER / RETURN BEND <br />N.T.S. <br />HANGER SPACING TABLE <br />MAXIMUM DISTANCE BETWEEN HANGERS IN ACCORDANCE TO NFPA 13 TABLE 9.2.2.1 <br />PIPE SIZE SCH. 10 - 40 1 " 14 Jill 2" 22" 3" 4" 6" 8" <br />12'-0" 12'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" <br />REVIEW DATE' <br />CITY OF ZEPHYRHILLS <br />PLAN EXAMJNER ,- <br />ALL WORK SHALL COMPLY WITH <br />PREVAILING CODES <br />FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, AND <br />CITY OF 2EPHYRHILLS ORDINANCES <br />z <br />O_ <br />H <br />Lu <br />0 <br />R. <br />W <br />0 <br />v- <br />CM <br />O <br />z <br />Ow <br />U rn <br />Q M 75 <br />U0-� 00 <br />W Q M X U <br />0 z c� LL <br />Q W <br />0 -1 <br />U)j LL. N X <br />co Oo <br />w < M O <br />LLJ LL0-o U <br />G <br />� Q 00 <br />� <br />LL 0- ~ M <br />o 00 <br />0 ,� w <br />U z <br />O <br />V) <br />J <br />J <br />_ Q Z <br />z Q � Q <br />Ww�0 <br />N � J � <br />0o w <br />O -J J <br />Q r J J <br />— <br />�Q—icco z <br />Ll <br />�0 0 � 0- <br />0 <br />O0 w <br />= UJ w <br />Q N <br />I..L <br />C 0 U <br />W <br />LL <br />BRASFIELD & GORRIE G.C. <br />CONTRACT NO. 1-1-1622-10-16 <br />APPROVAL AHJ <br />DESIGNER YURI <br />SCALE AS NOTED <br />DATE 06-01-2016 <br />FP1 <br />