2 <br />9 <br />4 <br />IC <br />C <br />B1 <br />2 <br />3 <br />3 <br />r I <br />A <br />N <br />DEMOLITION PLAN - HVAC <br />SCALE: 1/4" = 1'-0" <br />GENERAL DEMOLITION NOTES <br />1. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF <br />THE EXISTING CONDITIONS WITHIN THE PROJECT AREA EXISTING EQUIPMENT, STRUCTURE, <br />DUCTWORK, ETC. LOCATED ON DRAWING WERE DERIVED FROM EXISTING DRAWINGS AND LIMITED <br />FIELD OBSERVATIONS. THIS DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE <br />PROJECT AREA. CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION <br />WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO <br />THE ARCHITECT AND ENGINEER PRIOR TO BEGINNING DEMOLITION. BEGINNING OF DEMOLITION SHALL <br />SIGNIFY CONTRACTOR'S ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE <br />FOR ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. <br />2. CONTRACTOR SHALL PERFORM A PRE -BID SURVEY TO FIELD -VERIFY AND COORDINATE ALL <br />DIMENSIONS PRIOR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. <br />COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING <br />ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, <br />LIGHTS, PLUMBING, AND ELECTRICAL CONDUIT. COST OF REROUTING DUCTWORK OR PIPING DUE TO <br />CONFLICTS WITH EXISTING CONDITIONS SHALL BE PAID BY CONTRACTOR. <br />3. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT <br />AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO <br />THESE OTHER SPACES. <br />4. TEMPORARY MECHANICAL SERVICES SHALL BE PROVIDED WHEN NEW WORK AFFECTS SERVICES <br />NEEDING TO REMAIN ACTIVE. COORDINATE SERVICE INTERRUPTIONS WITH OWNER AT LEAST TWO <br />WEEKS IN ADVANCE. <br />5. ALL EQUIPMENT REMOVED UNDER THIS PROJECT SHALL BE TURNED OVER TO THE OWNER AT THE <br />OWNER'S DISCRETION UNLESS OTHERWISE NOTED. <br />6. CONTRACTOR SHALL REMOVE OR RELOCATE EXISTING CONTROLS WHERE NECESSARY. REMOVED <br />CONTROLS SHALL BE RETURNED TO OWNER. <br />7. PROPERLY REMOVE AND DISPOSE OF ALL EXISTING TO BE REMOVED HVAC DUCTWORK, PIPING AND <br />AIR DISTRIBUTION DEVICES. CONSULT WITH OWNER AND OBTAIN OWNER'S APPROVAL PRIOR TO <br />DISPOSAL OF REMOVED MATERIAL. <br />8. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, CONDUIT, ETC. <br />TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY EXISTING <br />OPENINGS IN RATED WALLS OR FLOORS. <br />9. PROVIDE PRECONSTRUCTION TEST & BALANCE FOR SUPPLY, RETURN AND EXHAUST OF EXISTING <br />MECHANICAL EQUIPMENT SERVING PROJECT AREA. INCLUDE FLOW AND STATIC PRESSURE IN MAIN <br />DUCTS, FAN STATIC PRESSURE, MOTOR HP AND FLA, PRESSURE DROP ACROSS AHU COILS AND <br />FILTERS, CHILLED WATER FLOW AND PRESSURE AT AHU. <br />10. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING THE AIR HANDLER AND DUCTWORK SERVING <br />THE AREA PRIOR TO FINAL TEST AND BALANCE. CLEANING OF THE AIR HANDLER AND DUCTWORK <br />SHALL CONSIST OF REPLACING THE FILTERS. <br />11. ALL EXISTING AIR DISTRIBUTION DEVICES LOCATED WITHIN PROJECT AREA SHALL BE FITTED WITH <br />TEMPORARY CONSTRUCTION FILTERS THROUGHOUT PROJECT DURATION TO HELP PREVENT <br />ACCUMULATION OF DUST IN DEVICES AND DUCTWORK. <br />12. CAP ALL DEMOLISHED BRANCH DUCT AT DUCT MAIN. CAP AND SEAL OPENINGS DURING ENTIRE <br />RENOVATION OF THE HVAC DUCTWORK. <br />13. ALL EXISTING AND/OR NEW WALL, CEILING AND FLOOR PENETRATIONS TO THE SPACE SHALL BE <br />CAULKED AND SEALED AIR AND VAPOR TIGHT AFTER DEMOLITION AND PRIOR TO NEW CONSTRUCTION <br />BY AN APPROVED CONTRACTOR. <br />0 <br />DEMO KEY NOTES <br />PROVIDE A TEMPORARY HEPA FILTERED NEGATIVE AIR FAN FOR CONSTRUCTION AREA. MAINTAIN <br />A MINIMUM 0.03" NEGATIVE PRESSURE IN THIS AREA RELATIVE TO THE ADJACENT SPACES. <br />PROVIDE VISUAL DISPLAY OF AIRFLOW DIRECTION. PROVIDE ADDITIONAL NEGATIVE AIR MACHINES <br />AS REQUIRED TO ACHIEVE MINIMUM NEGATIVE PRESSURE. PROVIDE TEMPORARY DUST BARRIER <br />PARTITIONS. ALL EXISTING RETURN REGISTERS AND OPENINGS LOCATED WITHIN THE <br />RENOVATION AREA SHALL BE SHUT AND TAPED CLOSED, ISOLATING THE RENOVATION AREA FROM <br />THE AIR HANDLER SYSTEM. ALL EXISTING EXHAUST REGISTERS LOCATED WITHIN THE <br />RENOVATION AREA SHALL BE PROVIDED WITH TEMPORARY CONSTRUCTION FILTERS. ROUTE <br />TEMPORARY 120 FLEXIBLE DUCT FROM DISCHARGE OF HEPA UNIT TO OUTSIDE OF DEMOLITION <br />BOUNDARY. <br />FAN CRITERIA: <br />MODEL - HEPA-AIRE MODEL PAS2400HC <br />CFM - 700-2100 CFM <br />HPN/P-1.51120/1 <br />O2 PROVIDE AN INCLINED MANOMETER, DIFFERENTIAL PRESSURE TYPE, WITH WHITE FACE GAUGE <br />AND BLACK LETTERS WITH MAXIMUM PRESSURE RANGE OF 0.1" W.G. THIS SHALL BE USED BY THE <br />CONTRACTOR TO RECORD, ON A DAILY BASIS, THE NEGATIVE PRESSURE IN THE RENOVATION AREA <br />20 RELATIVE TO THE ADJACENT SPACES. <br />O CONTRACTOR TO PROVIDE TEMPORARY CONSTRUCTION BARRIER. <br />® DEMO DUCTWORK TO POINT INDICATED. CAP AND SEAL AIRTIGHT WHERE NECESSARY. <br />O5 EXISTING DIFFUSER TO BE RELOCATED. <br />© DEMO PIPING TO POINT INDICATED. CAP AND VALVE, SEE NEW FLOOR PLAN FOR NEW PIPING <br />LOCATION. <br />0 EXISTING DUCTWORK UP TO (E)EF-30 ON ROOF ABOVE SHALL REMAIN. <br />® PROVIDE TEMPORARY WALL PENETRATION FOR NEGATIVE AIR MACHINE DISCHARGE DUCT. <br />REPATCH WALL AFTER CONSTRUCTION. <br />O9 EXISTING STEAM CONDENSATE PIPE TO BE REROUTED TO AVOID NEW DUCTWORK. CUT EXISTING <br />STEAM CONDENSATE AND PREPARE PIPE FOR NEW CONNECTIONS. <br />301 E. Pine Street, Suite 350 <br />Orlando, Florida 32801 <br />407-893-5800 Fax 407-264-6624 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />a TLC I <br />S0LUT10ING <br />©Copyright 2019 <br />255 S. Orange Avenue <br />Suite 1600 COA 15 <br />Orlando, FL 32801 www.tic-engineers.com <br />P 407.841.9050 TLC No.:119469 <br />THINK, I . CREATE. <br />PROJECT TITLE: <br />AdventHealth - ZEPHYRHILLS <br />OPERATING ROOMS BUILT OUT <br />PROJECT ADDRESS: <br />7050 GALL BLVD, <br />ZEPHYRHILLS, FL, 33541 <br />- --- Aaron Lee Johnson, P.E. <br />Florida License #71576 <br />LE E Jo <br />No 71576 <br />zr= <br />'. STATE OF �.• <br />................___.__.. . . . <br />•f��'`S�O N A <br />KEY PLAN - LEVEL 2 <br />SCALE: N.T.S. TRUE PROJECT <br />NORTH NORTH <br />REVISIONS <br />NO. <br />DESCRIPTION <br />DATE <br />6 <br />ADDENDUM No. 4 <br />01.14.22 <br />5 <br />ADDENDUM No. 3 <br />11.10.21 <br />2 <br />ADDENDUM No.1 <br />07.12.21 <br />DATE ISSUED: 12/11/2019 <br />REVIEWED BY: ALJ <br />DRAWN BY: LLP <br />DESIGNED BY: LLP <br />PROJECT NUMBER: <br />504-0253-000 <br />© 2019 RS&H, INC. <br />SHEET TITLE: <br />DEMOLITION PLAN - <br />HVAC <br />SHEET ID: <br />BLDG. ID <br />M102 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright © 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />3" SCALE 0 3" 6" 1' <br />- <br />-T_ <br />1 1/2" SCALE 0 6" 1' 2' <br />3/8" SCALE 3' 0 18" 3' 6' <br />AIt"11,1, ..1l; 1, id IF iLi,. � ! I i ,�� )�) <br />1/4" SCALE 4' 0 2' 4' 8' <br />1/8" SCALE 8' 0 4' 8' 16' <br />