Laserfiche WebLink
- <br />rn O <br />N <br />N <br />1-1 <br />V_ <br />�� <br />00 <br />N <br />S� <br />„h O <br />Co <br />�T <br />N <br />b <br />SMOKE COMPARTMENTS oe EXIT CALCULATIONS <br />Compartment <br />Compartment <br />Area <br />Occupancy <br />Type <br />Sq./ Ft. <br />Occupant <br />Number of <br />Occupants <br />1A <br />12,010 S.F. <br />Treatment <br />240 <br />50 <br />IB <br />19,759 S.F. <br />Treatment <br />240 <br />82 <br />IC <br />16,627 S.F. <br />12,615 -12 <br />4,012 Assembly <br />240 <br />15 <br />53 <br />267 <br />IE <br />13,159 S.F. <br />Treatment <br />240 <br />55 <br />IF <br />12,093 S.F. <br />Treatment <br />240 <br />50 <br />SYMBOL LEGEND <br />• F.E. <br />FIRE EXTINGUISHER <br />F.E.C. <br />FIRE EXTINGUISHER CABINET <br />® <br />MAGNETIC DOOR HOLDER <br />OS <br />SMOKE DETECTOR <br />QH <br />HEAT DETECTOR <br />© <br />FIRE ALARM PULL STATION <br />S ♦ <br />STROBE <br />HIS ►* <br />HORN AND STROBE <br />EXIT LIGHTS <br />I <br />EXIT LIGHTS WITH DIRECTIONAL ARROW(s) <br />42 <br />EXIT WIDTH IN INCHES <br />125' <br />INTERIOR EXIT PATH AND DISTANCE <br />1 A <br />SMOKE COMPARTMENT DESIGNATION <br />SMOKE COMPARTMENTS / EX/T CALCULATIONS <br />Compartment <br />Compartment <br />Area <br />Occupancy <br />Type <br />Sq./ Ft. <br />Occupant <br />Number of <br />Occupants <br />IG <br />4,989 S.F. <br />Treatment <br />240 <br />21 <br />I H <br />6,289 S.F. <br />Treatment <br />240 <br />27 <br />ll <br />11,971 S.F. <br />Treatment <br />240 <br />50 <br />IJ <br />14,951 S.F. <br />Treatment <br />240 <br />63 <br />TOTAL FIRST FLOOR SQUARE FOOTAGE - 111,848 SQ.FT . 718 <br />EXITS UNITS REQUIRED - 718 X .2 = 144' <br />EXIT UNITS PROVIDED - 1,279' <br />BUILDING CODE ANALYSIS <br />I. Codes in effect: <br />5. Exit Calculations <br />Permitted <br />Proposed <br />Florida Building Code 2007 Edition with both first and <br />second 2009 ammendments <br />NFPA 101 2006 Edition <br />Max. Travel Distance: <br />200 <br />161 <br />Florida Administrative Code 59A3 <br />Max. Dead End Corridor: <br />20/-OH <br />NA <br />AI A Guidelines for Design and Construction of Health <br />Care <br />Facilities 2006 Edition <br />Min. Corridor Width: <br />8'-0" <br />8'-O" <br />Min. Clear Opening of Exit Doors: <br />321, <br />321, <br />2. Use and Occupancy Classification: <br />Group <br />1-2 <br />Min. Stair Width: <br />8'-0" <br />NA <br />As per FBC Chapter 3 and NFPA 101 <br />J. Type of Construction: <br />Type I <br />-B, Fully Spri nkl eyed <br />6.. Interior Finish Requirements <br />As per FBC Section 602 and NFPA 101 Table 8.1 <br />Type 1 <br />(3,30 <br />As per FBC Table 803.5 <br />and NFPA 101 Table A 10.2.2 <br />4. Building Occupancy <br />Exits: <br />Type A <br />Building Occupancy per FBC Table 1004.1.2 <br />Exit Access Corridors: <br />Type A <br />and NFPA l01 table 7.5.1.2 (in SF/Occupant): <br />240 <br />Rooms & Enclosed Spaces: <br />Type A <br />Area ea Compartment 1 A <br />12,010 <br />SF <br />Allowed Occupancy <br />50 <br />U <br />a� <br />U <br />M M <br />0 i <br />0 <br />ill N � M O <br />oNo W a .-1 <br />y <br />a <br />r H <br />a <br />r/) U <br />n <br />w is <br />VI <br />r� <br />e� <br />N <br />Cd <br />CIO <br />En <br />0 <br />Cd <br />• V..4 <br />0 <br />—4 <br />Cd <br />1� <br />rr♦� <br />TCd <br />V 1 <br />0 <br />•C .0 <br />c <br />1� <br />Project No. 11007.00 <br />A 1. 0 <br />121812011 3:15:39 PM ...\AI-0 Partial Life Safety Plan.dgn <br />© 2011 BH/ PK Architects, Inc. <br />