Laserfiche WebLink
N <br />N <br />o <br />N <br />O <br />9 <br />r <br />01 <br />N <br />O N <br />o <br />03 <br />N <br />0 <br />rn o <br />N <br />B <br />OR D HOS z <br />F A PITA <br />P <br />y I <br />H RH S <br />MR1 RF--... PLACEMENT <br />Florida 11-1c)spital Ze h rhills <br />l� Y <br />7050 Gall Boulevard <br />Ze hyrhills, FL 33541 <br />l� <br />Client Code / ]File <br />- Prc3ject <br />submission <br />Number: 23 / 100046-1-5 <br />PROECT TEAM DIRECTORY <br />SYMBOLS AND <br />MATERIALS <br />GENERAL NOTES <br />INDEX OF DRAWINGS <br />A0.0 <br />Cover Sheet <br />Industry standards (i.e. ASTM, ANSI, etc.) shall have the some force and effect. <br />OWNER <br />on performance of work as if copies were directly Inserted Into the Contract Documents or bound and <br />published therewith. Comply with standards in effect as of the date of the Contract Documents, <br />ARCHITECTURAL <br />AO WINDOW TYPE <br />� EARTH <br />unless otherwise note or required by authorities having jurisdiction. <br />Florida Hospital Zephyrhills <br />CODES -All work shall conform to the following codes and ordinances: <br />AS.1 <br />Portable MRI Unit <br />7050 Gall Boulevard <br />ELEVATION BENCHMARK <br />GRANULAR FILL <br />2014 Florida Building Code <br />2014 Florida Plumbing Code <br />2014 Florida Fuel Gas Code <br />A1.0 <br />Al.l <br />First Floor Life Safety Plan <br />First Floor ICRA Plan <br />Zephyrhills, Florida 33541 <br />0 <br />REVISION AND NUMBER <br />METAL <br />2014 Florida Mechanical Code <br />2014 Florida Accessibility Code <br />A2.0 <br />Demolition Plan and Floor Plan <br />Phone: (813) 788-0411 <br />C.J.D CONTROL JOINT <br />2014 Florida Energy Conservation Code <br />2014 Florida Existing Building Code <br />A2.1 <br />A2.2 <br />Ceiling Plan and Details <br />Second Floor and Roof Plan <br />® FINISH WOOD <br />Florida Fire Prevention Code Fifth Edition - Effective December 31, 2014 <br />Local Codes and Ordinances and flood damage prevention ordinances where applicable <br />A5.1 <br />Specifications <br />ARCHITECT <br />DOOR AND FRAME <br />WITH DOOR NUMBER <br />00 <br />� STUCCO OR GYPSUM BOARD <br />2012 NFPA 101 Life Safety Code <br />- 2012 NFPA 99 -Health Care Facilities <br />2010 Guidelines for Design and Construction of Health Care Facilities <br />STRUCTURAL <br />CONCRETE OR GRAVEL <br />Burt Hill / Pollock Krieg Architects, Inc. <br />EXISTING DOOR <br />51,0 <br />Structural Notes and Abbreviations <br />8250 College Parkway Suite 203 <br />METAL STUD WALL <br />CONCRETE MASONRY UNIT (CMU) <br />BUILDING CODE INFORMATION <br />OCCUPANCY GROUP : GROUP 1-2 <br />S2.0 <br />S2.1 <br />Structural Roof Plan and Details <br />Structural First Floor Plan and Details <br />Fort Myers, Florida 33919 <br />MASONRY WALL <br />® PLYWOOD <br />TYPE OF CONSTRUCTION : TYPE I-B <br />PLUMBING <br />Phone: 239 482-4761 <br />( ) <br />EVALUATION <br />TYPE 1(3,3,2) FULLY SPRINKLERED (NFPA) <br />Fax: (239) 482-0265 <br />ROOM NAME AND NUMBER <br />20a <br />® ACOUSTIC CEILING TILE <br />SQUARE FOOTAGE OF REMODELING: 1,106s ft <br />Q <br />PLO <br />Plumbing Legend, General Notes, Fixture <br />WALL TYPE <br />lumbing Partial <br />Floor Plan <br />® BATT OR SEMI -RIGID INSULATION <br />P2.0 <br />Plumbing Mobile MRI <br />BUILDING SECTION <br />MECHANICAL/ELECTRICAL ENGINEERS <br />mm <br />RIGID INSULATION <br />MECHANICAL <br />KPI Engineering Inc. <br />11J� SECTION OR DETAIL <br />� ELEVATION <br />ROUGH WOOD FRAMING <br />OR BLOCKING <br />I. Contractor to oversee cleaning and Insure that the premises are maintained free of rubbish during construction. Final cleanup Is the/ <br />responsibility of the Contractor. Contractor to provide Permitting Authority with Debris Affidavit of time of submittal. <br />MI.0 <br />Abbreviations, Legend and General Notes <br />/ p <br />3203 Queen Palm Drive <br />® INTERIOR ELEVATION <br />2. At the termination of work, submit to Building Agent/Tenant maintenance manuals presenting full details for care and maintenance of all <br />surfaces and equipment of every nature. Contents shall Include manufacturer's and Installer's names, addresses, and phone numbers, and <br />instructions for installation, start-up, operation, maintenance parts list, and data sheets. <br />M2.0 <br />Infection Control Plan <br />HVAC 1st Floor Plan -Demolition <br />C��S <br />Tampa Florida 33619 <br />M4.0 <br />HVAC 1 st Floor Plan -New Construction <br />���� <br />p p <br />Phone: (813) 241-6488 <br />NORTH ARROW <br />J. Contractor is responsible for compliance with all Codes, Ordinances and Regulations applicable of project location. Contractor is responsible <br />for filing and securing all necessary permits, approvals, etc. for all trades. <br />M4.1 <br />' <br />HVAC 2nd Floor Plan - New Construction <br />New Construction <br />_„ <br />�_� <br />��%1 S <br />Fax: (813) 241-6498 <br />4. When 'or equol','olternote', or other qualifying Terms are used, those Items sha!1 be approved by Building Agent/Tenant and/or Architect. <br />M4.3 <br />HVAC Mobilr MRI <br />il��00; <br />5. Existing materials or Items scheduled to remain that are damaged by construction shall be repaired, patched, and refinished to the nearest <br />intersection, restoring surface to it's original condition. <br />M5.0 <br />a Details <br />�L <br />STRUCTURAL ENGINEERS <br />0 <br />.......... .... . <br />6. Contractor shall protect all existing walls, doors, frames, surfaces, fixtures, flnlshes, etc. from damage during demolition and construction. Existing <br />materials to be removed shall be coordinated with Owner to verify if Owner wishes to salvage some. Relocation of salvaged materials, once <br />removed, to be by the Building Agent/Tenant's forces <br />FIRE PROTECTION <br />/� <br />VICINITY MAP �I <br />arc. <br />FP 1.0 <br />Abbreviations, Legends, General Notes and <br />Details <br />TLC Engineering for Architecture <br />z <br />b <br />- <br />7. Contractor shall verify and be responsible for all dimensions and job site conditions related to this work. Any discrepancy in dimensions or <br />special modifications required due to field conditions shall be reported to the Architect for clarification <br />FP2.0 <br />, <br />Fire Projection Demolition and New Construction Partial Plans <br />500 North Westshore Blvd #43 5 <br />L k� <br />V. <br />8. The Architect does not hove control or charge of, and shall not be held responsible for construction means, methods, techniques, sequence or for <br />safety precautions and programs in connecfiurr, wl!h work, for the acts or omissions of the contractor, sub -contractors or any other persons <br />Tampa Florida 33609 <br />performing any of the work, or for the failure of any of them to carry out the work In accordance with the Documents. <br />ELECTRICAL <br />ALL <br />Phone: 813-637-01 10 <br />9. All pipes, ducts,conduit,etc.,which penetrate the final slab or walls shall be installed so as to maintain the fire resistive and structural integrity <br />of the building construction. <br />E_1,0 <br />Legend Abbreviations and General NotesEVWO'�ALLOp <br />AILING <br />°�Es�TN <br />Fax: 813 - 6 3 7 - 0 013 <br />pair �K <br />a <br />l0. Demolition of existing construction necessary to Install new construction and equipment is to be performed by the contractor who Is to <br />supply and install the new construction and equipment. Install Ilntels where required with prior written approval. <br />E-2.0 <br />E-3.0 <br />Demolition and New Feeder Plan°�E, <br />New Construction <br />NA,�� 'FLORID AL <br />CITYoF AL EL ABUILD1 <br />Z�PI�yLS rW�CODEgN <br />ORD <br />- <br />11. Contractor to repair floor slabs, fill gaps, cracks and voids. Grind smooth any high spots or ridges. Floors to be prepared as required to <br />receive floor finishes so that previous substrate defects cannot be detected. <br />E-5.0 <br />Portable MRI Plan <br />�ANCES <br />KEY PLAN <br />` Es=a=�s <br />= ?. ��_ �� � <br />12. GENERAL CONDITIONS OF THE CONTRACT, AIA Document A201, latest edition, shall apply. <br />E-6.0 <br />MRI Electrical Installation <br />�� <br />S. <br />r� Kr <br />13. fire extinguisher cabinets mounting height to be 2'-6' from floor to bottom of receptacle. Top of extinguisher to be 4'-0' AFF, max. <br />E-6.1 <br />MRI Electrical Installation <br />r <br />ite <br />_ <br />.......................................................... ...... .......... <br />14. Not all listed GENERAL NOTES may apply, nor are they all-inclusive for every work situation. Excellence, through -out the job, does apply. <br />_ <br />- <br />- <br />I5. Each new FIRE WALL, FIRE BARRIER, FIRE PARTITION, SMOKE BARRIER, SMOKE PARTITION, or any other new wall <br />required to have protected openings shall be permanently identified with signs or stenciling above any <br />'FIRE <br />} <br />f1 <br />�i <br />Rao •f <br />s co�•r'ry •�1., <br />C iC� <br />decorative ceiling and in concealed spaces with the words, AND SMOKE BARRIER PROTECTED ALL OPENINGS', <br />or similar language. Sign or stenciling to include UL Design number of partition. Such signs or stenciling shall be In 4-inch <br />high letters, %p -Inch stroke, and not more than 15-feet on center. Per Florida Fire Protection Code 101:8.3.2.4. <br />_ <br />' <br />16. Contractor to repair any damaged spray flreproffing. Patch shall be completed to maintain the require fire resistant rating. <br />Lyndon T. Pollock <br />a <br />I = <br />c <br />-....- <br />r <br />Refer also <br />to Siemens Medical Drawing <br />g <br />Registered Architect AR0006747 <br />- = <br />Florida Hospital <br />1Z Zephyrhills Project 420 <br />ephyr i s rojec 140 <br />TM <br />B ,.„ ar�s <br />dated 7/10/15 <br />j <br />- I o <br />�II-�II-jII-�II �II(�III <br />.?....?......................... ?.?....... ?..................... <br />z a,�lythtlls <br />.,� <br />.. ..........? <br />PROJECT LOCATION <br />, <br />Project No. 15017.00 <br />©2015 BH/PK Architects, Inc. I <br />111812016 3:39:10 PM ...\cd\AO-0 Cover Sheet.dgn <br />