Laserfiche WebLink
1 <br />EXISTING V. 0. AND MA <br />PIPING TO REMAIN (VIF) <br />REMOVE EXISTING OUTLETS <br />AND VERTICAL DROPS <br />3 <br />A2 <br />2 <br />Z <br />0- <br />ABV. CLG. <br />EXISTING TOILET <br />SHALL REMAIN <br />1/2" m_,i H@ <br />-3/4" <br />t <br />\A <br />t <br />R�\ <br />1 <br />ABV. CLG. _ <br />-3/4- <br />_ i <br />{ <br />----- <br />-1/2 <br />i1 - <br />PkAF <br />V <br />i <br />EXISTING TOILET vy- <br />? <br />SHALL REMAIN <br />I <br />E E <br />i <br />3/4V <br />DROPS TO BUILDING <br />1/2N 0 <br />STANDARD MED. GAS <br />I <br />1 /' 2 A <br />OUTLETS <br />. <br />..._.... <br />F <br />I <br />i <br />_T <br />PLUMBING 1st FLOOR PLAN - NEW CONSTRUCTION <br />MEDICAL GAS GENERAL NOTES <br />1. <br />CONTRACTOR SHALL PROVIDE COMPLETE MEDICAL GAS SYSTEMS AS DETAILED ON THESE <br />13. <br />VERIFY THE EXACT LOCATION OF EXISTING OXYGEN, MEDICAL AIR, NITROUS OXIDE, <br />DRAWINGS. WORK CONSISTS OF FURNISHING ALL MATERIALS, EQUIPMENT, AND SERVICES <br />MEDICAL VACUUM, AND NITROGEN PIPING MAINS FROM THE EXISTING MEDICAL OFFICE <br />REQUIRED FOR COMPLETE SYSTEMS. INCLUDE ANY INCIDENTAL APPARATUS, <br />BUILDING. ALL NEW LINES ARE TO BE ROUTED TO AND/OR FROM VERIFIED <br />APPLIANCES, MATERIAL LABOR AND SERVICES NECESSARY TO MAKE NEW WORK <br />LOCATIONS. TAPS, WHEN NOT PROVIDED BY PREVIOUS INSTALLER, ARE TO BE PROVIDED <br />COMPLETE IN ALL RESPECTS AND FULLY READY FOR OPERATION. <br />BY THIS INSTALLER. <br />2. <br />ALL MEDICAL GAS WORK SHALL BE DESIGNED, INSTALLED, TESTED, LABELED, AND <br />14. <br />THE INSTALLER SHALL VISIT THE JOB SITE AND INSPECT ALL EXISTING CONDITIONS <br />CLEANED IN ACCORDANCE WITH NFPA 99-12 CODE REQUIREMENTS. <br />AFFECTING THE WORK. SUBMISSION OF HIS PROPOSAL SHALL BE CONSTRUED AS <br />INDICATING SUCH KNOWLEDGE. NO ADDITIONAL PAYMENT WILL BE MADE ON CLAIMS <br />3. <br />MAKE SUCH OFFSETS AND DEVIATIONS FROM WORK SHOWN ON THE DRAWINGS, AS MAY <br />THAT ARISE FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT. <br />BE NECESSARY TO FIT THE ACTUAL SPACE CONDITIONS. <br />15. <br />PROVIDE AND MAINTAIN TEMPORARY CONNECTIONS TO KEEP EXISTING UTILITIES IN <br />4. <br />WHERE VALVES OCCUR ABOVE DRYWALL OR PLASTER OR ARE CONCEALED BEHIND <br />SERVICE. ANY SHUT DOWNS ARE TO BE APPROVED BY OWNER'S REPRESENTATIVE. <br />WALLS, THIS CONTRACTOR SHALL FURNISH AND INSTALL ACCESS PANELS. PANELS <br />SHALL MATCH EXISTING. <br />16. <br />FIELD VERIFY ALL EXISTING PIPE SIZES PRIOR TO INSTALLATION. <br />5. <br />THE PLANS AND DIAGRAMS OF MEDICAL GAS PIPING ARE SCHEMATIC ONLY AND SHOULD <br />17. <br />THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO IDENTIFY ABOVE CEILING <br />NOT BE SCALED. INSTALLER SHALL COORDINATE AT SITE WITH ALL EXISTING PLUMBING, WVAC, <br />CONFLICTS. THE CONTRACTOR IS RESPONSIBLE TO ALSO CHECK FIELD CONDITIONS <br />FIRE PROTECTION, MEDICAL GASES, AND ELECTRICAL WORK SO AS NOT TO CONFLICT IN <br />PRIOR TO BIDDING AND REPORT ANY PROBLEMS/CONFLICTS TO THE ENGINEER WITHIN 2 <br />LOCATION WITH OTHER WORK UNDER THIS CONTRACT OR THAT MAY BE EXISTING. <br />DAYS OF DISCOVERY. ANY CHANGES RESULTING FROM CONDITIONS ARISING IN THE <br />6. <br />EXACT LOCATION NUMBER MEDICAL GAS OUTLETS SHALL BE DETERMINED FROM <br />FIELD WHICH WERE NOT BROUGHT TO THE ENGINEER'S ATTENTION ARE TO BE MADE BY <br />ARCHITECTURAL DRAWINGS. VERIFY SUCH LOCATIONS BEFORE PROCEEDING ROUGH -IN. <br />THIS CONTRACTOR WITH NO ADDITIONAL COST TO THE OWNER. <br />7. <br />INSTALLER SHALL NOT CUT ANY EXISTING STRUCTURAL MEMBERS WITHOUT FIRST SECURING <br />18. <br />UPON COMPLETION OF THE WORK UNDER THIS CONTRACT, THE CONTRACTOR SHALL <br />WRITTEN APPROVAL FROM THE ARCHITECT. <br />REMOVE ALL TOOLS, APPLIANCES, SURPLUS MATERIALS, AND SCRAP. ALL IDENTIFIED <br />EXISTING EQUIPMENT TO BE REMOVED SHALL BE TURNED OVER TO THE OWNER. <br />8. <br />PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS BETWEEN DISSIMILAR PIPING METALS. <br />19. <br />CONDITIONS SHOWN AS EXISTING (LOCATIONS, MATERIALS, ELEVATIONS, SIZED, ETC.) <br />9. <br />WHEN CONFLICTS OCCUR IN SPECIFICATIONS OR IN THE DRAWINGS, OR BETWEEN EITHER, <br />ARE BASED ON AVAILABLE EXISTING DATA AND SHOULD BE INTERPRETED TO BE <br />THE ITEMS OF GREATER QUANTITY OR HIGHER COST SHALL BE PROVIDED. <br />APPROXIMATE. CONTRACTOR SHALL VERIFY CONDITIONS IN THE FIELD. EXISTING <br />CONDMONS FOUND TO DEVIATE FROM THOSE SHOWN SHALL BE REPORTED TO THE <br />10. <br />THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES IN ORDER TO AVOID <br />ENGINEER. <br />CONFLICTS. <br />20. <br />PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS BETWEEN DISSIMILAR METALS. <br />11. <br />ALL NEW MEDICAL GAS PIPING SHALL BE TYPE K COOPER. MINIMUM PIPE SIZE FOR <br />OXYGEN AND AIR PIPING SHALL BE 1/2" MINIMUM PIPE SIZE FOR VACUUM PIPING SHALL <br />21. <br />CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REINSTALLING ALL CEILING TILES AND GRIDS <br />BE 3/4" MINIMUM. ALL NEW PIPING SHALL BE PROVIDED PRECL.EANED IN ACCORDANCE WITH <br />AS NECESSARY TO INSTALL NEW MEDICAL GAS SYSTEM. <br />NFPA 99 REQUIREMENTS. <br />22. <br />CONTRACTOR TO CONTINUOUSLY PURGE MEDICAL GAS PIPING WITH DRY NITROGEN WHILE BRAZING <br />12. <br />PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. PENETRATIONS FOR PIPES, <br />ALL PIPING JOINTS. <br />CONDUITS, OR OTHER PURPOSES THROUGH ASSEMBLIES (FLOORS„ WALLS, PARTITIONS, <br />23. <br />CONTRACTOR SHALL ARRANGE FOR, OBTAIN AND BEAR THE COST OF <br />ETC.) WITH A REQUIRED FIRE STOP MATERIAL FIRE STOP MATERIAL SHALL BE U.L. <br />NECESSARY PERMITS, BONDS AND FEES. <br />LISTED AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S <br />REQUIREMENTS TO MEET OR EXCEED THE FIRE RATING OF THE PENETRATED ASSEMBLY. <br />ABBREVIATIONS <br />2 <br />A <br />M DI AL AI <br />AFF <br />ABOVE FI IHED FLOOR <br />CP <br />CHROME PLATED <br />CLG <br />CEILING <br />CW <br />COLD WATER <br />DN <br />DOWN <br />FL <br />FLOOR <br />2N <br />0 <br />OXYGEN <br />LION <br />UNLESS OTHERWISE NOTED <br />V <br />VENT <br />I I L <br />2 VF <br />VACUUM <br />PIPING <br />EXISTING PIPING SHALL REMAIN (VIF) <br />EXISTING PIPING SHALL BE REMOVED <br />NEW COLD WATER PIPING <br />NEW HOT WATER PIPING <br />NEW WASTE PIPING <br />EXISTING MEDICAL AIR PIPING TO REMAIN <br />EXISTING OXYGEN PIPING TO REMAIN <br />EXISTING VACUUM PIPING TO REMAIN <br />NEW MEDICAL AIR PIPING TO REMAIN <br />NEW OXYGEN PIPING TO REMAIN <br />NEW VACUUM PIPING TO REMAIN <br />PLUMBING FIXTURE SCHEDULE <br />MARK <br />ITEM <br />COLD <br />WATER <br />HOT <br />WATER <br />WASTE <br />VENT <br />ITV <br />LAVATORY: AMERICAN STANDARD 10355.012 LUCERNE WALL MOUNTED 20-1/2- X 18-1/4" VITREOUS CHINA, THREE HOLES, 4" <br />CENTERS, FRONT OVERFLOW, FOR CONCEALED ARMS FAUCET: T & S B-0892 CP RIGID GOOSENECK WITH 4" WRIST BLADE <br />HANDLES AND LAMINAR FLOW DEVICE <br />DRAIN: BRASSCRAFT 1-1/4" X 1 1/4" CHROME PLATED GRID DRAIN WITH 17 GAUGE TAILPIECE 1-1/4" X 1 <br />1/2- <br />1/2" <br />1-1/2" <br />EXISTING <br />"TRAP: "BRASSCRAFT <br />1/2 CHROME PLATED 17 GAUGE P TRAP WITH CLEANOUT SUPPLIES: BRASSCRAFT 1/2 X 3/8 X 12 CHROME PLATED FLEXIBLE <br />SUPPLIES WITH LEAD FREE LOOSE KEY STOPS CARRIER: ZURN WALL CARRIER FOR CONCEALED ARMS INSULATE WASTE AND WATER <br />PLIES BELOW LAVATORY WITH TRUEBRO PIPE INSULATION COLOR/ FlNI <br />HOSE BIBB: 1. ROUGH CHROME FACE, WITH 34HF INTEGRAL VACUUM BREAKER - HOSE CONNECTION, 1/2- CONNECTION - W00 <br />1/2 <br />- <br />- <br />- <br />MODELJ24, MOUNT 0 18" ABOVE GRADE AND/OR FLOOR <br />1 <br />I10 <br />1 <br />- EXISTING WALL TO REMAIN <br />EXISTING VERTICAL HOT AND WATER <br />COLD WATER SUPPLIES TO REMAIN <br />0 <br />NEW PLUMBING FIXTURE WITH <br />CONCEALED WALL CARRIER <br />NEW 1-1/4' X 1-1/2" <br />CHROME PLATED TAILPIECE <br />NEW 3 8" CHROME PLATED HOT AND COLD <br />CHROME PLATED FLEXIBLE SUPPLIES <br />NEW 3/8" X 1/2" CHROME PLATED LEAD <br />FREE LOOSE KEY STOPS <br />NEW 1-1/4" X 1-1/2- CHROME PLATED <br />P TRAP WITH CLEANOUT <br />NEW CHROME PLATED <br />ESCUTCHEONS <br />EXISTING FLOOR <br />DIAGRAMMATIC NEW PIPING <br />FIXTURE DETAIL NOT TO SCALE <br />SPECIFICATIONS <br />1.0 <br />BASIC MATERIAL AND METHODS <br />1.1 <br />SCOPE OF WORK <br />PROVIDE LABOR AND MATERIALS AS REQUIRED TO PROVIDE A FULLY FUNCTIONING AND COMPLETE SYSTEM AS INDICATED 2.1 <br />EQUIPM�Q <br />ON DRAWINGS. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OF <br />A. Acceptable Manufacturers: Provide products by the following: Chemetron by Allied. <br />SYSTEMS AND EQUIPMENT. FINAL LOCATIONS OF EQUIPMENT SHALL BE FIELD DETERMINED. ALL DISCREPANCIES ON <br />DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO SUBMISSION OF BIDS. <br />B. Shutoff Valves: Medical gas shutoff valves shall be Chemetron 7700-83-1105, bronze -bodied, double <br />seal full flow, union ball type with neoprene seat seals and 0-ring packing. Design for working pressures up <br />1.2 <br />QUALITY CONTROL <br />to and including 300 psi and so quarter turn of lever -type handle is maximum travel between open and closed <br />UNLESS OTHERWISE NOTED, PROVIDE NEW MATERIALS FREE OF DEFECTS, WHERE NO SPECIFIC WEIGHTS OR GRADES ARE <br />positions. Provide valves with color -coded identification labels, and in -out copper tube connecting extensions. <br />SPECIFIED PROVIDE MATERIALS OF AN ACCEPTED STANDARD WEIGHT AND GRADE ACCORDING TO CODE AND GOVERNING <br />C. Wall Outlets: <br />STANDARDS BY NFPA AND UL• INSTALL ALL EQUIPMENT, PIPING, IN <br />ACCORDANCE WITH CODES, GOVERNING STANDARDS, AND MANUFACTURER'S RECOMMENDATIONS. <br />1. Medical gas wall outlets shall be Chemetrom 64-01-5001, 64-01-5002 AND 64-01-5003 <br />air, and vacuum, or building standards. <br />1.4 <br />COORDINATION <br />2. Modular design with 16 ga. steel mounting plate. Brass outlet block attached to the mounting plate with <br />COORDINATE ALL WORK FOR PROPER LOCATION, POWER, AND UTILITY REQUIREMENTS. SCHEDULE INSTALLATIONS TO <br />swivel type 3/8" O.D. copper tube inlet. Gas service identification shall be affixed to the inlet tube and the <br />AVOID CONFLICT AMONG TRADES. ADDITIONS TO THE CONTRACT FOR COORDINATION AMONG TRADES WILL NOT BE <br />face of this mounting plate. <br />ALLOWED. <br />3. A metal trim plate with permanent, color -coded marking of service identification shall be included as part of <br />the latch/valve assembly. A push button release mechanism, for disconnecting apparatus shall be accessible <br />1.5 <br />PENETRATIONS. CUTTING AND PATCHING <br />from the top, bottom and side of the outlet. <br />SEAL ALL PIPING PENETRATIONS OF WALLS IN ACCORDANCE WITH ARCHITECTURAL DRAWINGS AND <br />4. A die cast, chrome plated coverplate shall be provided to trim each outlet and to fill the space between <br />SPECIFICATIONS. PIPING PENETRATIONS OF RATED FLOORS AND WALLS SHALL BE SEALED WITH FIRE STOPPING MATERIAL. <br />adjacent outlets. Coverplate design shall allow latch valves to be individually removed for servicing. <br />FLASH ALL ROOF AND WALL PENETRATIONS IN ACCORDANCE WITH ARCHITECTURAL DRAWINGS. <br />3.0 <br />SUBMITTALS <br />2.0 <br />PIPING <br />PROVIDE 6-SETS (EACH) OF MANUFACTURERS PLUMBING FIXTURES, O&M MANUALS, ELECTRICAL DATA, DIMENSIONAL DATA AND <br />A. Copper Tube, Fittings, Valves, and Piping Components: Factory- cleaned, -urged, and -sealed, and marked or <br />"CLEANED "CLEAN <br />CLEARANCES, CONNECTION DATA, COLOR SAMPLES (IF REQUIRED) AND TEST DATA FOR THE FOLLOWING: <br />labeled FOR MEDICAL GAS SERVICE,- FOR OXYGEN SERVICE. <br />B. Components required, but not available cleaned for medical gas use, may be provided, but must be cleaned <br />SHOP DRAWINGS MUST BE SUBMITTED AND APPROVED PRIOR TO ORDERING EQUIPMENT. ENGINEER WILL REQUIRE <br />10 WORKING DAYS TO REVIEW DRAWINGS. <br />before use as specified below under -PREPARATION." <br />C. Pipe joining materials, specialties, and basic installation requirements are specified in Division 15 Section <br />"Basic Mechanical Materials and Methods. - <br />MEDICAL GAS TUBE <br />A. Hard Copper Tube: ASTM B 88, Type K or Type L, water tube, seamless, drawn temper. <br />B. Precleaned and Sealed Copper Tube: ASTM B 88, Type K or Type L, water tube, seamless, drawn temper, <br />cleaned for medical gas use, purged, and with ends sealed. All medical gas piping shall be furnished pre -cleaned <br />and plugged per NFPA 99 (1993) requirements. On site cleaning is limited to recleaning of the joints in accordance <br />with NFPA 99 requirements. <br />TUBING JOINING MATERIAL <br />A Brazing Filler Metals: BS EN 1044 AG351 (silver solder) Series alloys. Flux is prohibited, except when <br />used with bronze fittings. During brazing operations, all medical gas piping is to be continuously purged with <br />nitrogen in accordance with NFPA 99 requirements. <br />DRAWING INDEX <br />PLUMBING <br />P1.0 PLUMBING LEGEND, GENERAL NOTES FIXTURE SCHEDULE AND DETAILS <br />AND PLUMBING PARTIAL FLOOR PLAN <br />P2.0 PLUMBING MOBILE MRI <br />PLUMBING GENERAL NOTES <br />1. ALL WORK SHALL BE DESIGNED, INSTALLED, TESTED, AND CLEANED IN ACCORDANCE WITH <br />THE 2014 EDITION OF THE FLORIDA BUILDING CODE AND THE 2014 FLORIDA PLUMBING CODE. <br />2. CONTRACTOR SHALL PROVIDE COMPLETE PLUMBING SYSTEMS AS DETAILED ON THESE DRAWINGS. <br />WORK CONSISTS OF FURNISHING ALL MATERIALS, EQUIPMENT, AND SERVICES REQUIRED FOR <br />COMPLETE SYSTEMS. INCLUDE ANY INCIDENTAL APPARATUS, APPLIANCES, MATERIAL LABOR AND <br />SERVICES NECESSARY TO MAKE NEW WORK COMPLETE IN ALL RESPECTS AND FULLY READY FOR <br />OPERATION. <br />3. VERIFY THE EXACT LOCATION OF EXISTING WASTE AND WATER SUPPLY FROM <br />THE ACTUAL JOB SITE PRIOR TO SUBMITTING BID. SUBMISSION OF YOUR PROPOSAL <br />SHALL BE CONSTRUED AS INDICATING SUCH KNOWLEDGE. NO ADDITIONAL PAYMENT WILL BE <br />MADE ON CLAIMS THAT ARISE FROM THE CONTRACTORS FAILURE TO COMPLY WITH THIS <br />REQUIREMENT. <br />4. MAKE SUCH OFFSETS AND DEVIATIONS FROM WORK SHOWN ON THE DRAWINGS, AS MAY BE <br />NECESSARY TO FIT THE ACTUAL SPACE CONDITIONS. <br />5. WHERE VALVES OCCUR ABOVE DRYWALL OR PLASTER OR ARE CONCEALED BEHIND WALLS, THIS <br />CONTRACTOR SHALL FURNISH AND INSTALL ACCESS PANELS. COORDINATE COLOR AND STYLE <br />WITH ENGINEER/ARCHITECT. <br />6. INSTALLER SHALL NOT CUT ANY EXISTING STRUCTURAL MEMBERS WITHOUT FIRST SECURING <br />WRITTEN APPROVAL FROM THE ARCHITECT. <br />7. PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS BETWEEN DISSIMILAR PIPING METALS. <br />8. PROVIDE LAVATORY WITH TRAP FITTINGS FOR CLEANOUT. <br />9. CONTRACTOR IS RESPONSIBLE TO ALSO CHECKING FIELD CONDITIONS PRIOR TO BIDDING AND <br />REPORT ANY PROBLEMS/CONFLICTS TO THE ENGINEER WITHIN 2 DAYS OF DISCOVERY. ANY <br />CHANGES RESULTING FROM CONDITIONS ARISING IN THE FIELD WHICH WERE NOT BROUGHT TO THE <br />ENGINEER'S ATTENTION ARE TO BE MADE BY THIS CONTRACTOR WITH NO ADDITIONAL COST TO THE <br />OWNER. <br />10. ALL WORK IS TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE(1) <br />YEAR FROM DATE OF FINAL ACCEPTANCE. ALL DEFECTS WHICH DEVELOP OR ARE DISCOVERED <br />WITHIN THIS PERIOD SHALL BE REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE <br />OWNER AT NO ADDITIONAL COST TO THE OWNER. <br />11. UPON COMPLETION OF THE WORK UNDER THIS CONTRACT, THE CONTRACTOR SHALL REMOVE ALL <br />TOOLS, APPLIANCES, SURPLUS MATERIALS, AND SCRAP. ALL IDENTIFIED EXISTING EQUIPMENT TO <br />BE REMOVED SHALL BE TURNED OVER TO THE OWNER. <br />12. THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES IN ORDER TO AVOID CONFLICTS. <br />CODES AND STANDARDS <br />THE FLORIDA BUILDING CODES 2010 <br />(BUILDING, PLUMBING, MECHANICAL, FUEL GAS, HURRICANE ZONES) <br />HOSPITAL LICENSURE (FAC 59A-3), LATEST PROMULGATION <br />UNIFORM FIRE SAFETY STANDARDS FOR HOSPITALS AND NURSING HOMES (FAC 4A-53), LATEST PROMULGATION <br />NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, 2012 <br />NFPA 70, NATIONAL ELECTRIC CODE, 2011 <br />NFPA 72, NATIONAL FIRE ALARM CODE, 2010 <br />NFPA 99, STANDARD FOR HEALTH CARE FACILITIES, 2012 <br />NFPA 101, LIFE SAFETY CODE, 2012 <br />ASME-A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS 2007 A17.10 2008 AND A17.1b-2009 ADDENDA <br />UNDERWRITERS'S LABORATORIES FIRE RESISTANCE DIRECTORY, LATEST EDITION <br />UNDERWRITERS'S LABORATORIES BUILDING MATERIALS DIRECTORY LATEST EDITION <br />STANDARD CONSTRUCTION DETAILS, PUBLISHED BY AHCA PLANS AND CONSTRUCTION <br />FLORIDA FIRE PREVENTION CODE - 2004 <br />GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND HEALTH CARE FACILITIES, 2001 EDITION <br />\'\\` NfkD' Mp 7' <br />c'�y'i. <br />o. 4 193 <br />it <br />a ST OF <br />LORI - <br />C. <br />'AWAM# PROFESSIONAL ENGINEERS <br />3203 QUEEN PALM DRIVE <br />TAMPA, FLORIDA 33619 <br />PHONE (813) 241-6488 <br />FAX (813) 241-6498 <br />Board of 111,11 oferrd E, 9111 - Uoorw 0 2= <br />V "m <br />JW�UAO <br />U <br />U <br />U <br />U <br />S�� N <br />N <br />00 <br />U o, <br />OM <br />a <br />M � N <br />�, M o <br />o 6"Z <br />C) <br />a� <br />N o •� <br />00w0-0 �_1 <br />in %10 <br />1-4 0 0 <br />0d (11 <br />I I <br />I <br />0 0 <br />1-4 <br />o <br />Z W <br />a w <br />U 0 <br />D <br />a ILLI <br />as <br />Project No. 15017.00 <br />I'm <br />0 <br />02015 BH1PK Architects, Inc. I <br />