Laserfiche WebLink
N <br />0 <br />.r <br />N <br />O N <br />Go -0 <br />co <br />b�o <br />F_ ------- <br />I 24V <br />I <br />I I <br />I � <br />I I <br />I � <br />I � <br />I I <br />I � <br />I � <br />I 1 i <br />I � <br />I � <br />I � <br />I O � <br />I � <br />j y jCONCEALED 3/8" FLEX W/3 <br />1/2" EMT W/3 #12 THHN CU <br />#12 THHN CU <br />r -t <br />1 { <br />+ - - + <br />FROM BRANCH CIRCUIT TO EXHAUST FAN <br />SPEED CONTROL PROVIDED BY <br />10 MECHANICAL CONTRACTOR AND <br />INSTALLED BY ELECTRICAL CONTRACTOR <br />4" SQ BOX W/EXTENSION RING <br />0 & 1 G SWITCH RS COVER <br />O3 RIBUIS PILOT CONTROL RELAY PROVIDED BY <br />MECHANICAL CONTRACTOR AND INSTALLED BY <br />ELECTRICAL CONTRACTOR <br />® THERMOTSAT CABLE P&I MECHANICAL CONTRACTOR <br />EXHAUST FAN <br />CONTROL DETAIL <br />MC CABLE <br />MC CABLE IS ALLOWED ON THIS PROJECT SUBJECT TO THE <br />LIMITATIONS SET FORTH BELOW AND ACCORDING TO PARAMETERS <br />SET FORTH IN NEC 70 ARTICLE 330. <br />1 MC CABLE CAN BE USED TO CONNECT LUMINAIRES <br />INSTALLED WITHIN AN ACCESSIBLE CEILING TO A JUNCTION BOX <br />WHEN THE LENGTH DOES NOT EXCEED SIX FEET. IN SUCH <br />INSTALLATIONS, THE MC CABLE FITTINGS SHALL BE PERMITTED <br />AS MEANS OF CABLE SUPPORT. <br />2 MC CABLE CAN BE USED TO CONNECT DEVICES <br />INSTALLED CONCEALED INSIDE A WALL CAVITY. <br />3 MC CABLE CAN BE USED TO CONNECT THE LAST DEVICE <br />IN A CIRCUIT TO A HOMERUN JUNCTION BOX MOUNTED ON OR <br />ADJACENT TO THE FRAMING TOP PLATE. <br />4 MC CABLE USE SHALL BE LIMITED TO #12 AND #10 <br />COPPER CONDUCTORS. <br />5 MC CABLE SHALL BE INSTALLED PARALLEL OR <br />PERPENDICULAR TO BUILDING LINES AND FRAMING MEMBERS. <br />6 MC CABLE SHALL BE USED FOR BRANCH CIRCUITS ONLY. <br />HOMERUNS SHALL BE IN CONDUIT. <br />7 MC CABLE SHALL BE PROTECTED WHEN INSTALLED <br />THROUGH OR RUN PARALLEL TO FRAMING MEMBERS SO THAT <br />THE NEAREST OUTSIDE SURFACE IS AT LEAST 1 1/4" FROM <br />THE NEAREST EDGE OF THE FRAMING MEMBER. WHEN THIS <br />DISTANCE CAN NOT BE MAINTAINED, THE CABLE SHALL BE <br />PROTECTED FROM SCREW OR NAIL PENETRATION BY A STEEL <br />PLATE, SLEEVE OR EQUIVALENT OF AT LEAST 1/16" THICK. <br />8 THE RADIUS OF INNER BEND IN CORRUGATED SHEATH MC <br />CABLE SHALL BE GREATER THAN 4" FOR MC CABLE CONTAINING <br />#12 CONDUCTORS AND 4.5" FOR MC CABLE CONTAINING #10 <br />CONDUCTORS. <br />9 MC CABLES SHALL BE SUPPORTED AT LEAST EVERY 6' & <br />WITHIN 12" OF EVERY BOX, FITTING OR OTHER TERMINATION. <br />10 MC CABLE SHALL BE REPLACED WHEN THE CORRUGATED <br />SHEATH HAS SEPARATED AND IS NO LONGER INTERLOCKED. <br />11 MEDICAL GRADE MC CABLE SHALL BE USED IN PATIENT <br />CARE AREAS BUT NOT IN BUSINESS OFFICES, CORRIDORS, <br />LOUNGES, WAITING ROOMS AND SIMILAR AREAS PER 517.10(B). <br />�-------------------I <br />I <br />I <br />� I <br />I � <br />I � <br />I � <br />I � <br />I � <br />I � <br />I � <br />1 <br />i 0 i <br />L - - i - - - - - - - - - - - - - J <br />J <br />j Y ICONCEALED 3/8" FLEX W/3 <br />11/2" EMT W/3 #12 THHN CU <br />#12 THHN CU <br />r -1 <br />I { <br />+ <br />FROM BRANCH CIRCUIT TO EXHAUST FAN <br />SPEED CONTROL PROVIDED BY <br />O MECHANICAL CONTRACTOR AND <br />INSTALLED BY ELECTRICAL CONTRACTOR <br />4" SQ BOX W/EXTENSION RING <br />& 2G SWITCH RS COVER <br />O3 MOTOR STARTING SWITCH, Sm <br />EXHAUST FAN <br />DISCONNECT DETAIL <br />DEDICATED <br />WORKING SPACE <br />l ^} I INSTALL THIS SIGN ON INSTALL THIS SIGNON THE EXTERIOR <br />A PANEL IN EACH OF EACH <br />TRICAL ROOM ELECTRICAL ROOM <br />6' ABOVE EQUIPMENT OR STRUCTURAL <br />CEILING <br />INSTALL 2' RED AND WHITE FLOOR <br />TAPE, BRADY TOUGHSTRIP #104318, <br />36"/42" DEEP AND WIDTH OF <br />ELECTRICAL EQUIPMENT <br />V �30" MINIMUM OR WIDTH OF EQUIPMENT <br />36" FOR VOLTAGE LESS THAN 300V <br />42" FOR VOLTAGE MORE THAN 300V <br />NEC 110.26(E)- THE SPACE EQUAL TO THE WIDTH AND <br />DEPTH OF THE EQUIPMENT AND EXTENDING TO A HEIGHT OF <br />6' ABOVE THE EQUIPMENT SHALL BE DEDICATED TO THE <br />ELECTRICAL INSTALLATION. <br />SPD INSTALLATION <br />GROUND NEUTRAL <br />BUS BUS <br />NEUTRAL <br />GROUND - SPD <br />PHASE CONDUCTORS <br />1. CONNECT SPD TO BREAKER AS FOLLOWS: <br />2P30 FOR 1 PHASE <br />3P30 FOR 3 PHASE <br />2. RELOCATE BREAKER IN PANEL AS NECESSARY TO <br />PROVIDE THE SHORTEST WIRE LENGTH TO SPD. <br />3. DIRECT CONNECTION TO BUS IS NOT PERMITTED. <br />4. USE A CHASE NIPPLE CONNECTION VIA KNOCKOUT. <br />5. USE #10 AWG OR LARGER CONDUCTORS. <br />6. LIMIT WIRE LENGTH TO 18" OR LESS. <br />7. KEEP WIRE FREE OF ANY SHARP BENDS. <br />8. SPD TO BE MODULAR, UL 1449 3RD EDITION LISTED, <br />9. SPD TO BE UL 1283 CERTIFIED <br />10. SPD SHALL BE LABELED WITH 2O0kA SCCR <br />11. SPD SHALL BE UL LABELED AS TYPE 1 <br />12. PEAK SINGLE IMPLUSE SURGE CURRENT RATING <br />250kA PER PHASE <br />13. 700V <br />G <br />- ®® <br />EACH TV SYMBOL Q REPRESENTS PROVIDING AND INSTALLING A <br />RECESSED TV BOX WITH A TERMINATED DATA AND/OR COAXIAL JACK <br />AS PER RISER DIAGRAM. <br />THE SYMBOL ALSO REPRESENTS PROVIDING AND INSTALLING A <br />DUPLEX RECEPTACLE AS SCHEDULED THAT IS NOT SHOWN ON THE <br />PLANS AND SHALL BE CIRCUITED AS SHOWN OR CONNECTED TO AN <br />ADJACENT UN -SWITCHED RECEPTACLE CIRCUIT. THE RECEPTACLE <br />SHALL BE TAMPER RESISTANT IF IN A RESIDENTIAL OR LODGING <br />OCCUPANCY. <br />THE BOX SHALL BE INSTALLED AT THE HEIGHT PER ARCHITECTURAL <br />ELEVATIONS AND SHALL BE INSTALLED SO IT IS FULLY HIDDEN <br />BEHIND THE FLUSH MOUNTED TV WHERE IT DOES NOT INTERFERE <br />WITH THE MOUNTING SYSTEM. <br />THIS RECEPTACLE SHALL BE LOCATED AT LEAST 6' FROM ANY WET <br />AREA THAT WOULD REQUIRE A GFI RECEPTACLE AND IT IS NOT TO <br />BE INCLUDED AS A CODE REQUIRED RECEPTACLE OR ACCESSIBLE. <br />CONTRACTOR SHALL PROVIDE THE APPROPRIATE BOX AND/OR <br />FIREPROOFING TO MAINTAIN FIRE RATING OF WALL IF APPLICABLE. <br />TV CONNECTION <br />M <br />MC <br />ar <br />o J <br />M tK' NE 6' TOTAL UNM <br />z 3, <br />I: <br />M <br />W <br />,i• <br />LIGl1DTx>'I1T w/o METAL <br />pc iNTE EVERY 10' pX <br />PC <br />212"-3" 8' <br />STRAPPING <br />TELEPHONE BOARD <br />1 1/2" x 2' STRUT W/STRAPS <br />CEIM <br />2" EMT W/BUSHING BOTH ENDS <br />GROUNDING BAR <br />GROUNDING CONDUCTOR <br />4'x8' READYSPEC BACKBOARD <br />BRANCH CIRCUIT <br />QUAD RECEPTACLE 0 48" TOB <br />4" 2 HOLE STRAP <br />AS BUILT <br />HOLDER <br />4" x 25" PVC <br />GLUE CAP TO PIPE & DRILL <br />3-1/4" DRAIN HOLES <br />GRADE <br />DATACOM LEGEND <br />011 DEVICE DATA, 3/4" EMT & 4"SQ W/SG PLASTER RING <br />02 2 DEVICE DATA, 3/4" EMT & 4"SQ W/2G PLASTER RING <br />24 DEVICE DATA, 1" EMT & 4"SQ W/2G PLASTER RING <br />0 2 DEVICE VOICE/DATA, 3/4" EMT & 4"SQ W/SG RING <br />® WIRELESS ACCESS POINT 4" SQ BOX, CHASE NIPPLE & <br />BUSHING ATTACHED TO STRUCTURE ABOVE CEILING <br />CONDUIT OR CHASE INSTALLATION <br />P&I EMT FROM DEVICE ® 16" BOB TO ACCESSIBLE <br />® CEILING SPACE, W/90 AT EXTERIOR WALLS ONLY & <br />INSTALL ARLINGTON EMT INSULATING BUSHING <br />❑ P&I HUBBELL LOW VOLTAGE MOUNTING PLATE #8017 AT <br />16" BOB W/PULL STRING TO ACCESSIBLE CEILING SPACE <br />CONDUCTOR AND DEVICE INSTALLATION <br />® CONDUCTORS AND DEVICE TERMINATIONS ARE BY OTHERS <br />P&I ONE CAT6 CONDUCTOR FROM EACH DEVICE TO DATA <br />BOARD. PULL CABLE TO FLOOR AT BOTH ENDS AND <br />❑ CUT. TERMINATE DEVICE W/ CAT6A RJ45 DEVICE AND <br />IDENTIFY EACH CONDUCTOR AT BOTH ENDS <br />NEC 70 <br />THE ENGINEER OF RECORD HAS DESIGNED THIS PROJECT <br />TO MEET THE MINIMUM STANDARDS SET FORTH BY THE <br />NATIONAL ELECTRICAL CODE, 2014. <br />AS THE STATE OF FLORIDA HAS ADOPTED THE 2011 NEC, <br />THE INSTALLATION SHALL MEET ANY 2011 CODE SECTION IF <br />MORE STRINGENT. <br />LUMINAIRE LEGEND <br />A �° <br />2'x4' CEILING MOUNT <br />A[] <br />2'X2' CEILING MOUNT <br />A 0 <br />1'X4' CEILING MOUNT <br />As— <br />4' WALL MOUNT <br />AOA❑ <br />CEILING MOUNT <br />A 2A 4 <br />Wes- MOUNT <br />A <br />SURFACE MOUNT STRIP <br />X ® m X <br />EXIT SIGN, SINGLE OR DOUBLE FACE <br />BATTERY EGRESS WALL MOUNT <br />lc!n? <br />EXIT/EGRESS <br />A v <br />TRACK LIGHTING <br />LIGHTING CONTROLS <br />INSTALL FULL NEUTRAL TO ALL SWITCHING DEVICES. <br />INSTALL ALL AT 48" AFF TOB. <br />$ SINGLE POLE, 20A, 120/277V, HUBBELL 1221 <br />$3 THREE WAY, 20A, 120/277V, HUYBBELL 1223 <br />$4 FOUR WAY, 20A, 120/277V, HUBBELL 1224 <br />$T TWIST TIMER, 5 MINUTE, NO HOLD, INTERMATIC FF5M <br />® PHOTOCELL, TORK K2101 <br />0 TIME SWITCH, TORK DZS200BP <br />$p SWITCH WITH PILOT LIGHT. LEVITON 1221-PLR <br />$M MOTOR STARTING SWITCH. LEVITON N1302-DS <br />CEILING MOUNT LINE VOLTAGE OCCUPANCY SENSOR <br />Fo-sl WATTSTOPPER DT-355 <br />os WALLMOUNT LINE VOLTAGE OCCUPANCY SENSOR <br />WATTSTOPPER WS-250 <br />ED WALL MOUNT LINE VOLTAGE FAN/LIGHT OCCUPANCY <br />SENSOR SENSORSWITCH WSD PDT 2P FAN <br />COSCEILING MOUNT LOW VOLTAGE OCCUPANCY SENSOR <br />WATTSTOPPER DT-300 <br />® WALL MOUNT LOW VOLTAGE OCCUPANCY SENSOR <br />WATTSTOPPER DW-100 <br />pp LOW VOLTAGE OCCUPANCY SENSOR POWER PACK <br />WATTSTOPPER BZ-50 <br />® CEILING MOUNT LOW VOLTAGE DAYLIGHTING SENSOR <br />WATTSTOPPER LS-301 <br />®DAYLIGHTING REMOTE CONTROLLER <br />WATTSTOPPER LRS-301S <br />GENERAL NOTES <br />SHADED SYMBOLS INDICATE LUMINAIRES PROVIDED WITH <br />EMERGENCY BACKUP POWER AND ARE SHOWN AS <br />LIFE SAFETY BRANCH CIRCUIT <br />E] <br />CRITICAL BRANCH CIRCUIT <br />BATTERY BACK UPIm <br />SYMBOLS SHOWN WITH DASHED LINES INDICATE EXISTING <br />WHERE THE SUBSCRIPTS INDICATE THE FOLLOWING: <br />ER - Existing to Remain <br />XD - eXisting to be Demolished <br />EL - Existing to be reLocated <br />EP - Existing to be rePlaced <br />LINETYPE LEGEND <br />�--� HOMERUN - UON, J" CONDUIT W/3 #12 THHN <br />LP_1 CU CONCEALED IN WALL OR ABOVE CEILING <br />WITH PANEL AND CIRCUIT NUMBER SHOWN <br />EXISTING CONDUIT <br />FLEXIBLE CONDUIT <br />- - - - - - LUMINAIRE SWITCHLEG <br />•................ EMERGENCY CIRCUIT <br />CAT 6A CABLING <br />OH— OVERHEAD LINE <br />ABBREVIATIONS <br />A <br />AMPERE <br />AC <br />ABOVE COUNTER <br />AF <br />AMPERE FRAME <br />AFF <br />ABOVE FINISHED FLOOR <br />AFCI <br />ARC -FAULT CIRCUIT INTERRUPTER <br />AFG <br />ABOVE FINISHED GRADE <br />AHU <br />AIR HANDLING UNIT <br />AIC <br />AMPS INTERRUPTING CAPACITY <br />AL <br />ALUMINUM <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />A/V <br />AUDIO/VISUAL <br />AWG <br />AMERICAN WIRE GAUGE <br />BOB <br />BOTTOM OF BOX <br />C <br />CONDUIT <br />CAT <br />CATEGORY <br />CB <br />CIRCUIT BREAKER <br />CH <br />CHILLER <br />CKT <br />CIRCUIT <br />CL <br />CENTER LINE <br />CLG <br />CEILING <br />CU <br />COPPER <br />DWG <br />DRAWING <br />EG, EGG <br />EQUIPMENT GROUND BAR <br />EC <br />ELECTRICAL CONTRACTOR <br />EF <br />EXHAUST FAN <br />EM <br />EMERGENCY <br />EMT <br />ELECTRICAL METALLIC TUBING <br />ENCL <br />ENCLOSURE <br />EWH <br />ELECTRIC WATER HEATER <br />EXIST, EX <br />EXISTING <br />FA <br />FIRE ALARM <br />FBO <br />FURNISHED BY OWNER <br />FCP <br />FIRE ALARM CONTROL PANEL <br />FACC <br />FIRE ALARM COMMAND CENTER <br />FATC <br />FIRE ALARM TERMINAL CABINET <br />FO <br />FIBER OPTIC <br />GFI, GFCI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GND,G <br />GROUND <br />HOA <br />HAND -OFF -AUTO <br />HACR <br />HEATING/AIR CONDITIONING -RATED <br />HID <br />HIGH INTENSITY DISCHARGE <br />HPF <br />HIGH POWER FACTOR <br />HPS <br />HIGH PRESSURE SODIUM <br />HP <br />HORSEPOWER <br />IG <br />ISOLATED GROUND <br />IPTV <br />INTERNET PROTOCOL TELEVISION <br />J, JB JUNCTION BOX <br />KCMIL THOUSAND CIRCULAR MILS <br />KVA <br />KILOVOLT AMPERE <br />KW <br />KILOWATT <br />MCB <br />MAIN CIRCUIT BREAKER <br />MCC <br />MOTOR CONTROL CENTER <br />MDP <br />MAIN DISTRIBUTION PANEL <br />MH <br />METAL HALIDE <br />MLO <br />MAIN LUGS ONLY <br />MTD <br />MOUNTED <br />NC <br />NORMALLY CLOSED <br />NEC <br />NATIONAL ELECTRICAL CODE <br />NEMA <br />NATIONAL ELECTRICAL MANUF. ASSOCIATION <br />NF <br />NON -FUSED <br />NFPA <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NIC <br />NOT IN CONTRACT <br />NL <br />NIGHT LIGHT <br />NO <br />NORMALLY OPEN <br />NTE <br />NOT TO EXCEED <br />0 <br />PHASE <br />POE <br />POWER OVER ETHERNET <br />P&I <br />PROVIDE AND INSTALL <br />PB <br />PUSHBUTTON <br />PC <br />PHOTOCELL <br />PNL <br />PANEL <br />POTS <br />PLAIN OLE TELEPHONE SYSTEM <br />PVC <br />POLYVINYL CHLORIDE CONDUIT <br />RGS <br />RIGID GALVANIZED STEEL CONDUIT <br />SCA <br />SHORT CIRCUIT AVAILABLE AMPS <br />SG <br />SINGLE GANG <br />SPD <br />SURGE PROTECTIVE DEVICE AS INDICATED <br />STP <br />SHIELDED TWISTED PAIR CABLE <br />STIR <br />STRANDED WIRE <br />SW <br />SWITCH <br />SWBD <br />SWITCHBOARD <br />TC <br />TIME CLOCK <br />TOB <br />TOP OF BOX <br />TP <br />TWISTED PAIR CABLE <br />TR <br />TAMPER RESITANT <br />TS <br />TIME SWITCH <br />TYP <br />TYPICAL <br />UG <br />UNDERGROUND <br />UH <br />UNIT HEATER <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />LION <br />UNLESS OTHERWISE NOTED <br />VAV <br />VARIABLE AIR VOLUME <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />V <br />VOLT <br />WAP <br />WIRELESS ACCESS POINT <br />WP <br />WEATHER PROOF <br />WR <br />WEATHER RESISTANT <br />XFMR TRANSFORMER <br />2G TWO GANG <br />DEVICE COLOR <br />ALL DEVICES INCLUDING SWITCHES & RECEPTACLES ARE <br />WHITE IN COLOR. <br />ALL DEVICE PLATES ARE STAINLESS STEEL AND SHALL BE <br />LABELED WITH PANEL AND CIRCUIT DESIGNATIONS. <br />ALL DATACOM AND TV OUTLETS ARE WHITE. <br />ELECTRIC NOTES <br />1 CONTRACTOR SHALL BE LICENSED BY THE STATE OF FLORIDA ACCORDING TO CHAPTER <br />489, FLORIDA STATUTES AND SHALL PROVIDE FOR AND ACQUIRE ALL NECESSARY <br />PERMIT(S) AND INSPECTIONS AS MAY BE REQUIRED BY THE AUTHORITY(IES) HAVING <br />JURISDICTION. <br />2 INSTALLATION SHALL MEET OR EXCEED THE MINIMUM REQUIREMENTS OF THE FLORIDA <br />BUILDING CODE, 2010 AND NFPA 70, NATIONAL ELECTRICAL CODE, 2014 UNLESS THE <br />AN APPLICABLE SECTION OF THE ADOPTED NEC IS MORE STRINGENT. <br />3 THE CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR NECESSARY TO PROVIDE <br />FOR THE INSTALLATION OF A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. <br />4 THE CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE CONDITIONS <br />AND CONTRACT DOCUMENTS. <br />5 PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL COORDINATE WITH THE <br />APPROPRIATE UTILITIES FOR METERING, TRANSFORMER AND SERVICE CONNECTION <br />REQUIREMENTS. <br />6 PROVIDE ANY AND ALL NECESSARY TEMPORARY CONNECTIONS OF EQUIPMENT, <br />DEVICES OR LUMINAIRES AS MAY BE REQUIRED FOR CONSTRUCTION. <br />7 CONDUIT SHALL BE INSTALLED CONCEALED, RECESSED AND IN A NEAT AND <br />WORKMANLIKE MANNER. ALL CONDUIT SHALL BE INSTALLED PARALLEL OR <br />PERPENDICULAR TO BUILDING LINES. EXPOSED CONDUIT ON EXTERIOR WALLS ON <br />FINISHED WALLS IS PROHIBITED. <br />8 CONDUIT SHALL BE EMT AND FITTINGS SHALL BE STEEL. FOR UNDERGROUND AND <br />UNDER SLAB INSTALLATIONS, CONDUIT SHALL BE PVC OR IMC W/AN ASPHALTIC <br />COATING. ENT OR "SMURF" TUBING IS NOT APPROVED. <br />9 ALL CONDUIT CUT ENDS SHALL BE REAMED PER NEC 358.28. <br />10 SEAL ALL CONDUITS WHERE THE CONDUIT CONNECTS AN INTERIOR CONDUIT BODY TO <br />AN EXTERIOR CONDUIT BODY OR LUMINAIRE. <br />11 PVC CONDUIT INSTALLED UNDERGROUND SHALL BE A LEAST 12" UNDER SIDEWALKS, <br />24" UNDER PARKING LOTS AND DRIVEWAYS AND 18" IN ALL OTHER LOCATIONS PER <br />NEC TABLE 300.5. <br />12 ALL UNDERGROUND CONDUITS AND CONDUCTORS SHALL BE MARKED WITH A WARNING <br />RIBBON AT LEAST 12" ABOVE THE CONDUIT OR CONDUCTOR PER NEC 300.5(3). <br />13 CONDUCTORS IN CONDUIT INSTALLED EXPOSED TO DIRECT SUNLIGHT SHOULD BE <br />DE -RATED DEPENDING ON THE DISTANCE BETWEEN THE ROOF AND BOTTOM OF <br />CONDUIT PER NEC 310.15(B)3(C) AND SHOULD BE INSTALLED USING THE <br />APPROPRIATE SPACER. <br />14 PROVIDE AN INDEPENDENT MEANS OF SUPPORT FOR CONDUIT INSTALLED ABOVE A <br />CEILING WHERE THEY ARE DISTINGUISHABLE BY COLOR, TAGGING OR OTHER EFFECTIVE <br />MEANS. THE CEILING SUPPORT SYSTEM SHALL BE PERMITTED TO SUPPORT BRANCH <br />CIRCUIT WIRING WHERE INSTALLED IN ACCORDANCE WITH THE CEILING <br />MANUFACTURER'S INSTRUCTIONS. <br />15 PROVIDE A MINIMUM 1 1 /2" SPACE BETWEEN METAL CORRUGATED SHEET ROOF <br />DECKING AND ANY CABLE, CONDUCT OR BOX PER NEC 300.4(E). <br />16 PROVIDE AN INSULATED THROAT FITTING OR PLASTIC BUSHING FOR ALL 1" AND <br />LARGER CONDUIT TERMINATIONS IN PANEL BOARDS, LOAD CENTERS, WIREWAYS AND <br />DISCONNECT SWITCHES. <br />17 PROVIDE GROUNDING BUSHINGS FOR ANY CONDUIT TERMINATIONS AT PANELS AND <br />DISCONNECTS USING AT ECCENTRIC OR CONCENTRIC KNOCKOUTS OR WHEN REDUCING <br />WASHERS ARE USED. BOND ALL JUNCTION AND PULL BOXES TO GROUND. <br />18 ALL WIRE SHALL BE COPPER, THHN, THWN OR XHH. MINIMUM WIRE SIZE IS #12. <br />AMPACITIES ARE CALCULATED USING THE 75'C COLUMN. <br />19 ALL 20 AMP BRANCH CIRCUIT HOMERUNS OVER 100 FEET SHALL BE #10. SEE <br />SCHEDULE THIS SHEET FOR LENGTH LIMITATIONS. <br />20 ALL WIRING DEVICES SHALL BE TERMINATED AT THE SCREW IN A CLOCKWISE <br />DIRECTION. THE PUSH -IN TERMINATIONS SHALL NOT BE USED. <br />21 VOLTAGE DROP SHALL NOT EXCEED 2% FOR BRANCH AND 2% FOR FEEDER CIRCUITS. <br />22 ALL CONDUCTORS SHALL BE COLOR CODED AS PER THE INDUSTRY STANDARD. <br />120/208V 277/480V <br />PHASE A BLACK BROWN <br />PHASE B RED ORANGE <br />PHASE C BLUE YELLOW <br />23 INSTALL A FULL SIZE NEUTRAL TO ALL DEVICES INCLUDING SWITCHES. <br />24 TERMINATE NO MORE THAN ONE WIRE PER TERMINAL PER NEC 110.14A. <br />25 CONDUCTORS SHALL BE TWISTED TOGETHER PRIOR TO INSTALLATION OF TWIST ON <br />CONNECTORS. <br />26 REFER TO DATA/COMM DETAIL FOR EXTENT OF INSTALLATION REQUIRED. <br />27 ALL BOXES SHALL BE A 4" SQUARE METAL BOX WITH THE APPROPRIATE RING. THE <br />MAXIMUM GAP AROUND ANY RECESSED BOX SHALL NOT EXCEED 1/8" AND THE <br />MAXIMUM SETBACK SHALL NOT EXCEED 1/4" PER NEC 314.20 & 314.21. <br />28 TO MEET ADA GUIDELINES AND MAINTAIN COURSE SPACING, ELECTRICAL OUTLET BOXES <br />SHALL BE INSTALLED 48" TO TOP OF BOX OR 16" TO BOTTOM OF BOX. OUTLET <br />BOXES INSTALLED OVER COUNTERS SHALL BE INSTALLED AT 42" TO BOTTOM OF BOX. <br />29 VERIFY DOOR SWINGS AND BACKSPLASH HEIGHTS AT ROUGH IN. <br />30 STAGGER BACK TO BACK WALL BOXES IN ALL WALLS BY AT LEAST ONE STUD. <br />31 PROVIDE TAMPER RESISTANT AND WEATHER RESISTANT RECEPTACLES WHERE REQUIRED <br />BY NEC 406.4. <br />32 PROVIDE IN USE COVERS FOR ELECTRICAL DEVICES INSTALLED IN DAMP AND WET <br />AREAS WITH THE APPROPRIATE DUTY PER NEC 406.9. <br />33 ALL PANEL BOARD BUS SHALL BE COPPER. <br />34 EACH LOAD CENTER AND DISCONNECTING MEANS SHALL BE MARKED TO INDICATE ITS <br />PURPOSE, FEED, AND OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED PER NEC 110.22. <br />35 PROVIDE A TYPED PANEL SCHEDULE REFLECTING INSTALLED CONDITIONS FOR ALL <br />PANEL BOARDS WITH "SPACE" OR "SPARE" WRITTEN IN PENCIL. <br />36 INSTALL LOAD CENTERS AND DISCONNECTS SO THAT AT LEAST 3% FEET OF WORKING <br />SPACE CAN BE MAINTAINED PER NEC 110.26 AND DETAIL THIS SHEET. <br />37 EQUIPMENT SHALL NOT PROTRUDE MORE THAN 6" INTO THE REQUIRED WORKING <br />SPACE AROUND ELECTRICAL EQUIPMENT. <br />38 "TYPICAL" NOTES APPLY TO ALL SIMILAR SITUATIONS. <br />39 PROVIDE A DISCONNECTING MEANS FOR EACH WATER HEATER PER FPC 504.3. <br />40 LABEL WITH A SHARPIE ALL JUNCTION BOX COVERS WITH CIRCUITS DESIGNATION <br />CONTAINED WITHIN. <br />41 PROVIDE OPERATING AND INSTALLATION INSTRUCTIONS TO THE OWNER FOR ALL <br />INSTALLED EQUIPMENT. <br />42 DEVICES IN VICINITY OF GAS CYLINDERS SHALL BE AT INSTALLED 60" TO BOTTOM OF <br />BOX PER NFPA 99. <br />43 AN FS BOX IS NOT APPROVED AS A SUPPORT FOR A LUMINAIRE. <br />44 PROVIDE A DISCONNECTING MEANS IN ALL FLUORESCENT LUMINAIRES THAT ARE <br />INSTALLED NEW OR REPAIRED. <br />45 LUMINAIRES INSTALLED IN SUSPENDED CEILINGS SHALL BE FASTENED TO THE <br />CEILING FRAMING MEMBERS IN ACCORDANCE WITH NEC 410.36. <br />46 PROVIDE DOCUMENTATION WITH CLOSE OUT DOCUMENT PROVING THAT ANY AND ALL <br />BALLASTS AND LAMPS HAVE BEEN RECYCLED BY AN APPROVED RECYCLING VENDOR. <br />47 PROVIDE THE APPROPRIATE FIRE STOP SYSTEM AND/OR FIRE CAULK AT ANY <br />PENETRATION OF A RATED VERTICAL ASSEMBLY. <br />48 PENETRATIONS OF A RATED HORIZONTAL ASSEMBLY WITH A METAL CONDUIT NOT <br />EXCEEDING 6 INCH NOMINAL DIAMETER, INSTALL CONCRETE, GROUT, OR MORTAR THE <br />FULL THICKNESS OF THE FLOOR AS REQUIRED BY FBC 713.4.1.1 SO TO MAINTAIN <br />THE FIRE RESISTANCE RATING. FOR MULTIPLE PENETRATIONS, REFER TO THE <br />FLORIDA BUILDING CODE. <br />49 ALL JUNCTION BOXES ARE TO BE ACCESSIBLE PER NEC ARTICLE 100. <br />50 NOT ALL ITEMS, NOTES, DETAILS, ABBREVIATIONS, SCHEDULES AND LEGENDS ON THE <br />SHEET MAY BE APPLICABLE TO THIS PROJECT. <br />51 CONDUIT TERMINATION AT NEMA3R ENCLOSURES SHALL BE WITH MYERS HUBS FOR <br />TOP PENETRATIONS AND LIQUID TIGHT SEALING RINGS OR SEALING LOCKNUTS FOR <br />BOTTOM AND SIDE PENETRATIONS. <br />52 FOR ALL LUMINAIRES INSTALLED IN A CEILING GRID SYSTEM, INSTALL LISTED CLIPS <br />SECURELY FASTENING THE LUMINAIRE TO THE CEILING FRAMING MEMBERS PER NEC <br />70-410.36(B). <br />POWER LEGEND <br />0 JUNCTION BOX <br />© LIGHT SUPPORT BOX, 50LBS STATIC <br />Q FAN SUPPORT BOX, 70LBS DYNAMIC <br />HP ELECTRIC MOTOR/EXHAUST FAN <br />Fs-p-51 SURGE PROTECTION DEVICE <br />0 PUSHBUTTON 48" AFF TOB <br />Ii PANEL BOARD <br />El <br />TRANSFORMER <br />❑' DISCONNECT, 48" AFF CENTER <br />NP COMBINATION STARTER/DISCONNECT, 48" AFF CENTER <br />® VARIABLE FREQUENCY DRIVE, 48" AFF CENTER <br />' ENCLOSED CIRCUIT BREAKER <br />All DEVICES ARE MAIM 16" AFF BOB UON. <br />ABOVE COUNTER DEVICES ARE INDICATED BY INTERIOR SHADING AND ARE <br />RSTA110 AT 42" AFF BOB UON. <br />9 RECEPTACLE, 20A, HUBBELL 8300 <br />RECEPTACLE, AC, 20A, HUBBELL 8300 <br />IGQ , <br />LEVITON IG5362 <br />TOQQ DECORA, TAMPER RESISTANT, 20A, LEVITON TBR20 <br />0 DECORA, TAMPER RESISTANT, USB, 20A, LEVITON T5832 <br />USB <br />0 DECORA, GFCI, WEATHER RESI, 20A, LEVITON WR899 <br />wpri <br />GFCI, HUBBELL GFR83000HILA <br />GFl <br />q QUAD RECEPTACLE - DOUBLE DUPLEX, 20A, 120V <br />up QUAD RECEPTACLE, AC, W/1 USB RECEPTACLE <br />® SPECIAL RECEPTACLE <br />1p SWITCH CONTROLLED DUPLEX RECEPTACLE, 20A, 120V <br />w/ CONTROLLED RECEPTACLE MARKING PER 406(E) <br />® DUPLEX RECEPTACLE IN FLOOR BOX <br />Mm <br />QUAD RECEPTACLE IN FLOOR BOX <br />0 DUPLEX RECEPTACLE AND DATA IN FLOOR BOX <br />0 QUAD RECEPTACLE AND DATA IN FLOOR BOX <br />DR <br />@ 30A, 240V, 4 WIRE DRYER RECEPTACLE, LEVITON 279 <br />R� 50A, 140V, 4 WIRE RANGE RECEPTACLE, LEVITON 278 <br />TWIST LOCK RECEPTACLE, NEMA LX-XXR <br />Q CLOCK RECEPTACLE, LEVITON 5261-CH 0 96" BOB <br />'0 1 • <br />NFPA 1, 2010 UNIFORM FIRE CODE, FL EDITION <br />NFPA 20, 2010 FIRE PUMPS <br />NFPA 70, 2014 NATIONAL ELECTRICAL CODE <br />NFPA 72, 2010 FIRE ALARM & SIGNALING <br />NFPA 99, 2012 HEALTH CARE FACILITIES <br />NFPA 101, 2012 LIFE SAFETY CODE, FL EDITION <br />NFPA 110, 2010 EMERGENCY & STANDBY SYSTEMS <br />NFPA 720, CARBON MONOXIDE DETECTION <br />NFPA 780, LIGHTNING PROTECTION <br />NFPA 2001, 2012 CLEAN AGENT <br />2010 GUIDELINES FOR DESIGN AND CONSTRUCTION FOR <br />HEALTH CARE FACILITIES <br />2014 FLORIDA BUILDING CODES <br />CHAPTER 69A, FLORIDA ADMINISTRATIVE CODE <br />I)RAWM INDEX <br />E-1.0 LEGEND, ABBREVIATIONS AND GENERAL NOTES <br />E-2.0 DEMOLITION AND NEW FEEDER PLAN <br />E-3.0 NEW CONSTRUCTION <br />- 0- <br />SCHEDULES <br />PORTABLE M I P N <br />E-6.0 MRI ELECTRICAL INSTALLATION 1 <br />E-6.1 MRI ELECTRICAL INSTALLATION <br />♦ , <br />FCD MO,Q <br />' <br />0193 "1 <br />ER <br />i O�COR10P •������ <br />NAL �?\��� <br />1111111\\\ <br />U <br />H <br />4� <br />U <br />N <br />00 <br />U � <br />M <br />N <br />O New <br />3 0 <br />n <br />ci 0 <br />W 0000fw ate, a <br />to <br />0 <br />(U <br />I <br />0 <br />I <br />O <br />0 <br />•� <br />� W <br />f <br />O <br />u <br />Q <br />U <br />Q <br />a <br />b <br />-v <br />6 ti <br />CIO <br />y ft3 N <br />A <br />IR <br />A <br />T� ,C4 <br />4� <br />CC3 <br />w <br />C <br />rW � <br />V <br />0 <br />. 4 <br />W <br />W <br />to-4 <br />H � <br />W � <br />M� p4 <br />Project No. 15017.00 <br />E1*0 <br />02015 BH/PK Architects, Inc. <br />$DATE$ $TIME$ $FILEA$ <br />