BFE 6' Diameter Virtual Skylight <br />WIRING DIAGRAM <br />N <br />N <br />00 <br />N <br />0 <br />o <br />N _ <br />00 <br />N <br />0 <br />LUMINAIRE SCHEDULE <br />TAG <br />QTY <br />DESCRIPTION <br />MANUFACTURER <br />CATALOG NUMBER <br />VOLTS <br />LAMP <br />TYPE <br />FIXTURE <br />VA <br />LUMENS <br />MOUNT <br />LOCATION <br />NOTES <br />TAG <br />A <br />2 <br />2'X2' LED I/D <br />HE WILLIAMS <br />DIS SS LEDPH36/840 WPR UNV <br />UNV <br />LED <br />64 <br />3600 <br />RECESSED <br />CONTROL <br />A <br />B <br />2 <br />2'X2' LED <br />HE WILLIAMS <br />50 G S22-LED'UT41/840 A AF12125 UNV <br />UNV <br />LED <br />47 <br />4100 <br />RECESSED <br />STORAGE <br />B <br />C <br />3 <br />2'X4' LED <br />HE WILLIAMS <br />50 G S24 LED'UT 90/840 A AF12125 UNV <br />UNV <br />LED <br />56 <br />6000 <br />RECESSED <br />EQUIP <br />C <br />D <br />12 <br />LED CAN <br />EVERBRITE <br />XLS3.0 40 120 R C WM <br />120 <br />LED <br />45 <br />2028 <br />RECESSED <br />MRI <br />1 <br />D <br />F <br />1 <br />VIRTUAL SKYLIGHT <br />BFE <br />ENCLOSURE/CAMERA/SERVER <br />120/12VDC <br />LED <br />85.5 <br />SURFACE <br />MRI <br />2 <br />F <br />U <br />1 <br />EG <br />20 <br />L <br />F <br />CO L <br />EL <br />I <br />1 <br />RED IN USE LIGHT <br />BEGHELLI <br />ATX HT LR 1 WSW <br />120 <br />LED <br />WALL <br />ABOVE DOO <br />3 <br />IU <br />0 <br />NOTES <br />1 MRI SAFE LIGHTING SYSTEM. PROVIDE MEDLUXXLS LED LIGHTING DIMMER SYSTEM <br />2 FURNISHED BY OWNER. INSTALLED BE EC. STARTUP BY OTHERS. <br />3 "MRI IN USE" <br />4 <br />5 <br />EXISTING CONDUIT CHASE <br />KEY NOTES <br />O 1 1/4" C. W/3 #2 THHN CU & 1 #8 G. DERATED 30-F FOR <br />ROOFTOP INSTALLATION AT LEAST 3 1/2" ABOVE ROOFTOP PER <br />NEC 310.15(B)(S)(c) <br />O2 100/NF/3/3R 600V DISCONNECT W/STRUT SUPPORT <br />1 <br />O3 I C T LES WITH GFI AND INS TA HEAVY <br />DUTY IN USE OV R <br />4 DISCONNECT MRI CONDENSER AND REMOVE DISCONNECT AND <br />FLEX BACK TO JUNCTION BOX <br />INSTALL SOLID MYERS HUB IN TOP OFFS BOX AND INSTALL <br />O NEW BLANK PLATE AND GASKET. MAKE CONDUCTORS SAFE <br />AND INSTALL SILICONE IN TOP OF CONDUIT. MARK CIRCUIT <br />NUMBERS ON INSIDE OF COVER <br />© EXISTING COVERED CONDUIT CHASE W/COVER TO BELOW <br />(D ARLINGTON RTS4 ROOF TOPPER SUPPORT W/SPACING NTE 3' <br />NEW MRI CHILLER <br />EXISTING LIEBERT CONDENSER TO REMAIN <br />5 <br />J <br />ELECTRICAL PLAN -THIRD FLOOR ROOF <br />SCALE: 1/4"=1'-0" <br />CONTROL ROOM <br />RL D-79 <br />Mod Lux <br />DtMMER <br />pCONTROL <br />V�L1 <br />00 <br />DIM BAZIN <br />DIM A 21 <br />TE R,M I NAI. <br />BLOCK <br />WIRING <br />V✓AC R2 <br />V-lAC - B2 <br />DIM Br'GND = Bi <br />Div A = R1 <br />EQUIPMENT ROOM <br />FACILITY <br />FILTER L OUTPUT <br />N <br />L GND N <br />INPUT1.M <br />XLS SYSTEM <br />RESET SWATCH <br />SIPSTLUTI <br />BRANCH CIRCUIT - 120VAC, 20A <br />( ELECTRICA.L BOX <br />RLD-133, 16VAC <br />/ r 8ELL 71RANSFORMEN <br />PART NO, EW10OM24, 4 <br />#18AWG PLTC GABLE, <br />4 CONDUCTOR. <br />2-TWISTED PAIR, <br />RED 1 B�AC K = R US 1 <br />RED r BLACK = R2W <br />NOT = S! <br />1 MUST BE GROUNDED OR BONDED PER <br />NATIONAL ELECTRIC CODE AND ALL <br />LOCAL ELECTRIC CODES. <br />2- DO NOT CONNECT MORE THAN 32 XLS <br />LIGHTMODULES PER BRANCH CIRCUIT <br />3, DO NOT CCNNECT MORE TMAN 26 XI S <br />LIGHT MODULES PER MEDLUX DILIMER CONTROL. <br />4. FIXTURE J-BOX NOT RATED FOR TFRU WIRING <br />_ DIMMER POWER <br />CABLE: PLTC,18.2 <br />OR EQ UrVALENT <br />OUTPUT <br />R2 c 2 1 <br />I BLfcx <br />Cz IS <br />gi L <br />R1 1 1 <br />BLUE 8 <br />INPUT VIOLET <br />SIGNAL FILTER <br />MRl SHIELD ROOM <br />EMI SEAL GASKET <br />ANDLOCMUT <br />,.— FIL TERED 120 VAC <br />3 C.ONO , N12AW0 <br />xLS — JUNCTION BOX <br />JUNCTION BOX l <br />SEE NOTE 4 <br />(I v 4t 11 —1 n <br />PENETRATION ){ H:OL�4 <br />PANEL <br />L:! <br />RLD-36 CABLES <br />TYP , 10 FT. .- s <br />DIMMER <br />GONNECTICiN <br />BOX <br />LQ <br />Ln <br />J2 <br />RLD-37 CABLE`25 F� <br />` XLS <br />DIMMER CONNECTION JACk LIGHT y <br />— EMI SEAL CASKET AND LOCKNUT FIXTURE <br />WIRE Nt1 <br />20 VAG WIRE <br />LOW VOLTAGE <br />-- PLENUM CABLE <br />LUMINAIRE TYPE D <br />L I G H SING <br />MEDLUX ' MRI GC)Mi3AIIDLL. <br />XLS LIGHTING SYS fEhf DIAGRAM <br />CONTROL ROOM DIMMER INSTALLATION <br />o;i v.n zota <br />MR1 ROOM <br />(6) Pie w; o i'aI is tl' i?�& rater Round Skylight <br />Watts: 14.25 each <br />ELECTRICAL CLOSET <br />NOW-D02FP Q+ uW <br />Constant Voltage Dimmer Switch <br />LEDDimmerlNil - + <br />cl- <br />�1 <br />I <br />I <br />LPV-60-12 <br />Mean Well NEUTAM, <br />+ - <br />12V [ED Power supply I01) <br />urw nleN <br />WATAGE V011AEE <br />'"....... -_ w111NG .V111pKi <br />RF <br />. <br />NOW-D02FP + <br />Filters� <br />Constant Voltage - <br />LET) Dimmer tnzl <br />not <br />include <br />livl>Iecl <br />+ <br />14awg, 2 conductor, 105 <br />strand, CM/CL3 secondary LPV-60-12 <br />wire from connection Mean Well <br />12V LED Power Supply 012) <br />"LEDs are located around the outside radius. - <br />Wiring and Installation Specifics <br />• Each LED Actual Panel Size - 35.5"x 35.08" <br />• Total number of Panels: 6 <br />• Total weight: Approx 116.4lbs <br />• Unit will include: <br />o (6) Pie -Shaped LED Panels cut to size above <br />o (2) Illuni Constant Voltage LED Dimmer <br />o (2) Mean Well* LPV 60-12 12V LED Power Suppler <br />o (1) Leviton Decora" slider dimming control switch (one switch will operate multiple units) <br />o (50ft) of 14awg, 2 conductor, 105 strand, CM/CL3 secondary wire <br />Installation <br />• (1) power supply and (1) dimming module will supply power to (3) Pie -Shaped LED Panels <br />• The primary wiring pre -attached to the LED panel is 20awg wire, which should be connected to the 14awg secondary wire which <br />then should be attached to the RF filter located within the shielded room. <br />• THE (21 RE(UIRED R(FILTERS ARE NOT PROVIDED DY BFE <br />• Within the electrical closet (outside of the shielded room) the secondary wire should be connected to the RF filter; the dimming <br />module and power supply should be wired according to the diagram above. <br />• The control switch is wired as shown above in a convenient place to easily be operated outside of the shielded room. <br />• The LED Panel sits in the Suspended Ceiling "T" track on top of the Image Panel - no mounting or support wires. <br />LUMINAIRE TYPE F <br />MR-21 NEW D02FP DIMMERS <br />FBO <br />"MRI IN USE" LIGHT <br />CAT6A TO IDF 4� \ <br />MR-15 LPV POWER SUPPLIES FBO <br />� T <br />A A NEW SMOKE DETECTOR B / \ <br />1-� \ <br />Fj <br />II i <br />3/4" EMT W/SINGLE MODE cL F cic <br />FIBER MR-17 / _ lD qB <br />ulD3 / 1 <br />O F O <br />I I I <br />I / I <br />(DEL <br />)(D i \ <br />� I � <br />!3 I I <br />ELECTRICAL PLAN -FIRST FLOOR <br />SCALE: 1/4"=1'-O" <br />0 <br />KEY NOTES <br />O CONNECT TO EXISTING CIRCUIT ECHD1-1 <br />O2 RELOCATED RED SWITCH & PLATE SO TO MISS NEW PARTITION <br />O3 RECONNECT LIGHT AT DOOR TO EXISTING EMERGENCY LIGHTING <br />> CIRCUIT <br />> ® RELOCATE EPO TO MISS NEW PARTITION <br />O5 COORDINATE LOCATION OF MDS W/MRI VENDOR <br />- - - - - - - - - - - - - - - - <br />hf <br />�A`I i'� GINEEhING, INC. <br />a : e No. 0193 <br />1 � R <br />'0 A O Qj PROFESSIONAL ENGINEERS <br />3 QUEEN PALM DRIVE <br />/"s OI MPA, FLORIDA 33619 <br />/0 \\PHONE (813) 241-6488 <br />0111 I I I\ ���Boo of mi l 3E 1-bum: III 273M <br />U <br />C!� <br />U <br />ct� <br />• !�1 <br />kr <br />1,D <br />CV <br />O <br />(V <br />00 <br />`71- <br />U <br />O <br />rn <br />M <br />`V <br />O <br />N� o <br />M <br />cC M CV <br />r O <br />U <br />-bCIZI <br />O <br />. w <br />o T-z <br />r_� <br />U <br />O 0 <br />oo " A-. 1 <br />lf� <br />CD <br />I <br />OD <br />0 <br />I <br />0 <br />.2 C, <br />W <br />O <br />U <br />Q <br />U <br />Q <br />n , <br />oG <br />Q <br />Cl) <br />.r__4 <br />� <br />N <br />O <br />ct <br />F—I <br />- .--4 <br />CIO <br />ct <br />rI <br />1 <br />U <br />ct <br />Project No. 15017.00E3.00 <br />02015 BH/PK Architects, Inc. <br />$DATE$ $TIME$ $FILEA$ <br />