<br />DIV151ON I - GENERAL
<br />SECTION 01045 - GUTTING AND PATCHING
<br />Scope: I. Gutting and patching includes cutting into existing construction For the installation
<br />or performance of other work and patching required to restore the surfaces to their
<br />original condition.
<br />o. Unless otherwise specified the requirements For this section also apply to
<br />mechanical and electrical work.
<br />b. Do not cut and patch exposed work in a manner that in the architect/Engineers
<br />opinion results in lessening the buildings aesthetic qualities. Replace any work
<br />judged by the Architect/Engineer to be usually satisfactory.
<br />SECTION 01300 - SUBMITTALS, PRODUCTS, AND SUBSTITUTIONS
<br />Scope: I. Format for submittals. as required For specific type and by individual sections.
<br />2. Types of submittals and number of copies.
<br />o.5hop drawings, reviewed and annotated by the general contractor 6 copies
<br />b. Product data - 6 copies
<br />c. Samples - 2, plus extra samples as required to indicate range of color, finish, and
<br />texture to be expected.
<br />d. Mock-ups - as required in individual sections.
<br />e. Inspection and test reports - 4 copies
<br />F. Warranties - 2 copies
<br />g. Survey data - 2 copies.
<br />h. Closeout submittals - 2 copies
<br />DIVISION 6 - WOOD AND PLASTICS
<br />5ECTION 06100 - ROUGH CARPENTRY
<br />Scope: I. Provide rough carpentry work
<br />a. Noilers, blocking, Furring and sleepers
<br />Products:l. Lumber, finished 4 sides, Iq% maximum moisture content.
<br />a. Light Framing: Construction grade Douglas Fir or southern pine, appearance
<br />grade where exposed.
<br />b. Structural framing and timbers: No. I grade Douglas fir or southern pine,
<br />appearance grade where exposed.
<br />c. Boards: Construction grade
<br />2. Wood For nailers, Furring and sleepers: Construction grade, finished 4 sides,
<br />Iq% moisture content. Pressure preservative treat items in contact with
<br />roofing, flashing, waterproofing, masonry, concrete or the ground.
<br />3. Plywood, APA rated For use and exposure.
<br />a. Backing: Interior A/C grade.
<br />4. Building paper: Asphalt saturated felt, non -perforated, A5TM D 226, Typ I. 30 Ibs
<br />5. Wood treatment:
<br />a. Exterior wood AWPA standard UI and TI. Catagories UCI, U62, U05A,
<br />U655, CU4A, CU4B Alkaline Copper Quaternary based treatment.
<br />b. Interior wood AWPA GI Timber, AWPA Cq Plywood, AWPA C31 Lumber not
<br />in contact with ground and protected From water, AWPA 5 Waterborne
<br />Preservatives, AWPA M4 Disodium Octoborote based treatment.
<br />6. 5ealonts: For settings wood bucks and nailers in exterior openings.
<br />1. Fire Retardant Treated Wood: All wood blocking within the insulated buildin?
<br />envelope sholl be Fire retardant treated to comply with AWPA 020 (lumber) and
<br />AWPA C21 (plywood) For treatment type.
<br />a. Provide UL label on each treated. Redry treated lumber.
<br />SECTION 06200 FIN15H CARPENTRY
<br />Description of Work:
<br />Wood trim, choir rail, crown molding and door casings as indicated on drawings
<br />Quality Assurance
<br />A. Factory -mark each piece of lumber and plywood with type, grade, mill and grading
<br />agency identification.
<br />B. Comply with applicable standards of AWI Architectural Woodwork Institute
<br />secion 0500
<br />I. Grade Premium
<br />Materials
<br />A. Nominal sizes are indicated except as shown by detail dimensions.
<br />Provide dressed or worked and dressed lumber, as applicable,
<br />manufactured to actual sizes and patterns as shown.
<br />B. Popular painted finish. Use pieces which are made of solid lumber stock.
<br />C. Fasteners and Anchorages. Provide nails screws adn other anchoring
<br />devices of the type size material and finish required. For application
<br />indicated to providesecure attachment concealed where possible.
<br />Adjustment, Gleaning, Finishing and Protection
<br />A. Repair damaged and defective finish carpentry work wherever possible to eliminate
<br />defects functionally and visually; where not possible to repair properly, replace
<br />woodwork. Adjust joinery for uniform appearance
<br />SECTION 06400 - ARCHITECTURAL WOODWORK
<br />Scope: I. Provide shop fabricated woodwork and casework.
<br />Products:l. Quality standard for fabrication and products: Architectural Woodwork Institute
<br />Quality Standards, Custom grade flush overlay unless otherwise noted.
<br />2. Wood species
<br />a. Provide sealed plywood at sinks and wet areas.
<br />3. Plastic laminate: all exposed and semi -exposed surfaces
<br />AWI 5wction 400 premium grade
<br />a. Horizontal surfaces: GP-50 (0.050" nominal thickness)
<br />b. Vertical surfaces: GP-28 (0.28" nominal thickness)
<br />SECTION 06400 - ARCHITECTURAL WOODWORK (cont)
<br />4. Solid Surface- Provide solid surface counter tops extent as
<br />shown on the drawings
<br />5• Hardware:
<br />Doors:
<br />I pr hinges - Blum Clip 110 degree self closing
<br />I pull Stanley 348515 5" Satin Chrome
<br />Drawers:
<br />I pull- Stanley 346515 5" Satin Chrome
<br />I pr drawer slides Knape and Bogt No 1520 self closing
<br />DIV15ION I - INSULATION
<br />SECTION 01200 - INSULATION
<br />Description of Work:
<br />A. Extent of insulaiton work is shown on drawings and indicated by
<br />provision of this seciton.
<br />B. Appplications of insuloiton specified in this secion include the Following
<br />1. Unfaced fiberglass sound attenuation baits
<br />Acceptable Manufacturers
<br />A. Manufacturers sub*ect to compliance with requirements provide
<br />products of one of hie following
<br />I. Manufacturer of Glass Fiber Insulaiton
<br />GertainTeen Corp.
<br />Knouf Fiber Glass Gmb H
<br />Monvill Corp
<br />Owens-Corning Fiberglas Corp.
<br />Insulating Materials
<br />A. General: Provide insulating materials which comply with
<br />requirements indicated for materials compliance with reference
<br />standards and other characteristics.
<br />I. Preformed units sizes to fit application indicated, selected from
<br />manufacturer's standard thickness, widths and lengths.
<br />2. Sound attenuation baits. Provide unFoced mineral Fiber butt
<br />insulation produced by combining glass Fibers with thermosettingg
<br />resins to comply with A5TM C bb5 For Type I (blankets/baits without
<br />membrane farmg). Coordinate installation of sound attenuation
<br />baits with installation of gypsum board.
<br />3. Where sound -rated drywall construction is indicated seal construction
<br />at perimeters, control and expansion joints, openings and penetrations
<br />with a continuous bead of acoustical sealant including a bead at both
<br />faces of partitions. Comply with ASTM C qlq and manufacturer's
<br />recommendations For location of edge trim and close off sound -flanking
<br />paths around or through construction
<br />B. Fire 5ofing Provide fire sofing for installation in locations as indicated
<br />or required.
<br />I. Manufacturer shall provide certification that insulation complies with
<br />applicable building code requirements for performance of insulation
<br />within Fire protection assembly indicated on drawings IIG Minwool or eq.
<br />DIVISION 8 - DOORS AND WINOOW5
<br />SECTION 05110 - WOOD DOOR d FRAMES
<br />Scope: I. Provide metal Frames
<br />2. Provide solid core wood doors, stain hospital standard (dark)
<br />Products: I. Frames: Welded construction with mitered corners; gage as Follows;
<br />a. Interior frames 16 gage up to 5' wide 14 gage over 5' wide.
<br />2. Finish: Rust -inhibiting primer.
<br />3. Fire rated UL labeled, fire rated assembly where required.
<br />4. Doors: 13/4" thick, flush
<br />a. Interior doors: Solid core Poplar
<br />5. Finish
<br />a. Painted
<br />SECTION 08410 - ALUMINUM ENTRANCES AND STOREFRONTS
<br />Scope: I. Provide aluminum entrances and storefronts.
<br />a. Exterior entrance doors and frames.
<br />Products: I. Doors type:
<br />a. Flush type, 1-3/4" thick, tubular Frame members with welded joints;
<br />weatherstripped with compression and sliding weatherstripping.
<br />b. Stile -and -rail type, nominal 1-5/4" thick, medium stile (3" width)
<br />with mechanically Fastened and reinforced joints; weatherstripped
<br />with compression and sliding weatherstripping.
<br />c. Impact rated with Notice of Acceptance certification.
<br />2. Framing System: Units fabricated from aluminum extrusions,
<br />A5TM B 221, and sheet, ASTM B 2041; with thermal break; IR-500 FLUSH,
<br />Dry and Wet Glazed and or equal.
<br />3. Metal Finish:
<br />a. Color anodized.
<br />b. Kynor-500 type thermosetting Fluorocarbon Finish; PPG Duronor,
<br />custom color.
<br />4. Glazing:
<br />a. Single -glazing: laminated impact glass.
<br />5. Hardware: Center pivots, overhead -concealed closers, stops,
<br />threshold, deadlocks and keyed cylinders; push/pull bars or panic
<br />hardware and pull bar.
<br />6. Exposed Fasteners are prohibited.
<br />SECTION OL3110 - FINISH HARDWARE
<br />Scope: I. Provide finish hardware For swinging doors.
<br />Products: I. Hinges, butts and pivots: Full -mortise, 5 knuckles ball -bearing
<br />type; Stanley.
<br />2. Locksets and lotchsets:
<br />a. Standard duty (light commercial and residential): 5chlage A Series.
<br />b. Heavy duty (commercial and institutional): 5chlage D Series.
<br />c. Heavy duty mortise type (commercial): 5chlage L 41000 Series.
<br />SECTION 08110 - FIN15H HARDWARE (cont.)
<br />3. Lock cylinders and keying: Interchangeable -core pin tumbler lock cylinders
<br />and nickel silver keys.
<br />4. Bolts and coordinotors: Ives.
<br />5. Exit devices: Von Duprin.
<br />b. Closers:
<br />a. Low frequency doors: LGN 4030/4150 series.
<br />b. High Frequency doors (Fire -labelled doors, toilet room doors, tenant entry doors,
<br />stair doors): LGN 4010/4110 series.
<br />DIVISION q - FINISHES
<br />SECTION 001250 - GYP5UM DRYWALL
<br />Scope: I. Gypsum drywall including screw type metal support systems.
<br />2. Drywall Finishing: Smooth joint tape and
<br />compound treatment for paint finish
<br />3. Moisture resistant gypsum board for installation in wet areas
<br />such as toilet rooms, mop rooms, janitors closets, Food service
<br />areas, behind fiberglass showers, and
<br />under the balance of wall the installations.
<br />Do not install in showers.
<br />4.Type C fire code gypsum drywall For rated assemblies
<br />Products: 1. Gypsum rioliboord: ASTM C 56, of types, edge configuration and thickness indicated:
<br />in maximum lengths available to minimize end -to -end butt joints
<br />a. Type: Regular, unless otherwise indicated. Type "X" for rated assemblies
<br />which has been tested adn listed by recognized authorities including ULFN
<br />and Gypsum Association
<br />b. Edges: Tapered
<br />c. Thickness: As indicated, or if not otherwise indicated, as required to comply
<br />with A5TM 6840 For application system and supporting spacing indicated.
<br />2. Wall/Partition Support Materials:
<br />a. Studs: A5TM 0645: 20 gage unless otherwise indicated. Use 16 gage steel studs
<br />at shower seat supports and rolling counter service doors or where required by equipment
<br />b. Use minimum 20 gage studs at high walls and door/borrowed light Jambs.
<br />Consult manufacturers literature limiting height/gages of all wall assemblies
<br />3. Accessories: Galvanized steel corner beads, casing beads, control joints
<br />4. Acoustical sealant: U5 Gypsum Acoustical Sealant
<br />SECTION 041300- TILE
<br />Decription of work:
<br />I. Porcelain wall tile, floor base and trim
<br />Quality Assurance:
<br />I. AN51 Standard for Ceramic Tile: Comply with AN51 A131.1 "American
<br />National Standard Specifications forGeromic Tile". Furnish tile complying
<br />with Standard Grade requirements unless otherwise noted.
<br />2. Installation guidelines: Comply with the recommendatioins of the Tile Council of
<br />America 2006 edition for installation procedures.
<br />3. Propietory Materials: Handle, store, mix and apply proprietary
<br />setting and grouting materials in compliance with manufacturer's instructions.
<br />Samples:
<br />I. Submit samples of each product specified
<br />Extra Materials:
<br />2. Deliver extra materials to owner. Furnish 3% extra materals that match product installed as described
<br />below, package with protective covering For storage adn identifed with lables clearly describing contents.
<br />Tile Products:
<br />I. As specified on sheet Ab.0 and A6.1
<br />Morter and Grout:
<br />I. Latex modified portlond cement dry -set morter; AN51 A118.4
<br />Grout:
<br />I. As Specified on Sheets A6.0 and A6.1
<br />Tile Installation Standards:
<br />I: Comply with ANSI Standards, AN51 A108.5, ANSI A108.6,
<br />2. Manufacturer's requirements
<br />3. Tile Council of America Guidelines
<br />Tile installation:
<br />I. Extend the into recess and under or behind equipment and fixtures
<br />2. Accurately form intersections and returns. Carefully grid cut edges adn fit the
<br />closely to electrical outlets, piping and Fixtures
<br />3. Unless otherwise noted lay tile in grid patter. Align joints when adjoining tiles on floor
<br />base and walls and trim. Adjust to minimize the cutting. Provide uniform joint widths u.o.n.
<br />SECTION 041510 - ACOUSTICAL CEILINGS
<br />Scope: I. Provide acoustical ceilings and metal suspension system.
<br />2. Fire Performance Characteristics: Provide materials that are identical to those tested For
<br />the following Fire performance characteristics, per ASTM test method indicated below,
<br />by UL or other testing and inspecting organizations acceptable to authorities having
<br />jurisdiction. Identify acoustical ceiling components with appropriate markings of
<br />applicable testing and inspecting organizations.
<br />a. Flame spread 25 or less
<br />b. Smoke developed 450 or less
<br />3. Install products per manufacturers recommendations.
<br />Products: I. Acoustical panels: To be match existing 2 x 2 with angled tegular edge
<br />Exent as indicated on drawings
<br />2. Exposed grid suspension system: To match existing.
<br />3. Extra materials
<br />a. Provide additional panels and grid in on amount equal to 2.0 percent of each type
<br />of specified for maintenance stock.
<br />SECTION 001650 - RESILIENT FLOORING
<br />Scope: I. Provide resilient flooring and base as indicated on drawings
<br />2. Install per manufacturers recommendations
<br />3. Fire Test Performance: Provide resilient flooring which complies with the following
<br />fire test performance criteria as determined by an independent testing laboratory
<br />acceptable to authorities having jurisdiction.
<br />a. Critical Radiant Flux (GRF): Not less than the following rating per A5TM E 648.
<br />0.45 watts per sq. cm.
<br />b. Flame Spread: Not more than 25 per A5TM E 84.
<br />c. Smoke Developed: Not more than 450 per A5TM E 84
<br />d. Smoke Density: Not more than 450 per A5TM E662
<br />e. Sheet vinyl extent as indicated on drawings
<br />Products: 1. Accessories
<br />a. Wall base: 4" vinyl cove as indicated on plans
<br />2. Adhesives (Cements): Waterproof, stabilized type as recommended by Flooring
<br />manufacturer to suit material and substrate conditions.
<br />3. Concrete slab primer: Non -staining type compatible with adhesive as recommended by
<br />Flooring manufacturer.
<br />5. Leveling compound: Latex type compatible with adhesive as recommended by
<br />Flooring manufacturer.
<br />6. Extra materials.
<br />a. Provide additional resilient Flooring in the amount of 2.0 percent For each type
<br />specified for maintenance stock.
<br />Guarantees and Warrantees
<br />I. Upon completion the resilent flooring contractor must submit a certificate
<br />guaranteeing the installation to be Freee of defects in workmanship For a
<br />period of I year to include the statement. that the resilent flooring contractor
<br />shall at his own expense and upon written notice from the Architect promply
<br />correct/replace any and all improper work and material that may become
<br />apparent within 12 months after the date of final completion.
<br />Maintenance Stock
<br />A. Supply loose stock equal to 10% of each potern and type specified
<br />Products
<br />installoiton
<br />A. As indicated on plans
<br />A. Existing or previously treated substrate with respect to wax, soap or other residual
<br />build-up must be removed prior to installation.
<br />SECTION 0414100 PAINTING
<br />Scope: 1. Provide painting and surface preparation for all interior and exterior
<br />wFaces, as required
<br />2. Prepare surface and apply per manufacturers recommendation.
<br />Products: 1. Premium products For all systems
<br />2. Interior Paint Schedule: New Surfaces:
<br />a. Zinc -coated Metal
<br />I. Semi -Gloss Alkyd Enamel. 2 finish coats over primer
<br />b. Primed Metal
<br />I. 5emi-G1oss Alkyd Enamel: Two coats over existing primer
<br />c. Gypsum Board Level 5 finish
<br />I. Satin Latex Finishes: Two coats over primer
<br />d. Existing Zinc Coated or Primed Metal:
<br />I. Semi Gloss Alkyd Enamel: (2) coats over prepared surface.
<br />SECTION 10440- SPECIALTY SIGNS
<br />1. Provide specialty building signoge
<br />2. Provide signage in compionce with ADA requirements
<br />SECTION 10522-FIRE EXTEING1,1I5HER5, CABINETS AND ACCESSORIES
<br />Scope: I. Provide portable Fire extinguisher cabinets. Provide mounting brackets where no cabinet is indicated
<br />Products: 1. Fire Extinguishers. UL listed and labeled units J.L Industries
<br />a. Multi -purpose dry chemical type.
<br />2. Cabinets: Enamelled steel box with trim, frame, door and accessories; J.L. Industries
<br />a. Mounting Semi -recessed
<br />b. Trim- Trimless
<br />c. Door and trim material- Enamelled steel, baked enamel finish
<br />d. Door Style- Duo -panel, berticol vinyl die cut letters
<br />SECTION 10600- TOILET AND BATH ACCESSORIES
<br />Scope: I. Provide toilet accessories at toilet rooms
<br />Products: I. Units: Stainless steel Fabrication with A151 No.4 bright directional polish finish;
<br />Bobrick Washroom Equipment, Inc.
<br />2. Mounting- Semi recessed and surFoce mounted
<br />3. Types and quantities:
<br />a. Waste dispenser
<br />b. Toilet tissue disperser
<br />c. Soap dispenser
<br />d. Grab bars; I set per toilet room
<br />e. Janitor's utility unit; 2 per closet
<br />f. 5hower curtain rod; I per stall
<br />g. Shower Curtain and hooks; I per shower stall, mildew resistant
<br />h. Hinged shower seat
<br />1. Towel bars
<br />j. Mirror units, Stainless steel Framed