Laserfiche WebLink
N <br />N <br />N, <br />_ o <br />lq- <br />N <br />cc <br />N <br />EF <br />WIRING DEVICES: <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) <br />IN WALL +18" OR AS NOTED. <br />IG = (NEMA 20-R) WITH ISOLATED GROUND <br />TL = TWIST LOCK TYPE <br />S = SECURITY TYPE COVER AND SCREWS <br />EQUAL TO FAILSAFE #SSB1-1 D <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) - IN WALL 6" ABOVE <br />COUNTER TOP OR BACK SPLASH. <br />e SIMPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />IN WALL +18" OR AS NOTED. <br />DOUBLE DUPLEX RECEPTACLE ( QUAD) ON EMERGENCY, CRITICAL <br />OR LIFE SAFETY CIRCUIT AS INDICATED BY HOME RUN. <br />DUPLEX RECEPTACLE - 20A, 125V, 3W (NEMA 5.20R) - <br />IN WALL 8" ABOVE COUNTER TOP <br />ON EMERGENCY, CRITICAL OR LIFE SAFETY CIRCUIT <br />AS INDICATED BY HOME RUN <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) <br />IN WALL +18" OR AS NOTED. ON EMERGENCY, CRITICAL <br />OR LIFE SAFETY CIRCUIT AS INDICATED BY HOME RUN <br />IG = (NEMA 20-R) WITH ISOLATED GROUND <br />TL = TWIST LOCK TYPE <br />S = SECURITY TYPE COVER AND SCREWS <br />EQUAL TO FAILSAFE #SSB1-1D <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) - IN WALL +18" OR AS NOTED - <br />ONE RECEPTACLE HOT, ONE RECEPTACLE <br />SWITCHED. <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R). <br />FLUSH MOUNTED IN FLOOR WITH SERVICE FITTINGS. <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R). <br />FLUSH MOUNTED IN FLOOR WITH SERVICE FITTINGS. <br />ON EMERGENCY, CRITICAL OR LIFE SAFETY CIRCUIT <br />AS INDICATED BY HOME RUN. <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R), FLUSH MOUNTED IN CEILING. <br />O FLOOR OUTLET BOX WITH SIMPLEX <br />RECEPTACLE - 20A, 125V, 2P, 3W, <br />(NEMA 5-20R). <br />OUTLET BOX IN COUNTER TOP WITH <br />SERVICE FITTINGS AND DUPLEX RECEPTACLE <br />20A, 125V, 2P, 3W (NEMA 5-20R). <br />TRIPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) - IN WALL +18" OR AS NOTED. <br />TRIPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) - IN CEILING. <br />TRIPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) - IN WALL 8" ABOVE <br />COUNTER TOP OR BACKSPLASH. <br />GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, <br />20A, 125V, 2P, 3W IN WALL +18" OR AS NOTED. <br />GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, <br />20A, 125V, 2P, 3W IN WALL +6" ABOVE COUNTER TOP <br />OR BACK SPLASH. UNLESS OTHERWISE NOTED. <br />QUADPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) <br />IN WALL +18" OR AS NOTED. <br />IG = (NEMA 20-R) WITH ISOLATED GROUND <br />TL = TWIST LOCK TYPE <br />S = SECURITY TYPE COVER AND SCREWS <br />EQUAL TO FAILSAFE #SSB1-1D <br />QUADPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) <br />IN WALL +6" ABOVE COUNTER TOP OR BACK SPLASH. <br />IG = (NEMA 20-R) WITH ISOLATED GROUND <br />TL = TWIST LOCK TYPE <br />S = SECURITY TYPE COVER AND SCREWS <br />EQUAL TO FAILSAFE #SSB1-1 D <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) WITH SWITCH, IN TWO <br />GANG BOX - IN WALL +18" OR AS NOTED. <br />LLe_ SIMPLEX RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) WITH FUSE HOLDER AND <br />FUSESTAT - IN WALL OR AS NOTED. <br />DUPLEX COMBINATION RECEPTACLE <br />20A, 125V, 2P, 3W (NEMA 5-20) AND <br />20A, 250V,1 PH, 2P, 3W (6-20R) <br />IN WALL +18" OR AS NOTED. <br />e- SIMPLEX POWER RECEPTACLE 250V,1 PH, 2P, 3W <br />20A, 30A OR 50A AT OUTLET INDICATES AMPERE <br />RATING (NEMA 6-20R, 6-30R OR 6-50R) <br />IN WALL +18" OR AS NOTED. <br />DUPLEX POWER RECEPTACLE - 20A, 250V,1 PH, 2P, <br />3W (NEMA 6-20R) - IN WALL +18" OR AS NOTED. <br />DUPLEX POWER RECEPTACLE - 20A, 277V, 2P, 3W <br />(NEMA 7-20R) - IN WALL OR AS NOTED. <br />SIMPLEX POWER RECEPTACLE - DUAL VOLTAGE <br />125/250V,1 PH, 3P, 4W <br />20A, 30A, 50A OR 60A <br />AT OUTLET INDICATES AMPERE RATING <br />(NEMA 14-20R, 14-30R, 14-50R OR 14-60R) <br />IN WALL +18" OR AS NOTED <br />COMBINATION FLOOR BOX, DOUBLE DUPLEX <br />P RECEPTACLE - 20A 125V 2P. 3W. <br />����� TO BE POURED IN PLACE. <br />COMBINATION FLOOR BOX, DOUBLE DUPLEX <br />R RECEPTACLE - 20A 125V 2P. 3W. <br />TO BE USED IN RAISED FLOOR TILES. <br />SIMPLEX POWER RECEPTACLE - 250V, 3PH, 3P, 4W-20A, <br />30A, 50A OR 60A AT OUTLET INDICATES <br />AMPERE RATING (NEMA 15-20R,15-30R, <br />15-50R OR 15-60R) - IN WALL +18" OR AS NOTED. <br />ELECTRICAL SYMBOLS <br />NOTE: NOT ALL SYMBOLS SHOWN MAYBE REQUIRED FOR THIS PROJECT. <br />WIRING DEVICES: LIGHTING FIXTURES: EQUIPMENT: NOTES: <br />1711710 RAISED FLOOR DISTRIBUTION BOX <br />LOCATED ON SLAB BELOW RAISED <br />Li Li Li FLOOR TILES. WIREMOLD # SDU-PD-X <br />SIMPLEX POWER RECEPTACLE - DUAL VOLTAGE - <br />120V/208V, 3PH Y, 4P, 4W-20A, 30A, 50A OR 60A <br />AT OUTLET INDICATES AMPERE RATING (NEMA <br />18-20R, 18-30R, 18-50R OR 18-60R) - IN WALL <br />+18" OR AS NOTED. <br />CLOCK HANGER RECEPTACLE - 20A, 125V, 2P, 3W <br />(NEMA 5-20R) - IN WALL +84" OR AS NOTED. <br />OPERATING ROOM X-RAY OUTLET IN WALL <br />60" ABOVE FLOOR TO BOTTOM OR AS NOTED. <br />�- OUTLET WITH SPECIAL DEVICE AS NOTED - +18" AFF OR AS NOTE[ <br />® OUTLET WITH SPECIAL DEVICE AS NOTED - IN FLOOR. <br />OUTLET WITH SPECIAL DEVICE AS NOTED - IN CEILING. <br />Q-� JUNCTION OR OUTLET BOX IN WALL. +18" OR AS NOTED. <br />JO JUNCTION OR OUTLET BOX IN FLOOR. <br />JUNCTION OR OUTLET BOX IN CEILING. <br />0­9 FREE STANDING OUTLET BOX - ON CONDUIT <br />STUB WITH TYPE DEVICE AS INDICATED +4" <br />ABOVE FLOOR OR AS NOTED. <br />THERMOSTAT IN WALL OR AS NOTED. <br />SINGLE POLE WALL SWITCH. LOWER CASE LETTERS <br />INDICATE FIXTURES ASSOCIATED WITH SWITCH. <br />2 = 2 POLE <br />3= 3WAY <br />4=4WAY <br />P/L = SWITCH WITH PILOT LIGHT <br />LIT = LOCKING TYPE SWITCH <br />K = KEY TYPE SWITCH <br />S = SECURITY TYPE COVER WITH KEY SWITCH <br />MOUNT AT +48" UNLESS NOTED OTHERWISE. <br />B TWO SWITCHES FOR BI-LEVEL SWITCHING <br />MOTION DETECTOR IN CEILING <br />MOTION DETECTOR IN WALL <br />PUSH BUTTON - S.S. INDICATES START, I <br />STOP OR AS INDICATED. <br />,- LOCAL LIGHT DIMMER. MOUNT AT +48" UNLESS <br />OTHERWISE NOTED. 3 INDICATES 3 WAY <br />4 INDICATES 4 WAY. <br />RAISE/LOWER CONTROL FOR REMOTE <br />LIGHT DIMMER. <br />2 MOTOR SPEED CONTROLLER <br />2 SPEED, 3 SPEED OR V - VARIABLE <br />SPEED AS INDICATED. <br />LIGHTING FIXTURES: <br />�O 2x4 <br />® lx4 FLUORESCENT FIXTURE AS SPECIFIED <br />---a-d STRIP CONNECTED TO NORMAL POWER. <br />D 2x2 <br />® 2x4 <br />® 1x4 FLUORESCENT FIXTURE AS SPECIFIED <br />F-0--i STRIP CONNECTED TO LIFE SAFETY OR <br />LEGALLY REQUIRER POWER. <br />® 2x2 <br />2x4 <br />® lx4 FLUORESCENT FIXTURE AS SPECIFIED <br />I--o-� STRIP CONNECTED TO EMERGENCY OR <br />CRITICAL POWER. <br />2x2 <br />® 2x4 <br />® 1x4 FLUORESCENT FIXTURE AS SPECIFIED <br />I--®--{ STRIP CONNECTED TO EMERGENCY OR CRITICAL <br />POWER WITH INSTANTANEOUS BATTERY <br />® 2x2 <br />® DOWN LIGHT AS SPECIFIED. <br />CONNECTED TO NORMAL POWER. <br />® DOWN LIGHT AS SPECIFIED. CONNECTED TO <br />LIFE SAFETY OR LEGALLY REQUIRER POWER. <br />® DOWN LIGHT AS SPECIFIED. CONNECTED TO <br />EMERGENCY OR CRITICAL POWER. <br />WALL MOUNTED FIXTURE AS SPECIFIED MOUNTED <br />o- +84" ABOVE FLOOR OR AS NOTED. <br />CONNECTED TO NORMAL POWER <br />WALL MOUNTED FIXTURE AS SPECIFIED MOUNTED <br />+84" ABOVE FLOOR OR AS NOTED. CONNECTED TO <br />LIFE SAFETY OR LEGALLY REQUIRER POWER. <br />WALL MOUNTED FIXTURE AS SPECIFIED MOUNTED <br />+84" ABOVE FLOOR OR AS NOTED. <br />CONNECTED TO EMERGENCY OR CRITICAL POWER. <br />® EXIT LIGHT, CEILING MOUNTED, ARROW DIRECTION <br />AS INDICATED ON PLAN. CONNECTED TO LIFE SAFETY <br />OR LEGALLY REQUIRER POWER. <br />EXIT LIGHT, WALL MOUNTED +84" ABOVE FLOOR <br />OR AS NOTED. ARROW DIRECTION AS INDICATED <br />ON PLAN. CONNECTED TO LIFE SAFETY OR <br />LEGALLY REQUIRER POWER. <br />WALL MOUNTED BATTERY OPERATED <br />EMERGENCY LIGHT FIXTURE. +90" UNLESS <br />OTHERWISE NOTED. <br />CEILING MOUNTED BATTERY OPERATED <br />EMERGENCY LIGHT FIXTURE. <br />o- <br />WALL MOUNTED SPECIAL LETTERING SIGN AS SPECIFIED. <br />MOUNT AT +84" UNLESS OTHERWISE NOTED. <br />REMOTE LIGHT FIXTURE FOR BATTERY <br />OPERATED EMERGENCY LIGHTING <br />0p <br />HIGH INTENSITY DISCHARGE FIXTURE AS SPECIFIED <br />FS <br />®CHANDELIER <br />TYPE FIXTURE AS SPECIFIED <br />SUSPEND FROM CEILING AS NOTED. <br />MISCELLANEOUS SYMBOLS: <br />©� <br />PROJECTOR OUTLET -IN WALL <br />O� <br />PROJECTOR OUTLET -IN FLOOR BOX <br />�- <br />REMOTE GROUND INDICATOR FOR ISOLATION <br />DISTRIBUTION PANEL, 72" ABOVE FLOOR. <br />PO-+ <br />PHOTOCELL <br />T S <br />TIME SWITCH <br />Q <br />REFERENCED NOTE <br />JAMPI <br />AMPLIFIER <br />T-30 <br />- D S - <br />DOOR STRIKE SWITCH. <br />D. F . <br />DRINKING FOUNTAIN <br />E W C . <br />ELECTRIC WATER COOLER <br />MCB. <br />MAIN CIRCUIT BREAKER <br />PM <br />RECEPTACLE POWER MODULE <br />4 <br />6 DUPLEX RECEPTACLES <br />E <br />PUSHBUTTON <br />E V <br />CARD READER <br />;ONDUIT, RACEWAYS AND LIGHTING: <br />EXPOSED CONDUIT OR SURFACE <br />RACEWAY'R' INDICATES RACEWAY <br />CONDUIT CONCEALED IN WALL OR <br />CEILING CONSTRUCTION <br />- - - - , <br />CONDUIT CONCEALED IN FLOOR <br />, <br />CONSTRUCTION OR UNDERGROUND <br />�MT--,, <br />SPECIAL SYSTEM WIRING TO CENTRAL EQUIPMENT, <br />PANEL, CABLE TRAY, TERMINAL CABINET OR <br />NEXT DEVICE. <br />TD = TELEPHONE AND DATA <br />MT = EMPTY <br />CP = MASTER CLOCK & PROGRAM SYSTEM <br />MC = MASTER CLOCK SYSTEM <br />IC =INTERCOM SYSTEM <br />TV = TELEVISION SYSTEM <br />TVC = TELEVISION REMOTE CONTROL <br />NC = NURSE CALL SYSTEM <br />P = PAGING SYSTEM <br />T = TELEPHONE SYSTEM <br />GF = CIRCUIT TO GROUND FAULT <br />CIRCUIT BREAKER <br />EIL = EQUIPMENT INTERLOCK <br />MP = MUSIC/PAGING SYSTEM <br />CPP = CENTRAL PAGE/PROGRAM SYSTEM <br />STV = SECURITY TELEVISION SYSTEM <br />M = MUSIC SYSTEM <br />- - - - ' <br />DIRECT BURIAL CABLE <br />HOME RUN TO PANELBOARD-NUMBER OF <br />ARROWS INDICATES NUMBER OF CIRCUITS <br />EXPLOSION PROOF CONDUIT WITH <br />CONDUIT SEALS. <br />LAY IN WIREWAY DUCT, SIZE AS NOTED. <br />CABLE TRAY, SIZE AS NOTED. <br />FEEDER DUCT -RATING AND NUMBER <br />OF CONDUCTORS AS NOTED. <br />PLUG IN DUCT -RATING AND NUMBER <br />OF CONDUCTORS AS NOTED. <br />PLUG IN STRIP TYPE RECEPTACLES OR <br />OTHER OUTLETS AS NOTED. <br />- - - E- - - <br />UNDER FLOOR DUCT -ELECTRICAL <br />- - - - T - - - <br />UNDERFLOOR DUCT - TELEPHONE OR <br />OTHER LOW TENSION AS NOTED. <br />CONDUIT UP <br />CONDUIT DOWN <br />PULL BOX <br />GROUND <br />000a <br />BUS DUCT <br />POWER/COMMUNICATIONS LINEAR RACEWAY <br />-------- <br />MAPNET CIRCUIT <br />FLOOR DUCT <br />I0 <br />MOTOR OUTLET AND CONNECTION. <br />EQUIPMENT TYPE AS NOTED. <br />EQUIPMENT TERMINAL POINT VERIFY <br />REQUIREMENTS AND LOCATION WITH <br />EQUIPMENT MANUFACTURER. <br />EQUIPMENT TERMINAL POINT IN WALL <br />+18" ABOVE FLOOR VERIFY REQUIREMENTS <br />WITH EQUIPMENT MANUFACTURER. <br />SAFETY DISCONNECT SWITCH -FUSED <br />UNLESS NOTED N.F. (NON -FUSED). <br />FUSE HOLDER WITH FUSESTAT AND <br />TOGGLE SWITCH. <br />MOTOR STARTER -MAGNETIC UNLESS <br />NOTED MAN. (MANUAL). <br />ELECTRICAL ALTERNATOR <br />BRANCH CIRCUIT PANELBOARD <br />SURFACE MOUNTED. <br />BRANCH CIRCUIT PANELBOARD <br />FLUSH MOUNTED. <br />POWER DISTRIBUTION PANELBOARD OR <br />OTHER ELECTRICAL EQUIPMENT -SURFACE <br />MOUNTED OR FREE STANDING <br />POWER DISTRIBUTION PANELBOARD <br />FLUSH MOUNTED. <br />DRY TYPE TRANSFORMER. NUMBER <br />INDICATES KVA SIZE. <br />RELAY. RATING AS NOTED. <br />SPECIAL CABINET OR EQUIPMENT <br />AS NOTED. FLUSH MOUNTED. <br />CONTACTOR RATINGS AS SCHEDULED. <br />DEVICE BRANCH CIRCUIT CONNECTION <br />TO ELECTRIC FLUSH VALVE. <br />COORDINATE WITH DIV.15. <br />OPERATING ROOM POWER GROUND PANEL <br />WITH FOUR (4) GROUND JACKS, FOUR <br />(4) DUPLEX HOSPITAL GRADE RECEPTACLES <br />RECEPTACLES AND EQUALIZER GROUND <br />TERMINAL BUS. ( SEE DETAIL) <br />MASTER REFERENCE GROUND POINT. <br />SPECIAL CABINET OR EQUIPMENT AS NOTED <br />SURFACE MOUNTED <br />UTILITY METER AND TRIM <br />GENERAL NOTES: <br />1. REFER TO PROJECT MANUAL AND/OR PROJECT <br />DRAWINGS FOR MOUNTING HEIGHTS. <br />2. UPPER CASE LETTERS'DD' AT DUPLEX RECEPTACLE <br />INDICATES DOUBLE DUPLEX RECEPTACLE IN TWO <br />GANG BOX. <br />3. LETTERS 'WP' AT DEVICE OR EQUIPMENT INDICATES <br />NEMA 3R TYPE. <br />4. LETTERS'EX' AT DEVICE INDICATES EXISTING. <br />5. LETTERS "XP' AT DEVICE OR EQUIPMENT INDICATES <br />EXPLOSIONPROOF TYPE. <br />6. LETTERS 'TL' AT RECEPTACLE INDICATES <br />TWIST - LOCK TYPE. <br />S - INDICATES SECURITY TYPE, BY FAILSAFE <br />CAT. #SSB1-1 D <br />7. LOWER CASE LETTERS AT SWITCHES AND FIXTURES <br />INDICATES ASSOCIATED UNITS FOR SWITCHING. <br />8. UPPER CASE LETTERS AT FIXTURE INDICATES <br />FIXTURE TYPE. <br />9. NUMBER AT FIXTURE OR OUTLET INDICATES <br />PANEL CIRCUIT NUMBER. <br />10. PLUS (+) SIGN WITH DIMENSION AT OUTLET <br />INDICATES HEIGHT ABOVE FINISHED <br />FLOOR LINE OR HEIGHT ABOVE FINISHED <br />GRADE TO CENTER. <br />1. PREFORM WORK IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL <br />APPLICABLE BUILDING CODES AS INTERPRETED BY THE LOCAL AUTHORITY HAVING <br />JURISDICTION. <br />2. THE EXISTING CONDITIONS ARE SHOWN AS ACCURATELY AS FIELD CONDITIONS <br />WOULD PERMIT. BIDDERS SHALL THOROUGHLY EXAMINE THE CONTRACT DOCUMENTS, <br />VISIT THE SITE & VERIFY ALL EXISTING CONDITIONS. THE CONTRACTOR SHALL <br />REPORT TO THE ARCHITECT/ENGINEERING FIRM, BEFORE SUBMITTING A BID, ANY <br />CONDITIONS WHICH MIGHT MAKE INSTALLATION OF REQUIRED EQUIPMENT A PROBLEM. <br />NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE TO INVESTIGATE <br />CONDITIONS OR MISUNDERSTANDINGS OF THE CONTRACTURAL REQUIREMENTS. <br />3. IT IS THE INTENT OF THESE DRAWINGS TO CALL FOR FINISHED WORK, TESTED <br />& READY FOR OPERATION. THE WORD "PROVIDE" MEANS "FURNISHED & INSTALL <br />COMPLETE & READY FOR USE". <br />4. SEAL ALL FLOOR & FIRE -RATED WALL PENETRATIONS WITH UL APPROVED <br />FIREPROOFING MATERIALS. <br />5. PROVIDE MINIMUM #12 AWG WIRE SIZE AND Y4" CONDUIT FOR ALL BRANCH CIRCUITRY. <br />UNLESS OTHERWISE NOTED. <br />6. MOUNTING HEIGHTS GIVEN ON ELECTRICAL DRAWINGS ARE FOR BIDDING PURPOSES <br />ONLY. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR MOUNTING HEIGHTS <br />OF ALL WIRING DEVICES & EQUIPMENT JUNCTION BOXES. WHERE DISCREPANCIES <br />OCCUR BETWEEN ELECTRICAL & ARCHITECTURAL DOCRMENTS, THE ARCHITECTURAL <br />ELEVATIONS TAKE PRECEDENCE. <br />7. FOR ACTUAL LOCATION OF CEILING MOUNTED LIGHTING FIXTURES, SEE <br />ARCHITECTURAL REFLECTED CEILING PLANS. <br />8. MECHANICAL DRAWINGS TAKE PRECEDENCE OVER DESCRIPTIONS OF MOTORS & <br />OTHER MECHANICAL EQUIPMENT. SEE MECHANICAL DRAWINGS FOR ACTUAL <br />LOCATION OF MECHANICAL EQUIPMENT. <br />9. CAREFULLY COORDINATE ALL ROUGH -IN REQUIREMENTS FOR OWNER FURNISHED <br />EQUIPMENT WITH OWNER & EQUIPMENT SUPPLIERS. <br />10. PROVIDE A GREEN INSULATED GROUNDING CONDUCTOR FOR ALL BRANCH CIRCUITS. <br />GROUND CONDUCTORS ARE NOT SHOWN IN WIRING DESIGNATION. <br />11. COORDINATE EQUIPMENT ITEMS NEXT TO DEVICES AND EQUIPMENT <br />CONNECTIONS WITH EQUIPMENT PLANS OF THE CONTRACT DOCUMENTS FOR <br />ACTUAL LOCATIONS AND EQUIPMENT DESCRIPTIONS. <br />12. ALL LIFE SAFETY OR LEGALLY REQUIRED LIGHTING CIRCUITS SHALL BE FED WITH #10 AWG. <br />13. COORDINATE THE LOCATION OF ALL IN -FLOOR POWER & COMBINATION BOXES <br />THAT ARE POURED IN -PLACE OR USED IN RAISED FLOORS WITH FURNITURE <br />LAYOUTS & ARCHITECTURAL DETAILING OF COURTROOMS. <br />Project No. 12036.00 <br />EOO I <br />$DATE$ $TIME$ $FILEA$ <br />© 2012 BHIPK Architects, Inc. <br />