My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (129)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (129)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:36:20 PM
Creation date
2/25/2025 9:48:41 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Rodda Construction
Building Plans - Permit #
12953
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
oMA 0 �_AAdol <br />N <br />N <br />0 <br />NI <br />R <br />C\- <br />N <br />19 <br />3-4"C <br />2"C <br />1 1 /2"C <br />2 1 /2" C <br />SCOPE OF WORK <br />^'JLL B0;< <br />30VE CEILING <br />--------- <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I 1 <br />� 1 <br />`---------------------- <br />PULL BOX <br />ABOVE CEILING <br />DEMOLITION PLAN - OVERHEAD CONDUIT <br />SCALE: %" = 1' - 0" <br />DEMO NOTES: <br />1. REMOVE ALL OVERHEAD CONDUIT & PULL BOXES FROM THIS PLAN. <br />CONTRACTOR TO SAVAGE CONDUIT & BOXES FOR THIS 'DROJECT <br />OR THERE USE. <br />ELECTRICAL SYMBOLS <br />WIRING DEVICES: <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) <br />IN WALL +18" OR AS NOTED. <br />IG = (NEMA 20-R) WITH ISOLATED GROUND <br />TL = TWIST LOCK TYPE <br />S = SECURITY TYPE COVER AND SCREWS <br />EQUAL TO FAILSAFE #SSB1-1D <br />QUADPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) <br />IN WALL +18" OR AS NOTED. <br />IG = (NEMA 20-R) WITH ISOLATED GROUND <br />TL = TWIST LOCK TYPE <br />S = SECURITY TYPE COVER AND SCREWS <br />EQUAL TO FAILSAFE #SSB1-1 D <br />DOUBLE DUPLEX RECEPTACLE ( QUAD) ON EMERGENCY, CRITICAL <br />OR LIFE SAFETY CIRCUIT AS INDICATED BY HOME RUN. <br />LIGHTING FIXTURES: <br />2x4 <br />® 1x4 FLUORESCENT FIXTURE AS SPECIFIED <br />I--o-� STRIP CONNECTED TO NORMAL POWER. <br />❑O 2x2 <br />® 1x4 FLUORESCENT FIXTURE AS SPECIFIED <br />I--o-� STRIP CONNECTED TO EMERGENCY OR <br />CRITICAL POWER. <br />2x2 <br />® DOWN LIGHT AS SPECIFIED. CONNECTED TO <br />EMERGENCY OR CRITICAL POWER. <br />CONDUIT, RACEWAYS AND LIGHTING: <br />CONDUIT CONCEALED IN WALL OR <br />CEILING CONSTRUCTION <br />COMMUNICATIONS SYSTEMS: <br />INFORMATION MANAGEMENT (IMO) WALL MOUNTED <br />+18" ABOVE FLOOR OR AS NOTED. <br />NURSE CALL SYSTEMS: <br />NURSE CALL DOME LIGHT - NUMERAL <br />INDICATES TYPE -'Z' AFTER NUMERAL <br />INDICATES ZONE DOME LIGHT. <br />DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W (NEMA 5-20R) � CODE BLUE CALL STATION - <br />IN WALL +18" OR AS NOTED. ON EMERGENCY, CRITICAL 'PB' INDICATES PUSH BUTTON <br />OR LIFE SAFETY CIRCUIT AS INDICATED BY HOME RUN ® EXIT LIGHT, CEI�_ING MOUNTED, ARROW DIRECTION 'FS' INDICATES FOOT SWITCH <br />O <br />IG = (NEMA 20-R) WITH ISOLATED GROUND AS INDICATED PLAN. CONNECTED TO LIFE SAFETY +42" ABOVE OF FLOOR OR AS NOTE. <br />TL = TWIST LOCK TYPE OR LEGALLY REQUIRER POWER. <br />S = SECURITY TYPE COVER AND SCREWS FIRE ALARM SYSTEMS: <br />EQUAL TO FAILSAFE #SSB1-1D <br />SINGLE POLE WALL SWITCH. LOWER CASE LETTERS meCHIME WITH LIGHT AS ONE ASSEMBLY - <br />INDICATE FIXTURES ASSOCIATED WITH SWITCH. WALL MOUNTED @ + 80 ABOVE FLOOR <br />MOUNT AT +48" UNLESS NOTED OTHERWISE. <br />REUSE EXIST. CUT IN DOUBLE DUPLEX BOX <br />DOUBLE TO REPLACE SINGLE BOX <br />DUPLEX BOX <br />4 2 <br />6 1 <br />11 C1-4 11 r11 11 <br />1LN1-2 1LC <br />I <br />1 1LC1-1 <br />I <br />2 +18„ <br />2 1LC1-2 <br />SCOPE OF WORK 1LC1-8 1LC1-7 <br />1 8 1 LC 1-9 <br />1 1LC1-5 1LN <br />5� - � 3 <br />1 8 3 5 1LN1-3 <br />� 1 <br />`----------------------- <br />POWER PLAN <br />SCALE: %" = 1' - 0" <br />GENERAL NOTES: <br />1. PREFORM WORK IN CONFORMANCE WITH THE NATIONAL ELECTRIC CODE AND ALL <br />APPLICABLE BUILDING CODES AS INTERPRETED BY THE LOCAL AUTHORITY HAVING <br />JURISDICTION. <br />2. THE EXISTING CONDITIONS ARE SHOWN AS ACCURATELY AS FIELD CONDITIONS <br />WOULD PERMIT. BIDDERS SHALL THOROUGHLY EXAMINE THE CONTRACT DOCUMENTS, <br />VISIT THE SITE & VERIFY ALL EXISTING CONDITIONS. THE CONTRACTOR SHALL <br />REPORT TO THE ARCHITECT/ENGINEERING FIRM, BEFORE SUBMITTING A BID, ANY <br />CONDITIONS WHICH MIGHT MAKE INSTALLATION OF REQUIRED EQUIPMENT A PROBLEM. <br />NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE TO INVESTIGATE <br />CONDITIONS OR MISUNDERSTANDINGS OF THE CONTRACTURAL REQUIREMENTS. <br />3. IT IS THE INTENT OF THESE DRAWINGS TO CALL FOR FINISHED WORK, TESTED <br />& READY FOR OPERATION. THE WORD "PROVIDE" MEANS "FURNISHED & INSTALL <br />COMPLETE & READY FOR USE". <br />4. SEAL ALL FLOOR & FIRE -RATED WALL PENETRATIONS WITH UL APPROVED <br />FIREPROOFING MATERIALS. <br />5. PROVIDE MINIMUM #12 AWG WIRE SIZE AND %" CONDUIT FOR ALL BRANCH CIRCUITRY. <br />UNLESS OTHERWISE NOTED. <br />6. MOUNTING HEIGHTS GIVEN ON ELECTRICAL DRAWINGS ARE FOR BIDDING PURPOSES <br />ONLY. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR MOUNTING HEIGHTS <br />OF ALL WIRING DEVICES & EQUIPMENT JUNCTION BOXES. WHERE DISCREPANCIES <br />OCCUR BETWEEN ELECTRICAL & ARCHITECTURAL DOCRMENTS, THE ARCHITEC--URAL <br />ELEVATIONS TAKE PRECEDENCE. <br />7. FOR ACTUAL LOCATION OF CEILING MOUNTED LIGHTING FIXTURES, SEE <br />ARCHITECTURAL REFLECTED CEILING PLANS. <br />8. CAREFULLY COORDINATE ALL ROUGH -IN REQUIREMENTS FOR OWNER FURNISHED <br />EQUIPMENT WITH OWNER & EQUIPMENT SUPPLIERS. <br />9. PROVIDE A GREEN INSULATED GROUNDING CONDUCTOR FOR ALL BRANCH CIRCUITS. <br />GROUND CONDUCTORS ARE NOT SHOWN IN WIRING DESIGNATION. <br />10. EACH TELEPHONE OUTLET SHALL HAVE ONE DOUBLE GANG BOX WITH SINGLE GANG <br />PLASTER RING AND ONE 3/4" CONDUIT TO NEAREST CORRIDOR CABLE TRAY SYSTEM. <br />SELECTED OUTLETS MUST BE LOCATED ABOVE OR IN CASEWORK RESPECTIVELY. <br />CHECK ARCHITECTURAL ELEVATIONS, CASEWORK AND EQUIPMENT DRAWINGS. <br />11. EACH INFORMATION MANAGEMENT OUTLET (IMO) SHALL HAVE ONE DOUBLE GANG <br />BOX WITH SINGLE GANG PLASTER RING & ONE, 1" CONDUIT TO NEAREST CORRIDOR <br />CABLE TRAY SYSTEM. SELECTED OUTLETS MUST BE LOCATED ABOVE OR IN <br />CASEWORK RESPECTIVELY. CHECK ARCHITECTURAL ELEVATIONS, CASEWORK & <br />EQUIPMENT DRAWINGS. <br />PANEL 1 LN 1 (NORMAL) <br />PANEL 1LC1 (CRITICAL) <br />DUPLEX <br />TO CRITICAL <br />Project No. 12010.00 <br />ELI <br />$DATE$ $TIME$ $FILER$ <br />©2012 HH/PK Architects, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.