My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (129)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (129)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:36:20 PM
Creation date
2/25/2025 9:48:41 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Rodda Construction
Building Plans - Permit #
12953
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9 <br />i <br />la <br />N <br />0 <br />O <br />Ez <br />` <br />a N <br />O <br />15 <br />------>>(Z) <br />(W) <br />II.._------------------------- <br />Illll POWER VAULT \111 <br />y--- ->> OR DRIVEN 7 I I I <br />IIIII GROUND ROD <br />illlll 4 � � <br />(IIIII <br /><E - — - <br />---------- — (IIIII------------------ III1 <br />-�♦ I <br />c DETAIL <br />E4.2 NOT TO SCALE <br />FINISHED CEILING <br />LINE ( TYPICAL ) <br />D1 <br />RACEWAY & WIRING SCHEDULE <br />(CONTRACTOR FURNISHED - CONTRACTOR INSTALLED) <br />RUN # <br />FROM <br />TO <br />SIZE <br />REMAKS <br />1O <br />480 VAC, <br />3 - PHASE <br />OA <br />VARIES <br />REFER TO "INCOMING WIRE SIZE WITH TEAL PCDU - OFF POWER CONDITIONER" NOTES. <br />SOURCE <br />EC SHALL CONNECT BOTH ENDS. <br />2O <br />AO <br />E1 <br />1/" <br />3-#lAWG,1-#AWG NEUTRAL AND 1-#AWG GROUND. EC SHALL CONNECT AT (A) AND <br />CONNECT TO INPUT POWER TERMINAL IN TEAL POWER CONDITIONER WITH SEALTITE <br />CONDUIT <br />BETWEEN JUNCTION BOX (El) AND REAR OF TEAL UNIT. <br />O <br />© <br />O <br />12" <br />2-#14AWG PLUS GROUND. EC SHALL CONNECT TO SHUNT TRIP DEVICE IN (A) AND CONNECT <br />"EMERGENCY OFF" SWITCH IN BOX <br />CONDUIT <br />(B). <br />O <br />DRIVEN <br />GROUND <br />VERTICAL <br />RISER <br />12" <br />1-#1/OAWG GROUND (WELDING CABLE). EC SHALL CONNECT TO DRIVEN GROUND ROD <br />AND TO COPPER BUS BAR REFER TO BUS BAR BLOCK DIAGRAM. <br />ROD <br />CONDUIT <br />(MGB). <br />1211 <br />2-#14AWG PLUS GROUND. EC SHALL CONNECT TO DOOR INTERLOCK SWITCH AND LEAVE <br />O <br />O <br />O <br />TAILS AT (J) PASS THROUGH BOX (W). <br />CONDUIT <br />INSTALL ONLY IF REQUIRED BY PREVAILING CODES OR REQUESTED BY CUSTOMER. <br />O <br />VERTICAL <br />12" <br />2-#14AWG PLUS GROUND. EC SHALL CONNECT TO "X - RAY IN USE" WARNING SIGN AT BOX (W) <br />AND LEAVE TAILS AT (E). EC SHLL INSURE NO LIVE WIRES IN (E). <br />RISER <br />CONDUIT <br />INSTALL ONLY IF REQUIRED BY PREVAILING CODES OR REQUESTED BY CUSTOMER. <br />O <br />® <br />VERTICAL <br />THREE 2-2" <br />OMEGA FURNISHED CABLES TO BE INSTALLED BY X - RAY EQUPMENT INSTALLERS. <br />CONDUIT FOR MONITOR INTERCONNECT CABLES. <br />RISER <br />CONDUITS <br />EC SHALL LEAVE PULL STRINGS. <br />O <br />© <br />„ <br />MOUNT CONDUIT FLUSH WITH THE FINISHED FLOOR LOCATED WHERE SHOWN AND CONNECTED <br />TO WIRE TROUGH BELOW THE FLOOR. <br />TROIUGH <br />CHASE NIPPLE <br />CONDUIT FOR C - ARM CABLES. <br />O <br />WIRE <br />TWO 2-2" <br />MOUNT CONDUIT FLUSH WITH THE FINISHED FLOOR LOCATED WHERE SHOWN AND CONNECTED <br />TO WIRE TROUGH BELOW THE FLOOR. <br />TROUGH <br />CHASE NIPPLE <br />CONDUIT FOR C - ARM CABLES. <br />10 <br />VARIES <br />VARIES <br />VARIES <br />OMEGA FURNISHED CABLES TO BE INSTALLED BY X - RAY EQUIPMENT INSTALLERS. <br />E.C. SHALL PROVIDE AND INSTALL 3-#lAWG,141 NEUTRAL AND 1-#6AWG GROUND. EC <br />X - RAY <br />TEAL <br />12" <br />SHALL CONNECT TO CIRCUIT BREAKER ON LOAD SIDE OF TEAL UNIT AND CONNECT TO <br />11 <br />GENERATOR <br />UNIT <br />SEALTITE <br />INPUT POWER TERMINALS IN X - RAY GERNERATOR CABINET WITH SEALTITE, PLUS TWO <br />CONNECTORS, BETWEEN TEAL UNIT AND REAR OF X - RAY GENERATOR. <br />E.C. SHALL PROVIDE AND INSTALL THE FOLLOWING: 2-#10AWG AND 1-#10AWG GROUND. <br />RACK <br />TEAL <br />12" <br />EC SHALL CONNECT TO CIRCUIT BREAKER ON LOAD SIDE OF TEAL UNIT AND CONNECT TO <br />12 <br />CABINET <br />UNIT <br />SEALTITE <br />INPUT POWER TERMINALS IN 1-100 RACK CABINET WITH SEALTITE, PLUS TWO CONNECTORS, <br />BETWEEN TEAL UNIT AND REAR OF RACK CABINET. <br />RACK <br />TEAL <br />12" <br />E.C. SHALL PROVIDE AND INSTALL 241 OAWG GROUND. EC SHALL CONNECT TO 15 AMP, 1 P, CB IN <br />13 <br />CABINET <br />UNIT <br />SEALTITE <br />TEAL UNIT (SURGICAL LIGHT) AND LEAVE 10 TAILS AT RACK CABINET WITH SEALTITE, PLUS TWO <br />CONNECTORS, BETWEEN TEAL UNIT AND REAR OF RACK CABINET. <br />IMAGING <br />TEAL <br />12" <br />2-#14AWG PLUS GROUND. EC SHALL COANNECT TO 20 AMP, 1 P, CB IN TEAL UNIT <br />14 <br />CABINET <br />UNIT <br />SEALTITE <br />(IMAGING CABINET). CONNECT TO TEAL UNIT WITH A 6 FT. PIECE OF 2" DIA. SEALTITE. <br />15 <br />O <br />VERTICAL <br />RISER <br />Y4" <br />2414AWG PLS GROUND. EC SHALL CONNECT TO SURGICAL LIGHT AND LEAVE 1 O' TAIL AT RACK <br />CABINET. <br />CONDUIT <br />SPECIAL ELECTRICAL NOTES <br />NOTES: <br />SEE ATTACH OMEGA MEDICAL IMAGING DRAWINGS FOR DETAILED EQUIPMENT ON CONTRACTOR FURNISHED / <br />OMEGA MEDICAL IMAGING FURNISHED. <br />ALL JUNCTION BOXES, CONDUIT, DUCT, DUCT DIVIDERS, SWITCHES, CIRCUIT BREAKERS, ETC., ARE TO BE <br />SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR. <br />CONDUIT AND DUCT RUNS SHALL BAVE SWEEP RADIUS BENDS. <br />CONDUIT AND DUCT ABOVE CEILING OR BELOW FINISHED FLOOR MUST BE INSTALLED AS NEAR TO CEILING <br />OR FLOOR AS POSSIBLE TO REDUCE RUN LENGTH. <br />GROUNDING <br />1. PROVIDE REDUNDANT GROUNDING OF ALL EQUIPMENT. <br />2. PROVIDE GROUND BUSHINGS OF ALL NIPPLES. <br />3. PROVIDE GROUND HUMPERS AT ALL DUCT JOINTS. <br />4. ALL OMEGA MEDICAL IMAGING CABINETS MUST BE CONNECTED TO THE DUCT OR JUNCTION BOXES <br />WITH DIRECT BONDING OR HUMPER WIRES. <br />5. PROVIDE GROUND WIRE FROM DUCT OR JUNCTION BOXES TO T.V. MONITOR OR X - RAY TUBE UNIT. <br />SEPARATIONS <br />1. ALL CABLES MUST BE SEPARATED BY VOLTAGE MARKED ON CABLES AND BY CLASS FROM OTHER <br />CABLES. <br />2. DUCT DIVIDERS MUST AVE PROPER CROSS OVERS TO KEEP CLASS WIRING SEPARATED. <br />3. DIGTAIL WIRING, POWER, BUSS CABLES, COAXIAL CABLES MUST BE KEPT IN SEPARATE DUCT <br />COMPARTMENT FOR ENTIRE RUN. <br />4. TERMINATION POINTS OF MONITORS, VCR'S, ETC. REQUIRE SEPARATE JUNCTION BOXES AND <br />COVERPLATES FOR POWER AND VIDEO WITH BLANK COVERPLATES REQUIRED. INDIVIDUAL CONDUIT <br />RUNS ARE SUGGESTED WHEN POSSIBLE. <br />PROVIDE LISTING OF CABLE TYPES AND CLASS IN DUCTS AND CONDUIT FOR REVIEW AT FINAL INSPECTION. <br />COORDINATE ALL WORD ON THIS SHEET WITH OMEGA MEDICAL IMAGING EQUIPMENT SUPPLIERS AND <br />INSTALLERS. <br />Project No. 12010.00 <br />$DATE$ $TIME$ $FILEA$ <br />E4*2 <br />I©2012 BH/PK Architects, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.