My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (129)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (129)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:36:20 PM
Creation date
2/25/2025 9:48:41 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Rodda Construction
Building Plans - Permit #
12953
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
mim <br />If'Or <br />141,070d, <br />N <br />0 <br />CD <br />v <br />N <br />0 <br />I I <br />cn o <br />a <br />N <br />O <br />Cn o <br />00 <br />0 <br />I <br />.a <br />1 <br />`I <br />LDRP %a o i <br />T <br />Stan <br />Lounge <br />I i Womens <br />Locker <br />Scrubs Holding I <br />I <br />i ( CVICTIAI(_'')" QDDIAIVI CD hAA1K1 <br />FIRE PROTECTION DEMOLITION PLAN <br />SCALE: %" = 1' - 0" <br />1 <br />Toilet i <br />j i Toilet <br />WL.j <br />Staff <br />Lounge <br />Womens <br />_ <br />Locker <br />L-_ <br />i <br />-.__ _... _.. _ _. — .•, � <br />III <br />__—T <br />LDRP <br />I <br />II11 <br />Closet <br />Work <br />---- <br />----------- <br />r <br />- <br />op <br />-- - --- - —�-— - --- <br />- - --- - - - -�. <br />-. _. <br />_�- _ <br />� <br />r <br />C-Section I� <br />_ <br />I <br />- - - - <br />I <br />F <br />�- <br />I <br />SCOPE <br />OF WORK <br />I <br />1r, <br />1rr j I <br />4— <br />li-------------------------- <br />ELEC. <br />=- <br />0, 1 <br />� • <br />I <br />I 1 <br />Ili <br />� i� - <br />-------- <br />FIRE PROTECTION PLAN - NEW WORK <br />SCALE. / = 1'- 0 <br />TEE CLAMP, CENTER ON TILES P <br />ON ARCH. REFLECTED CEILING I <br />CEILING TILE <br />CEILING GRID TEE - <br />It <br />SPRINKLER BRANCH LINE OUTLET <br />(SPRINKLER OUTLET SHALL BE TO <br />THE SIDE, NOT DOWN.) <br />\ TYPICAL SPRINKLER HEAD <br />FLEXIBLE PIPE OPTION <br />1" CAST II <br />SCR. 90 E <br />1" CAST IRON SCR. 90 DEG. <br />ELL OR TEE (AS REQ'D) <br />SPRINKLER BRANCH LINE PIPING <br />(SPRINKLER OUTLET MAY BE TURNED <br />DOWN, DEPENDING ON SITUATION.) <br />1" PIPING TO PENDENT SPRINKLER HEAD <br />LINE OF SUSPENDED CEILING <br />u <br />TYPICAL SPRINKLER HEAD —Z <br />HARD PIPE OPTION <br />SUPPLY DETAIL FOR SEMI RECESSED SPRINKLER HEADS <br />NTS <br />SPRINKLER SYMBOL DESCRIPTION <br />SYMBOL <br />SIZE <br />TYPE <br />RESP <br />FINISH <br />TEMP <br />K-FACTOR <br />• <br />o <br />% <br />CONCEALED <br />QR <br />WHITE <br />165 <br />5.6 <br />NOTE: NOT ALL SYMBOLS SHOWN MAY BE REQUIRED FOR THIS PROJECT <br />NOTES <br />1. THIS BUILDING SHALL BE PROTECTED THROUGHOUT BY AUTOMATIC <br />SPRINKLERS. THE DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE <br />WITH NFPA 13, LATEST ENFORCEABLE EDITION. <br />2. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES AND ALL GOVERNMENT <br />REQUIREMENTS. <br />3. ALL AREAS SHALL BE FIRE SPRINKLERED. THIS SHALL INCLUDE ELEVATOR <br />EQUIPMENT ROOMS, ELEVATOR SHAFT PIT, ELECTRICAL ROOMS, <br />TELEPHONE ROOMS, AND ANY CONCEALED SPACES OF COMBUSTIBLE <br />CONSTRUCTION. <br />4. REFER TO ARCHITECTURAL REFLECTED CEILING AND ELECTRICAL LIGHTING <br />DRAWINGS FOR CEILING DESCRIPTIONS AND HEIGHTS. <br />5. THE LOCATIONS OF SIAMESE CONNECTION, RISERS, FEED MAINS, CROSS <br />MAINS AND BRANCH PIPING WHERE SHOWN ON THE DRAWINGS IS APPROXIMATE. <br />FINAL LOCATION IS THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE IN <br />COMPLIANCE WITH THE SPECIFICATIONS AND ALL APPLICABLE CODES OR <br />REGULATIONS. <br />6. PROVIDE HEADS GUARDS FOR SPRINKLERS IN ELECTRICAL ROOMS, ELEVATOR <br />MACHINE ROOMS AND ANY HEADS THAT ARE SUBJECT TO MECHANICAL DAMAGE <br />AND/OR BELOW 7'-0" <br />7. NOT ALL PIPING, VALVES AND APPURTENANCES ARE SHOWN ON PLANS. <br />REFER TO PIPING AND RISER DIAGRAMS, DETAILS AND SPECIFICATIONS <br />FOR ADDITIONAL INFORMATION. <br />8. INSPECTOR'S TEST CONNECTIONS SHALL BE PROVIDED FOR ALL ZONES SO <br />THAT THE WATER FLOW SWITCH FOR EACH ZONE CAN BE TESTED. <br />CONNECTIONS SHALL HAVE A MINIMUM 1 1/2 INCH OUTLET AND DRAIN <br />VALVE LOCATED IN AN ACCESSIBLE LOCATION PIPED TO AN APPROVED <br />LOCATION. <br />9. PROVIDE ACCESS PANELS 1*0 ALL VALVES ABOVE NON- ACCESSIBLE CEILINGS <br />AND CHASES. <br />10. ALL VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY <br />SUPERVISED. TYPE AND EXACT LOCATION OF FLOW AND SUPERVISORY <br />SWITCHES SHALL BE ACCOMPLISHED BETWEEN THE DIFFERENT RESPONSIBLE <br />TRADES. <br />11. PROVIDE A PERMANENTLY ATTACHED NAME TAG STATING THE REQUIRED <br />DESIGN CRITERIA FOR EACH HYDRAULICALLY DESIGNED SYSTEM. <br />12. ALL SPRINKLER HEADS MOJNTED IN CEILING SHALL BE LOCATED A MINIMUM <br />OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER <br />VERTICAL INTERSECTING STRUCTURAL SURFACE. <br />13. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 48" OR <br />WIDER. <br />14. PROVIDE ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER <br />INSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN <br />PROPER CLEARANCES. VERIFY STRUCTURAL, MECHANICAL, ELECTRICAL <br />INSTALLATIONS TO AVOID OBSTRUCTIONS OR INTERFERENCE WITH FIRE <br />PROTECTION PIPE ROUTING. <br />15. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS. FIRESTOPPING SHALL <br />BE OF A U.L. LISTED ASSEMBLY. <br />16. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL DIFFUSERS, <br />SPEAKERS, LIGHTING FIXTURES, CEILING SYSTEMS AND STRUCTURAL <br />SYSTEM. <br />17. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT. NO <br />INSTALLATION SHALL BE PERMITTED UNTIL SPRINKLER SHOP DRAWINGS HAVE <br />BEEN APPROVED. <br />18. DESIGN CRITERIA: <br />A. ALL LIGHT HAZARD AREAS (OFFICES, TREATMENT ROOMS, ETC.) <br />SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF <br />0.10 GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SQ. <br />FT. AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE. <br />B. ALL ORDINARY HAZARD AREAS (MECHANICAL ROOMS, STORAGE AREAS, <br />ETC.) SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF 0.20 <br />GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SO. FT. <br />AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE AND <br />A 150 GPM OUTSIDE HOSE STREAM ALLOWANCE. <br />20. UNLESS OTHERWISE NOTED, ALL SPRINKLER HEADS TO BE QUICK RESPONSE. <br />LEGEND <br />EXISTING PIPE design <br />NEW PIPE Heery International Inc. <br />4700 Millenia Boulevard, <br />PIPING TO BE Suite 550, <br />REMOVED Orlando, Florida 32839 <br />407.992.6300 <br />NEW TO EXISTING EB 0005176 <br />Seal: <br />LIMIT OF REMOVAL <br />"S S. Per, <br />f �' No 44604 � � , <br />r r*= <br />o/ <br />AIA <br />JAME S. PETERKIN - PE #44604 <br />U <br />U <br />O <br />+f <br />U <br />Q <br />Ln <br />cc <br />NQ <br />W N <br />•� 00 <br />co <br />CD co <br />N N <br />U C <br />0.�jm� <br />— Cl) F <br />O CID <br />J � D N <br />'T o <br />Y <br />co <br />0 U <br />4J n N z <br />4-1 o <br />co <br />o C <br />C <br />00 LL <br />0 <br />L <br />CD <br />� N <br />I <br />o <br />i � o <br />0 <br />r <br />Cz <br />J <br />Cll� <br />U <br />z <br />Q Cn <br />z <br />O <br />N <br />U m <br />LU -- <br />O ICE o <br />C� <br />LU <br />� O <br />LL L_L <br />Project No. 12010.00 <br />F1- . 2 <br />02012 BWPK Architects, Inc. <br />$DATE$ $TIME$ $F/LEAS <br />
The URL can be used to link to this page
Your browser does not support the video tag.