Laserfiche WebLink
0 <br />0 <br />00 <br />X <br />U <br />�a <br />a:) <br />(Da <br />4� <br />Uri c, <br />N <br />U <br />N � <br />04 00 <br />N X <br />�U <br />N <br />y <br />as <br />rn <br />/ <br />SHEET NO. SHEET REFERENCE NO. TITLE <br />1 G1001 COVER <br />2 G1002 SHEET INDEX LEGEND AND GENERAL NOTES <br />1. THESE DRAWINGS HAVE BEEN PREPARED, IN PART, BASED UPON RECORD DRAWINGS AND/OR CAD FILES <br />GENERAL <br />3 GC101 MAINTENANCE OF TRAFFIC PLAN <br />FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THOSE UTILIZING THE <br />4 CD101 DEMOLITION PLAN <br />INFORMATION ON THESE DRAWINGS ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY <br />ALL WORK AND ALL MATERIALS FURNISHED SHALL BE IN REASONABLY CLOSE <br />BEFORE USING IT FOR ANY PURPOSE. <br />CONFORMITY WITH THE LINES, GRADES, GRADING SECTIONS, <br />5 CS101 SITE PLAN <br />CROSS -SECTIONS, DIMENSIONS, MATERIAL REQUIREMENTS, AND TESTING <br />6 CS501 DETAILS <br />2. THE ACTUAL LOCATION AND ELEVATION OF ALL UTILITIES SHALL BE FIELD VERIFIED BY THE CONTRACTOR <br />REQUIREMENTS THAT ARE SPECIFIED IN THE CONTRACT, PLANS, <br />PRIOR TO THE START OF CONSTRUCTION. <br />SPECIFICATIONS, OR MANUFACTURER RECOMMENDED INSTALLATION <br />7 CS502 DETAILS <br />METHODS. <br />3. IN THE EVENT OF DAMAGE TO EXISTING UTILITIES OR CABLES, THE ENGINEER AND OWNER SHALL BE <br />NOTIFIED IMMEDIATELY. <br />GENERAL REQUIREMENTS FOR SCOPE OF THE WORK, CONTROL OF THE WORK, <br />4. THE CONTRACTOR SHALL REPAIR ALL DAMAGE TO UTILITIES OR CABLES, AS DIRECTED BY THE ENGINEER, <br />CONTROL OF MATERIALS AND OTHER GENERAL REQUIREMENTS AND <br />IMMEDIATELY AND AT THE CONTRACTOR'S EXPENSE. <br />CONSTRUCTION DETAILS NOT COVERED IN THE CONTRACT OR ON THE PLANS <br />SHALL FOLLOW FLORIDA DEPARTMENT OF TRANSPORTATION, STANDARD <br />5. ALL AREAS DISTURBED AS A RESULT OF THE CONTRACTOR'S STAGING AND CONSTRUCTION OPERATIONS <br />SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION. <br />SHALL BE RESTORED EQUAL TO OR BETTER THAN ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE. <br />MAINTENANCE OF TRAFFIC <br />6. ALL DIRT, DUST, STONES AND LOOSE DEBRIS SHALL BE CONTINUOUSLY REMOVED FROM ALL PAVED <br />SURFACES DURING THIS CONTRACT. <br />PLASTIC DRUM BARRICADES SHALL BE INSTALLED AS NOTED ON GC101 AND <br />COORDINATED WITH HOSPITAL PERSONNEL. <br />7. ALL OF THE CONTRACTOR'S OPERATIONS SHALL REMAIN ON PROPERTY AT ALL TIMES. UNDER NO <br />STAGING AND ACCESS SHALL BE COORDINATED WITH HOSPITAL PERSONNEL. <br />C1 <br />SHEET INDEX <br />CIRCUMSTANCES WILL THE CONTRACTOR BE ALLOWED ON ADJACENT PROPERTY. <br />8. THIS CONTRACT DOES NOT ALLOW FOR PRICE INCREASES DUE TO ESCALATION IN COST OF UNIT BID ITEMS. <br />DEMOLITION <br />SCALE: NOT TO SCALE <br />THE CONTRACTOR SHALL TAKE THIS INTO CONSIDERATION WHEN PREPARING UNIT PRICES FOR BID. <br />SIDEWALK AND DEMOLITION: SIDEWALK AND CURB SHALL BE REMOVED AS <br />9. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL STRIP AND STOCKPILE ALL MATERIAL <br />SHOWN ON THE PLANS. A 3-FOOT TRANSITION SHALL BE SAWED INTO THE <br />SUITABLE FOR TOPSOILING. <br />EXISTING CURB OR A 3 FOOT TRANSITION INSTALLED. <br />KEYED NOTE REFERENCE <br />10. SELECTIVE GRADING SHALL BE REQUIRED AS DIRECTED BY THE ENGINEER. <br />FENCE REMOVAL: THE FENCE AND FOUNDATION SHALL BE REMOVED AS <br />EXISTING RUNWAY OR TAXIWAY <br />SHOWN ON THE PLANS. TWO NEW TERMINAL POSTS WILL BE REQUIRED TO BE <br />EDGE LIGHT TO BE REMOVED <br />11. ALL SPOIL SHALL BE DISPOSED OF OFF -SITE AT THE CONTRACTORS EXPENSE. <br />INSTALLED. <br />PROPOSED IN -PAVEMENT EDGE LIGHT <br />12. ALL ELECTRICAL WORK SHALL CONFORM TO APPLICABLE LOCAL, STATE AND NATIONAL ELECTRICAL CODES. <br />MARKING REMOVAL: ALL MARKINGS LOCATED ON THE HELIPORT SHALL BE <br />REMOVED. <br />HELIPORT SAFETY AREA <br />13. THE ELECTRICAL CHARACTERISTICS OF PROPOSED EQUIPMENT SHALL BE VERIFIED TO BE COMPATIBLE WITH <br />EXISTING EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. <br />LIGHT REMOVAL: EIGHT (8) LIGHTS SHALL BE REMOVED INCLUDING THE WOOD <br />FINAL APPROACH AND TAKEOFF AREA (FATO) <br />MOUNTING POST TO A DEPTH OF 12-INCHES BELOW EXISTING GRADE. <br />TLOF TOUCHDOWN AND LIFT OFF AREA (TLOF) <br />14. ABANDONED CABLES MAY EXIST IN THE VICINITY OF THE PROPOSED WORK. IF ENCOUNTERED, CONTRACTOR <br />SHALL VERIFY THAT THEY ARE ABANDONED PRIOR TO REMOVAL. IF THEY ARE NOT ABANDONED, CABLES <br />SITE RESTORATION <br />EXISTING SIDEWALK AND <br />SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. <br />PROVIDE LANDSCAPE SOIL AND SOD TO INFILL THE REMOVED SIDEWALK AND <br />CURB TO BE REMOVED <br />15. ITEMS OF SPECIFIC MANUFACTURE SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S <br />CURB. <br />PRINTED INSTRUCTIONS AND OR MANUFACTURER'S REPRESENTATIVE DIRECTIONS. <br />+ + + + + + + + PROPOSED SITE GRADING <br />PAINTING AND SEALING <br />+ + + + + <br />16. ALL GROUND CONNECTIONS SHALL BE MADE USING EXOTHERMIC CONNECTIONS. <br />HELIPORT IDENTIFICATION SYMBOL WITH CROSS: THIS MARKING SHALL BE <br />o PLASTIC DRUMS FOR MOT <br />17. ALL CABLE CONNECTIONS SHALL BE MADE AT LIGHT UNITS OR AT ENDS OF DUCT BANKS UNLESS DIRECTED <br />PAINTED RED ON A WHITE CROSS PER THE PLANS. <br />— — ELECTRICAL CONDUIT <br />OTHERWISE, <br />TLOF SIZE/WEIGHT LIMITATION "BOX": THIS MARKING SHALL BE PAINTED BLACK <br />18. THE OWNER RESERVES THE RIGHT TO SALVAGE LIGHTING EQUIPMENT. THE EQUIPMENT TO BE SALVAGED IS <br />WITH A WHITE BACKGROUND PER THE PLANS, <br />IDENTIFIED IN THE SPECIFICATION. SALVAGED EQUIPMENT SHALL BE STOCKPILED AT A LOCATION <br />DESIGNATED BY THE OWNER IN PROPER WORKING CONDITION. ALL OTHER LIGHTING EQUIPMENT SHALL BE <br />TLOF EDGE MARKING: THIS MARKING SHALL BE PAINTED WHITE PER THE PLANS. <br />SPOILED OFF AIRPORT PROPERTY AT A PROPER DISPOSAL SITE SELECTED BY THE CONTRACTOR. <br />AREA BETWEEN THE CROSS AND TLOF EDGE MARKING: THIS MARKING SHALL <br />19. PROVIDE WATERTIGHT TERMINATION FOR ALL BURIED CONDUIT ENDS. <br />BE PAINTED RED PER THE PLANS. <br />ALL MARKINGS EXCEPT BLACK SHALL HAVE REFLECTIVE MEDIA. <br />AREA OUTSIDE TLOF EDGE MARKING: THIS AREA SHALL BE SEALED WITH A <br />LEGEND <br />B 1 <br />COMMERCIAL GRAY SOLID COLOR SOLVENT BASED CONCRETE SEALER. <br />SCALE: NOT TO SCALE <br />ELECTRICAL <br />THE CABLE, CONDUIT AND LIGHTS SHALL BE INSTALLED PER THE PLANS, TO <br />APPLICABLE LOCAL, STATE AND NATIONAL ELECTRIC CODES AND <br />MANUFACTURER REQUIREMENTS. <br />A <br />A2 <br />GENERAL NOTES <br />A4 <br />SUMMARY OF WORK <br />SCALE: NOT TO SCALE <br />: NOT TO SCALE <br />1 <br />CCl <br />OS <br />C&S Engineers, Inc. <br />605 E. Robinson Street, Suite 210 <br />Orlando, FL 32801 <br />Phone: 407-422-1118 <br />Fax. 407-841-9149 <br />www.cscos.com <br />Douglas R. Saundett', t?te of Florida, <br />Professional' Nineer, Lie' No. 67691. <br />This iterj: f been electrAi`c'b4 signed and <br />sealed by Douglds'R'. Saur ders on the date <br />indicated here using a SHA authentication <br />code. �o <br />Printed copies of this document are not <br />considered signed ancf sealed and <br />the SHA authenticatior'�ode must be <br />verified on any elecfi nic copies. <br />Q <br />0 F— <br />0 Of <br />C O <br />J <br />J <br />N O W <br />W <br />J <br />U) J <br />J — <br />W <br />N W <br />= N <br />Q H <br />� <br />2 <br />LU <br />Z <br />W = <br />> F_ <br />J Q Z <br />J <br />a w <br />0 <br />0 <br />cL <br />w <br />c Q <br />U <br />MARK <br />DATE <br />DESCRIPTION <br />REVISIONS <br />PROJECT NO: X88.001.001 <br />DATE: OCTOBER 2021 <br />DRAWN BY: K.M. WATSON <br />DESIGNED BY: K.M. WATSON <br />CHECKED BY: D R. SAUNDERS <br />SHEET INDEX <br />LEGEND AND <br />GENERAL NOTES <br />G1002 <br />Copyright <br />