Laserfiche WebLink
0 <br />a <br />N <br />a <br />o_ <br />fn o <br />N, <br />0 <br />v- <br />N <br />f� <br />FLORIDA HOSPITAL PHYRHI S <br />Sleep Lab / Pixnac3iaologist Office <br />7209 C-irreeiisIc3pe ]Dr <br />Zeplzyrhills, Florida 33541 <br />PROJECT TEAM DIRECTORY <br />OWNER <br />Florida Hospital Zephyrhills <br />7050 Gall Boulevard <br />Zephyrhills, Florida 33541 <br />Phone: (813) 788-0411 <br />ARCHITECT <br />Burt Hill / Pollock Krieg Architects, Inc. <br />8250 College Parkway, Suite 203 <br />Fort Myers, Florida 33919 <br />Phone: (239) 482-4761 <br />Fax: (239) 482-0265 <br />MEP ENGINEER <br />Smith Seickman Reid, Inc. <br />6948 Professional Parkway East <br />Sarasota, Florida 34240 <br />Phone: (941) 907-7750 <br />Fax: (941) 907-7751 <br />Industry standards (I.e. ASTM, ANSI, etc.) SHALL HAVE THE SAME FORCE AND EFFECT <br />on performance of work as If copies were directly Inserted into the Contract Documents or bound and <br />published therewith. Comply with standards In effect as of the date of the Contract Documents, <br />unless otherwise note or required by authorities having jurisdiction. <br />CODES - All work shall conform to the following codes and ordinances: <br />2007 Florida Building Code, with (2) 2009 amendments <br />2007 Florida Plumbing Code, with 2009 amendments <br />-2007 Florlda Fuel Gas Code, with 2009 amendments <br />- 2007 Florida Mechanical Code, with 2009 amendments <br />2007 Florida Fire Prevention Code <br />Local Codes and Ordinances where applicable and flood damage prevention ordinances <br />2006 NFPA 101 - Life Safety Code <br />SYMBOLS AND MATERIALS <br />NOTE: The symbols here are specific to the Architectural Drawings as a whole. <br />The Life Safety, Reflected Ceiling Plan and Roof Plan respectively Include supplementary legends <br />and drawing notes specific to those sheets. Refer to other disciplines for additional symbols. <br />AO WINDOW TYPE <br />ELEVATION BENCHMARK <br />REVISION AND NUMBER <br />C.J.D CONTROL JOINT <br />124 <br />DOOR AND FRAME <br />WITH DOOR NUMBER <br />EXISTING DOOR <br />METAL STUD WALL <br />MASONRY WALL <br />EVALUATION <br />208 <br />ROOM NAME AND NUMBER <br />WALL TYPE <br />BUILDING SECTION <br />SECTION OR DETAIL <br />ELEVATION <br />® <br />INTERIOR ELEVATION <br />NORTH <br />NORTH ARROW <br />EARTH <br />GRANULAR FILL <br />METAL <br />® <br />FINISH WOOD <br />VICINITY MAP <br />STUCCO OR GYPSUM BOARD <br />CONCRETE OR GRAVEL <br />CONCRETE MASONRY UNIT (CMU) <br />® PLYWOOD <br />ACOUSTIC CEILING TILE <br />BATT OR SEMI -RIGID INSULATION <br />RIGID INSULATION <br />ROUGH WOOD FRAMING OR BLOCKING <br />0 <br />2x2 LAY -IN FLUORESCENT FIXTURE <br />0 <br />2x4 LAY -IN FLUORESCENT FIXTURE <br />'—O—' <br />FLUORESCENT UTILITY FIXTURE <br />o <br />RECESSED DOWNLIGHT <br />X <br />SUPPLY AIR DIFFUSER <br />Z <br />RETURN AIR REGISTER <br />$?'17 <br />FINISH CEILING ELEVATION <br />(All elevations are A.F.F.) <br />® <br />EXIT LIGHT <br />2x2 ACOUSTICAL CEILING TILE <br />2x4 ACOUSTICAL CEILING TILE <br />GYPSUM BOARD <br />MAGNETIC DOOR HOLDER <br />— Project <br />INDEX OF DRAWINGS <br />A0.0 Cover Sheet <br />ARCHITECTURAL <br />SP.I <br />Site Plan <br />A2.0 <br />Demo Plan <br />A2.1 <br />Floor Plan / Interior Elevations <br />A2.2 <br />Reflected Ceiling Plan and Details <br />A2.3 <br />Wall Finishes Plan <br />A2.4 <br />Floor Finishes Plan <br />A4.0 <br />Cabinet Sections <br />A5.0 <br />Schedules and Details <br />MECHANICAL <br />M0.1 <br />Schedules, Legends, and Index <br />Ml.l <br />HVAC Plan- New Construction <br />M2,1 <br />HVAC Details <br />PLUMBING <br />P0.1 <br />Schedules, Notes & Sheet Index <br />P 1.1 <br />Plumbing Plan- New Construction <br />ELECTRICAL <br />E0.1 <br />Symbol Legend & Drawing Index <br />E L I <br />Lighting Plan - New Construction <br />E2.1 <br />Power Plan - New Construction <br />E3.1 <br />Systems Plan- New Construction <br />IUBMMED PLAN(S) <br />BY ZEPHYRHILLS F7� <br />Reviewer: --- <br />Pleat be advised this review of Plans subrtiRted is aHance vrfttt <br />perry review to assist the contractor <br />h revie not intended <br />applicable fire safety codes ems. It is the <br />to be a final apPron+� of submitted P Ions are in <br />contractor's sole responsibility to ensure that the P <br />complete compliance with all applicable NFPA codes and <br />n or <br />local ordinances. In the event that further iea xamlit shall be <br />site inspection reveals area of non � <br />n�iliry, at their sole expense to <br />the contractors sole ram° fiance. The City assumes no <br />bring those areas in comp <br />responsibility for the contractor's failure to be in <br />with all applicabMPOMM <br />le NFPA Codes an <br />d local <br />REVIEWED <br />S OFFICE <br />7-� <br />--tk 1052c� <br />REVIEW bffe " 0 <br />;;ITN' 0F 7EPHYRHILLS <br />PLANS EXAMINER <br />I - ----- P____ <br />r ' n,, �1 ` ,L[. Co\dill` WITHALL <br />� i�i�ATAILIN(i CODES, FLORIDA BUILDRI, <br />CODE, N,'JI ON AL ELECTRIC CODE AN) <br />CI-EY of GLi 1iYR1T1ILLS ORDINANCES <br />U <br />�i <br />�7J <br />.ems <br />�p <br />eq <br />C <br />N <br />U <br />o M <br />M <br />0 <br />'C N C� <br />o� <br />U <br />00wa.,a <br />a <br />T_y <br />a <br />� o <br />o <br />�N <br />v <br />� <br />m <br />0 <br />t r--� <br />Cn <br />c <br />ct <br />Q <br />ct <br />ct <br />7� <br />Project No. 10006.01 <br />411912010 2:42:59 PM ...\cd\AO-0 Cover Sheet.dgn <br />1 ©2010 BH/PK Architects, Inc. I <br />