ld�llJ.l i. 111I.: _7. !JJ.if.LLl. l L L.... ,I_L A, .1--i,..dlL.d <br />1 <br />N - <br />29 <br />0 <br />R <br />V_ <br />N <br />a <br />�h <br />rn o <br />N <br />O <br />tw-) o <br />0 <br />o <br />N <br />0 <br />v- <br />N <br />9 <br />Lo <br />MECHANICAL GENERAL NOTES <br />1. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL <br />POSSIBLE CONDITIONS. IT IS INTENDED THAT A COMPLETE SYSTEM BE PROVIDED WITH <br />ALL NECESSARY EQUIPMENT, APPURTENANCES, AND CONTROLS, COMPLETELY <br />COORDINATED WITH ALL DISCIPLINES. ALL PARAMETERS GIVEN IN THESE DOCUMENTS <br />SHALL BE STRICTLY CONFORMED WITH. ANY ITEMS AND LABOR REQUIRED FOR A <br />COMPLETE SYSTEM IN ACCORDANCE WITH ALL APPLICABLE CODES, STANDARDS, AND <br />THESE CONTRACT DOCUMENTS SHALL BE FURNISHED WITHOUT INCURRING ANY <br />ADDITIONAL COST TO THE OWNER. CAREFULLY REVIEW ALL CONTRACT DOCUMENTS <br />AND THE DESIGN OF OTHER TRADES BEFORE PREPARING SHOP DRAWINGS. <br />2. COORDINATE EQUIPMENT AND DUCTWORK WITH ALL OTHER DISCIPLINES AND TRADES. <br />MAKE ALL OFFSETS AND TRANSITIONS TO COORDINATE WITH OTHER TRADES <br />WITHOUT ANY ADDITIONAL EXPENSE TO THE OWNER. <br />3. COORDINATE THE EXACT LOCATION AND SIZE OF ALL ROOF, WALL, AND SLAB <br />PENETRATIONS WITH THE ARCHITECTURAL DRAWINGS. <br />4. MOUNT THERMOSTATS WHERE INDICATED ON PLANS, 5'-0" A.F.F. UNLESS NOTED <br />OTHERWISE. <br />5. ALL ITEMS INDICATED BY THE MECHANICAL DRAWINGS TO BE REMOVED SHALL BE <br />PRESENTED TO THE OWNER IN USEABLE CONDITION. ITEMS NOT RETAINED BY <br />THE OWNER SHALL BE DISPOSED OF LEGALLY BY THE CONTRACTOR. <br />6. REFER TO HVAC DETAILS FOR ADDITIONAL REQUIREMENTS. <br />7. ANY FAILURE OF EQUIPMENT, SYSTEM, OR UTILITY THAT MAY AFFECT OTHER AREAS <br />OUTSIDE THE PROJECT AREA SHALL REQUIRE IMMEDIATE CORRECTIVE ACTION BY <br />THE CONTRACTOR AND SUBCONTRACTORS, WITHIN ONE HOUR DURING DAY SHIFT <br />MONDAY FRIDAY, AND WITHIN FOUR HOURS ON NIGHTS AND WEEKENDS. <br />8. EQUIPMENT SIZES AND SERVICE SPACE REQUIREMENTS MAY VARY BETWEEN DIFFERENT <br />MANUFACTURERS, CONSULT MANUFACTURERS AS SUBMITTED AND APPROVED FOR <br />APPLICATION WITH THIS DRAWING. <br />9. DO NOT BLOCK SERVICE SPACE ONE UIPMENT WITH DUCTWORK ETC... <br />(FLANGED OR REMOVABLE SECTIONS MAY BE USED IN SOMEINSFANCES <br />WHERE TIGHT CLEARANCE EXISTS). <br />DUCTWORK NOTES <br />1. ALL SUPPLY AIR DUCTWORK SHALL BE RECTANGULAR OR ROUND <br />AS INDICATED, SEE SPECS FOR ADDITIONAL REQUIREMENTS. <br />2. ALL DUCTWORK IS SHOWN AS FREE AREA INSIDE DIMENSIONS. <br />3. USE SPIN -IN AND VOLUME DAMPER FOR ROUND TAKE OFFS <br />FROM SQUARE DUCT. <br />4. USE 45 DEG. TAPS FOR ROUND TO ROUND TAKE OFF'S. <br />PROVIDE VOLUME DAMPERS AT EACH TAKE OFF <br />5. DO NOT CONSTRUCT OR INSTALL TAPS OUT OF REDUCERS, <br />TEES AND OR ELBOWS. <br />6. ALLOW FOR FIELD MEASURED OFFSETS OR TRANSITIONS, ELBOWS ETC. <br />7. DOVETAIL AND/OR SEAL TIGHT FACE MOUNTED TAP -INS ARE NOT ACCEPTABLE. <br />8. SUPPORT ALL FLEXIBLE DUCTWORK AS INDICATED IN <br />SMACNA FIGURE 3-9, 1985 BUT NOT LESS THAN 5'-0" O.C. <br />9. DO NOT USE FLEX DUCT IN EXPOSED AREAS, ABOVE GYPSUM CEILINGS, <br />OR ABOVE FIRE RATED CEILINGS. <br />10. GRILLES, REGISTERS AND DIFFUSERS CONNECTED BY FLEXIBLE <br />DUCT SHALL BE SUPPORTED INDEPENDENTLY OF THE FLEXIBLE DUCT. <br />11. ELBOWS SHALL BE 90 DEG. ELLS WITH DOUBLE THICKNESS TURNING <br />VANES. OR WHERE SPACE PERMITS RADIUS FITTING WITH CENTERLINE <br />RADIUS EQUAL TO 11/2 TIMES THE DUCT WIDTH CENTERLINE. NO OTHERS <br />WILL BE ALLOWED. <br />12. COORDINATE FINAL LOCATION OF ALL REGISTERS, <br />GRILLES, DIFFUSERS ETC. WITH ARCHITECTURAL DRAWINGS. <br />FAN SCHEDULE <br />BELT GUARD <br />03 OUTLET GRAVITY DAMPERS <br />(1) - HIGH EFFICIENCY MOTOR (SEE SPECS.) <br />0 MOTOR WITH THERMAL OVERLOAD PROTECTION ® LINED HOUSING <br />( 2) - INCLUDES WEIGHT OF INERTIA BASE <br />IDENT <br />SYSTEM <br />TYPE <br />MANUFACTURER MODEL NO. <br />CFM <br />S.P. <br />FRPM <br />MOTOR <br />FAN ACCESS <br />ISOLATORS <br />OPERATING <br />WEIGHT (2) <br />REMARKS <br />MIN. <br />WATTS <br />RPM <br />ELECT, <br />H.R <br />EF-1 <br />GEN. EXHAUST <br />INLINE <br />GREENHECK BSQ-70-4 <br />150 <br />.5 <br />1394 <br />1/4 <br />--- <br />1075 <br />115/60/1 <br />EXTERNAL <br />76 <br />---- <br />EF-2,3,4,5 <br />GEN. EXHAUST <br />CEILING <br />GREENHECK SP-B70 <br />50 <br />1 .25 <br />675 <br />--- <br />45 <br />1 675 <br />1 115/60/1 <br />---- <br />9 <br />---- <br />REGISTER GRILLE & DIFFUSER SCHEDULE <br />SIZES ARE BY THIS SCHEDULE UNLESS NOTED OTHERWISE. DIFFUSERS ARE * BRANCH DUCT AND OPTIONAL BRANCH DUCT SIZES ARE BY THIS SCHEDULE UNLESS OTHERWISE <br />4-WAY BLOW UNLESS NOTED AS 3-WAY ((3-W OR 2-WAY (2-W), GO TO NEXT SPECIFICALLY NOTED ON FLOOR PLANS. <br />LARGER NECK SIZE FOR 2-W OR 3-W DIFFL 0. USE RETURN/EXHAUST REGISTER AND DIFFUSER WITH O.B.D. IN DRYWALL OR INACCESSABLE CEILINGS. <br />UNLESS NOTED OTHERWISE ALL DIFFUSERS IN THE SAME SPACE SHALL BE THE USE RETURN/EXHAUST GRILLES AND DIFFUSERS WITHOUT O.B.D. IN LAY -IN OR ACCESSIBLE CEILINGS. <br />SAME SIZE REGARDLESS R CFM, USING LARGEST SIZE FROM TABLE BELOW. INSTALL M.V.D. IN BRANCH DUCTS. INSTALL SPIN -IN FITTINGS (WITHOUT SCOOPS) WITH M.V.D. IN <br />ALL DIFFUSERS IN THE SAME CORRIDOR SHALL BE THE SAME SIZE. ALL OPTIONAL BRANCH DUCTS. SEE BRANCH DUCT CONNECTION DETAILS FOR SPECIFIC REQUIREMENTS. <br />RETURN AND EXHAUST GRILLES ARE BASED ON 450 FPM & 72% FREE AREA <br />BASED ON 1 2" EGG -CRATE GRILLES). <br />CEILING DIFFUSERS <br />RETURN / EXHAUST REGISTERS & GRILLES <br />CFM RANGE <br />BRANCH UCT SIZE <br />OPTIONAL BRANCH <br />DUCT SIZE * <br />NECK SIZE <br />CFM RANGE <br />BRANCH DUCT SIZE <br />* <br />OPTIONAL BRANCH <br />DUCT SIZE <br />FACE SIZE <br />UP TO 150 <br />10x6 <br />811 <br />4 <br />6110 <br />0 -80 <br />8x6 <br />6110 <br />6x6 <br />151- 280 <br />12x6 <br />10110 <br />811 <br />4 <br />81-140 <br />10x6 <br />8110 <br />8x8 <br />281- 435 <br />148 <br />12110 <br />101TO <br />141- 220 <br />12x6 <br />10114) <br />1Ox10 <br />436 - 630 <br />16x8 <br />12110 <br />12110 <br />221- 320 <br />148 <br />10114) <br />12x12 <br />321- 480 <br />26x6 OR 18x8 <br />12110 <br />18x12 <br />481- 730 <br />20x10 <br />--- <br />18x18 <br />731 -950 <br />20x12 OR 26x10 <br />--- <br />2418 <br />951- 1300 <br />28x10 <br />--- <br />2424 <br />1301- 2000 <br />26x14 OR 38x10 <br />--- <br />36x24 <br />2001- 2800 <br />5410 OR 26x18 <br />--- <br />48x24 <br />SEQUENCE OF OPERATION <br />WHEN ON: <br />THE FAN SHALL RUN CONTINOUSLY. THE AUTO CHANGEOVER ROOM THERMOSTAT <br />SHALL CYCLE THE COMPRESSOR AS TO MAINTAIN THE SETPOINT TEMPERATURE. <br />THE HUMIDISTAT SHALL OVERRIDE THE SPACE THERMOSTAT AND ENERGIZE THE <br />COMPRESSOR IF THE HUMIDITY RISES ABOVE 60% ADJ. IF THE TEMPERATURE <br />REACHES THE HEATING SETPOINT BEFORE THE HUMIDITY IS BELOW 60% THE <br />HEATING COILS SHALL BE ENERGIZED TO PREVENT THE SPACE FROM BEING <br />OVERCOOLED. <br />DRAWING INDEX <br />NUMBER <br />TITLE <br />M0.1 <br />SCHEDULES, NOTES & DRAWING INDEX <br />M1.1 <br />HVAC PLAN - NEW CONSTRUCTION <br />M2.1 <br />HVAC DETAILS <br />Project No. 10006.01 <br />$DATE$ $TIME$ $FILEA$ <br />© 2010 BH/PS Architects, Inc. <br />