Laserfiche WebLink
N <br />0 <br />N <br />0 <br />p <br />R <br />lql <br />M; <br />a- <br />N <br />0 <br />NI <br />0 <br /><,- <br />N <br />0 <br />LIGHTING <br />®SURFACE <br />OR RECESSED FLUORESCENT FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />®SURFACE <br />OR RECESSED FLUORESCENT FIXTURE WITH EMERGENCY <br />BATTERY BACK-UP (TYPE DETERMINES MOUNTING) <br />O <br />SURFACE OR RECESSED FLUORESCENT FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />®® <br />SURFACE OR RECESSED FLUORESCENT FIXTURE WITH EMERGENCY <br />BATTERY BACK-UP (TYPE DETERMINES MOUNTING) <br />® <br />SURFACE OR SUSPENDED FLUORESCENT FIXTURE <br />TYPE DETERMINES MOUNTING <br />® <br />SURFACE OR SUSPENDED FLUORESCENT FIXTURE WITH EMERGENCY <br />BATTERY BACK-UP (TYPE DETERMINES MOUNTING) <br />Q <br />WALL BRACKET FIXTURE <br />OEM <br />WALL BRACKET FIXTURE WITH EMERGENCY BATTERY BACK-UP <br />®1 <br />1 <br />EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED <br />ON PLANS <br />SWITCHES <br />S <br />SINGLE POLE SWITCH - IVORY TOGGLE <br />3'-10" <br />AFF TO CL <br />S3 <br />THREE WAY SWITCH - IVORY TOGGLE <br />3'-10" <br />AFF TO CL <br />SD <br />DIMMER SWITCH <br />3'-10" <br />AFF TO CL <br />❑ <br />PUSH BUTTON SWITCH <br />3'-10" <br />AFF TO CL <br />POWER - RECEPTACLES <br />120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE <br />ABBREVIATIONS FOR EXCEPTIONS) <br />1'-6" <br />AFF TO CL <br />120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT <br />REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS <br />AS NOTED OR <br />SEE SPECS <br />120V. QUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE <br />ABBREVIATIONS FOR EXCEPTIONS) <br />1'-6" <br />AFF TO CL <br />120V. QUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT <br />REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS <br />AS NOTED OR <br />SEE SPECS <br />SPECIAL RECEPTACLE (TYPE AS NOTED) <br />NOTED <br />AS E S ECSR <br />�-- <br />120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT) <br />AS NOTED OR <br />SEE SPECS <br />120V. GFI RECEPTACLE <br />1'-6" <br />AFF TO CL <br />Q <br />JUNCTION BOX <br />RACEWAY <br />CONDUIT & BRANCH CIRCUIT WIRING CONCEALED <br />HOMERUN TO PANELBOARD - NUMBER OF ARROWHEADS INDICATES <br />NUMBER OF #12 AWG PHASE CONDUCTORS. FOR MINIMUM CONDUIT <br />SIZE REQUIRMENT REFER TO SPECIFICATION. <br />NOTES: <br />1. #12 AWG NEUTRAL CONDUCTOR, ALTHOUGH NOT INDICATED, <br />SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE <br />NOTED. <br />2. #12 AWG GREEN GROUND CONDUCTOR ALTHOUGH NOT INDICATED, <br />SHALL BE INCLUDED IN EACH RACEWAYUNLESS OTHERWISE <br />NOTED. <br />3. HOPER <br />))MERUNS TO PANELBOA(RDS ONE SHALL HAVE A MAXIMUM OF THREE <br />�3PHASE <br />CONDUCTORS IN EACH CONDUIT) PLUS NEUTRAL AND <br />SOUND SYSTEM <br />O <br />CEILING PAGING SPEAKER <br />CEILING MTD. <br />V� <br />VOLUME CONTROL <br />46" AFF <br />PE <br />PAGING EQUIPMENT <br />�M <br />MICROPHONE <br />EM D <br />FMICROPHONE <br />CABLE/MATV SYSTEM <br />MATV OUTLET FOR WALL MOUNTED TV <br />(ANTENNA, & REMOTE CONTROL SEE MANUFACTURER'S DETAIL) <br />88" AFF <br />HE <br />HEAD -IN EQUIPMENT <br />TVA <br />MATV AMPLIFIER <br />Evil <br />MATV SYSTEMS JUNCTION BOX (SIZE AS REQUIRED) <br />ABBREVIATIONS <br />ADO <br />AUTOMATIC DOOR OPERATOR <br />AFF <br />ABOVE FINISHED FLOOR <br />AHU <br />AIR HANDLING UNIT <br />BKR <br />CIRCUIT BREAKER <br />C <br />CONDUIT <br />EF <br />EXHAUST FAN <br />EWH <br />ELECTRIC WATER HEATER <br />EX <br />EXISTING TO REMAIN <br />MW <br />MICROWAVE <br />REF <br />REFRIGERATOR <br />RTU <br />ROOF TOP UNIT <br />U/C <br />UNDER COUNTER <br />Wp <br />WEATHER PROOF <br />MISCELLANEOUS <br />4z <br />NON -FUSIBLE SAFETY SWITCH, SIZE AS NOTED <br />q= <br />FUSIBLE SAFETY SWITCH, SIZE AS NOTED <br />® <br />FACTORY WIRED CONTROLLER OR EQUIPMENT <br />ST <br />MOTOR RATED SWITCH WITH THERMAL OVERLOAD <br />0 <br />MOTOR CONNECTION <br />i <br />PANELBOARD - FLUSH MOUNTED <br />MD <br />MOTION DETECTOR <br />SPD SURGE PROTECTION DEVICE <br />TELEPHONE/ DATA <br />TELEPHONE OUTLET WITH PLATE <br />6"'- <br />11- TO CLG <br />TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) <br />AS NOTED <br />SEE SPECS. <br />COMBINATION DATA/TELEPHONE OUTLET WITH PLATE <br />1'-6" <br />AFF TO CLG <br />COMBINATION DATA/TELEPHONE OUTLET WITH PLATE <br />(SPECIAL MOUNTING HEIGHT) <br />AS NOTED <br />SEE SPECS. <br />a <br />DATA OUTLET WITH PLATE <br />1'-6" <br />AFF TO CLG <br />o- <br />DATA OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) <br />AS NOTED <br />SEE SPECS. <br />SOUND SYSTEM <br />Qs <br />CEILING SPEAKER <br />�v <br />VOLUME CONTROL <br />GENERAL ELECTRICAL CONSTRUCTION NOTES <br />1. PROVIDE A TYPED CIRCUIT DIRECTORY CARD PROTECTED BY PLASTIC SLEEVE FOR THE PANELBOARD <br />INSTALLED UNDER THE SCOPE OF THIS PROJECT. THIS DIRECTORY CARD SHALL INDICATE THE <br />SPECIFIC PURPOSE AND LOCATION FOR WHICH EACH CIRCUIT IS UTILIZED. THIS DIRECTORY CARD <br />SHALL MATCH THE ACTUAL INSTALLATION IF DIFFERENT FROM DRAWINGS. <br />2. REFER TO THE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL DESIGN STANDARDS. THE <br />ELECTRICAL SPECIFICATIONS ARE A BINDING PART OF THE CONSTRUCTION DOCUMENTS. <br />3. ELECTRICAL CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS OF THE PROJECT AREA PRIOR <br />TO ISSUING BID. ELECTRICAL CONTRACTOR SHALL DISCUSS WITH OWNER ALL EXISTING CONDITIONS <br />AFFECTING CONTRACTOR BID. <br />LIGHTING FIXTURE SCHEDULE <br />TYPE <br />MANUFACT. <br />CATALOG NO. <br />LAMPS <br />VOLT <br />MOUNTING <br />REMARKS <br />F1 <br />WILLIAMS <br />DIG-S24-332-WPR- <br />(3 32W T8 <br />120 <br />RECESSED <br />2'x4' RECESSED <br />AMW-EBHW3-120 <br />3000K) <br />DIRECT / INDIRECT <br />DIG-S24-232-WPR- <br />(2) 32W T8 <br />2'x4' RECESSED <br />DIRECT / INDIRECT <br />F1E <br />WILLIAMS <br />AWM/EM2-EBHW2- <br />3000K) <br />120 <br />RECESSED <br />W/2-LAMP EMERGENCY <br />120 <br />BATTERY PACK <br />F2 <br />WILLIAMS <br />DIG-S22-217-WPR- <br />(2) 17W T8 <br />120 <br />RECESSED <br />2'x2' RECESSED <br />AWM-EBHW2-120 <br />3000K) <br />DIRECT / INDIRECT <br />DIG-S22-217-WPR- <br />8 <br />17WINDIRECT <br />(2()300 <br />2'x2' RECESSED <br />F2E <br />WILLIAMS <br />AWM/EM2-EBHW2- <br />120 <br />K) <br />120 <br />RECESSED <br />W/2R AMECTP EMERGENCY <br />BATTERY PACK <br />8" DECORATIVE GLASS <br />F3E <br />OMEGA <br />OM832PLTFLD-CSFF- <br />(1) 32W TTT <br />120 <br />RECESSED <br />TRIM DOWNLIGHT <br />EM-120/277 <br />(2700K) <br />W/1-LAMP EMERGENCY <br />BATTERY PACK <br />F4 <br />OMEGA <br />OM61H32PLTLWWCS- <br />(1) 32W TTT <br />120 <br />RECESSED <br />6" LENSED WALL WASH <br />DLi-120/277 <br />(2700K) <br />W/DIMMING <br />F5 <br />OMEGA <br />OM632PLT-CSSPL-FL- <br />120/277 <br />(1 32W TT <br />2700K) <br />120 <br />RECESSED <br />6" LENSED VERTICAL DOWNLIGHT <br />F6 <br />SPEX <br />S6SRDiH32PLTU- <br />T6SRDiHSHWRDOP <br />(1) 32W TTT <br />(2700K) <br />120 <br />RECESSED <br />6" SHOWER LIGHT <br />F7 <br />DESIGN <br />GALLERIES <br />ALPINE 8153-02 <br />(3) 100W MAX <br />120 <br />WALL <br />MOUNTED <br />POLISHED BRASS 3-LAMP WALL <br />SCONCE, OWNER SHALL SELECT <br />LAMP TYPE <br />F8 <br />DESIGN <br />745OF <br />(1) 32W TTT <br />120 <br />WALL <br />POLISHED BRASS DECORATIVE <br />GALLERIES <br />(ADA BRACKET) <br />(2700K) <br />MOUNTED <br />WALL SCONCE <br />F9 <br />HAMPTON BAY <br />58020 <br />N/A <br />120 <br />CEILING <br />MOUNTED <br />52" NATURAL IRON <br />CEILING FAN, NOTE 1 <br />MCPHILBEN <br />VU6 <br />(2) 5.4W <br />120 <br />WALL <br />EMERGENCY WALL PACK, LAMPS <br />TUNGSTEN <br />MOUNTED <br />INCLUDED WITH FIXTURE <br />® <br />MCPHILBEN <br />ER45VXLlRC <br />LED <br />120 <br />CEILING <br />45VX LINE ARCHITECTURAL <br />EDGE -LIT EXIT SIGN, NOTE 2 <br />NOTES: <br />1. DO NOT INSTALL STANDARD LIGHT KIT PROVIDED WITH CEILING FAN. <br />2. PROVIDE DIRECTIONAL ARROWS AS INDICATED THIS SHEET. <br />OCCUPANCY SENSOR LEGEND <br />TYPE <br />MANUFACTURER <br />CATALOG No. <br />MOUNTING <br />REMARKS <br />SENSOR SWITCH <br />CM PDT 9 <br />© <br />STANDARD RANGE 3600 OCCUPANCY <br />GREEN GATE <br />OMC-DT 2000-R <br />CEILING MOUNTED <br />SENSOR, CEILING MOUNTED, LOW <br />VOLTAGE, DUAL TECHNOLOGY <br />DOUGLAS <br />CM PDT 9 <br />CONTROLS <br />SENSOR SWITCH <br />WSD-PDT <br />® <br />WALL MOUNTED AT <br />STANDARD RANGE 3600 OCCUPANCY <br />SENSOR, WALL MOUNTED, LOW <br />GREEN GATE <br />OMW-DT 0600-MV <br />T-10" AFF TO CL <br />VOLTAGE, DUAL TECHNOLOGY <br />DOUGLAS <br />CONTROLS <br />WSD-PDT <br />OCCUPANCY SENSOR NOTES: <br />1. CONTRACTOR SHALL PROVIDE POWER RELAYS AND SHALL COORDINATE QUANTITIES AND LOCATION AS SPECIFIED BY <br />MANUFACTURER. <br />2. CONTRACTOR MAY BE REQUIRED TO PROVIDE ADDITIONAL SENSORS AND TYPES OF SENSORS TO PROVIDE COMPLETE <br />COVERAGE DEPENDING ON FINAL PARTITION, FURNITURE AND EQUIPMENT HEIGHT/PLACEMENT. <br />DRAWING INDEX <br />NUMBER <br />TITLE <br />E0.1 <br />SYMBOL LEGEND, NOTES & DRAWING INDEX <br />E1.1 <br />LIGHTING PLAN - NEW CONSTRUCTION <br />E2.1 <br />POWER PLAN - NEW CONSTRUCTION <br />E3.1 <br />SYSTEMS PLAN - NEW CONSTRUCTION <br />Project No. 10006.01 <br />E0,81 <br />$DATE$ $TIME$ $FILER$ <br />02010 BHIPSArchitects, Inc. <br />