Laserfiche WebLink
Heartland <br />PROJECT NOTES <br />Dental - <br />Ze P h y rhills, <br />'renant Improvements <br />ALL WORK SHALL COMPLY WITH <br />NiFFA CODES AND STANDARDS <br />REVIEW DATE H <br />CITY OF ZEPHYRHILLS <br />FIRE AND LIFE SAFETY EXAMINER <br />GENERAL NOTE5: <br />I. DO NOT SCALE DRAWIN65. USE WRITTEN DIMENSIONS ONLY. SUBMIT ANY DISCREPANCIES <br />TO THE ARCHITECT FOR CLARIFICATION <br />2. ALL WORK SHALL BE IN COMPLIANCE WITH THE STANDARD BUILDIN6 REG06NIZED <br />INDU5TRY STANDARDS, GRAFT5MAN514IP 5TANDARD5 IN THE AREA, ALL MANUFAGTURER <br />RECOMMENDATIONS, AND ALL OTHER APPLIGABLE CODES <br />3. PROVIDE AGGE551BILITY FOR THE PHY51GALLY HANDICAPPED GONFORMIN6 TO THE <br />AMERICANS WITH D15ABILITIE5 ACT OF 2010. TO THE BEST OF OUR KNOWLEDGE, TH15 <br />BUILDIN6 HAS BEEN DE516NED IN ACCORDANCE WITH THE 2012 IBC, AND THE RULES AND <br />REC-ULATION5 OF NEN CONSTRUCTION PER ADA <br />4. THE GONTRAGTOR(5) SHALL BE RE5PON51BLE FOR BUILDIN6 THIS PROJEGT IN <br />ACCORDANCE WITH THE DRAKIN65 AND 5PEGIFIGATION5 UNLE55 A WRITTEN NOTIFICATION <br />FROM THE OWNER OR ARCHITECT TO THE CONTRARY 15 RECEIVED <br />5. THE ARCHITECT DOES NOT GUARANTEE THE PERFORMANCE OF THE PROJEGT IN ANY <br />RESPECT OTHER THAN THAT OUR ARCHITECTURAL WORK AND JUDGEMENT RENDERED <br />MEETS THE STANDARDS OF CARE OF OUR PROFE55ION <br />6. THE LOCATION OF THE EXI5TIN6 UTILITIES AND STRUCTURES 5HOWN HEREON ARE <br />APPROXIMATE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE <br />EXISTENCE AND ACTUAL LOCATION OF SUCH, WHETHER 5HOKN HEREON OR NOT, PRIOR TO <br />ANY EXCAVATION. ANY DAMA6E5 SHALL BE REPAIRED AT THE EXPENSE OF THE <br />CONTRACTOR <br />1. THE CONTRACTOR SHALL PROVIDE ADEQUATE BRAGIN6 AND 5HORIN6 FOR ALL WORK <br />DURIN6 THE CONSTRUCTION PERIOD <br />8. PROVIDE ILLUMINATED EXIT 516N5 WITH BATTERY BAGKUP DE516NATIN6 EXITS AND WAYS <br />OF TRAVEL THERETO <br />q. FIRE BARRIER SHALL BE CONTINUOUS FROM OUT5IDE WALL TO OUTSIDE WALL, FROM A <br />FIRE BARRIER TO ANOTHER FIRE BARRIER, OR A COMBINATION THEREOF, INGLUDIN6 <br />CONTINUITY THROUGH ALL CONGEALED SPACES SUCH A5 TH05E FOUND ABOVE A GEILIN6, <br />INGLUDIN6 INTER5TITAL 5PAGE5 <br />10. PA55A(5E5 OF PIPES, CONDUITS, BUS DUCTS, GABLES, WIRE5, AIRDUGT5, PNEUMATIC DUGT5, <br />AND 51MILAR BUILDIN6 SERVICE EQUIPMENT THROUGH FIRE BARRIERS SHALL BE <br />PROTECTED AS FOLLOW <br />10.1. THE SPACE BETWEEN PENETRATIN6 ITEM AND FIRE BARRIER SHALL BE FILLED WITH <br />A MATERIAL GAPA13LE OF MAINTAININ6 THE FIRE RE515TANGE RATING OF THE FIRE <br />BARRIER PRODUCT. PRODUCT USED MUST MEET TEST METHODS A5TM E814 OR UL <br />14161 FOR FIRE RATING (PER 114.3.12 4 114.4.1.1.2 IBG 2012) <br />10.2. FIRE BARRIERS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH 2" <br />5TENGILIN6 (AT 12" O.G) ABOVE ANY DECORATIVE GEILIN6 AND CONGEALED <br />5PAGE5 KITH THE FOLLOWING: <br />10.2.1. FIRE/SMOKE BARRIER <br />10.2.2. PROTECT ALL OPENINGS <br />II. PROVIDE AT LEAST I GLA55 AEG 5 POUND FIRE EXTINOU15HER TO BE MOUNTED WHERE <br />READILY VISIBLE AND AGGE551BLE. ADDITIONAL UNITS MAY BE REQUIRED TO MEET A 15 <br />FT. TRAVEL DISTANCE LIMITATION. INSTALL IN ACCORDANCE WITH NFPA 10 OR PER <br />LOCAL AUTHORITY. <br />12. WHEN A BEAM OR COLUMN BEGOME5 PART OF A FIRE RATED WALL OR GEILIN6 IT MUST <br />BE PROTECTED AND BE FIRE RATED A5 15 THE WALL OR GEILIN6. <br />13. SHELL MEGHANIGAL ROOM SHALL BE SEPARATED FROM THE REST OF THE BUILDING BY <br />ONE HOUR RATED FIRE-RE515TIVE CONSTRUCTION WITH ALL OPENINGS PROTECTED BY 45 <br />MINUTE LABELED FIRE DOOR ASSEMBLY. ALL RATED WALLS, WINDOWS, AND DOORS <br />SHALL BE CLEARLY IDENTIFIED ON ARCHITECTURAL DRAWIN65. <br />14. THE FLOOR ON BOTH SIDES OF A DOOR SHALL BE LEVEL AND SHALL HAVE THE SAME <br />ELEVATION ON BOTH 51DE5 OF THE DOOR, FOR A D15TANGE ON EACH 51DE EQUAL TO THE <br />WIDTH OF THE WIDE5T SINGLE DOOR. <br />15. DOORS IN EXITS SHALL NOT BE SUBJECT TO THE USE OF A KEY FOR OPERATION FROM <br />THE INSIDE OF THE BUILDIN6. <br />I6. EVERY INTERIOR AND EXTERIOR DOOR IN THE BUILDIN6 SHALL BE PROVIDED WITH <br />HANDICAP HARDWARE (LEVERS, PANIC HARDWARE, OR U-SHAPE DE516NED DEVICES, ETC) <br />11. PROVIDE J-MOLDS AND CORNER BEADS AT THE ED6E5 OF ALL EIF5 5Y5TEM5 AND <br />6YP5UM BOARD. <br />734 Gall Boulevard <br />ephyrhills, Florida 33541 <br />18. PROVIDE CONTINUOUS BLOGKIN6 IN ALL STUD KALL5 THAT ARE TO RECEIVE 6RAB BARS, <br />TOILET PARTITIONS, ETC. <br />A ALL METAL STUD GAUGE DE516N SHALL BE AS REQUIRED BY PERFORMANCE AND AS <br />INDICATED IN THE DRAWIN65. <br />20. PROVIDE SEPARATION BETWEEN ALL D1551MILAR METALS INGLUDIN6 56REW5, NAILS AND <br />OTHER FASTENING DEVICES <br />21. WHERE MATERIAL FASTENERS ARE NOT INDICATED, PROVIDE A5 SPECIFIED BY THE <br />MATERIAL MANUFACTURER'S RECOMMENDATIONS AND PROGEDURE5 <br />22. USE ONLY 'LEAD-FREE' PIPE AND SOLDER FOR DOMESTIC WATTE SYSTEM (SAFE DRINKING <br />WATER ACT OF Ig86 AND 5.5.P.G. SECTION 1210.1.4) <br />23. GENERAL CONTRACTOR SHALL TREAT THE 501L BENEATH THE SUITE 5PAGE5 WITH TERMITE <br />POISON PER MANUFACTURER'S RECOMMENDATIONS <br />24. ALL KALL5 TO BE ANCHORED BY POWER ACTUATED FASTENERS <br />25. ALL WOOD THAT 15 IN DIRECT CONTACT WITH CEMENT, MA50NRY OR EARTH SHALL BE <br />PRE55URE TREATE <br />26. BUILDING 516NAGE 15 TO BE PERMITTED UNDER SEPARATE COVER <br />21. 6YP51)M BOARD WALL5 AND GEILIN65 SHALL BE INSTALLED PER THE GYPSUM <br />GON5TRUGTION HANDBOOK, 6TH EDITION. LEVELS OF FIN15H PER THE FOLLOWING: <br />LEVEL 1: IN CONGEALED 5PAGE5, PLENUMS ABOVE GEILIN65, SERVICE <br />GORRIDOR5 AND 5PAGE5 NOT OPEN TO PUBLIC VIEW <br />LEVEL 2: IN WAREHOU5E AND STORAGE SPACES <br />LEVEL 3: IN AREAS TO RECEIVE HEAVY TEXTURED WALL FIN15HE5, COMMERCIAL <br />GRADE (HEAVY-DUTY) KALL GOVERIN6 <br />LEVEL 4: IN AREAS TO RECEIVE FLAT PAINTS, LI6HT TEXTURES, RESIDENTIAL <br />(LIGHT -DUTY) WALL GOVERIN6 <br />LEVEL 5: IN AREAS TO RECEIVE 6LO55, SEMI-6LO55, OR ENAMEL PAINTS, <br />UNTEXTURED FINISHES AND IN CRITICAL LIGHTING AREAS <br />IN5ULATION NOTES <br />I. PROVIDE FOIL-FAGED BATT TYPE INSULATION IN EXTERIOR STUD WALLS TO MEET MINIMUM <br />R-Iq <br />2. FLAME5PREAD AND SMOKE DEVELOPMENT RATIN65 FOR BATT INSULATION VAPOR <br />RETARDER SHALL BE AS FOLLOWS <br />2.1. FLAME5PREAD:25 <br />22. 5MOKE DEVELOPMENT: 450 <br />JOINT5 AND 5EALANT NOTE-5 <br />I. PROVIDE CONTINUOUS WATERPROOFING 51LIGONE BASED SEALANT AND BACKER ROD AT <br />ALL STOREFRONT AND MASONRY JUNCTIONS AND TERMINATIONS. 5EALANT SHALL MATCH <br />STOREFRONT <br />2. PROVIDE CONTINUOUS 5EALAND AND BACKER ROD AT ALL JUNCTIONS BETWEEN <br />DISSIMILAR MATERIALS, I.E. BRICK TO EIF5 ETC. DOW/GORNIN6 #1qO <br />3. THE METAL E06E 5EGUREMENT, EXCEPT GUTTER, SHALL BE INSTALLED AS TESTED IN <br />ACCORDANCE WITH M05T CURRENT VERSION OF THE AN51/5PRI EX -I, AMERICAN NATIONAL <br />STANDARD FOR E06E SYSTEMS USED WITH LOW-5LOPE ROOFIN6 5Y5TEM5 <br />4. PROVIDE 5TANDIN6 SEAM JOINTS AT ALL GOPING 5LIGE5 FOR THERMAL EXPANSION. ALL <br />5EAM5 SHALL BE SEALED WITH DOW/GORNIN6 #7q5 TYP. <br />5. PROVIDE GL05URE END GAPS AND qO DEGREE TRANSITIONS AT ALL EXPAN510N JOINTS <br />AND END WALL GAPS AT 6RAVEL5TOP5, TYP. <br />6. ALL METAL VENTS AND FLUES SHALL BE FLASHED WITH 'PORTALS PLUS' FLA5HIN6 BOOT, <br />TYP. SEAL ALL METAL TO METAL CONNECTIONS WITH DOW/GORNIN6 #1q5 (NOTE: NO CLEAR <br />51LIGONE SEALANT SHALL BE ALLONED) <br />1. ANCHOR ALL PRE55URE TREATED WOOD BLOGKING AT TOP OF MASONRY WALL5 UNDER <br />GOPIN6 WITH 3/8" DIA. HOT DIPPED 6ALVANIZED ANGHOR5 AT 36" O.G. <br />8. ALL EXTERIOR JOINTS IN THE BUILDIN6 ENVELOPE THAT ARE SOURCES OF AIR LEAKS <br />SHALL BE CAULKED, &A5KETED, WEATHER STRIPPED, OR OTHERWI5E SEALED IN <br />AGGORDANGE WITH SPECIFICATIONS <br />q. PROVIDE CONTROL JOINTS IN 6YP5UM BOARD PER A5TM G-840 AND 6A-216-10 <br />DESIGN SUMMARY <br />SYNOPSIS: <br />THE SCOPE OF WORK CONSISTS OF A SINGLE TENANT BUILD -OUT <br />OF APPROXIMATELY 4,125 SQUARE FEET IN AN EXISTING BANK <br />SHELL BUILDING, LOCATED IN ZEPHYRHILLS, FL. THE EXISTING <br />STRUCTURE INCLUDES, BUT IS NOT LIMITED TO, A 4" THICK <br />CONCRETE SLAB, POURED CONCRETE � GMU HALL GONSTRUGTION <br />WITH BRICK EXTERIOR VENEER, STEEL JOISTS AND BUILT-UP ROOF <br />SYSTEM ON METAL ROOF DECKING. INTERIOR CONSTRUCTION WILL <br />COMPRISE OF METAL STUD FRAMING. EXTERIOR GON5TRUGTION <br />HILL CONSIST OF THE REMOVAL OF THE DRIVE -THROUGH CANOPY. <br />ALL NEW CONSTRUCTION WILL MATCH THAT ALLOWED IN TYPE V-B <br />CONSTRUCTION. <br />OGGUPANGY GLASSIEIGATION: <br />FBG CLASSIFICATION - BUSINESS (DENTAL OFFICE) <br />LIFE SAFETY CODE GLASSIFICATION - BU51NE55 (DENTAL OFFICE) <br />BU I LD I NO GON5TRUGTION:_ <br />GON5TRUGTION TYPE: TYPE V-B <br />SPRINKLERED: NO <br />FIRE ALARM: NO <br />TENANT AREA: <br />4,3c10 SG2. FT. (GROSS SQUARE FOOTAGE) <br />4,125 50. FT. (NET SQUARE FOOTAGE) <br />OGGUPANT LOAD 4 EGRESS WIDTHS: <br />4,125 50. FT. / 100 5F/PER5ON = 41.25 PERSONS <br />42 PERSONS 0.2 I N/PER50N = 8.4 INCHES REGU I RED, 68 I NGHES <br />PROVIDED <br />PLUM$ I NG GALGULAT IONS <br />WATER CLOSETS <br />LAVATORIES <br />DRINKING <br />OGGUPANGY: <br />BATHTUBS/ <br />FOUNTAINS <br />OTHER <br />MALE <br />FEMALE <br />MALE <br />FEMALE <br />I <br />B (BUSINESS) <br />5HOWER5 <br />I PER 25 FOR THE FIRST 50 AND I PER 50 <br />1 PER 40 FOR THE FIRST 80 AND I PER BO <br />I PER 100 <br />FOR THE REMAINDER EXGEEDIN6 50 <br />FOR THE REMAINDER EX8 GEEDIN6 0 <br /># REQUIRED <br />I <br />I <br />I <br />I <br />----- <br />I <br />I SERVICE SINK <br /># PROVIDED <br />I <br />I <br />I <br />I <br />----- <br />I <br />I SERVICE SINK; I UNISEX RESTROOM <br />GONTAGTS <br />TENANT <br />HEARTLAND DENTAL <br />1200 NETWORK CENTRE DRIVE <br />EFF I N&HAM, IL 62401 <br />CONTACT: ZAGH TYLKA <br />PHONE: (217) 540-8216 <br />OWNER <br />WM6 DEVELOPMENT <br />1200 NETWORK CENTRE DRIVE <br />EFFIN&HAM, IL 62401 <br />CONTACT: ZAGH TYLKA <br />PHONE: (217) 540-8216 <br />ARGHITEGT <br />HILL FOLEY R0551 4 A550GIATE5, LLG <br />3680 PLEASANT HILL ROAD <br />SUITE 200 <br />DULUTH, 6A 300% <br />CONTACT: BRAD MGGULLOU6H, R.A. <br />PHONE: (770) 622-g858 <br />MEP EN61 NEERI NG <br />SHEPHERD, HARVEY 6 A550GIATE5, INC. <br />4855 RIVER GREEN PARKWAY <br />SUITE 400 <br />DULUTH, 6A 300g6 <br />CONTACT: BRAD SHEPHERD, P.E. <br />PHONE: (770) 4q5-4007 <br />DES I (5N GODES <br />• 2017 FLORIDA BUILDING CODE ((qTH EDITION) <br />• 2017 FLORIDA MEGHANIGAL GODE 66TH EDITION) <br />• 2017 FLORIDA PLUMBING CODE (6TH EDITION) `- <br />DRAWING INDEX <br />SHEET <br />DRANIN6 NAME <br />GO 155UE <br />REV #1 <br />REV #2 <br />REV #3 <br />ARCHITECTURAL <br />02-13-Iq <br />A001 <br />COVER SHEET <br />A002 <br />SPECIFICATIONS <br />A003 <br />5PEGIFIGATION5 <br />Q <br />A004 <br />5PEGIFIGATION5 <br />A005 <br />5PEGIFIGATION5 <br />A006 <br />U.L. DETAILS <br />Q <br />A007 <br />GENERAL NOTES, DOOR 8 WINDOW SGHEOULE5 <br />A008 <br />LIFE SAFETY PLAN, DETAILS $ NOTES <br />0101 <br />DEMOLITION FLOOR PLAN <br />Q <br />D20I <br />DEMOLITION EXTERIOR ELEVATIONS <br />A100 <br />SITE PLAN <br />AIOI <br />FLOOR PLAN <br />Q <br />AI02 <br />EQUIPMENT PLAN <br />AI03 <br />EQUIPMENT DETAILS <br />Q <br />A201 <br />EXTERIOR ELEVATIONS <br />A501 <br />RE5TROOM PLAN, DETAILS 4 ELEVATIONS <br />A502 <br />INTERIOR ELEVATIONS <br />A503 <br />INTERIOR ELEVATIONS <br />A504 <br />INTERIOR ELEVATIONS <br />A505 <br />INTERIOR ELEVATIONS <br />A601 <br />REFLECTED CEILING PLAN <br />A602 <br />REFLECTED GEILIN6 PLAN DETAILS <br />" <br />A801 <br />ROOM FINISH PLAN, DETAILS 4 SGHEDULES <br />Q <br />A802 <br />ROOM FINISH DETAILS <br />Q <br />MECHANICAL <br />02-15-Iq <br />MOOT <br />MEGHANIGAL NOTES $ LEGENDS <br />M002 <br />MEGHANIGAL DETAILS <br />Q <br />M003 <br />MEGHANIGAL SCHEDULES <br />MIOI I <br />MEGHANIGAL FLOOR PLAN <br />ELECTRICAL <br />02-13-Iq <br />E001 <br />ELECTRICAL NOTES 8 5PE6IFIGATION5 <br />Q <br />E101 <br />ELECTRICAL FLOOR PLAN - LIGHTING <br />Q <br />E102 <br />ELECTRICAL FLOOR PLAN - POWER 6 SYSTEMS <br />Q <br />E500 <br />ELECTRICAL SCHEDULES 8 RISERS <br />E511 <br />ELECTRICAL DETAILS <br />Q <br />PLUMBING <br />02-13-14 <br />POOI <br />PLUMBING NOTES 4 SPECIFICATIONS <br />P002 <br />PLUMBING SCHEDULES <br />P005 <br />PLUMBING DETAILS <br />P004 <br />PLUMBING DETAILS <br />P005 <br />PLUMBING RISER DIAGRAM <br />Q <br />PIOI <br />PLUMBING FLOOR PLAN - WASTE $ VENT <br />Q <br />P102 <br />PLUMBING FLOOR PLAN - WATER <br />Q <br />P103 <br />PLUMBING FLOOR PLAN - MEDIGAL GAS <br />Q <br />• 6TH EDITION FLORIDA FIRE PREVENTION CODE <br />(BASED ON NFPA I UNIFORM FIRE CODE 2015 EDITION 4 NFPA 101 LIFE <br />SAFETY CODE 2015 EDITION) <br />• 2014 NATIONAL ELECTRICAL CODE <br />• 2017 FLORIDA BUILDING CODE ACCESSIBILITY (6TH EDITION) <br />VIGINITY PLAN <br />KEY PLAN <br />_o <br />3 <br />S 1 T,r�� a 3� <br />16 <br />N <br />p <br />.:. .... ...... <br />a ,w <br />TRH , NORTH <br />TRUE NORTH <br />£. <br />ARCHITECTURE <br />ENGINEERING <br />3680 Pleasant Hill Road <br />Suite 200 <br />Duluth, Georgia 30096 <br />p 770.622.9858 <br />f 770.622.9535 <br />www.hillfoleyrossi.com <br />© Copyright (as dated below). <br />This drawing and all reproductions thereof are the <br />property of Hill Foley Rossi & Associates, LLC.(HFR). <br />It is intended for the sole use of the project named <br />hereon. Reproduction without the written consent of <br />HFR is unlawful. All copies are to be returned to HPR <br />upon project completion. <br />sealed: 02-13-2019 <br />N <br />�L <br />0 <br />N <br />L <br />C: ' <br />C <br />� <br />o <br />ICUU <br />� <br />� <br />N <br />J <br />-L_ <br />O <br />0 <br />0 <br />- <br />LL <br />j2 <br />Z <br />CU <br />s <br />U) <br />� <br />N <br />O <br />O <br />O <br />_ <br />W <br />LL <br />Q_ <br />C/) <br />N <br />-f--, <br />� <br />E <br />r <br />LO <br />M <br />C: <br />O <br />L <br />0 <br />> <br />0 <br />O <br />_0O <br />M <br />Co <br />Ion <br />N <br />4-1CU <br />.L <br />ICU <br />(1) <br />C <br />a <br />O- <br />= <br />FZ <br />ti <br />N <br />02/13/191 For <br />Construction <br />mk I date issue <br />Cover <br />Sheet <br />A0011111 <br />HFR 18.945 <br />