My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7350 Dairy Rd (5)
Zephyrhills
>
Building Department
>
Building Plans
>
7350 Dairy Rd (5)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:14:12 AM
Creation date
2/25/2025 9:51:30 AM
Metadata
Fields
Template:
Building Plans
Street #
7350
Location
Dairy Rd
Contractor
Ryan Companies
Building Plans - Permit #
18254
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br />CIRCUIT LEGEND <br />TO AID IN DETERMINING CIRCUIT TYPE AND <br />CONNECTIONS, THE FOLLOWING CIRCUITING <br />LEGEND HAS BEEN ADDED TO THIS DRAWINGS. <br />LIGHTING POWER <br />LIGHTING SWITCH LEG <br />RECEPTACLE POWER <br />CEILING <br />1. REFER TO RISER DIAGRAM, ELECTRICAL DETAILS AND PANEL <br />SCHEDULES FOR MORE INFORMATION. <br />2. COORDINATE ALL DEVICE/LIGHT LOCATIONS WITH <br />ARCHITECTURAL DRAWINGS AND DIAGRAMS PRIOR TO ROUGH <br />IN. <br />3. PROVIDE NEW NAME ENGRAVED COVER PLATES INDICATING <br />SUPPLY PANEL AND CIRCUIT NUMBER(S) FOR ALL ELECTRICAL <br />DEVICES IN THIS PROJECT. ENGRAVING SHALL BE RED FOR <br />CRITICAL AND BLACK FOR NORMAL CIRCUITS. <br />4. PROVIDE NEW TYPED PANEL SCHEDULES FOR ALL PANELS <br />USED IN THIS PROJECT. <br />5. PROVIDE PHENOLIC NAMEPLATES ON ALL PANELBOARDS, <br />SWITCHBOARDS, DISCONNECTS, TRANSFORMERS, ETC, <br />INDICATING DESIGNATION, CIRCUIT NUMBER(S), VOLTAGE AND <br />WHERE UNIT IS FED FROM. SECURE NAMEPLATES WITH AT <br />LEAST TWO SCREWS OR RIVETS. CEMENTING AND ADHESIVE <br />INSTALLATION WILL NOT BE ACCEPTABLE. NAMEPLATES SHALL <br />BE COLORED AS PER SPECIFICATIONS. <br />6. WALL MOUNTED SWITCHES FOR LIGHTING IN RESIDENT AREAS <br />SHALL BE "QUIET" OPERATING TYPE. <br />7. ALL JUNCTION BOXES (NEW AND EXISTING) IN CEILING SPACE <br />MUST BE LOCATED OUTSIDE OF HARD CIELINGS AND ABOVE AN <br />ACCESSIBLE CEILING OR PROVIDE ACCESS PANELS WHERE J- <br />BOXES ARE WITHIN ARMS REACH. THE REMOVAL OF A LIGHT <br />FIXTURE FOR ACCESS WILL NOT BE ACCEPTABLE INSIDE LAB. <br />LOCATE NEW J-BOXES ABOVE ACCESSIBLE CEILINGS OR <br />CORRIDORS. RELOCATE ALL EXISTING J-BOXES ABOVE AREA <br />OF WORK. PROVIDE ALL NECESSARY ACCESS PANELS. <br />8. REFER TO NURSECALL DRAWINGS FOR NEW RAULAND-BORG RESPONDER 5 <br />REQUIREMENTS. <br />KEY NOTES: <br />NIGHT STAND SHALL BE PROVIDED WITH A FIXED LAMP FOR <br />USE AS GENERAL LIGHTING. LAMP SHALL HAVE SWITCH <br />CONTROL CONVENIENT FOR USE AT THE LUMINARY. <br />PROVIDED BY OWNER. <br />❑ - NOT USED - <br />❑3 COORDINATE EXACT MOUNTING HEIGHT OF RECEPTACLE, TV <br />OUTLETS, CABLE OUTLET WITH ARCHITECTURAL ELEVATIONS <br />PRIOR TO ROUGH -IN. <br />REFER TO HEADWALL ELEVATION DETAIL ON THIS SHEET. <br />5❑ BED SHOWN AT ANGLE IS ALTERNATE BED LOCATION. <br />TYPICAL ALL. <br />© PATIENT BED LIGHT IS 4-WAY SWITCHED WITH PULL CHAIN. <br />FIXTURE WILL BE CONNECTED/CONTROLLED VIA NEW NURSE <br />CALL SYSTEM ADDED IN A FUTURE PROJECT. <br />CRITICAL NORMAL <br />ONE (1) s— _._._ ___.____ _.___ ONE (1) <br />CIRCUIT HEADWALL CIRCUIT DATA <br />NOTES: <br />1. ALL RECEPTACLES AT THE HEADWALL SHALL BE HOSPITAL GRADE. <br />2. ALL DEVICE LOCATIONS AT THE HEADWALL SHALL BE COORDINATED WITH ARCHITECTURAL MILLWORK PRIOR TO ROUGH -IN. <br />A. PROVIDE A MINIMUM OF FOUR (4) DUPLEX RECEPTACLES FOR EACH PATIENT BED (DIVIDED ON BOTH SIDES OF THE BED). <br />B. TWO (2) RECEPTACLES SHALL BE CONNECTED TO CRITICAL BRANCH POWER. RECEPTACLES AND COVERS SHALL BE RED. <br />C. TWO (2) RECEPTACLES SHALL BE CONNECTED TO NORMAL BRANCH POWER. <br />D. THERE SHALL NOT BE MORE THAN SIX (6) DUPLEX RECEPTACLES PER CIRCUIT. <br />E. CRITICAL BRANCH CIRCUITS SHALL BE FROM THE SAME PANEL BOARD. <br />F. NORMAL BRANCH CIRCUITS SHALL BE FROM THE SAME PANEL BOARD. <br />G. ALL RECEPTACLE COVERS SHALL HAVE ENGRAVED COVER PLATES PER SPECS TO INDICATE THE PANEL BOARD AND CIRCUIT <br />NUMBERS SERVING THAT DEVICE, <br />H. PANEL BOARD WITH BRANCH CIRCUIT OVER -CURRENT DEVICES SHALL BE READILY ACCESSIBLE TO NURSING STAFF AND <br />AUTHORIZED PERSONNEL. <br />HEADWALL ELEVATION DETAIL <br />SCALE: NONE <br />California I Florida I Nevada <br />Peninsula Engineering, INC. <br />MEP&FP <br />PENINSULA <br />ENGINEERING <br />INC. <br />2016 ALDEN ROAD <br />ORLANDO, FL 32803 <br />CA 3089 <br />VOICE- (407)246.1688 <br />FAX: (407) 246.1664 <br />httpolwww.peifa.com <br />Email to: pei®peiflacom <br />JOB 0:15384 <br />Copyright - All ideas, designs, <br />methods and plans indicated or <br />represented by this drawing are <br />owned by and the property of <br />Peninsula Engineering, Inc. and <br />were created, evolved and <br />developed for use on and in <br />connection with the specified <br />project. None of the ideas, <br />designs, arrangements, methods <br />or plans shall be used by or <br />disclosed to any person, flan or <br />corporation for any purpose <br />whatsoever without the written <br />permission of Peninsula <br />Engineering, Inc. <br />(90pyright <br />2015 <br />ARCHISPEC, INC <br />ARCHITECTURAL SPECIFICATIONS <br />653 Mallory Hill Drive Lady Lake, FL 32162 <br />P: 352.430.0987 <br />REVISIONS: <br />AHCAm._.... �..__.._� .e........_....._ <br />-�/2__._.___ -3/16 REVISION #1 ._._.. _ <br />3 03/10,117 REVISION #2 <br />PROJECT TITLE: <br />ZEPHYRHILLS HEALTH &REHAB <br />CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS., FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />OVERALL UNIT PLANS LAYOUT - <br />RENOVATION - ELECTRICAL <br />OVERALL UNIT PLANS LAYOUT - RENOVATION as ELECTRICAL <br />1 /4" =1'-0" <br />('•\I 71=Dl-1VP"11 I C WPAI T" R. DPWAR r1r=KIT9:R i-nmccn nh <br />7T- II -R-__ _FT _ _-__ _ - <br />PROJECT NORTH <br />TRUE NORTH <br />E502 © 20jStud,o+ <br />
The URL can be used to link to this page
Your browser does not support the video tag.