Laserfiche WebLink
I 1 -- - - I I -- - - I --- 1 — _ LI_ L 11 ' I l 'll r 'I - I I I - I _ P I ' 11 rf 1 111 II wifil _111prp,'ll 11 11 II 1 L'' I 1 I I 1 1 <br />8 <br />7 <br />6 <br />5 <br />F <br />E <br />BLOX RAINSCREEN <br />BACKUP PANEL <br />FASTEN 1" ALUM Z-PROFILE <br />TO GALV GIRT PER <br />RAINSCREEN MANUFACTURE <br />INSTALL REQUIREMENTS <br />FASTEN PRE -MANUFACTURED - <br />`F <br />FIBER CEMENT PANEL TO <br />- <br />ALUM Z-GIRT W/ ALUM RIVET <br />PER RAINSCREEN <br />l <br />MANUFACTURE'S INSTALL <br />REQUIREMENTS <br />i <br />BR-01, REF FSO.11 <br />D <br />INSTALL BACKER ROD & -- - <br />SEALANT BETWEEN <br />\ <br />PLYWOOD AND <br />/ <br />CURTAIN WALL HEADER <br />/ <br />MECHANICALLY FASTEN <br />BR-02 WITHIN JAMB <br />/ <br />CURTAIN WALL SYSTEM ' <br />STOREFRONT HEAD <br />@ SF1 <br />✓V <br />311 = 1'-011 <br />FIELD INSTALL BREAK -----___ <br />METAL TRIM, BR-03 <br />FIELD INSTALL 2" <br />RIGID INSULATION - <br />FIELD INSTALL PEEL & STICK <br />AIR & WATER BARRIER. LAP <br />C OVER GALV. FLASHING <br />0 <br />GALV. FLASHING <br />INSTALL CONTINOUS <br />BACKER ROD & SEALANT <br />BASE @ ENTRY JAMB <br />�J 311 = 1'-0" <br />FASTEN PRE -MANUFACTURED <br />FIBER CEMENT PANEL TO ALUM \ <br />0 <br />3 2 <br />BREAK METAL HE <br />RAIN SCREEN SY <br />BEYOND <br />3/4" SHIM AND SE <br />PAINTED STEEL <br />CURTAIN WALL SYSTEM <br />NSTALL BACKER ROD & SEALANT <br />BETWEEN STL ANGLE AND \ <br />CURTAIN WALL SILL <br />CEILING AND AXIOM <br />TRIM. REF D2/FF1.14 <br />BLOX UBER MODULE <br />SIDEWALK. REF CIVIL <br />° <br />VAPOR BARRIER & dTERM BAR aad - <br />d° <br />ed <br />a <br />l- i \II1 - ' <br />Iy1 <br />1 <br />Oo0 G GcC U OcCo <br />4— <br />I �otJ. J <br />4" RIGID INSULATION <br />' <br />�L cCeGc loGooc.� c .Oc OcooO Oc.JcO cOc"aQo <br />- IO C�oOc(o�?�O�JoO.�OaOcvcCc•Jc.OcU.:UcUcOC.o <br />_ �- __-_. i -- `��o-o•�oco�Gco,cococ,o. �coc� o'-o�'Goo`-'G <br />_ — —=oOoCcUoOoQo 00 OoOa > O .�cG.OcGcucOo I I <br />- <br />---� -- II-1 <br />Oc oG:.C..Oo �.:UoGc.Uc..cOoQcc�o�,70 - - I 4X8X16 GA GALV. SHEET <br />METAL ANGLE CONT. <br />V� PUNCHED 24" O.C. W/12" I'1 <br />LONG LANDSCAPE SPIKES <br />_\II - <br />I �I <br />\ <br />i <br />i — I T.M—IIII= Ii <br />1 II —1\II i \\S, li II j I illy II-1 II ,1 <br />L'- <br />-i _ 111 r i <br />I <br />�l II -III I -I II-- 1i--I ,IIII.' <br />'I =11 _ I <br />_ � I <br />— <br />I I11 II _III <br />T� -- —.7_ <br />GRID _ <br />I _ <br />-.I f <br />I <br />B F STOREFRONT I TYPICAL BELOW GRADE <br />BASE O S @ <br />I- CONDITION <br />d ° <7177 <br />d � <br />d ` <br />I <br />d a <br />d <br />e d° <br />° <br />d <br />-1- I1 <br />a ° d <br />a 1 <br />i <br />I I'll <br />Z-GIRT W/ ALUM RIVET PER <br />\ <br />RAINSCREEN MANUFACTURE'S <br />\ <br />INSTALL REQUIREMENTS <br />\ <br />FASTEN 1" ALUM Z-PROFILE TO \ <br />GALV GIRT PER RAINSCREEN <br />�' <br />MANUFACTURE INSTALL <br />REQUIREMENTS <br />\ <br />INSTALL BACKER ROD & SEALANT <br />BETWEEN STL ANGLE AND WALL <br />PANEL <br />\ <br />'N TA L BA ROD & SEALANT <br />O BACKER <br />S L C <br />BEHIND HOLES IN WEEP TRACK <br />\ <br />SIDEWALK. REF CIVIL <br />SLOPE TO DRAIN <br />J° ` /a <br />d <br />Y� <br />, POR BARRIER & <br />° ° °° ° G ° <br />TERM BAR <br />d ° <br />G a <br />° <br />4" RIGID INSULATION G GOB ° a ° d A <br />BLOX EXTERIOR <br />WALL PANEL <br />BLOX UBER <br />MODULE <br />BLOX EXTERIOR WALL PANEL <br />BLOX I MODULE <br />3" = 1'-0" <br />1 <br />GRID <br />FASTEN PRE -MANUFACTURED <br />FIBER CEMENT PANEL TO ALUM —\ <br />Z-GIRT W/ ALUM RIVET PER \ <br />RAINSCREEN MANUFACTURE'S <br />INSTALL REQUIREMENTS <br />FASTEN 1" ALUM Z-PROFILE TO <br />GALV GIRT PER RAINSCREEN <br />MANUFACTURE INSTALL <br />REQUIREMENTS <br />INSTALL BACKER ROD & SEALANT BLOX EXTERIOR WALL PANEL <br />BETWEEN STL ANGLE AND WALL \ <br />PANEL \ <br />INSTALL BACKER ROD & SEALANT <br />BEHIND HOLES IN WEEP TRACK BLOX UBER MODULE <br />SIDEWALK. REF CIVIL ---` <br />° ° °� a d a a — SY =" } ! }r i •r ? f f ryb t5 E d. <br />VAPOR BARRIER & — ° a ° d <br />TERM BAR <br />G ° <br />da ° <br />d <br />4" RIGID INSULATION? <br />I I <br />Joo -� nayaoa=oaG ° < <br />0000 ?000-o e 1 <br />G J Go- �o(_, OuGcCcv 1 <br />FOUNDATION SYSTEM.��oo�\oo���ca�°°°coo a ° <br />REF STRUCTURAL DWGS .� .�cocJ OaGnCo0ovc0� d IJ.�1 <br />AND FCO SHEETS <br />vo�^oGoOoOc•�o`IoG OoGoG<.GorJ - 1 <br />0 o J�o a c0000 o-,oc0000,�co. \ I �= }Tr-\-Lr- I -il <br />OcCFJ O00000000 O Oo(�oO:0oG�0 <br />� ^o^oc000 G o G ocoaococo ° .I _r _a _ ll <br />, j CJ0000o00000oG OofJoOo,.cO - <br />7oG J O O r`cG Oo o c�J OoGoVcOo�.> OoO Jo <br />�,7 0 O" ° Oc0 >0000c0"n000Oco O('O J�.G - <br />i=�l — — � — — 1 <br />—I <br />0.0., / <br />0 O o J o o c G C`o o�ococc-ooc°o c <br />JcOc� .,G -��cCo0o0oG <br />—I I icooGcJc ::OcOcOcOa„c..eG.. �Gc �4 • '� <br />—IIII^ o o� o 0 0 0000000o co,., <br />- <br />- — O O♦ i <br />II '�cOaOcOoO t� eGvOo0o0 �oOoOc <br />I <br />I I cCic Jo I oG Oo0 Go,>.,O CoocGo�. i c.• <br />i - <br />I —i ! <br />000 ocooGo�ooc00000ao _ <br />I —I I L ,� � - •t, � ;t� <br />— .\ d ° ° I •Ida < e a a ° a ° e <br />III a ° a ° e ° a a a a <br />d 1 <br />1 <br />d d e e <br />d <br />d d < ° ° ° d ° a a ° ° ° a I° ° d a a 4 e ° a a ` d ' <br />° °O d a <br />u <br />a d a ° a ° ° a <br />d1, ° e ° d ° ° ° d <br />° 1 <br />— I— a d° a ° ° a a a <br />d 1 a d ° e ° a ° ° c° 4 <br />d e <br />- — °d a e as ° < e ° < ° <br />1= a ° d 1 <br />°° <br />_ d d <br />II, d M d a <br />— p d d d <br />III ° <br />° <br />° a <br />loll _III,_ a a a d <br />JD <br />d ® <br />° ° a ° <br />1 <br />ads <br />d <br />d - <br />li-- d <br />d° e c d ^ e I- <br />` d ° a <br />a d - <br />"- <br />I' <br />a ° ° G ° e ° < 4 ° n <br />d ° a G <br />I <br />RETAIL CLINIC <br />ADDITION TO <br />ZEPHYRHILLS <br />WALMART 706 <br />GA PROJECT No: 20CE14 <br />GIATTINA AYCOCK <br />ARCHITECTURE STUDIO INC. <br />2625 5th Avenue North, Building C <br />• rBessemer, AL 35020 <br />P: 205.933.9060 <br />GASTUDIO.COM <br />STAMP: <br />OF <br />FAO <br />i <br />��••. A 9�5P <br />�R,Ep <br />aRc <br />ISSUE SCHEDULE: <br />REVISION SCHEDULE: <br />NUM. DESCRIPTION DATE <br />NOTES & LEGEND <br />RED TEXT INDICATES A FIELD <br />INSTALLED ITEM <br />CURRENT DRAWING SET: <br />PERMIT SET <br />ISSUE DATE: 11/25/2020 <br />DRAWN BY: CHB <br />SHEET: <br />SECTION DETAILS <br />BASE OF TYP WALL PANEL a@ CURB <br />3" = 1'-0" <br />BASE OF TYP WALL PANEL @FOOTING <br />3" = 1'-0" <br />■ <br />BIM 360://WMT-Clinic-20WM00 - Prototype/6500R-Clinic-V3.la_Prototype.rvt 11/2312020 11:41:17 AM 15 of 17 <br />