Laserfiche WebLink
'61 <br />El <br />K, <br />1 <br />I <br />F <br />C <br />A <br />DIVISION 1- GENERAL REQUIREMENTS <br />DESCRIPTION <br />1. This retail clinic is an extension of the existing retail store. <br />2. Building size is approximately 6,495 GSF. <br />3. This One level building is steel -framed and designed to receive numerous modular components. This means that repetitious rooms <br />and portions thereof will be engineered, pre -manufactured, and shipped to the job site for installation. <br />4. the building is fully sprinklered and type 116 construction and is classified as business group B occupancy. <br />OWNER REQUIREMENTS <br />1. An owner Furnished Equipment spreadsheet is available. <br />2. The Owner shall arrange and pay for delivery of Owner -furnished items in accordance with the Construction Schedule, and will <br />inspect deliveries for damage. <br />3. Owner to arrange and contract services needed. Outside vendor work to be coordinated with construction schedule. <br />4. Shielding and geotechnical reports will be furnished when available. Design includes preliminary assumptions. <br />SITE <br />1. Survey, Topographic information and site lighting will be provided by licensed civil engineers and will be made available when <br />completed. <br />2. Geotechnical borings and subsurface report to be provided by Terracon and will be made available when completed. <br />3. Sanitary Sewer is available and will be shown on civil and site survey. <br />4. Storm water detention is required. Size and location shown on civil drawings at east end of site. Work will also include erosion <br />control measures during site construction. <br />5. The site will be landscaped with native planting. Landscaping design to be provided by Jaramillo Landscape & Maintenance and <br />irrigation design to be by Keman Clute.Both to be coordinated through civil engineering. <br />6. No permanent fencing is required. Perimeter security fence to be provided during construction. <br />7. Main areas to have medium -duty asphalt paving. Heavy duty asphalt and concrete paving to be provided in areas as denoted on <br />drawings. <br />8. Entire paved areas to be bordered with concrete curb and gutter. <br />BUILDING UTILITIES: <br />1. Sanitary Sewage, provide sanitary sewer connection from existing line serving retail store. <br />2. Power, new extension from store main switchboard at existing electrical room to designated connection box, work not in this <br />contract. Contractor for this project to extend conductor from designated connection box to generator connection enclosure with <br />manual transfer switch and into new clinic to main panelboard. <br />3. Domestic and Fire Water, provide taps from existing building utilities. New fire water pipe extended from existing building fire riser <br />room, new domestic water piping extended from existing building DCW piping into new clinic. <br />4. Storm Drainage, Roof storm drains extend to existing storm drainage system at site. <br />CONTRACTOR REQUIREMENTS <br />1. Temporary Facilities: Provide temporary facilities as necessary to maintain work area in a safe, orderly and clean condition. Prevent <br />dirt, dust and debris from migrating into finished areas as some components will come to the job in a completed state. Provide <br />temporary toilet facilities for job site workers. <br />2. Contractor to arrange daily inspections for compliance to cleanliness. Skilled cleaning service required for final cleaning. <br />3. Protect finished areas from ongoing work activities. <br />01-3113- PROJECT COORDINATION <br />1. All trades to review their work and associated work for their coordination. Any discrepancies or omissions in drawings or <br />specifications should be brought to the attention of the Architect for resolution. <br />2. Retain necessary permits and perform work to comply with applicable codes and ordinances. See Code Listing and Analysis on <br />"Index" sheet. <br />01-3300 - SUBMITTAL PROCEDURES <br />1. One intent of pre -manufactured construction is to minimize preparation and submission of submittals. Items outlined below are for <br />general coordination efforts. <br />2. Submittals should be prepared in advance of scheduled dates for installation to provide sufficient time for reviews, for securing <br />necessary approvals, for possible revisions and re -submittals, and for placing orders and securing delivery. <br />a. For scheduling purposes, anticipate review to take 10 working days from date submitted. <br />b. Include on submittal the section and submittal type. <br />c. All warranties are to be from the date of substantial completion. <br />3. Required Construction Submittals: <br />a. Submit product data and related information for any product intended to be used that is not listed in the specifications. This <br />includes products that are intended to be "similar to" or "equivalent to" items listed in the specifications. <br />b. Samples as noted for selection of colors by Architect as listed in the specifications. <br />c. Shop Drawings for Healthcare Medical Supports. <br />d. Shop Drawings for Interior Architectural Woodwork including product data for hardware. <br />e. Product data for Thermal Insulation. <br />f. Product data for Exterior Insulation and Finish System. <br />g. Product Data for TPO Roofing. <br />h. Shop Drawings for Shop Fabricated Sheet Metal. <br />i. Product data and schedule for doors, frames and hardware. <br />j. Shop Drawings for Overhead Coiling Doors. <br />4. Required Close-out Submittals: <br />a. Warranty for Exterior Insulation and Finish System. <br />b. Warranty for TPO Roofing. <br />c. Warranty for Joint Sealants. <br />d. Warranty for Wood Doors. <br />e. Warranty and Maintenance Instructions for Coiling Doors. <br />f. Warranty for Automatic Sliding Doors & Aluminum Framed Storefronts. <br />g. Maintenance Instructions for Flooring - all types. <br />h. Extra Stock for Acoustical Tile Ceilings, Flooring - all types <br />i. Warranty for Flooring - all types. <br />j. Test Report for Radiation Shielding Protection. <br />k. Application Report and Warranty for Termite Control. <br />I. See Mechanical, Plumbing, Electrical and Structural drawings for additional submittal requirements. <br />01-660 PRODUCT STORAGE AND HANDLING REQUIREMENTS <br />1. Store and handle products immediately on delivery in accordance with the manufacturer's printed instructions, with seal sand labels <br />intact and legible, and protect until installed in the work. Provide substantial coverings to protect installed products from damage from <br />subsequent operations. Remove when no longer needed, prior to completion of work. <br />01-7400 CLEANING AND WASTE MANAGEMENT <br />1. Keep building free from accumulations of waste materials and rubbish. Employ experienced workmen or professional cleaners for <br />final cleaning. <br />DIVISION 5 - METALS <br />05-4100 STRUCTURAL METAL STUD FRAMING (applies to site construction only - not pre -manufactured components) <br />1. Bridging, Bracing, Furring: Formed sheet steel, ASTM A36, Grade A, manufacturers standard shapes, finish same as studs. <br />2. Tracks: Deep leg type, ASTM A955, Grade A, un-punched, same gauge and finish as studs. <br />3. Anchorage and bracing, to comply with applicable building codes, including seismic requirements. <br />4. Door Openings: Install double studs within -punched webs each side of door openings. Install double studs horizontally between <br />door jambs at top of doors. <br />5. Corners: Construct using minimum three studs. <br />6. Attach bridging for studs in a manner to prevent stud rotation. Space bridging rows as recommended by manufacturer. <br />05-5000 METAL FABRICATIONS <br />1. Build exterior wall ladder as detailed on drawings of steel members conforming to ASTM A569 or ASTM A36 and steel tubing <br />confirming with ASTM A500, Grade B, cold -formed and hot -dipped galvanized. <br />DIVISION 6 - WOOD, PLASTICS AND COMPOSITES <br />06-1000 ROUGH CARPENTRY (applies to site construction only - not pre -manufactured components) <br />1. All framing, blocking and nailing strips on interior of building shall be fire retardant treated lumber, if in contact with masonry or <br />concrete use pressure treated. <br />2. Blocking for roofing, exterior signage attachments and exterior ladder to roof shall be pressure -treated. <br />3. Plywood backing for telephone and electrical equipment shall be DOC PSI, Exposure I, fire -retardant treated plywood panels, C-D <br />PLUGGED with exterior glue, 3/4 inch minimum thickness. <br />4. Provide fire retardant treatment to comply with governing ordinances and meet or exceed requirements for ASTM D5516 and <br />ASTM D5664 tests. <br />5. Pressure treated wood to be Southern Pine; SPIB, No. 2 grade. <br />6. Treatment shall not bleed through finish surfaces or corrode metal fasteners. <br />7. Use hot dip galvanized steel fasteners of size to suite application. <br />06-1643 GYPSUM WALL SHEATHING (to be included as part of pre -manufactured exterior rainscreen wall panel) <br />06-4023 INTERIOR ARCHITECTURAL WOODWORK <br />1. Fabricate cabinets per AWI- Architectural Woodwork Institute, latest edition (400BCustom, C and D) and install per AWI Section <br />1700. <br />2. Cabinet bodies: Flush overlay with W to 5/16" radius corners on doors and drawers. <br />3. Fabrication: Approved manufacturers standard specifications to insure stability and prevent racking when fully loaded. <br />4. High pressure plastic laminate for exposed cabinet surfaces: Meet NEMALD 3 standards for non -vertical grade laminate, GP-28. <br />5. Thermoset decorative overlay for concealed cabinet surfaces: Particle board complying with ANSI A208.1, Grade M-2, or medium <br />density fiberboard complying with ANSI A208.2, Grade MD with surface of thermally fused, melamine -impregnated decorative paper <br />complying with LMA SAT-1. <br />6. Countertops: <br />a. Type of Top: Chemical resistant high pressure decorative laminates NEMA LD3, Grade HGP, Test Procedure 3.9.5, <br />GP-50. <br />b. Type of Top: High Pressure plastic laminate for exposed cabinet and counter surfaces: Meet NEMA LD3 standards for <br />non -vertical grade laminate, GP-28. <br />c. Type of Top: Homogeneous solid sheet material of filled plastic resin complying with materials and performance <br />requirements in ANSI Z 124.3 for type 5 or type 6, without a pre -coated finish and joint adhesive especially manufactured for <br />joining sheets in color to match material. <br />7. Integral Bowl Sinks: Rectangular sink, homogeneous solid sheet material of filled plastic resin complying with materials and <br />performance requirements in ANSI Z124.3 for type 5 or type 6, without a pre -coated finish and joint adhesive especially manufactured <br />for joining sheets in color to match material. Include front bowl overflows and associated drain connection and coordinate with <br />plumbing components. <br />a. S-1: 19" x 19" x 5.5" <br />b. S-2: 22" x 22" x 5.5" <br />8. Provide 2" radius front corners of countertops. <br />9. All doors, drawers and countertops shall have thermoset minimum 1 mm PVC edge banding. <br />10. Sink sub -tops: Marine Plywood, Veneer -core, type 1 glue, no voids, B-B face veneer, species Contractor's option. <br />11. Hardware: <br />a. Provide cabinet hardware and accessory materials for cabinets as indicated. Hardware items not shown but required for <br />function indicated shall be furnished in the same finish and quality. Hardware shall comply with ADA, BHMA A156.9. <br />b. Pulls: Stanley 348311, (4") wire pulls, back mounted, satin aluminum. <br />c.Shelf supports: Pre -drilled 5mm holes at 32mm o.c. with adjustable polycarbonate locking shelf brackets. <br />d. Drawer slides: KV8400, rated 100lbs., side mounting, full extension <br />e. Hinges for cabinets: Model 90M2550 by Blum Inc.; 100 degree, all metal nickel plated, without spring <br />f. Continuous hinges: Stanley No. SC311, steel. <br />g. Locks: Corbin Cabinet Lock No. 02065, BHMAA156.11, E0704.1 <br />h. Shelf standards: Knape and Vogt No. 255 Pilaster Standards, steel. <br />i. Grommet: 2" Molded plastic and matching plastic caps with slot for wire passage, black. <br />j. Counter support: RAKKS, Model EH-1818 for counters 24" deep and less and Model ED-1824 for counters over 24" deep. <br />13. Engineered Resin: Varia EcoResin by 3form, '/", style as noted on Finish Drawings. <br />DIVISION 7 - THERMAL AND MOISTURE PROTECTION <br />07-2100 THERMAL INSULATION (to be included as part of EIFS pre -manufactured exterior wall panel) <br />07-2400 EXTERIOR INSULATION AND FINISH SYSTEM <br />1.EIFS exterior wall panel and soffit system to be pre-engineered, pre -manufactured and delivered to jobsite as a ready to install <br />component. <br />2. Properties of the Exterior Insulation and Finish System (EIFS) are as follows: <br />a. Class PB, utilized as a barrier equivalent to STO Quik Gold System as manufactured by Sto Corp. <br />b. All air and water resistive barrier, Insulation and finish system materials from a single manufacturer from sources <br />specifically recommended by the prime manufacturer. Use only products that will not void EIFS manufacturer warranty. <br />c. Provide warranty for a period of 12 years for wall system. <br />d. Fluid Applied Air Barrier Membrane to be StoGuard StoGold Coat, as manufactured by Sto Corp., minimum f=of 19 mils <br />dry. Transition membrane and joint treatment to be as recommended by Sto. <br />e. Finish to be Stolit Fine, color to be selected by Architect. <br />f. High impact mesh panels shall be installed as specified at ground level, high traffic areas and other areas exposed to our <br />susceptible to impact damage. <br />07-5423- THERMOPLASTIC POLYOLEFIN (TPO) ROOFING <br />1. Roof: provide GAF EverGuard 60 mil TPO, smooth white surfaced roofing membrane. System to be fully adhered. <br />2. Roof Insulation: Provide flat and tapered polyisocyanurate board (total R22). <br />3. Walk boards: Provide'/" high density fiberboards for roof protection surrounding rooftop equipment. <br />07-6207 SHOP FABRICATED SHEET METAL <br />1. Fabricate and install rain drainage components per SMACNA "Architectural Sheet Metal Manual" standard details and <br />anchorage guidelines. <br />2. Pre -finished Galvanized Steel Sheet: 24 gauge min equivalent, ASTM A525, G90, with factory -applied <br />fluoropolymercoating (AAMA 2604)finish with sheet metal clips, continuous cleats, straps, anchoring devices, as required for <br />installation of work, matching or compatible with adjoining materials, noncorrosive, size and gauge required for performance. <br />3. Fasteners: Same material and finishes flashing metal, with soft neoprene washers. Match finish of exposed heads with <br />material being fastened. <br />4. Protect metal from no compatible metal or corrosive substrates by coating with protective backing paint as recommended <br />by manufacturer/fabricator. <br />5. Hem exposed edges on underside'/2 inch; miter and seam comers, Form material with flat lock seams, except where <br />otherwise indicated. At moving joints, use sealed lapped, bayonet -type or interlocking hooked seams. <br />6. Anchor work securely in place by methods indicated, providing for thermal expansion; conceal fasteners where possible. <br />7. Protect flashings and sheet metal work during construction from damage or deterioration. <br />07-8400 FIRESTOPPING <br />1. Provide materials listed in the UL Building Materials Directory and approved by FM, current edition at time of application, as "Fill, <br />Void or Cavity Materials" and as "Through Penetration Firestop Systems". <br />2. Refer to drawings for details each penetration type and associated UL number. <br />3. Provide products per building standards for each penetration type. <br />07-0200 JOINT SEALANTS <br />1. Medium Modulus Silicone Exterior Wall Sealant: One -part medium -modulus, Type II, silicone sealant, non -sag, Class "A", <br />consisting of the following physical properties as tested by Fed. Spec. TT-S-00230C, Class A and ASTM C-920, Class 25, Type S, <br />Grade NS; Pecora 895 NTS or Dow Coming, 795. <br />2. Sanitary Mildew Resistant Silicone Sealant: One -part, very low odor, neutral -curing silicone for interior applications consisting of the <br />following physical properties as tested by TT-S-001543A, TT-S-00230C, Class A and ASTM C920, Class 25; Pecora's 898 or Dow <br />Coming, 786. Use for sealing perimeters of fixtures in kitchens and other hygienic facilities. Color to be clear. <br />3. Acrylic Latex Interior Sealing Compound: One -part acrylic latex+silicone, non -sag, gun -grade consistency, paintable with latex or <br />oil paint, mildew -resistant, USDA approved, ASTM C834 quality; Pecora "AC-20" or Dow Coming, 786. Use for sealing around the <br />perimeters of doors and windows, countertops, electrical boxes and other interior locations. Color to be clear. <br />4. Install primers and sealers as recommended by sealant and substrate manufacturers. <br />5. Provide 5-year manufacturer's warranty for all types of sealant used. <br />07-4450 FIBER -REINFORCED CEMENTITIOUS PANELS <br />1. Work includes prefinished fiber -reinforced cementitious panels mounted in a ventilated rainscreen system. <br />2. System includes precut panels, cold -formed metal supports, clips and fasteners. <br />3. Basis of design manufacturer: Swisspearl; www.swisspearl.com. <br />4. Design windloads: As required by International Building Code and standard industry practice. <br />5. Fire resistance in compliance with ASTM E84 and NFPA 285; <br />6. Noncombustible <br />7. Flame spread index 0 <br />8. Smoke developed 15 or less <br />9. NFPA Class A <br />10. Exhibits no flame after 30 minutes continuous exposure. <br />11. Panel thickness 8 millimeters. <br />12. Cold -formed metal supporting system and clips to be minimum 16 gauge galvanized steel. <br />13. Concealed fastening: Sigma 8 system. <br />14. Acrylic Finish Colors: <br />A. Carat SL Crystal 7010 <br />B. Vinatgo V1001 <br />15. Exposed joint flashings: Manufacturer's standard aluminum sections in finish to match curtain wall framing, unless otherwise <br />noted. <br />16. Installation to be plumb, plane, and square as indicated and per manufacturer's written recommendations. <br />DIVISION 8 - OPENINGS <br />08-11 13 HOLLOW METAL DOORS AND FRAMES <br />1. Steel door and window frames: Welded -unit construction of cold -rolled steel conforming to ASTM A366, free of defects, warp and <br />buckle. Comer joints to be mitered in true alignment and welded continuously on inside of frame. Double -return flanges to be provided <br />at all frames except those in existing openings. <br />2. Install drip strips at heads of exterior in door frames. <br />3. Exterior frames: 16 gauge, hot -dipped galvanized steel with ASTM A924/G60 or A60zinc coating; bonderized and coated with zinc - <br />chromate rust -inhibitive primer, baked -on. <br />4.Interior frames: 16 gauge steel, bonderized and coated with zinc chromate rust -inhibitive primer, baked -on. <br />5. Prepare frames and doors at BLOX Facility for installation of hardware. <br />6. Anchors: Four 18 gauge galvanized steel stud anchors at each jam up to 7'-6" height; one additional anchor required for each 18 <br />inches or fraction thereof over 7'-6" height. <br />7. Steel thermal doors: 1-3/4" thick, flush type, seamless, with two face sheets of 16 gauge for exterior doors conforming to ASTM <br />A366. Finish to be hot -dipped galvanized steel with ASTM A924/G60 zinc coating, bonderized and coated with zinc -chromate rust - <br />inhibitive primer, baked -on. Vertical stiffeners shall be of channel -shaped steel on nominal 6" spacings, welded to both face sheets. <br />Close with 16 gauge steel channels. Doors fabricated with thermal -resistance value (R-value) of not less than 4.0 deg F x h x sq. <br />ft./Btu. Fill interior doors with spun mineral wool to deaden metallic sound. Under cuts greater than 5/6" are not acceptable. <br />8. Where fire -related door and frame assemblies are indicated or required, provided fire -rated assemblies that comply with NFPA 80, <br />which have been tested, listed and labeled in accordance with ASTM E152 by a nationally recognized independent testing and <br />inspection agency acceptable to authorities having jurisdiction and FM approved. <br />a. Provide UL and FM labels on glazing and frames. <br />b. Perimeter seals and astragals to be provided by door manufacturers. <br />9. Install frames, and accessories in accordance with final shop drawings and SDI-105. <br />08-1423 LAMINATE PLASTIC FACED WOOD DOORS <br />1. Related Sections: Hollow Metal Doors and Frames, Door Hardware, Glazing. <br />2. Reference Standards: ASTM E413, ASTM 1408, AWU/AWMAC/WI Architectural Woodwork Standards, NEMA LD 3 - High <br />Pressure Decorative Laminates, UL (BMD) and UL 1784. <br />3. Submittals to include: Product Data, Shop Drawings with elevations, swing, ratings, construction, finishes (including edges) <br />thickness, locations, glazing stops and undercuts. <br />4. Comply with AHJ code requirements. Label all doors as required. <br />5. Store to ensure protection: individually packaged, deliver after building enclosed, store flat with no material placed on top of doors <br />and do not drag into place. <br />6. Provide standard manufacturer's warranty. <br />7. Doors to be equal to "Perms -Clad" laminated plastic clad doors by VT Industries, Inc. <br />8. Materials: <br />a. Particle Board Cores, grade 1-LD-2. <br />b. Laminated Plastic: NEMA LD3, Type 1 general purpose, 1/16" thick. <br />c. Stiles and Rails suitable for hanging on full mortise butt hinges. <br />d. Edge Bands matching faces including top rail. <br />e. All doors are solid core, 1 %" thick <br />f. Lead lined doors with to have 1/16" thick 4 lb. lead <br />9. Pre -fit and precut doors at factory for hardware and vision panels. Do not trim doors on site. <br />10. Tolerances at heads and jambs, max. 1/8". Floor clearance, %" max. <br />11. Replace damaged doors whether by installation or subsequent construction. <br />RETAIL CLINIC <br />ACCESS DOORS <br />ADDITION <br />TO <br />1. Sized <br />1. Sized as required for appropriate access with 16 gauge galvanized steel frame, 18 gauge reinforced galvanized steel door panel, <br />continuous steel hinge with stainless steel pin and flush, key -operated cylinder type lock equivalent to AP access doors for stucco <br />ceilings as manufactured by Milcor. <br />ZE P HYRH I LLS <br />2. Finish shall be prime coated with factory applied baked -on electrostatic powder, with edge exposed. Edges painted with prime coat <br />of white, rust inhibitive paint. <br />WALMART 706 <br />08-4229 SLIDING AUTOMATIC ENTRANCES <br />1. Section includes automatic sliding door system for exterior and interior openings. <br />2. Provide shop drawings in English with elevations, plans, sections, hardware locations, attachment details, power, signal and control <br />wiring, activation and safety devices. <br />3. Provide standard components warranty of 2 years, finish warranty of 5 years along with maintenance and operations manual at <br />closeout. <br />4. Entrance system to be supplied by Assa Abloy. Minimum 45" clear opening at locations shown on drawings. <br />5. Comply with applicable seismic and wind load requirements for impact resistance as noted in the drawings. <br />6. Door system to include all components needed for a complete installation including and not limited to the automatic operator, <br />weatherstripping, frames, doors & sidelights, emergency breakaway at exit doors, 2 point lock, position switches, opening settings of <br />GA PROJECT No: 20CE14 <br />hold -open, off, automatic and motion presence sensors. <br />7. Coordinate with electrical subcontractor for 110v, 60 Hz, 10amp power needed. <br />08-4413 Glazed Aluminum Curtain Walls <br />GIATTINA AYCOCK <br />1. Swing -door entrances and framing system of 6063-T5 aluminum and glass construction equivalent to Kawneer Trifab II 450 for 1" <br />ARCHITECTURE STUDIO INC. <br />insulated glass framing system and Kawneer 350 Medium Stile for %' glazing for doors with 70% fluoropolymer based coating meeting <br />2625 5th Avenue North, Building C <br />or exceeding AAMA 2605. Subsills to be continuous and complete with end -dams. All framing members to be thermally insulated. <br />• r Bessemer, AL 35020 <br />2. Comply with applicable seismic and wind load requirements for impact resistance as noted in the drawings. <br />P: 205.933.9060 <br />3. Hardware: RIM panic devices with lock, push/pullbars, extruded aluminum threshold for offset pivots and surface overhead closers <br />GASTUDIO.COM <br />with built-in holder, bottom rail sweep, weather stripping and drip edge. <br />4. Assemblies shall be installed plumb, level and free of warp or twist. <br />5. Set subsills and thresholds in solid bed of mastic. <br />6. Install batt insulation in shim spaces around perimeter off frame assemblies, to maintain continuity of thermal barrier. <br />7. Provide written certificate guaranteeing the necessary repairs of faulty materials and workmanship to maintain the entrance/framing <br />system in a watertight and air tight condition for period of two years. <br />08-7100 DOOR HARDWARE <br />1. Each type of hardware will be from a single manufacturer. <br />2. Hardware for fire rated openings will comply with NFPA 80, tested per UL or other acceptable organization, and <br />acceptable to authorities having jurisdiction. <br />3. Hardware will comply with Americans with Disabilities Act (ADA) <br />4. Hardware: <br />5. Hinges <br />A. McKinney (TA2714 / T4A3786) <br />B. Pemko - Continuous Hinge (CFM83 HD1) <br />C. Locks and Cylinders - Sargent (10-LINE) <br />D. Exit Devices - Sargent (8800 Series) <br />E. Closers - Sargent (422 Series Cam Action Closers) <br />F. Flush Bolts - Rockwood (555 Flush Bolts) <br />STAMP: <br />G. Push/Pull/Kick plates - Hager or Rockwood <br />H. Overhead Stops and Holders - Rixson (1ADJ-HD Concealed Series) <br />I. Stops and Miscellaneous Items - Hager or Rockwood <br />O F F4 <br />J. Thresholds and Weatherstripping- Pemko (S88BL Gasketing) <br />� O <br />: ............. <br />> t. • �® <br />�- ,q y; <br />� �' '• <br />6. Electronic Products - <br />z •' k. <br />CO O' F <br />A. HES (1500C Elec. Strike) <br />B. HES (9600 Elec. Strike) <br />C. Securitron (EEB3N Push Button Release) <br />D. Securitron (XMS Motion Sensor) <br />��; 95 <br />E. Securitron (DM62 - Mag Lock) <br />F. Securitron (BPS-24-2 & BPS-24-4 Power Supplies) <br />��':{ <br />"American <br />5. Finishes: Listed in ANSI/BHMA A156.18 Standards for Materials and Finishes". <br />A. TBD <br />6. Keying: <br />A. System to be as determined by Owner. <br />B. Two (2) keys will be provided per lock. <br />7. Hardware Sets: <br />ISSUE SCHEDULE: <br />Hardware Set # 01 <br />Doors: 142, 152, 181, 182 <br />3 <br />EA <br />Hinge <br />1 <br />EA <br />Privacy Lock <br />1 <br />EA <br />Concealed OVHD Holder/Stop <br />1 <br />EA <br />Kick Plate <br />3 <br />EA <br />Silencer <br />Hardware Set # 02 <br />Doors: <br />112, 113, <br />125, 126 <br />4 <br />EA <br />Hinge <br />1 <br />EA <br />Passage Latch <br />1 <br />EA <br />Concealed OVHD Holder/Stop <br />3 <br />EA <br />Silencer <br />TA2714 4-1/2" x 4-1/2" US26D MK <br />28 1OU65 LP US26D SA <br />1ADJ-336 630 RF <br />K105010" x 34" US32D BEV CSK RO <br />608-RKW RO <br />T4A3786 4-1/2" x 4-1/2" US26D MK <br />28 1OU15 LP US26D SA <br />1ADJ-436 630 RF <br />608-RKW RO <br />Hardware Set # 03A <br />Doors: 114 <br />ALL OTHER ACCESS CONTROL NOT LISTED IS TO BE PROVIDED BY JCI. (ELEC. STRIKE SHOWN WILL BE <br />PROVIDED BY RAYFORD AND ASSOCIATES, INC.) <br />4 EA <br />Hinge <br />TA2714 4-1/2" x 4-1/2" US26D <br />MK <br />1 EA <br />Storeroom/Closet Lock <br />28 10G04 LP US26D LA <br />SA <br />1 EA <br />Electric Strike <br />1500C 630 <br />HS <br />1 EA <br />Surface Closer <br />422 CTB2 EN <br />SA <br />3 EA <br />Silencer <br />608-RKW <br />RO <br />Hardware Set # 04 <br />Doors: 133A, 134A, <br />135A, 143A, 144A <br />4 EA <br />Hinge <br />TA2714 4-1/2" x 4-1/2" US26D <br />MK <br />1 EA <br />Passage Latch <br />28 1OU15 LP US26D <br />SA <br />1 EA <br />Concealed OVHD Holder/Stop 1ADJ-136 630 <br />RF <br />3 EA <br />Silencer <br />608-RKW <br />RO <br />Hardware Set # 05 <br />Doors: 145A <br />3 EA <br />Hinge <br />TA2714 4-1/2" x 4-1/2" US26D <br />MK <br />1 EA <br />Storeroom/Closet Lock <br />28 10G04 LP US26D LA <br />SA <br />1 EA <br />Concealed OVHD Holder/Stop <br />1ADJ-336 630 <br />RF <br />1 EA <br />Kick Plate <br />K1050 10" x 34" US32D BEV CSK <br />RO <br />3 EA <br />Silencer <br />608-RKW <br />RO <br />Hardware Set # 06 <br />Doors: 162, 165 <br />3 <br />EA <br />Hinge <br />TA2714 4-1/2" x 4-1/2" US26D <br />MK <br />1 <br />EA <br />Passage Latch <br />28 1OU15 LP US26D <br />SA <br />1 <br />EA <br />Concealed OVHD Holder/Stop <br />1ADJ-336 630 <br />RF <br />3 <br />EA <br />Silencer <br />608-RKW <br />RO <br />Hardware Set # 06A <br />Doors: <br />141, 151 <br />B <br />3 <br />EA <br />Hinge <br />TA2714 4-1/2" x 4-1/2" US26D <br />MK <br />1 <br />EA <br />Storeroom/Closet Lock <br />2810G04 LP US26D LA <br />SA <br />1 <br />EA <br />Concealed OVHD Holder/Stop <br />1ADJ-336 630 <br />RF <br />1 <br />EA <br />Kick Plate <br />K1050 10" x 34" US32D BEV CSK <br />RO <br />3 <br />EA <br />Silencer <br />608-RKW <br />RO <br />Hardware Set # 07 <br />Doors: <br />172A <br />3 <br />EA <br />Hinge <br />TA2714 4-1/2" x 4-1/2" US26D <br />MK <br />1 <br />EA <br />Classroom Lock <br />2810G37 LP US26D LA <br />SA <br />1 <br />EA <br />Surface OVHD Holder/Stop <br />1ADJ-336 630 <br />RF <br />3 <br />EA <br />Silencer <br />608-RKW <br />RO <br />Hardware Set # 08 <br />Doors: <br />124 <br />1 <br />EA <br />Continuous Hinge <br />CFM83HD1 <br />PE <br />1 <br />EA <br />Classroom Lock <br />28 74 10G37 LP US26D LA <br />SA <br />1 <br />EA <br />Concealed Overhead Holder/Stop <br />1ADJ-436 630 <br />RF <br />2 <br />EA <br />Kick Plate <br />K1050 10" x 40" US32D BEV CSK <br />RO <br />1 <br />EA <br />Gasketing <br />S88BL 18' <br />PE <br />Hardware Set # 09 (NOT USED <br />Hardware Set # 10 <br />Doors: 172 <br />ALL OTHER ACCESS CONTROL NOT LISTED IS TO BE PROVIDED BY JCI. (ELEC. STRIKE SHOWN WILL BE <br />PROVIDED BY RAYFORD AND ASSOCIATES, <br />INC.) <br />3 EA Hinge <br />TA2714 4-1/2" x 4-1/2" US26D <br />MK <br />1 EA Storeroom/Closet Lock <br />28 73 10G04 LP US26D <br />SA <br />1 EA Electric Strike <br />1500C 630 <br />HS <br />1 EA Surface Closer <br />422 CTB2 EN <br />SA <br />1 EA Kick Plate <br />K1050 10" x 34" US32D BEV CSK <br />RO <br />3 EA Silencer <br />608-RKW <br />RO <br />Hardware Set # 11 <br />Doors: 101, 101A, 102 <br />ALL HARDWARE PROVIDED BY SLIDING DOOR AND FRAME MFG <br />Hardware Set # 12 (NOT USED) <br />Hardware Set # 13 (NOT USED <br />Hardware Set # 14 <br />Doors: 103,105 <br />ALL OTHER ACCESS CONTROL NOT LISTED IS TO BE PROVIDED BY JCI. (ELEC. STRIKE SHOWN WILL BE <br />PROVIDED BY RAYFORD & ASSOCIATES, INC.). <br />1 EA Rim Exit Device 73 AD8504 G ETL US32D SA <br />1 EA Electric Strike 9600 630 HS <br />ALL DOOR HARDWARE BELOW IS TO BE PROVIDED BY ALUM. DOOR SUPPLIER. <br />3 EA Butt Hinges by Kawneer - Ball Bearing Type Required <br />1 EA Closer, Gasketing, Threshold, Door Sweep By Kawneer <br />1 EA Push Pull Handing To Be Provided <br />1 EA Concealed Closer LCN 2035 <br />Hardware Set # 15 <br />Doors: 132, 151, 161, 123, 133, 134, 135, 143, 144, 145, 153, 183 <br />ALL HARDWARE PROVIDED BY DOOR AND FRAME MFG. <br />Hardware Set # 16 (NOT USED) <br />Hardware Set # 17 <br />Doors: 171 <br />THIS SLIDER CURRENTLY HAS A LOCK AND SELF CLOSING DEVICE PROVIDED BY DOOR MFG. <br />ALL OTHER HARDWARE PROVIDED BY DOOR AND FRAME MFG. <br />1 EA Small Format Inter Core 7300B US15 SA <br />REVISION SCHEDULE: <br />NUM. DESCRIPTION DATE <br />NOTES & LEGEND <br />CURRENT DRAWING SET: <br />PERMIT SET <br />ISSUE DATE: 11/25/2020 <br />DRAWN BY: JLM <br />SHEET: <br />ARCHITECTURAL <br />SPECIFICATIONS <br />BIM 360://WMT-C1inic-20WM00 - Prototype/6500R-Clinic-V3.1a-Prototype.rvt <br />A601 <br />11 /23/2020 11:36:16 AM 16 of 17 <br />