Laserfiche WebLink
7 <br />6 5 <br />4 <br />3 <br />2 <br />1 <br />9 <br />E <br />N <br />U <br />SYMBOLS LEGEND <br />X-XX - REFERENCE AT KEYNOTE INDICATOR <br />10.1 KEYNOTE INDICATOR <br />A KEYNOTE OR BLOCK OF <br />X.XX KEYNOTES WITH A LEADER <br />X.XX ATTACHED APPLY SPECIFICALLY <br />X.XX TO THE ITEM, AREA, OR SURFACE <br />TO WHICH THE LEADER IS <br />SALES POINTING <br />IN ADDITION TO THE ROOM FINISH <br />100 I SCHEDULE, A KEYNOTE OR BLOCK <br />X.XX X.XX OF KEYNOTES ATTACHED TO THE <br />X.XX X.XX ROOM NAME TAG APPLY TO THE <br />X.XX X.XX ENTIRE ROOM <br />r Pam', COLOR INDICATOR <br />2 FULL AND PARTIAL <br />2-A2 A2 SECTION INDICATOR <br />_ A( 2 EXTERIOR AND INTERIOR <br />2-A2 A2 ELEVATION INDICATOR <br />SALES <br />F-lool ROOM NAME AND NUMBER <br />A6 PARTITION TYPE INDICATOR <br />1001 DOOR INDICATOR <br />MO WINDOW INDICATOR <br />TV MONITOR <br />--- - COLUMN LINE INDICATOR <br />100--0" HEIGHT ELEVATION INDICATOR <br />INV FF EL <br />100'-0" PLAN ELEVATION INDICATOR <br />5 <br />A2 <br />I ENLARGED DETAIL INDICATOR <br />l J <br />r5_"� <br />A2 <br />DETAIL INDICATOR <br />TACTILE EXIT SIGN <br />TACTILE SIGN REQUIREMENTS <br />1. A TACTILE SIGN STATING "EXIT" AND COMPLYING WITH ANSI Al 17.1 SHALL BE PROVIDED ADJACENT <br />TO EACH DOOR TO AN EXIT PASSAGEWAY AND THE EXIT DISCHARGE. REF FLOOR PLANS FOR <br />LOCATIONS. <br />2. FOR CHARACTER WIDTH, THE UPPERCASE LETTER "0" SHALL BE USED TO DETERMINE THE <br />ALLOWABLE WIDTH OF ALL CHARACTERS OF A FONT. THE WIDTH OF THE UPPERCASE LETTER "0" <br />OF THE FONT SHALL BE 55 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE <br />UPPERCASE "I" OF THE FONT. (ANSI Al 17.1-2009: 703.3.6) CHARACTER HEIGHT MEASURED FROM <br />THE BASELINE OF THE CHARACTER SHALL BE 5/8" (16 MM) MINIMUM AND 2 INCHES (51 MM) <br />MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". <br />3. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. <br />4. CHARACTERS SHALL CONFORM TO THE FOLLOWING: <br />4.a. LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MINIMUM AND SHALL BE SANS - <br />SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE. <br />4.b. RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8" HIGH AND A MAXIMUM OF 2". <br />5. CONTRACTED GRADE 2 BRAILLE SHALL BE USED. DOTS SHALL BE 0.090" (2.3 MM) TO 0.100" (2.5 MM) <br />ON CENTER IN EACH CELL WITH 0.241" (6.1 MM) TO 0.300" (7.6 MM) SPACE BETWEEN CELLS. DOTS <br />SHALL BE RAISED A MINIMUM OF 0.025" (0.6 MM) TO 0.037" (0.9 MM) ABOVE THE BACKGROUND. <br />6. CHARACTERS SHALL BE 48" MINIMUM ABOVE FINISH FLOOR MEASURED FROM THE BASE OF THE <br />LOWEST TACTILE CHARACTER AND 60" MAXIMUM ABOVE FINISH FLOOR MEASURED FROM THE <br />BASELINE OF THE HIGHEST TACTILE CHARACTER. <br />7. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE ALONGSIDE THE DOOR AT <br />THE LATCH SIDE. AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON <br />THE INACTIVE LEAF. AT DOUBLE DOORS WITH TWO ACTIVE LEAVES, THE SIGN SHALL BE TO THE <br />RIGHT OF THE RIGHT-HAND DOOR. TACTILE SIGNS ARE PERMITTED ON THE PUSH SIDE OF DOORS <br />WITH CLOSERS AND WITHOUT HOLD -OPEN DEVICES. SEE ALTERNATE SOLUTIONS FOR OTHER <br />SCENARIOS. <br />PREFERRED SOLUTION <br />ram. <br />SIGNS CONTAINING TACTILE <br />CHARACTERS SHALL BE <br />LOCATED SO THAT THERE IS <br />L - <br />AN 18"X18" CLEAR FLOOR <br />AREA CENTERED ON THE <br />TACTILE CHARACTERS <br />ALTERNATE SOLUTIONS <br />- <br />A. WHERE THERE IS NO B. THE REQUIRED SIGNAGE MAY <br />ALTERNATE LOCATION �_, WALL SPACE ON THE BE INSTALLED SO THAT THE <br />(NEAREST ADJACENT LATCH SIDE OF A SINGLE CLEAR FLOOR AREA IS BEYOND <br />WALL, RIGHT HAND SIDE �., \ DOOR, OR TO THE RIGHT THE ARC OF ANY DOOR SWING <br />OF OPENING PREFERRED) SIDE OF DOUBLE DOORS, BETWEEN THE CLOSED POSITION <br />SIGNS SHALL BE ON THE AND 45 DEGREE OPEN POSITION. <br />NEAREST ADJACENT <br />WALL. <br />V <br />F d4 <br />C. WHEN SIGN IS REQUIRED AT <br />A BANK OF DOORS, PLACE (1) <br />SIGN BETWEEN JAMBS. IF <br />JAMB IS NOT WIDE ENOUGH FOR <br />SIGNAGE, PLACE (1) SIGN AT <br />RIGHT SIDE OF BANK OF DOORS. <br />12" MIN0 <br />E. WHERE WALL STANDARDS <br />IMPEDE THE REQUIRED <br />CLEAR FLOOR AREA, MOUNT <br />SIGN DIRECTLY TO DOOR. <br />ENSURE DOOR HAS <br />AUTOMATIC CLOSER AND <br />DOES NOT HAVE A <br />HOLD -OPEN DEVICE. <br />ALTERNATE LOCATION <br />(NEAREST ADJACENT <br />WALL, RIGHT-HAND SIDE <br />OF OPENING PREFERRED) <br />D. WHERE REFRIGERATED CASES OR <br />FIXTURES IMPEDE THE REQUIRED <br />CLEAN FLOOR AREA, MOUNT <br />SIGNAGE TO THE END PANEL OF <br />CASE OR OWNER PROVIDED END <br />PANEL FOR HALF GONDOLAS AND <br />WALL STANDARD FIXTURES. <br />rT <br />12" MIN <br />F. AT EGRESS DOORS IN THE <br />GARDEN CENTER WHERE THERE <br />IS NOT AMPLE WALL SPACE FOR <br />SIGNAGE, MOUNT SIGN DIRECTLY <br />TO DOOR. ENSURE DOOR HAS <br />AUTOMATIC CLOSER AND DOES <br />NOT HAVE A HOLD -OPEN DEVICE. <br />F I <br />'REFERRED <br />RIGHT-HAND SIDE, <br />kDJACENT TO DOOR) <br />G. AUTOMATIC SLIDING DOOR <br />LOCATIONS F <br />TACTILE SIGNAGE CANNOT <br />BE LOCATED ON AUTOMATIC <br />SLIDING DOOR PANELS. <br />PANEL WIDTH TO MATCH <br />DEPTH OF WAREHOUSE RACK <br />U- z <br />} Q 0 <br />m I CL Q <br />O �, w <br />w <br />ELEVATION PLAN <br />H. WHERE WAREHOUSE RACKS IMPEDE THE REQUIRED CLEAR FLOOR AREA <br />ADJACENT TO THE DOOR, PROVIDE 3/8" A-B PLYWOOD PANEL WITH EASED <br />EDGES AND ATTACH TO THE END OF THE WAREHOUSE RACK USING (4) <br />GALVANIZED CARRIAGE BOLTS, WASHERS AND LOCKNUTS. CARRIAGE BOLTS <br />ARE TO BE SIZED PROPERLY TO ENSURE THE BOLT END DOES NOT <br />PROTRUDE BEYOND THE TOP OF LOCKNUT AND PANEL IS SECURE. IN <br />GROCERY SERVICE AND PREPARATION AREAS, PAINT PLYWOOD P33 UNO. <br />SITE VERIFICATION REQUIREMENTS: <br />1. THE ARCHITECT HAS MADE A SCOPE VISIT WITH MEASUREMENTS AND PHOTOGRAPHS OF EXISTING CONDITIONS AND THE ARCHITECTURAL DRAWINGS <br />INDICATE EXISTING CONDITIONS VERIFIED IN THE FIELD. IT, HOWEVER, REMAINS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING <br />CONDITIONS PRIOR TO THE SUBMISSION OF A BID AND TO THE COMMENCEMENT OF ANY WORK. NO ADDITIONAL COMPENSATION WILL BE PAID DUE TO THE <br />CONTRACTOR'S FAILURE TO VERIFY EXISTING SITE CONDITIONS WHICH INCLUDE, BUT ARE NOT LIMITED TO, GRADES, EXTENT OF PAVING, OR UTILITIES. <br />2. ANY DISCREPANCY WITH THE EXISTING SITE CONDITIONS AND/OR THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR <br />CLARIFICATION AND INSTRUCTION. THESE CONSTRUCTION DOCUMENTS HAVE BEEN DESIGNED AND DRAWN ASSUMING EXISTING BUILDING CONDITIONS <br />MATCH THE ORIGINAL DRAWINGS. THE GENERAL CONTRACTOR, IMMEDIATELY UPON ARRIVAL AT THE SITE, SHALL VERIFY ALL EXISTING STRUCTURAL <br />COLUMN DIMENSIONS, STRUCTURAL BEARING HEIGHTS, EXISTING DIMENSIONS, TOP OF MASONRY ELEVATIONS, ROOFING CONDITIONS (INCLUDING <br />PARAPETS, SCUPPERS AND ROOF DRAINS), AND JOIST BEARING ELEVATIONS PRIOR TO THE FABRICATION OF ANY STRUCTURAL ITEMS. IF DISCREPANCIES <br />ARE FOUND BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND EXISTING FIELD CONDITIONS, CONTACT THE WALMART CONSTRUCTION MANAGER AND THE <br />ARCHITECT IMMEDIATELY TO DETERMINE WHAT ACTION SHOULD BE TAKEN TO MATCH EXISTING CONDITIONS. THE BEGINNING OF STRUCTURAL STEEL <br />FABRICATION BY THE GENERAL CONTRACTOR, STEEL FABRICATOR, OR JOIST MANUFACTURER MEANS ACCEPTANCE OF THE EXISTING CONDITIONS. <br />3. ALL UTILITY LOCATIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES (WHETHER <br />SHOWN OR NOT) PRIOR TO THE SUBMISSION OF A BID OR THE COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE WALMART <br />CONSTRUCTION MANAGER OF THE DISCOVERY OF EXISTING UTILITIES NOT SHOWN OR NOTED ON DRAWINGS. <br />4. THE CONTRACTOR SHALL VERIFY AND MAINTAIN (REPAIR IF DAMAGED) EXISTING IRRIGATION SYSTEMS AFFECTED BY THE CONSTRUCTION OF THIS <br />PROJECT. <br />5. THE CONTRACTOR SHALL FIELD LOCATE AND VERIFY ALL PROPERTY LINES, EASEMENTS, SETBACKS AND RESTRICTIONS. A REGISTERED SURVEYOR SHALL <br />ESTABLISH ALL PROPERTY LINES AND SETBACKS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND CLEARLY FLAG PROPERTY LINES AND SETBACKS. <br />IT REMAINS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DETERMINE EXACT LOCATION OF ALL SAID BOUNDARIES. <br />6. THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DEPTHS OF UNDERGROUND UTILITY SERVICES PRIOR TO ANY EXCAVATION. <br />7. THE CONTRACTOR SHALL VERIFY ALL GRADES AND PROPOSED FINAL GRADES. IF RAMPS, STOOPS, STAIRS, SIDEWALKS, FATWORK OR PAVING ARE <br />INSTALLED, VERIFY FINAL GRADES SURROUNDING THE NEW CONSTRUCTION AND ADJUST STAIR RISERS, RAMP LENGTHS, LIMITS OF PAVING, ETC., TO <br />ACCOMMODATE THE REQUIRED RAMP SLOPE, RISER HEIGHTS OR PAVING AREAS. ALL RAMPS AND STAIRS SHALL MEET ADA-ADAAGS (OR ADOPTED <br />HANDICAP ACCESSIBILITY REQUIREMENTS). IF THERE IS A CONFLICT IN FIELD CONDITIONS, NOTIFY WALMART CONSTRUCTION MANAGER AND THE <br />ARCHITECT PRIOR TO THE CONSTRUCTION OR ORDERING OF MATERIALS. <br />8. THE CONTRACTOR SHALL VERIFY THE EXISTING FINISH FLOOR ELEVATION AT ALL NEW OPENINGS OF THE EXISTING BUILDING PRIOR TO ESTABLISHING THE <br />FINISH FLOOR ELEVATION. TO VERIFY FLOOR ELEVATION, THE CONTRACTOR SHALL REMOVE A SMALL PORTION OF THE BLOCK WALL AT THE PROPOSED <br />OPENING BETWEEN THE EXISTING STORE AND THE ADDITION. <br />9. THE CONTRACTOR SHALL VERIFY EXISTING FOOTING DEPTHS AND MATCH AT NEW ADDITION TO INSURE PROPER BLOCK COURSING. ANY DISCREPANCY <br />SHALL BE REPORTED TO THE WALMART CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. <br />10. THE CONTRACTOR SHALL CORE THE ROOF INSULATION TO DETERMINE ITS THICKNESS AFTER CONTRACT AWARD. IT IS THE CONTRACTOR'S RESPONSIBILITY <br />TO MATCH EXISTING ROOF INSULATION THICKNESS ON THE ADDITION UNLESS DIRECTED OTHERWISE TO INSTALL 3-INCH INSULATION IN SEPARATED AND <br />ISOLATED ROOF CONDITIONS. REFER TO ROOFING SPECIFICATION SECTION. <br />11. REPORT ANY DISCREPANCIES FOUND IN THE FIELD IMMEDIATELY TO WALMART AND THE ARCHITECT PRIOR TO MAKING ANY STRUCTURAL MODIFICATIONS <br />OR ORDERING OF ANY MATERIALS. <br />GENERAL CONSTRUCTION REQUIREMENTS: <br />1. ALL WORK SHALL BE DONE IN A SAFE AND WORKMANLIKE MANNER AND IN STRICT ACCORDANCE WITH THE LOCAL AND/OR STATE (IF APPLICABLE) BUILDING <br />CODES, NATIONAL ELECTRIC CODE, ADA-ADAAG AND OTHER ADOPTED ACCESSIBILITY STANDARDS, OSHA, AND ALL APPLICABLE CODES, REGULATIONS, <br />ORDINANCES AND AUTHORITIES HAVING JURISDICTION (AHJ). <br />2. PROVISIONS REGARDING THE USE OF GAS AND DIESEL EQUIPMENT WITHIN AN ENCLOSED BUILDING, FORMERLY INCLUDED IN THIS PARAGRAPH, ARE NOW <br />INCLUDED IN SECTION 01351 - REGULATORY COMPLIANCE <br />3. PROVISIONS REGARDING CORDS FOR ELECTRICAL EQUIPMENT AND ROUTING OF EQUIPMENT CORDS AND HOSES, FORMERLY INCLUDED IN THIS <br />PARAGRAPH, ARE NOW INCLUDED IN SECTION 01351 - REGULATORY COMPLIANCE <br />4. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE <br />FAILURE TO REVIEW THESE DOCUMENTS DOES NOT RELIEVE THE SUBCONTRACTOR OF ANY RESPONSIBILITY FOR PERFORMING WORK PROPERLY. NO <br />ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS <br />KNOWLEDGE. <br />5. THE EXISTING BUILDING SHALL BE PROTECTED FROM MOISTURE, DUST AND DEBRIS. INSTALL DUST PARTITIONS OR DRAPES AS REQUIRED AND/OR AS <br />DIRECTED BY WALMART CONSTRUCTION MANAGER TO KEEP DUST AND MOISTURE FROM THE OPERATING AREAS OF THE STORE. <br />6. ANY DAMAGE TO WALMART'S PROPERTY, WHICH OCCURS DURING THE PROCESS OF CONSTRUCTION SHALL BE REPAIRED/REPLACED AT NO ADDITIONAL <br />COST TO WALMART; THIS INCLUDES ALL MERCHANDISE. CONTRACTOR SHALL PAY THE COST FOR ALL DAMAGED MERCHANDISE. <br />7. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING BUILDING SECURITY AT ALL TIMES. THIS INCLUDES KEEPING THE BUILDING SECURE <br />FROM PERSONS, ENVIRONMENTAL ELEMENTS OR HAZARDS. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THE INTEGRITY OF ALL EXISTING <br />SECURITY SYSTEMS. THE CONTRACTOR SHALL OBTAIN PERMISSION FROM THE STORE MANAGER PRIOR TO THE MODIFICATION OF ANY EXISTING SECURITY <br />SYSTEM FOR THE OPENING (DEMOLITION) OF ANY EXTERIOR WALL. <br />8. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAN AND FREE OF DEBRIS AND REMOVE ALL TRASH AND DEBRIS FROM THE CONSTRUCTION AREA <br />DAILY. NO FLAMMABLE MATERIALS OR LIQUIDS MAY BE STORED IN THE EXISTING BUILDING OR IN ANY NEW ADDITION. <br />9. REMOVE ANY EXISTING EQUIPMENT, FIXTURES, FURNISHINGS, ACCESSORIES, SERVICES, FINISHES OR SURFACES AS REQUIRED SHOWN OR NOT SHOWN, <br />FOR THE INSTALLATION OF NEW CONSTRUCTION. PROVIDE FURRING FOR CONDUITS AND PIPING, SHOWN OR NOT, AND FINISH OUT FURRING TO MATCH <br />ADJACENT EXISTING FINISHES. <br />10. REPAIR, RE-ROUTE, AND EXTEND ALL SERVICES, PIPING, CONDUIT OF EXISTING ITEMS AND EQUIPMENT AS REQUIRED DURING THE CONSTRUCTION <br />PROCESS TO MAINTAIN NORMAL STORE OPERATIONS AND AS REQUIRED FOR THE INSTALLATION OF NEW CONSTRUCTION. THIS INCLUDES ALL ITEMS <br />SHOWN OR NOT SHOWN ON THE DRAWINGS. RESET EXISTING EQUIPMENT, FIXTURES, FURNISHINGS, ACCESSORIES OR RELATED ITEMS AS REQUIRED FOR <br />PROPER OPERATION. <br />11. WHEN EQUIPMENT, FIXTURES, FURNISHINGS, ACCESSORIES, SERVICES, FINISHES OR SURFACES ARE TEMPORARILY REMOVED OR RELOCATED IN ORDER <br />TO PERFORM WORK, THE CONTRACTOR IS RESPONSIBLE FOR RETURNING THEM TO THEIR ORIGINAL POSITION, RECONNECTION OF SERVICES AND <br />APPROPRIATE MEANS OF ATTACHMENT UNLESS SPECIFICALLY DIRECTED TO DO OTHERWISE. <br />12. WHERE EXISTING FINISHES ARE TO REMAIN, CLEAN, REPAIR, PATCH AND REPAINT AS NECESSARY TO BLEND IN WITH ADJACENT WORK. COORDINATE WITH <br />WALMART CONSTRUCTION MANAGER. <br />13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY ORDERING OF MATERIALS TO PROHIBIT DELAYS OF THE CONSTRUCTION SCHEDULE OF THIS <br />PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE DELIVERY OF MATERIALS IN A TIMELY MANNER. <br />14. IT IS IMPERATIVE THAT THE ROOF FRAMING, DECKING AND ROOFING SYSTEM BE COMPLETED IMMEDIATELY UPON THE DEMOLITION OF THE EXTERIOR WALL <br />TO ELIMINATE POTENTIAL WATER DAMAGE OR MOISTURE INFILTRATION. THE CONTRACTOR SHALL KEEP THE BUILDING WATERTIGHT AT ALL TIMES. <br />15. THE GENERAL CONTRACTOR SHALL RESPOND TO ALL REQUIREMENTS OF THE STRUCTURAL ENGINEER/ARCHITECT FOR VERIFICATIONS, RESPONSES, AND <br />SUBMISSIONS. <br />16. IF MODIFICATION TO SPRINKLER SYSTEM IS REQUIRED THE GENERAL CONTRACTOR SHALL HIRE A LICENSED SPRINKLER CONTRACTOR. CONTRACTOR TO <br />SUBMIT SIGNED AND SEALED SPRINKLER DRAWINGS FOR APPROVAL PRIOR TO ANY ALTERATION OF THE AUTOMATIC SPRINKLER SYSTEM. WORK TO BE <br />DONE UNDER SEPARATE PERMIT. <br />17. ALL ADJACENT BUILDINGS (IF APPLICABLE) SHALL REMAIN IN SERVICE DURING DEMOLITION/CONSTRUCTION. <br />18. MUD AND DEBRIS TRACKED ONTO OWNER PAVING OR CITY STREETS TO BE CLEANED IMMEDIATELY. <br />19. BUILDING COMPONENTS AFFECTED BY THE SCOPE OF WORK AND ALLOWED TO REMAIN SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR <br />CREATING DAMAGE OF ANY KIND IN THE FUTURE. <br />DEMOLITION REQUIREMENTS: <br />1. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER AND IN STRICT ACCORDANCE WITH OSHA REGULATIONS. <br />2. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED TO, THE DEMOLITION AND REMOVAL OF <br />WALLS, DOORS, FIXTURES, PLUMBING, PAVING, MECHANICAL AND ELECTRICAL ITEMS INCLUDING CONDUITS AND DUCTWORK AS SHOWN ON DRAWING OR <br />AS REQUIRED FOR THE INSTALLATION OF THE NEW WORK FOR A COMPLETE JOB. <br />3. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A MINIMUM OF 8" BELOW FINISH FLOOR OR A MINIMUM OF 6" ABOVE FINISH CEILING. <br />4. WHEN REMOVING EXISTING STRUCTURAL ITEMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING, BRACING AND SUPPORT <br />SYSTEMS TO KEEP THE EXISTING STRUCTURE INTACT AND IN A SAFE CONDITION. REFER TO SECTIONS 02023 AND 02251. <br />5. THE CONTRACTOR MAY NOT REMOVE THE BLOCK WALL IN A PROPOSED OPENING PRIOR TO THE ROOFING SYSTEM OVER THE NEW ADDITION BEING MADE <br />WATERTIGHT. COORDINATE WITH THE WALMART CONSTRUCTION MANAGER AND THE STORE MANAGER TO SCHEDULE FOR DEMOLITION FOR NEW <br />OPENINGS. <br />6. THE CONTRACTOR SHALL REMOVE ANY BUILDING SIGNAGE THAT INTERFERES WITH THE BUILDING ADDITION. WALMART WILL REINSTALL SIGNAGE OR ADD <br />NEW SIGNAGE AT COMPLETION OF ADDITION. <br />7. NOTES INDICATING DEMOLITION WORK ARE NOT CONFINED SOLELY TO THE DEMOLITION PLANS. THE GENERAL CONTRACTOR SHALL REVIEW ALL <br />CONSTRUCTION DOCUMENTS, INCLUSIVE OF SCHEDULES AND SPECIFICATIONS, TO DETERMINE FULL EXTENT OF DEMOLITION WORK. <br />SIGNAGE LEGEND <br />ABBREVIATION LEGEND <br />GENERAL ABBREVIATIONS <br />ABBR <br />DEFINITION <br />AB <br />ANCHOR BOLT <br />ACI <br />AMERICAN CONCRETE INSTITUTE <br />ACRYL <br />ACRYLIC <br />ADA <br />AMERICANS WITH DISABILITIES ACT <br />ADJ <br />ADJACENT <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />AISC <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />ARCH <br />ARCHITECTURAL <br />ASTM <br />AMERICAN SOCIETY OF TESTING AND MATERIALS <br />AWS <br />AMERICAN WELDING SOCIETY <br />COL I COLUMN 1 <br />DIA <br />DIAMETER <br />DSD <br />DIRECTS SHIPPING DELIVERY <br />EAS <br />ELECTRONIC ARTICLE SURVEILLANCE <br />EDC <br />ELECTRICAL DISTRIBUTION CENTER <br />EIFS <br />EXTERIOR INSULATION AND FINISH SYSTEM <br />EF <br />EXHAUST FAN <br />EJ <br />EXPANSION JOINT <br />EL <br />ELEVATION <br />ELEC <br />ELECTRICAL <br />EQ <br />EQUAL <br />ETR <br />EXISTING TO REMAIN <br />EW <br />EACH WAY <br />EWC <br />ELECTRIC WATER COOLER <br />FDN <br />FOUNDATION <br />FF <br />FINISHED FLOOR <br />FRP <br />FIBER REINFORCED PLASTIC <br />FS <br />FAR SIDE <br />FTG <br />FOOTING <br />FV <br />FIELD VERIFY <br />GA <br />GAUGE <br />GC <br />GENERAL CONTRACTOR <br />GM <br />GENERAL MERCHANDISE <br />GR <br />GROCERY <br />GYP BD <br />GYPSUM BOARD <br />HC <br />I HANDICAP <br />HDTV <br />I HIGH DEFINITION TELEVISION <br />HSS HOLLOW STRUCTURAL SECTION <br />HT HEIGHT <br />INFO INFORMATION <br />ISO ISOLATION <br />IRE JOIST BEARING ELEVATION <br />KSI <br />I KIPS PER SQUARE INCH <br />L <br />LENGTH <br />LB <br />POUNDS <br />LLH <br />LONG LEG HORIZONTAL <br />LLV <br />LONG LEG VERTICAL <br />MAU <br />MECHANICAL AIR UNIT <br />ME <br />MASONRY ELEVATION <br />MECH <br />MECHANICAL <br />MEP <br />MECHANICAL ELECTRICAL PLUMBING <br />MFR <br />MANUFACTURER <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MO <br />MASONRY OPENING <br />MTL <br />METAL <br />NIC <br />NOT IN CONTRACT <br />NTS <br />NOT TO SCALE <br />Oc <br />ON CENTER <br />OD <br />OUTSIDE DIAMETER <br />OH <br />OPPOSITE HAND <br />PAF <br />POWDER ACTUATED FASTENER <br />PCF <br />POUNDS PER CUBIC FOOT <br />PFC <br />PAINT, FIX, CLEAN <br />PL <br />PLATE <br />PLAM <br />PLASTIC LAMINATE <br />PLAST <br />PLASTIC <br />PLF <br />POUNDS PER LINEAR FOOT <br />PMEJ <br />PREMOLDED EXPANSION JOINT <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />PVC <br />POLYVINYL CHLORIDE <br />QTY <br />QUANTITY <br />RC <br />REFRIGERATION CONTRACTOR <br />REF <br />REFER TO <br />REINF <br />REINFORCING <br />REQD <br />REQUIRED <br />REV <br />REVERSE <br />/ <br />SIGN <br />L _ 0 <br />0 <br />S <br />SIGN, REF NOTE 3. <br />FF <br />1. REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT THE <br />FOLLOWING LOCATIONS: <br />A. ACCESSIBLE ENTRANCES WHERE NOT ALL ENTRANCES ARE ACCESSIBLE <br />B. ACCESSIBLE ROOMS WHERE MULTIPLE SINGLE -USER TOILETS ARE CLUSTERED AT A SINGLE LOCATION <br />C. ACCESSIBLE CHECK-OUT AISLES WHERE NOT ALL AISLES ARE ACCESSIBLE. THE SIGN, WHERE PROVIDED, SHALL BE ABOVE <br />THE CHECK-OUT AISLE IN THE SAME LOCATION AS THE CHECK-OUT AISLE NUMBER OR TYPE OF CHECK-OUT <br />IDENTIFICATION <br />D. UNISEX TOILET AND BATHING ROOMS <br />SCHED_ <br />SCHEDULE <br />SDI <br />STEEL DECK INSTITUTE <br />SIM <br />SIMILAR <br />SJI <br />STEEL JOIST INSTITUTE <br />SPECS <br />SPECIFICATIONS <br />SS <br />STAINLESS STEEL <br />STD <br />STANDARD <br />STRUC <br />STRUCTURAL <br />T&B <br />TOP AND BOTTOM <br />TEMP <br />TEMPERED <br />THK <br />THICKNESS <br />TO <br />TOP OF <br />TOC/TC <br />TOP OF CONCRETE <br />TOF <br />TOP OF FOOTING <br />TOGB <br />TOP OF GRADE BEAM <br />TOM <br />TOP OF MASONRY <br />E. ACCESSIBLE DRESSING, FITTING AND LOCKER ROOMS WHERE NOT ALL SUCH ROOMS ARE ACCESSIBLE <br />TOP/TP <br />TOP OF PAVING <br />TOS <br />TOP OF STEEL <br />2. DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEAREST LIKE ACCESSIBLE ELEMENT SHALL BE PROVIDED AT THE <br />FOLLOWING LOCATIONS. THESE DIRECTIONAL SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY: <br />A. AT EACH SEPARATE -SEX TOILET INDICATING THE LOCATION OF THE NEAREST UNISEX TOILET <br />TRANS <br />TRANSVERSE <br />TYP <br />TYPICAL <br />UNO <br />UNLESS NOTED OTHERWISE <br />VCPFC <br />VISION CENTER PAINT FIX CLEAN <br />3. TACTILE SIGNAGE SHALL BE LOCATED 48 INCHES (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, <br />MEASURED FROM THE BASE OF THE LOWEST TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE THE FINISH <br />FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER. WHERE A TACTILE <br />SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE <br />VERT <br />VERTICAL <br />W <br />WIDTH <br />WM <br />WALMART <br />SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A <br />TACTILE SIGN IS AT DOUBLE DOORS WITHOF <br />ED LEAFS, THEITHERSIDE TOF THE <br />BEDHE <br />DEFINITION LEGEND <br />THERE S NO WALL SPACE ATOTHE LATCH SIDE OF AACTIVE <br />SINGLE DOOR OR AT TSHALL <br />RIGHT HAND DOOR WHDERE R G TTO <br />DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS <br />SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES (455 MM) MINIMUM BY 18 INCHES (455 MM) MINIMUM, <br />CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED FINAL MERCHANDISE PLAN - FINALIZED MERCHANDISE PRINT FROM WM <br />POSITION AND 45 DEGREE OPEN POSITION. EXCEPTION: SIGNS WITH TACTILE CHARACTERS SHALL BE PERMITTED ON THE ALSO REFERRED TO AS THE DEAL BOX COPY <br />PUSH SIDE OF DOORS WITH CLOSERS AND WITHOUT HOLD -OPEN DEVICES. <br />4. CHARACTER AND SYMBOLS OF SIGNS SHALL BE IN CONTRAST WITH THEIR BACKGROUND AND SHALL BE EGGSHELL, MATTE, OR <br />OTHER NON -GLARE MATERIALS OR FINISHES. <br />5. ACCESSIBLE SIGNAGE SHALL USE GRADE 2 BRAILLE AND MUST COMPLY WITH ICC A117.1 SECTION 703.4 OR ADA SECTION 703.3. <br />ZEPHYRHILLS, <br />FL <br />7631 GAIL BLVD, ZEPHYRHILLS, FL 33541 <br />GA PROJECT No: 2200532 <br />GIATTINA AYCOCK <br />ARCHITECTURE STUDIO INC. <br />2625 5th Avenue North, Building C <br />• Bessemer, AL 35020 <br />P: 205.933.9060 <br />GASTUDIO.COM <br />1925 Prospect Ave. <br />A:V <br />Orlando, FL 32814 <br />P (407) 661-9100 <br />F (407) 661-9101 <br />Architects Engineers Planners <br />F1.1W1C.Pw Cmr,i 4MCW526 <br />STAMP: <br />OF <br />koBERT S. D,q , '' 9 <br />ON 14 7 <br />h'ED ARG <br />ISSUE SCHEDULE: <br />NOTES & LEGEND <br />CURRENT DRAWING SET: <br />11 /09/20 <br />A020 <br />C:\Users\Sabrina.Frankenstein\Documents\0706 ZEPHYRHILLS FL 192 R ARCH V20 Sabrina. Frankenstein. rvt 11/24/2020 4:51:04 PM <br />