<br />ELECTRICAL
<br />04242o
<br />SYMBOLS
<br />LEGEND
<br />(SYMBOLS APPLY
<br />ONLY WHEN USED ON DRAWINGS)
<br />SYMBOL
<br />DESCRIPTION
<br />ko= 0 0
<br />LIGHT FIXTURE
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />O 1
<br />LIGHT FIXTURE
<br />LIGHT FIXTURE,
<br />NIGHT LIGHT
<br />Pq
<br />VOLUMETRIC LIGHT FIXTURE
<br />TRACK LIGHTING
<br />/®
<br />EXIT FIXTURE
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />/ Boa
<br />EMERGENCY LIGHT
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />m /
<br />EMERGENCY LIGHT REMOTE HEADS
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />SINGLE POLE SWITCH
<br />$3
<br />3-WAY SWITCH
<br />$4
<br />4-WRY SWITCH
<br />$K
<br />KEYED SWITCH
<br />$D
<br />DIMMER SWITCH
<br />$VS
<br />VARIABLE SPEED SWITCH
<br />$M
<br />MANUAL MOTOR SWITCH
<br />S
<br />SINGLE POLE OCCUPANCY
<br />SENSOR SWITCH
<br />$OS2
<br />DOUBLE POLE OCCUPANCY
<br />SENSOR SWITCH
<br />((( OSQ)
<br />CEILING MOUNTED OCCUPANCY
<br />SENSOR SWITCH, FOUR -DIRECTION
<br />SENSING
<br />OS
<br />WALL MOUNTED OCCUPANCY SENSOR
<br />SWITCH, ONE -DIRECTION SENSING
<br />RECEPTACLE, DUPLEX
<br />RECEPTACLE, DUPLEX,
<br />MOUNTED HORIZONTALLY
<br />RECEPTACLE, GFI
<br />RECEPTACLE, DUPLEX FLUSH FLOOR
<br />RECEPTACLE, DUPLEX ISOLATED
<br />GROUND FLUSH FLOOR
<br />if if
<br />RECEPTACLE, DOUBLE DUPLEX
<br />}
<br />ll
<br />RECEPTACLE, DUPLEX
<br />ISOLATED GROUND
<br />RECEPTACLE, DOUBLE DUPLEX,
<br />ISOLATED GROUND
<br />RECEPTACLE, SIMPLEX TWIST LOCK,
<br />L5-15R, LINO
<br />RECEPTACLE, SIMPLEX TWIST LOCK,
<br />ISOLATED GROUND, L5-15R, LINO
<br />RECEPTACLE, DUPLEX TWIST LOCK,
<br />L5-15R, LINO
<br />RECEPTACLE, DUPLEX TWIST LOCK,
<br />ISOLATED GROUND, L5-15R, LINO
<br />RECEPTACLE, SPECIAL
<br />RECEPTACLE, SIMPLEX
<br />RECEPTACLE, PLUG -MOLD
<br />O
<br />JUNCTION BOX
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />O
<br />THERMOSTAT
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />O
<br />ALARM JUNCTION BOX,
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />®
<br />ALARM JUNCTION BOX,
<br />FOR REMOTE TEST/RESET
<br />(WALL MOUNTED/CEILING MOUNTED)
<br />SO
<br />SMOKE DETECTOR
<br />Eh
<br />NON -FUSED DISCONNECT
<br />FUSED DISCONNECT
<br />EQUIPMENT CONNECTION POINT
<br />(PROVIDED WITH EQUIPMENT)
<br />CIRCUIT, CONCEALED IN WALLS OR
<br />CEILING, E INDICATES EXISTING WIRING
<br />CIRCUIT, CONCEALED IN SLAB FLOOR,
<br />E INDICATES EXISTING WIRING
<br />CIRCUIT, EXPOSED,
<br />E INDICATES EXISTING WIRING
<br />-�------------
<br />LOW VOLTAGE WIRING
<br />f--I
<br />CONDUIT SLEEVE
<br />1�
<br />FLUSH MOUNTED PANELBOARD
<br />SURFACE MOUNTED PANELBOARD
<br />-
<br />TELEPHONE / DATA BOX FOR ISD
<br />LOW VOLTAGE CABLE
<br />BOX FOR OTHER
<br />a
<br />TELEPHONE, FLUSH FLOOR
<br />O
<br />MOTOR
<br />z
<br />TELEPOWER POLE
<br />PUSH BUTTON
<br />�B
<br />BUZZER
<br />SS
<br />SAIL SWITCH
<br />JUNCTION BOX
<br />( KI
<br />_
<br />HORN/STROBE
<br />DH
<br />DOOR HOLD OPEN
<br />ET61
<br />TIME CLOCK
<br />0
<br />7
<br />ABBREVIATIONS
<br />a, b, c LOWER CASE LETTERS INDICATE
<br />SWITCHING CONFIGURATION
<br />AFF ABOVE FINISHED FLOOR
<br />AFG ABOVE FINISHf D GRADE
<br />C CONDUIT
<br />CCT CIRCUIT
<br />CIF CEILING FAN
<br />CW CASH WRAP
<br />EC ELECTRICAL CONTRACTOR
<br />EF EXHAUST FAN
<br />ETR EXISTING TO REMAIN
<br />EWC ELECTRIC WATER COOLER
<br />G GROUND
<br />GC GENERAL CONTRACTOR
<br />GFEP GROUND FAULT EQUIPMENT PROTECTION
<br />GFI GROUND FAULT CIRCUIT INTERRUPTER
<br />HD HAND DRYER
<br />IG ISOLATED GROUND
<br />LCU LIGHTING CONTROL UNIT
<br />NIL NIGHT LIGHT
<br />NTS NOT TO SCALE
<br />REC REFRIGERATION ELECTRICAL CONTRACTOR
<br />RC REFRIGERATION CONTRACTOR
<br />RH RADIANT HEATER
<br />SC SECURITY CAMERA
<br />TR TAMPER RESISTANT
<br />TYP TYPICAL
<br />UH UNIT HEATER
<br />LINO UNLESS NOTED OTHERWISE
<br />WH WATER HEATER
<br />WP WEATHER PROOF
<br />WR WEATHER RESISTANT
<br />COORDINATE ALL CHANGES TO EXISTING ELECTRICAL SERVICE
<br />AND METERING WITH UTILITY COMPANY.
<br />STORE ADDRESS: WALMART GENERAL REMODEL
<br />7631 GALL BLVD
<br />ZEPHYRHILLS, FL 33541
<br />UTILITY COMPANY: DUKE ENERGY
<br />CONTACT: ERIKA MCCULLOUGH
<br />PHONE: (727) 372-5118
<br />F--- ---i EXISTING
<br />J UTILITY TRANSFORMER
<br />480Y/277V, 30, 4W SEC
<br />33,910
<br />0
<br />EXISTING SUBMETERING: IF IT IS NECESSARY TO REMOVE
<br />A METER, RTU SERVER, CT OR DISRUPT THE
<br />COMMUNICATION OF THE SUBMETERING SYSTEM IN ANY
<br />WAY, THE CONTRACTOR IS RESPONSIBLE TO RESTORE
<br />THE SUBMETERING SYSTEM TO THE SAME LEVEL OF
<br />OPERATION THAT EXISTED PRIOR TO THE WORK BEING
<br />INITIATED. THE EXISTENCE AND FUNCTIONALITY OF THE
<br />SUBMETERING SYSTEM SHALL BE VERIFIED BY CALLING
<br />WALMART BUILDING PERFORMANCE TEAM AT 479-204-0432
<br />BETWEEN THE HOURS OF 7 AM AND 5 PM CENTRAL TIME.
<br />REPRESENTS THE AVAILABLE FAULT
<br />CURRENT IN RMS SYMMETRICAL AMPS
<br />AT THE RESPECTIVE TRANSFORMER,
<br /><\/i
<br />PANELBOARD, OR EQUIPMENT.
<br />FAULT CURRENT CALCULATIONS ARE
<br />BASED ON AVAILABLE CURRENT OF 33,910
<br />AMPS AT SECONDARY TERMINALS OF THE
<br />UTILITY TRANSFORMER AS PROVIDED BY
<br />THE UTILITY COMPANY.
<br />EXISTING DISTRIBUTION SYSTEM IS
<br />SERIES RATED. E.C. SHALL PROVIDE
<br />CIRCUIT BREAKER(S) THAT WILL
<br />MAINTAIN EXISTING MANUFACTURER'S
<br />U.L. LISTED SERIES RATED SYSTEM.
<br />MAXIMUM DEMAND PER UTILITY
<br />COMPANY FOR THE PAST 12 MONTHS
<br />WAS 956KW TAKEN IN OCTOBER 2019.
<br />33,515 MSB1 ELEC ROOM 1 EXISTING
<br />I I
<br />4000 AMPS 480Y/277V 30 4W
<br />800A
<br />Q 3P
<br />EXISTING
<br />PNLBD
<br />30,220 H162
<br />i
<br />480Y/277V
<br />300A
<br />3P(NEW)
<br />)
<br />FURNISH AND INSTALL LOCKING
<br />HARDWARE ON BREAKER AND
<br />670 FT
<br />ELECTRICAL ROOM 1
<br />LOCK IN THE OFF POSITION
<br />-
<br />-
<br />AL: (4) 500 KCMIL, (1) #2G, 4"C
<br />I 3,895 I
<br />I I
<br />OVERHEAD FEEDER THRU BUILDING TO CLINIC
<br />MED CLINIC ELECTRICAL POWER
<br />INTERFACE PULLBOX. MOUNT TYPE
<br />OF PULLBOX BELOW ROOF JOIST.
<br />i I
<br />SALES
<br />PARTIAL ONE -LINE DIAGRAM
<br />NTS
<br />5
<br />0
<br />KI
<br />BUS AMPS: 800A
<br />MAINS SIZE/ TYPE: MLO
<br />VOLTS/PHASE: 480Y/277 V 3PH, 4W
<br />SECTION:1
<br />PANELBOARD:
<br />H1 B2
<br />AIC RATING:
<br />SERVES:
<br />MOUNTING:
<br />LOCATION:
<br />(EXISTING)
<br />44,000
<br />480V DISTRIBUTION
<br />SURFACE
<br />EDC1
<br />EQUIPMENT GROUND BUS
<br />CKT N0.
<br />DESCRIPTION
<br />WIRE
<br />BKR
<br />AMP
<br />P
<br />A
<br />B
<br />C
<br />P
<br />BKR
<br />AMP
<br />WIRE
<br />DESCRIPTION
<br />CKT N0.
<br />1
<br />PANELBOARD H3A (13)
<br />-
<br />500 A
<br />3
<br />100000 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />DEDICATED SPACE
<br />2
<br />3
<br />100000 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />DEDICATED SPACE
<br />4
<br />5
<br />100000 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />DEDICATED SPACE
<br />6
<br />7
<br />PANELBOARD H3B (13)
<br />-
<br />400 A
<br />3
<br />82000 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />DEDICATED SPACE
<br />8
<br />9
<br />82000 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />DEDICATED SPACE
<br />10
<br />11
<br />82000 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />DEDICATED SPACE
<br />12
<br />13
<br />FUTURE CLINIC (2,8)
<br />-
<br />300 A
<br />3
<br />57365 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />14
<br />15
<br />57365 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />16
<br />17
<br />57365 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />18
<br />19
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />--
<br />-
<br />SPACE
<br />20
<br />21
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />--
<br />SPACE
<br />22
<br />23
<br />SPACE
<br />--
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />24
<br />25
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />26
<br />27
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />28
<br />29
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />30
<br />31
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />32
<br />33
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />34
<br />35
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />36
<br />37
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />38
<br />39
<br />SPACE
<br />-
<br />-
<br />-
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />SPACE
<br />40
<br />41 ISPACE
<br />1
<br />0 VA
<br />0 VA
<br />-
<br />-
<br />-
<br />ISPACE
<br />42
<br />Total Load:
<br />239365 VA
<br />239365 VA
<br />239365 VA
<br />Total Amps:
<br />864 A
<br />864 A
<br />864 A
<br />TOTAL DEMAND
<br />Total Conn. Load:
<br />718095 VA
<br />Total Est. Demand:
<br />646286 VA
<br />Total Conn.:
<br />864 A
<br />Total Est. Demand:
<br />778 A
<br />PANELBOARD NOTES:
<br />FED VIA 800A/3P BREAKER IN MSB
<br />7 I (8 (\9) (10) (11)(12)('13) (14) �15)
<br />(1) 2 �3 I (4 % (5 i (6� �.
<br />! I I I I I I I I I I I I I
<br />I
<br />LH
<br />MSB AND H1B2 LOCATED IN EDC1
<br />� � I
<br />LG
<br />I I I I I I I I I I I I I I I
<br />I
<br />(D MED CLINIC ELECTRICAL POWER INTERFACE
<br />PULLBOX AND (2)2" EMT SLEEVES FOR
<br />DATA/COMM WITH THREADED BUSHINGS.
<br />ROUTE POWER CONDUIT AND CABLE ALONG
<br />i ROOF JOIST. TAP ENDS OF CABLE AND '
<br />CONDUCTORS IN PULLBOX. INSTALL EMPTY 4"C 2
<br />TO 11 FT HEIGHT AT OPENING IN STORE WALL.
<br />�\ 24X24X12 ' I
<br />\ '
<br />I I
<br />H3P LOCATED IN EDC3'
<br />AY- 1- _ -�- -� - r - 1 -1 -- rt
<br />KEY PLAN
<br />NTS
<br />2
<br />1
<br />PANELBOARD NOTES ()
<br />GENERAL NOTES
<br />2.2e.20
<br />08.28.20
<br />1. TERMINATE GROUND ON ISOLATED GROUND BUS.
<br />1. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND LABOR,
<br />FOR A COMPLETE INSTALLATION IN ALL RESPECTS, READY FOR
<br />2. INSTALL LOCKING DEVICE (LOCK -OFF FOR
<br />INTENDED USE AND IN STRICT ACCORDANCE WITH NEC, NESC,
<br />MAINTENANCE). LOCKING DEVICE SHALL BE UL
<br />STATE, AND LOCAL CODES, AND MANUFACTURER'S
<br />LISTED. MANUFACTURER SHALL MATCH EXISTING
<br />RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS.
<br />PANELBOARD MANUFACTURER.
<br />A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE
<br />3. INSTALL LOCKING DEVICE (LOCK -ON FOR CRITICAL
<br />ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS.
<br />LOAD).
<br />B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE.
<br />C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE
<br />4. GFI BREAKER FOR PERSONNEL PROTECTION (5MA).
<br />OPERATIONS. COORDINATE ALL DISRUPTIONS WITH WALMART
<br />CONSTRUCTION MANAGER AND STORE MANAGER.
<br />5. GFI BREAKER FOR EQUIPMENT PROTECTION (30MA).
<br />D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESS
<br />BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED
<br />6. CONDUCTOR SIZE HAS BEEN INCREASED FOR
<br />BOXES OR BOX EXTENDERS WHERE REQUIRED.
<br />VOLTAGE DROP. SIZE EQUIPMENT GROUNDING
<br />E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED
<br />CONDUCTOR PROPORTIONATELY PER NEC.
<br />PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS
<br />PROPERLY COVERED ANDTHAT ALL TRIM IS IN GOOD
<br />7. REFER TO ONE -LINE DIAGRAM FOR AVAILABLE FAULT
<br />CONDITION, ALLOWING NO ACCESS TO LIVE PARTS.
<br />CURRENT FOR INTERRUPT RATINGS.
<br />2. PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS:
<br />8. REFER TO ONE -LINE DIAGRAMS FOR WIRE SIZES.
<br />A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE
<br />STOPPING.
<br />9. FACTORY WIRED TO LOAD.
<br />B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL.
<br />C. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM
<br />10. BREAKER SHALL BE HIGH MAGNETIC TYPE.
<br />SEALANT.
<br />D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR
<br />11. BREAKER REMOVAL - FIELD VERIFY CIRCUIT
<br />SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED DEVICES,
<br />BREAKER IS NOT SERVING AN EXISTING LOAD. IF NO
<br />FIXTURES, ENCLOSURES, AND RACEWAY PENETRATIONS.
<br />EXISTING LOAD, REMOVE CIRCUIT BREAKER AND
<br />PROVIDE FILLER PLATE. IF BREAKER IS SERVING A
<br />3. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR (SIZE
<br />LOAD, IDENTIFY LOAD SERVED. UPDATE CIRCUIT
<br />PER NEC) IN PVC TYPE CONDUIT, POWER AND LIGHTING CIRCUITS,
<br />IDENTIFICATION SCHEDULE AS "SPACE" OR INDICATE
<br />ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT
<br />LOAD SERVED.
<br />SHALL BE SIZED PER NEC BASED ON THWN 600 VOLT COPPER
<br />SINGLE CONDUCTORS, PLUS THE EQUIPMENT GROUNDING
<br />12. DUAL TAP SOLENOID OPERATED BREAKER. CONNECT
<br />CONDUCTOR,
<br />EMERGENCY/NIGHT LIGHTING TO UNSWITCHED
<br />TERMINATION.
<br />4. WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM FINISHED
<br />FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED OTHERWISE ON
<br />13. EXISTING CIRCUIT AND/OR CIRCUIT BREAKER.
<br />PLANS. COORDINATE THE STANDARD MOUNTING HEIGHTS WITH
<br />MASONRY:
<br />14. ROUTE CIRCUIT THROUGH CONTACTOR.
<br />A. SWITCHES +44"
<br />B. RECEPTACLES +20"
<br />15. PROVIDE INTERLOCK WIRING WITH EXHAUST HOOD
<br />C. VOICE/DATA +20"
<br />ANSUL SYSTEM.
<br />5. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN
<br />16. RELOCATED CIRCUIT FROM EXISTING PANELBOARD.
<br />CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS.
<br />17. PROVIDE BLANK CIRCUIT BREAKER FILLER PLATE
<br />6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN UPDATED AND
<br />FOR EXPOSED SPACE IN PANELBOARD.
<br />COMPLETE TYPEWRITTEN CIRCUIT IDENTIFICATION SCHEDULE FOR
<br />EVERY PANELBOARD AFFECTED BY THIS PROJECT.
<br />18. PROVIDE U.L. LISTED OVERCURRENT DEVICE TO
<br />COORDINATE AND MAINTAIN MANUFACTURER'S
<br />7. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN EXISTING
<br />SERIES RATED SYSTEM.
<br />PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE TYPE
<br />AND AIC RATING OF EXISTING OVERCURRENT PROTECTIVE
<br />19. EXISTING CIRCUIT BREAKER TO REMAIN. VERIFY
<br />DEVICES.
<br />CONDITION OF CIRCUIT BREAKER TO ENSURE THAT IT
<br />IS OPERATIONAL AND MEETS ALL U.L. RATINGS.
<br />8. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG
<br />UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A BRANCH
<br />20. ROUTE CIRCUIT THROUGH EXISTING LCU CABINET
<br />CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 AWG WIRE
<br />UTILIZING EXISTING RELAY AND CONTROLS. UPDATE
<br />SHALL BE USED FOR THE FINAL CONNECTION (15-FT MAXIMUM).
<br />LCU IDENTIFICATION SCHEDULE WITH LOAD
<br />IDENTIFICATION.
<br />9. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND
<br />DERATE CURRENT CARRYING CONDUCTORS PER NEC.
<br />21. SOLENOID OPERATED CIRCUIT BREAKER. REFER TO
<br />ENERGY MANAGEMENT PLANS FOR CIRCUIT
<br />10. PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH
<br />BREAKER CONTROL.
<br />CIRCUITS PER NEC REQUIREMENTS.
<br />22. EXISTING LOAD - TRACE EXISTING CIRCUIT, IDENTIFY
<br />11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE
<br />LOAD AND UPDATE CIRCUIT IDENTIFICATION
<br />SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE
<br />SCHEDULE FOR LOAD SERVED. IF CIRCUIT IS NOT IN
<br />ONLY THE TOP AND BOTTOM CHORDS FOR SUPPORTING THE
<br />USE, REFER TO PANELBOARD NOTE (11).
<br />ELECTRICAL SYSTEM INSTALLATIONS.
<br />23. ROUTE CIRCUIT THROUGH ENCLOSED GFI BREAKER
<br />12. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE
<br />FOR PERSONNEL PROTECTION (5MA).
<br />SURFACE MOUNTED UNLESS NOTED OTHERWISE. SEAL DEVICES TO
<br />COOLER/FREEZER PANELS WITH SILICONE SEALANT.
<br />24. SPARE - FIELD VERIFY CIRCUIT BREAKER IS NOT
<br />SERVING AN EXISTING LOAD. IF NO EXISTING LOAD,
<br />13. SURFACE MOUNTED CONDUIT ON COOLER/FREEZER PANELS OR IN
<br />PROVIDE LOCK OFF DEVICE TO LOCK SPARE
<br />FOOD PREP AREAS SHALL BE INSTALLED WITH GALVANIZED 1/2"
<br />BREAKER IN THE OFF POSITION. IF BREAKER IS
<br />STANDOFF CONDUIT HANGERS TO ALLOW FOR CLEANING.
<br />SERVING A LOAD, IDENTIFY LOAD SERVED. UPDATE
<br />CIRCUIT IDENTIFICATION SCHEDULE AS "SPARE" OR
<br />14. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM AND
<br />INDICATE LOAD SERVED.
<br />BRANCH CIRCUITS NOTED BY LEGEND SHALL BE INSTALLED UNDER
<br />SLAB. PROVIDE EXTERIOR COATED GRC BENDS ON ALL CONDUIT
<br />25. EXISTING LOAD - TRACE EXISTING CIRCUIT, IDENTIFY
<br />RUNS THAT HAVE 45 DEGREE BENDS OR GREATER. REFER TO
<br />LOAD AND UPDATE CIRCUIT IDENTIFICATION
<br />SPECIFICATION SECTION 16.100 FOR UNDER SLAB.
<br />SCHEDULE FOR LOAD SERVED. IF CIRCUIT IS NOT IN
<br />USE, REFER TO PANELBOARD NOTE (24).
<br />15. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS
<br />AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY
<br />GENERAL NOTES:
<br />LOCAL CODES.
<br />1. NEW OVERCURRENT PROTECTIVE DEVICES PLACE IN
<br />EXISTING PANELBOARDS OR DISTRIBUTION BOARDS
<br />16. EXISTING ELECTRICAL AND ALARM:
<br />SHALL MATCH THE TYPE AND AIC RATING OF
<br />A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS
<br />EXISTING OVERCURRENT PROTECTION DEVICES IN
<br />EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT,
<br />SAID BOARD.
<br />DEVICES, OR LIGHTING TO REMAIN, BUT NOT SHOWN ON
<br />2. E.C. SHALL TRACE ALL ELECTRICAL CIRCUITS FOR
<br />DRAWINGS, PROVIDE LABOR AND MATERIALS TO REWORK
<br />EVERY EXISTING PANELBOARD AFFECTED BY THIS
<br />CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING OPERATION.
<br />PROJECT. IDENTIFY LOADS ON EACH CIRCUIT.
<br />B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT
<br />PROVIDE A COMPLETE TYPEWRITTEN CIRCUIT
<br />EXISTING UNDERGROUND SERVICES (ELECTRICAL, TELEPHONE,
<br />IDENTIFICATION SCHEDULE FOR EVERY AFFECTED
<br />PARKING LOTLIGHTING CIRCUITRY, ETC.) PROVIDE ALL
<br />PANELBOARD.
<br />MATERIALS AND LABOR AS REQUIRED TO REROUTE, SLEEVE,
<br />3. ALL OVERCURRENT DEVICES ARE NEW UNLESS
<br />OR OTHERWISE REWORK THESE SERVICES TO MAINTAIN THEIR
<br />NOTED OTHERWISE.
<br />EXISTING OPERATION.
<br />C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES
<br />DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM
<br />ONE -LINE D IAG RAM LEGEND
<br />AND SECURITY CABLES FROM TAL D SO THAT
<br />SYSTEMS REMAIN OPERATIONAL AT ALIL TIMES.
<br />D. DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE
<br />�.�s.�o
<br />NOTED.
<br />NEW EQUIPMENT
<br />17. EXISTING ELECTRICAL DEMOLITION:
<br />EXISTING EQUIPMENT
<br />A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL
<br />EQUIPMENT, CONDUIT AND CONDUCTORS AS INDICATED ON
<br />- - - - - EQUIPMENT TO BE DEMOLISHED
<br />THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION.
<br />REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES,
<br />RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL
<br />NOTE:
<br />NOT BE REUSED.
<br />ALL OF THE ELECTRICAL DEVICES SHOWN ON THE RISER
<br />B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT,
<br />DIAGRAM ARE EXISTING AND ARE BASED UPON AS -BUILT
<br />CONDUCTORS AND RELATED DEVICES SERVING SALES AREA
<br />DRAWINGS. E.C. SHALL VERIFY THE EXACT EXISTING
<br />GONDOLAS BEING RELOCATED OR REMOVED. EXISTING
<br />CONDITIONS, SIZES AND LOCATIONS OF EQUIPMENT
<br />CONDUIT AND CONDUCTORS MAY BE REUSED FOR NEW POWER
<br />PRIOR TO ROUGH -IN. THIS RISER IS SHOWN FOR
<br />DROPS WHERE SIZE, RATING, AND CONDITION MEET
<br />INFORMATIONAL PURPOSES ONLY AND ANY NEW
<br />REQUIREMENTS INDICATED ON PLANS AND ALL U.L. RATINGS.
<br />DEVICES ARE SHOWN IN BOLD AND ARE NOTED. DURING
<br />REMOVE ALL UNUSED CONDUIT AND CONDUCTORS BACK TO
<br />CONSTRUCTION, THE STORE SHALL STAY OPEN FOR
<br />POINT OF ORIGIN WHENEVER FEASIBLE. IF CIRCUIT IS NOT
<br />BUSINESS. ANY NECESSARY POWER DOWNTIME SHALL
<br />REUSED, REMOVE CIRCUIT BREAKER AND REPLACE WITH
<br />BE SCHEDULED AND APPROVED BY WALMART
<br />FILLER PLATE. EXCEPTION: DISTRIBUTION AND POWER SWITCH
<br />CONSTRUCTION MANAGER.
<br />BREAKERS SHALL BE ETR AS "SPARE". PROVIDE HANDLE LOCK
<br />OFF DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN THE "OFF"
<br />POSITION. UPDATE TYPEWRITTEN CIRCUIT IDENTIFICATION
<br />SCHEDULE AS "SPACE" OR "SPARE".
<br />C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING SPACES
<br />AND OTHER NON-PUBLIC AREAS (I.E., THROUGH STOCKROOM
<br />AREA): CUT WIRING LOOSE AND REMOVE FROM RACEWAY(S),
<br />LEAVING RACEWAY(S) IN PLACE. CONDUIT TO BE ABANDONED IN
<br />WALLS OR FLOORS SHALL BE REMOVED BACK TO FINISHED
<br />SURFACE AND CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH
<br />ADJACENT.
<br />D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE
<br />REMOVED SHALL ALSO BE REMOVED. REMOVE CIRCUIT
<br />BREAKER AND REPLACE WITH FILLER PLATE. EXCEPTION:
<br />DISTRIBUTION AND POWER SWITCH BREAKERS SHALL BE ETR
<br />AS "SPARE". PROVIDE HANDLE LOCK OFF DEVICE TO LOCK
<br />"SPARE" CIRCUIT BREAKER IN THE "OFF" POSITION. UPDATE
<br />TYPEWRITTEN CIRCUIT IDENTIFICATION SCHEDULE AS "SPACE"
<br />OR "SPARE".
<br />E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO
<br />SELECTIVE SITE DEMOLITION SPECIFICATION FOR DISPOSAL OF
<br />LIGHT FIXTURE.
<br />F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK
<br />SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR
<br />CREATING DAMAGE OF ANY KIND IN THE FUTURE.
<br />18. DATA AND PHONE CONDUIT INSTALLATION MILESTONE DATE:
<br />ALL RACEWAY AND CONDUIT SLEEVES FOR DATA AND PHONE
<br />CABLING TO BE INSTALLED 3 WEEKS PRIOR TO CONTRACT
<br />SUBSTANTIAL COMPLETION DATE.
<br />19. ETHERNET CABLE:
<br />A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON PLANS.
<br />PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES AND/OR
<br />ORDINANCES.
<br />B. ETHERNET CABLE IS FURNISHED BY OTHERS.
<br />C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POWER
<br />POLES.
<br />D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS
<br />DIRECTED BY WALMART CONSTRUCTION MANAGER.
<br />EXISTING CONDITIONS WERE TAKEN FROM
<br />ORIGINAL DRAWINGS AND MAY NOT REFLECT
<br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR
<br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS
<br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR
<br />SHALL CAREFULLY COORDINATE NEW WORK AND
<br />DEMOLITION WITH ALL OTHER DISCIPLINES AND
<br />EXISTING CONDITIONS.
<br />EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING
<br />A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND
<br />SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE
<br />TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES
<br />NOT RELIEVE THE RESPONSIBILITY OF PERFORMING
<br />THE WORK PROPERLY. NO ADDITIONAL
<br />COMPENSATION SHALL BE ALLOWED BECAUSE OF
<br />CONDITIONS THAT OCCUR DUE TO FAILURE TO
<br />FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.
<br />ZEPHYRHILLS,
<br />FL
<br />7631 GAIL BLVD, ZEPHYRHILLS, FL 33541
<br />GA PROJECT No: 2200532
<br />GIATTINA AYCOCK
<br />ARCHITECTURE STUDIO INC.
<br />2625 5th Avenue North, Building C
<br />ts
<br />Bessemer, AL 35020
<br />P: 205.933.9060
<br />GASTUDIO.COM
<br />1925 Prospect Ave.
<br />Orlando, FL 32814
<br />P (407) 661-9100
<br />L F (407) 661-9101
<br />CGI G�i & fefBrsvtc www, c�p, coin
<br />Architects Engineers Planners Fl-&C.W .C-11 kN CO 516
<br />STAMP:
<br />PaADEEp
<br />er:
<br />��: • No 769
<br />= yt =
<br />�'.• A 0 F : 444/
<br />11 /06/20
<br />ISSUE SCHEDULE:
<br />if
<br />REVISION REVISION SCHEDULE:
<br />NUM. DESCRIPTION DATE
<br />CURRENT DRAWING SET:
<br />11 /06/20
<br />ISSUE DATE: 11/06/20
<br />DRAWN BY: SR
<br />SHEET:
<br />CLINIC ELECTRICAL
<br />PLANS AND DETAILS
<br />C:\Users\sarah. rassel\Documents\0706-ZEPHYRHILLS-FL-192-R-MEP-V20-sarah. rassel. rvt
<br />CE1