Search
7880 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7880 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:14:39 PM
Creation date
2/25/2025 9:52:20 AM
Metadata
Fields
Template:
Building Plans
Street #
7880
Location
Gall Blvd
Contractor
Henkley Home
Building Plans - Permit #
14509
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d <br />O� LIGHTING PLAN <br />aSCALE: 1/8"=1'-0" <br />FIXTURE SCHEDULE <br />ISYM. <br />I MANUFACTURER <br />I CATALOG NUMBER <br />LAMPS <br />MTG. <br />REMARKS <br />I INPUT WATTAGE <br />A <br />IMETALUX <br />I2GR8 332A-UNV EB81U <br />(3) F32T8/SPP35/ECO <br />RECESSED <br />3 LAMP, 2'X4' TROFFER WITH 0.125" ACRYLIC LENS, <br />86 <br />(ENERGY SAVING LAMPS AND HIGH EFFICIENCY <br />(INSTANT START ELECTRONIC BALLAST, <br />120V. <br />AE <br />I METALUX <br />2GR8 332A-UNV EB81U EMERGENCY 140O LUMEN <br />(3) F32T8/SPP35/ECO <br />! RECESSED <br />SAME AS TYPE 'A" EXCEPT WITH 11OO LUMEN <br />I <br />86 <br />90 MIN, EMERGENCY BATTERY BALLAST. <br />(MINIMUM, <br />120V. <br />I <br />C <br />I <br />SSF232UNVEB81U <br />(2) F32T8/SPP35/ECO <br />SURFACE OR CHAIN <br />2 LAMP 4' STRIP WITH ENERGY SAVING LAMPS, <br />58 <br />IMETALUX <br />HUNG <br />HIGH EFFICIENCY INSTANT START ELECTRONIC BALLAST, <br />I <br />PLASTIC LAMP COVER. <br />II <br />II120VIDE <br />! <br />I C8 <br />IMETALUX <br />TSSF232UNVEB81U <br />I (4) F32T8/SPP35/ECO <br />I SURFACE <br />14 LAMP 8' STRIP WITH ENERGY SAVING LAMS, <br />I 112 <br />HIGH EFFICIENCY INSTANT START ELECTRONIC BALLAST. <br />I <br />I <br />I <br />I <br />1120V. <br />I <br />I C8E <br />I <br />IMETALUX <br />ITSSF232UNVEB8IU-EL <br />I <br />I (4) F32T8/SPP35/ECO <br />I <br />I SURFACE <br />(SAME AS TYPE 'C8' EXCEPT WITH 1100 LUMEN <br />112 <br />MINIMUM, 90 MIN. EMERGENCY BATTERY BALLAST, <br />i <br />I <br />I <br />I <br />I <br />1120V. <br />I <br />S1 <br />I <br />I <br />(1) GSM-AM-400-MH-208-SL-FG <br />I <br />(1) MS-400 <br />I <br />ARM MOUNTED TO POLE <br />HID SINGLE LIGHT FIXTURE WITH TYPE SL <br />458 <br />IMCGRAW <br />I <br />AT 30 FT. AFG <br />(DISTRIBUTION. TENON MOUNT. SEE BELOW FOR <br />II <br />(POLE TYPE. DIST., 120 ARMS, UL WET LISTED, 208V. <br />(POLE <br />IMCGRAW <br />(FOR 'St' <br />I—_�_—___—__ <br />I ON CONCRETE <br />I37'-0' LONG SQUARE TAPERED STEEL POLE <br />I ---------I <br />I <br />I <br />I <br />i <br />I BASE <br />I <br />W <br />I <br />LIGHTING <br />I <br />/ t 2"-91 / SK-91/ 13/ CFL-BCM-M <br />I (1 13W CFL <br />) <br />I WALL MOUNTED <br />(WALL MOUNTED DECORATIVE FIXTURE <br />15 <br />ARM MOUNT B-4 <br />AT 6'-6" TO <br />1120V. <br />BOTTOM OF <br />FIXTURE <br />IILITHONIA X <br />1EDG-1-R-EL-M6 <br />I LED <br />I UNIVERSAL MOUNT <br />(EDGE LIT LED EXIT SIGN. <br />5 <br />BY MFR, <br />I <br />I120V. <br />NOTE: <br />(1) CONTRACTOR SHALL BE REQUIRED TO SUBMIT CALCULATIONS FROM THE POLE MANUFACTURER, SEALED BY A STRUCTURAL <br />ENGINEER LICENSED IN THE STATE OF FLORIDA, TO CERTIFY WIND LOAD CONFORMANCE OF EACH ENTIRE POLE AND <br />FIXTURE ASSEMBLY. <br />r' <br />H N <br />TOGGLE <br />(TYP) <br />TIME CLOCK <br />(INTERMATIC ##ET17 <br />INTERIOR LIGHTING <br />INTERIOR LIGHTING <br />SIGN LIGHTING <br />MI <br />CONTACTOR SCHEDULE <br />CONTACTOR <br />AMP <br />I OF <br />CIRCUITS <br />CONTROLLED <br />DESIGNATION <br />RATING <br />POLES <br />CONTROLLED <br />BY <br />C1 <br />I <br />30 <br />I <br />4 <br />I <br />SWITCH a <br />I <br />IL1-1,5 <br />TC1 ON/TCI OFF <br />C2 <br />I <br />I 30 <br />4 <br />I <br />SWITCH b <br />�1-1-3,9 <br />TC1 ON/TC1 OFF <br />C3 <br />' 30 <br />4 11-1-18,34,42 <br />TC2 ON/TC2 OFF <br />GENERAL NOTE: <br />1. REFER TO DRAWINGS <br />FOR <br />UNCONTROLLED CIRCUIT REQUIREMENTS, <br />SOME CIRCUITS <br />MAY BE PARTIALLY <br />CONTROLLED. <br />MATTRESS FIRM <br />LIGHTING CONTROL DIAGRAM <br />SCALE: NONE <br />NOTES Q <br />1. ROUTE HOMERUN VIA MATTRESS FIRM LIGHTING CONTACTOR(S). REFER TO <br />CONTACTOR SCHEDULE ON THIS SHEET. <br />2. SWITCHES FOR OPEN AREA LIGHTING, REFER TO LIGHTING CONTROL DIAGRAM <br />ON THIS SHEET, <br />3. DIGITAL TIMER SWITCH. <br />4. PROVIDE CEILING MOUNTED OCCUPANCY SENSOR TO CONTROL LIGHTING THIS <br />AREA (LEVITON MODEL ##OSC04—I0W WITH POWER BASE ADAPTER). <br />5, PROVIDE WALL SWITCH OCCUPANCY SENSOR TO CONTROL LIGHTING IN <br />RESTROOMS (LEVITON MODEL ##ODS15—ID). <br />6, EXTEND CIRCUIT TO EXHAUST FAN. EXHAUST FAN TO OPERATE WITH LIGHTING <br />CONTROL. <br />7. ROUTE HOMERUN VIA HOUSE PANEL LIGHTING CONTACTOR(S). <br />8. PROVIDE JUNCTION BOX ABOVE CEILING FOR CONNECTION TO 120/12V <br />TRANSFORMER (FBO) TO POWER DETEX ALARM EXIT DEVICE. COORDINATE <br />LOCATION AND CONNECTION REQUIREMENTS WITH DETEX INSTALLER. <br />GENERAL NOTES <br />1. FIXTURE WHIPS SHALL BE ASSEMBLED WITH 1 /2" FLEXIBLE CONDUIT AND SHALL <br />BE OF SUFFICIENT LENGTH TO ALLOW RELOCATION OF ANY TYPE 'A' OR 'AE' <br />LIGHT FIXTURE A MINIMUM OF ONE TILE IN ANY DIRECTION, <br />2. ALL EXPOSED CONDUIT SHALL BE LOCATED WITHIN JOIST SPACE AREA OR <br />ATTACHED DIRECTLY TO THE JOIST, CONDUIT SHALL NOT BE SUSPENDED FROM <br />STRUCTURE. <br />3. CONTRACTOR SHALL COORDINATE LOCATION AND MOUNTING HEIGHT OF ALL <br />EXTERIOR SOFFIT LIGHTS AND WALLPACKS WITH ARCHITECTURAL DRAWINGS AND <br />DETAIL. <br />4. EXTEND UNCONTROLLED "HOT" CONDUCTOR TO ALL EMERGENCY LIGHTS, EXIT <br />LIGHTS, AND NIGHT LIGHTS. <br />Job Number: 65173 <br />Colwill Engineering <br />Consulting Engineers, Inc. <br />Engineering Business No. 9021 <br />4750 East Adamo Drive Tampa, Florida 33605 <br />Tel: 813-241-2525 Fax: 813-241-2424 <br />© 2013 ALL RIGHTS RESERVED <br />e Tec <br />_I1 n <br />Associates, Inc. AA26001933 <br />Architecture • Planning Interior Design <br />14125 N.W. 80th Ave. Suite 303 <br />Miami Lakes, FI. 33016 <br />T. 786-235-9097 <br />F. 305-362-4420 <br />dtiinfo@dtiarchitect.com <br />www.dtiarchitect.com <br />C0�'y�'�i <br />C�E N S <br />50 6 <br />cc <br />S F <br />C?` <br />Phillip L. C chran, <br />P.E. No.50716 <br />Revisions: <br />Date Description <br />10-21-13 OWNER CHANGES <br />0 <br />a <br />O <br />0 <br />W <br />0 <br />0 <br />a <br />M <br />x <br />w <br />Job Number: <br />12049.01 <br />File name: <br />Issued Date: <br />07.17.13 <br />Drawn by: <br />AS/PK <br />Checked by: <br />DAS <br />11 SHEET NAME I I <br />LIGHTING <br />PLAN <br />SHEET NUMBER <br />E-2.0 <br />-I. li tl16�!II 7R 11wj:WI LLB. rM Aii 1. lll.,❑< a 11 ,I IisY._. ,.1 12.—:1 <br />