My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7880 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7880 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:14:39 PM
Creation date
2/25/2025 9:52:20 AM
Metadata
Fields
Template:
Building Plans
Street #
7880
Location
Gall Blvd
Contractor
Henkley Home
Building Plans - Permit #
14509
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rr <br />r' <br />MECHANICAL PLAN <br />UV SCALE: 1/8"=1'-0" <br />0 <br />m <br />U <br />L0 <br />1p <br />CYi <br />M <br />r <br />C'M <br />0 <br />N <br />M <br />N <br />_o <br />0 <br />M <br />ti <br />L0 <br />co <br />E <br />ii <br />co <br />P <br />co <br />2 <br />M <br />LO <br />ro <br />J <br />KEYED NOTES: 0 <br />1. COORDINATE EXACT LOCATION OF RTU WITH <br />STRUCTURAL PRIOR TO INSTALLATION TO AVOID <br />CONFLICTS WITH DUCT DROPS. <br />MECHANICAL LEGEND <br />SUPPLY DIFFUSER <br />® <br />SMOKE DETECTOR SD <br />RETURN GRILLE <br />CONDENSATE 4-- <br />PIPING COND <br />EXHAUST FAN <br />® <br />THERMOSTAT <br />FLEXIBLE DUCT <br />1" DOOR UNDERCUT <br />FOR MAKE-UP AIR <br />RIGID DUCT <br />SUPPLY AIRFLOW - <br />VOLUME DAMPER <br />rZ:=l <br />RETURN AIRFLOW -��- <br />MECHANICAL GENERAL NOTES <br />1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2010 <br />FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, FLORIDA ENERGY <br />CODE, ALL NFPA REQUIREMENTS AND ALL LOCAL CODES. - <br />2. ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL,STRUCTURAL, <br />MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS. CONTRACTOR SHALL BE <br />REQUIRED TO FURNISH, INSTALL AND CONNECT WITH APPROPRIATE SERVICES <br />ALL ITEMS SHOWN ON THE DRAWING AT NO ADDITIONAL COST TO THE <br />OWNER. <br />3. FURNISH SIX (6) COPIES OF SHOP DRAWINGS OF EQUIPMENT OR <br />FIXTURES FOR APPROVAL PRIOR TO PURCHASING. <br />4. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL HAVE STUDIED <br />AND COMPARED THE CONTRACT DOCUMENTS WITH EXISTING/PROPOSED <br />CONDITIONS AND NOT LATER THAN TEN (10) DAYS PRIOR TO THE BID <br />OPENING SHALL REPORT TO THE ENGINEER ANY ERROR, INCONSISTENCIES <br />OR OMISSIONS IN THE CONTRACT DOCUMENTS. <br />5. TEST AND BALANCE REPORT SHALL BE PROVIDED BY THE MECHANICAL <br />SUBCONTRACTOR WITH A WRITTEN REPORT PROVIDED TO THE ARCHITECT AND <br />ENGINEER AT THE COMPLETION OF THE PROJECT. AIRSIDE BALANCE AND <br />CAPACITY CHECKS SHALL BE RUN ON ALL SYSTEMS. THE WRITTEN REPORT <br />SHALL BE ON FORMS RECOMMENDED BY AABC. <br />6. COPIES OF THE MECHANICAL SUBCONTRACTOR'S FIRST YEAR GUARANTEE FOR <br />THE INSTALLATION SHALL BE PROVIDED TO THE OWNER. NOTATION SHALL BE <br />INCLUDED TO SHOW THE EXPIRATION OF THE FIRST YEAR PARTS AND LABOR <br />GUARANTEE AND OF THE EXTENDED FOUR (4) YEAR COMPRESSOR WARRANTY. <br />7. DEVIATION FROM MATERIALS, METHODS OR PROCEDURES SET FORTH <br />HEREIN MUST BE APPROVED BY THE ENGINEER, IN WRITING, PRIOR TO BID <br />OR COMMENCEMENT OF WORK. <br />8. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ALL COST <br />INCURRED BY ANY TRADE DUE TO THE SUBSTITUTION OF MECHANICAL <br />EQUIPMENT. ANY CHANGES SHALL BE COORDINATED WITH THE TRADES <br />INVOLVED. <br />MECHANICAL EQUIPMENT <br />1. AIR CONDITIONING EQUIPMENT SHALL BE FACTORY PACKAGED <br />STRAIGHT COOL WITH ELECTRIC HEAT. <br />2. ALL AIR CONDITIONING UNITS SHALL INCLUDE A ONE (1) YEAR <br />WARRANTY AND AN EXTENDED FOUR (4) YEAR COMPRESSOR WARRANTY. <br />3. FILTERS SHALL BE PROVIDED IN THE UNITS. THE FACTORY FILTER <br />SHALL BE USED DURING CONSTRUCTION AND A NEW SET OF REPLACEABLE <br />MEDIA, IN METAL FILTER FRAMES, SHALL BE PROVIDED JUST PRIOR TO <br />TEST AND BALANCE. <br />4. ALL UNITS SHALL BE PROVIDED WITH A FACTORY CURB. CURBS SHALL <br />BE SET LEVEL ON TOP, WITH LEVEL STRUCTURAL STEEL SUPPORT <br />FRAMES PROVIDE BY THE STRUCTURAL STEEL SUBCONTRACTOR. <br />5. ELECTRICAL POWER AND CONTROL CONDUITS SHALL RISE UP, INSIDE <br />THE CURB OF THE ROOF TOP UNIT. <br />6. ROUTE CONDENSATE PIPING AS SHOWN ON PLANS. <br />CONDENSATE PIPING <br />1. EXTERIOR CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC WITH UV <br />INHIBITOR RATED FOR EXTERIOR USE. <br />lows i�Li iI:0 <br />1. SUPPLY AND RETURN DUCTWORK SHALL BE TYPE 800 FIBERGLASS EQUAL TO <br />JOHNS-MANVILLE "MICRO-AIRE". DUCT SHALL BE 1-1/2" THICK WITH AN <br />INSULATION VALUE EQUAL TO R-6. SEAL ALL JOINTS WITH MASTIC. <br />2. EXHAUST AIR DUCTWORK SHALL BE GALVANIZED SHEET STEEL WITH ALL JOINTS <br />SEALED WITH MASTIC. ROUND EXHAUST AIR DUCTWORK SHALL BE ALUMINUM <br />"THERMOFIN" OR SINGLE WALL ROUND SHEET METAL. EXHAUST AIR DUCTS DO <br />NOT NEED TO BE INSULATED UNLESS REQUIRED BY LOCAL ORDINANCE. <br />3. ALL DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA <br />REQUIREMENTS. <br />4. ALL DUCTS SHOWN ARE INSIDE CLEAR DIMENSIONS. <br />5. SIZING OF DUCT SHALL BE BASED ON 0.10"/100 FT. EQUAL <br />FRICTION FOR SUPPLY DUCTWORK AND A MAXIMUM 800 FPM VELOCITY FOR <br />THE RETURN DUCTWORK. <br />6. FLEXIBLE DUCT SHALL NOT BE ALLOWED EXCEPT FOR FINAL DIFFUSER <br />RUNOUTS. <br />7. HOLD THE BOTTOM OF THE SUPPLY AIR DUCT AT A MAXIMUM OF 24" <br />ABOVE HUNG CEILING FOR ACCESSIBILITY PURPOSES. <br />8. PROVIDE FLEXIBLE CONNECTION FROM EACH DUCTWORK CONNECTION TO <br />AIR HANDLERS AND FANS. <br />9. PROVIDE ACCESS PANELS IN DUCTS FOR ACCESS TO VOLUME DAMPERS, AND <br />WHERE REQUIRED FOR MAINTENANCE OF ALL FANS AND MECHANICAL <br />EQUIPMENT, PANELS SHALL HAVE A FIRE RATING EQUAL TO THE <br />PENETRATED ASSEMBLY (MINIMUM ONE (1) HOUR). <br />10. ALL FLEXIBLE BRANCH CONNECTIONS SHALL HAVE A MANUAL VOLUME <br />DAMPER INSTALLED AT MAIN TRUNK FOR BALANCING PURPOSES. <br />CONTROLS <br />1. THERMOSTATS SHALL BE BY UNIT MANUFACTURER. ALL THERMOSTATS <br />SHALL HAVE STAGES OF COOLING AND HEATING TO MATCH SPECIFIED UNIT AND <br />SHALL BE 7-DAY PROGRAMMABLE. <br />2. LOCATE ALL THERMOSTATS 5'-0" A.F.F. UNLESS OTHERWISE NOTED. <br />EXACT LOCATION OF ALL THERMOSTATS SHALL BE APPROVED BY THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />3. EXHAUST FANS SHALL BE CONTROLLED AS NOTED ON THE EXHAUST FAN <br />SCHEDULE. <br />4. 24 VOLT DUCT SMOKE DETECTORS SHALL BE FURNISHED AND INSTALLED <br />BY THE MECHANICAL CONTRACTOR IN THE SUPPLY AIR DUCT OF ALL <br />UNITS WITH A DESIGN CAPACITY GREATER THAN 2000 CFM. MECHANICAL <br />CONTRACTOR SHALL POWER SMOKE DETECTOR VIA LOW VOLTAGE CONTROL <br />TRANSFORMER IN UNIT. ALL SHUT DOWN CONTROL WIRING SHALL BE BY <br />THE MECHANICAL CONTRACTOR. <br />5. PER NFPA 90A 6-4.4,3, WHERE THE SMOKE DETECTORS ARE INSTALLED IN A <br />BUILDING NOT EQUIPPED WITH A FIRE ALARM SYSTEM, EACH DETECTOR SHALL <br />HAVE A REMOTE TEST STATION WITH A VISUAL AND AUDIBLE SIGNAL LOCATED <br />ADJACENT TO THE ROOM THERMOSTATS FOR EACH AIR HANDLING UNIT WITH A <br />SMOKE DETECTOR, <br />AI <br />Job Number: 6517 <br />'Colwill Engineering <br />Consulting Engineers, Inc. <br />Engineering Business No. 9021 <br />4750 East Adamo Drive Tampa, Florida 33606 <br />Tel: 813-241-2525 Fax: 813-241-2424 <br />\\� © 2013 ALL RIGHTS RESERVED <br />Y <br />le TeC- <br />I ao n awl <br />Associates, Inc. AA26001933 <br />Architecture • Planning • Interior Design <br />14125 N.W. 80th Ave. Suite 303 <br />Miami Lakes, FI. 33016 <br />T. 786-235-9097 <br />F. 305-362-4420 <br />dtiinfo@dtiarchitect.com <br />www.dtiarchitect.com <br />��t�rrrrrri <br />N 8186 <br />T TE OF ' <br />4.0 <br />S, 'O N A; ' <br />Joseph R. Stolz, <br />P.E. No.58186 <br />Revisions: <br />Date Description <br />10-21-13 OWNER CHANGES <br />Ix <br />C7 <br />Zj <br />NO M <br />M <br />O <br />Ho <br />w <br />WW <br />U <br />�+ <br />� <br />W <br />� <br />W <br />W <br />� <br />Q <br />Z <br />Job Number: <br />12049.01 <br />File name: <br />Issued Date: <br />07.17.13 <br />Drawn by: <br />CR <br />Checked by: <br />JS <br />I I SHEET NAME I I <br />MECHANICAL <br />PLAN <br />SHEET NUMBER <br />M-1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.