Florida Building and Residential Codes , <br />6t-'� Edition (2017) <br />Code for Design Loads <br />BOTTOM CHORD LIVE LOAD <br />ATTICS WITH LIMITED STORAGE. .............. <br />20 PSF (PER FRC) <br />BASIC WIND SPEED <br />SPECIAL FLOOR (GAME ROOM) LOADING .... C, = 1,00 <br />DEFLECTION CRITERIA <br />LL1240 <br />TL MAX 1" UP TO 40'SPAN <br />NOTES: <br />1� PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL <br />ABOVE SHALL NOT EXCEED %''DEFLECTION <br />WINDOWS AND DOORS <br />EFFECTIVE <br />WIND A EA <br />RE <br />ZONE DESIGNATION <br />IZ - interior Zone (ps� <br />EZ - End Zone (ps� <br />VINYL SOFFIT MAX PRESSURE (psf) <br />+28.6 <br />-38.3 <br />GARAGE DOOR PRESSURE <br />+21.7 <br />-24,6 <br />END ZONE KEY MAP. <br />EN[ZONE: END ZONES SHALL BETAKEN <br />AGTHE 1ST4_O'PERFIGURE R3O1.3(7) <br />END ZONE <br />| DESIGNATION <br />ly <br />WHO** 712FIA, <br />�4 0 <br />TILE ROOF <br />MIN'V32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION <br />0 z <br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS: 4" O.C. AT PANEL EDGES AND <br />LL < (:) <br />0 LU Z <br />SHINGLE AND METAL ROOF <br />MIN �46" 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION <br />0 <br />PERPENDICULAR TO SUPPORTS W/ 8d RING SHANK NAILS: 6" O_C_ AT PANEL EDGES, 12" <br />FLOOR DECK SHEATHING: <br />"/32" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE <br />(NOTE 5) <br />FIELD. <br />MIN %" OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d <br />PORCH CEILING BOARD SHEATHING: <br />COMMON: 3" O.C. AT PANEL EDGES, 12" O.C. IN THE FIELD OR MIN Y2" EXTERIOR GYPSUM <br />CEILING BOARD, FASTEN w/ 5d x 1 %" COOLER NAIL OR NO.6 x 1114" LONG SCREWS @ <br />NOTES: <br />1 FOR SHEATHING THICKNESS GREATER THAN '%2'CATEGORY (32/16 SPAN RATNG).USE 1OdRING SHANK NAILS |NLIEU OF8dRING <br />SHANK NAILS. (O14O''x3''LONG). <br />z- ZIP SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. <br />3. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF <br />CURRENT APPROVED APA.MANF.SPECIFICATIONS. <br />4. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TOHELP <br />REDUCE SQUEAKING, 0dRING SHANK NAILS OROdSCREW NAILS ARE RECOMMENDED. <br />5.`.'/32''PLYWOOD !G&WARRANTY LIMITATION COMMON TDTILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY <br />AND INSTALLATION REQUIREMENTS ALLOW, '%2" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. <br />O. MINIMUM STRUCTURAL ROOF SHEATHING REQUIREMENTS FOR METAL ROOF CLADDING IS SAME AS SHINGLE ROOF. SHOULD ROOF <br />MANUFACTURER'S INSTALLATION DRAWINGS REQUIRE SPECIFIC ROOF SHEATHING EXCEEDING THE STRUCTURAL MINIMUM, <br />CONTRACTOR SHALL PROVIDE ROOF SHEATHING IN ACCORDANCE WITH ROOFING SPECIFICATIONS. <br />TABLE SIZE LEGENDTAFASTENERS <br />NOTES 1, 2 3 4 PRESSURE TREATED LUMBER <br />NOTES: <br />1 INSTALL 1OdNAILS UNLESS OTHERWISE SPECIFIED. <br />2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS <br />SHALL CONFORM T0THE NOMINAL SIZES SPECIFIED !NA8TN <br />F1007. NOMINAL DIAMETER SIZES APPLY TOFASTENERS <br />BEFORE APPLICATION OFPROTECTIVE COATING. <br />3. WHEN ABORED HOLE |8REQUIRED TOPREVENT SPLITTING OF <br />AWOOD DUE TOFASTENER PENETRATION, THE BORED HOLE <br />SHALL NOT EXCEED 75%OFTHE NAIL ORSPIKE DIAMETER. <br />4. THE NOMINAL DIAMETER AND LENGTH OFTYPICAL FASTENERS <br />SPECIFIED FOR THIS PROJECT ARE AGLISTED |NTABLE 4. <br />PRESERVATIVE <br />FASTENER TYPE <br />ACZA <br />STANDARD CARBON STEEL <br />SODIUM BORATE (NOTE 1) <br />STAINLESS CONNECTORS AND <br />FASTENERS REQUIRED. <br />CONNECTORS MUST HAVE <br />ALL OTHER PT <br />Z-MAX, G120 OR TRIPLE ZINC <br />(INCLUDING ACQ & MCQ) <br />COATED FINISH. <br />ALL FASTENERS MUST BE HOT <br />DIPPED GALVANIZED. <br />NOTES: <br />1 SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON <br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY <br />EXPOSED TOEARTH DRWEATHER AND HAVE BEEN PROVEN <br />TOBENON-CORROSIVE T0CARBON STEEL FASTENERS. <br />CONCRETE AND FOUNDATION NOTES <br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTmGS~2.5OOPSI AT28DAYS (UN{). <br />2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB =2.580PSI AT20DAYS (UN[). <br />3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). <br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE <br />INSTALLED ATALL REENTRANT CORNERS. <br />5. F|8ERMESH}OANACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE VVYVF. FIBER LENGTHS SHALL 8E%^TO2^|NLENGTH. <br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH A8TMC1110. THE MANUFACTURER ORSUPPLIER SHALL PROVIDE <br />CERTIFICATION OFCOMPLIANCE WHEN REQUESTED BYTHE BUILDING OFFICIAL. <br />0. MASONRY 8TEMVVALLAND MONOLITHIC FOOTING ARE INTERCHANGEABLE. <br />7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 psf IN <br />ACCORDANCE WITH TABLE R401,4.1. AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. |T|STHE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TDCONFIRM THESE ASSUMPTIONS. <br />8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH <br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL. WITH APPROVED CHEMICAL SOIL TREATMENT FOR <br />PREVENTION OFSUBTERRANEAN TERMITES. <br />8. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER <br />OF RECORD |FTHIS CONDITION EXISTS, <br />10. TO CONTROL CRACKING, CUT 1" SAWCUTS IN THE SLAB IN A 15'x15'GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />CONTACT EOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN VAIVF OR FIBERMESH ARE INCLUDED <br />WITH CONCRETE WORK. <br />11 DONOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DONOT DETERMINE FOOTING LOCATION <br />FROM ARCHITECTURAL PLANS 0RFRAMING PLAN. |FFOOTING SIZE ORLOCATION |8NOT DETERMINATE FROM USE DF <br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OFRECORD. <br />PRE-ENGINEERED TRUSSES & I -JOISTS <br />1 ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE <br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED FLORIDA PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS <br />SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TP1 AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO <br />FABRICATION. DESIGN CRITERIA |GLOCATED ONSHEET 8T-1OFTHE PLAN SET. TEMPORARY BRACING SHALL BETHE <br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. <br />2. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND <br />NAMING CONVENTION OFTHE LAYOUT SHOWN HERE. <br />3. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM <br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. <br />4 TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN <br />OFTHE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. A8SUCH, THE REPORTED UPLIFTS ONTHE TRUSS SHOP DRAWINGS <br />MAY 8EDISREGARDED. <br />5 I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND <br />SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION.SEE DESIGN CRITERIA, <br />THIS SHEET, <br />CONNECTORTABLE 7: METAL <br />NOTEG2. 14 <br />USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOWARE EQUAL <br />ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE <br />SIMPSON <br />SIMPSON FASTENERS <br />LISP <br />LISP FASTENERS <br />SIMPSON <br />SIMPSON <br />FASTENERS <br />USP <br />USP FASTENERS <br />DTT2Z <br />IN STUD Y2" 0 X 4 Y2" <br />WOOD SCREWS IN STUD <br />(9) 10d COMMON <br />(9) 1 Od <br />(NOTE 2) <br />EMBED EPDXY OR <br />DTB-TZ <br />% 0 x 4%." EMBED EPDXY <br />CS18 <br />EACH END <br />CS20 <br />COMMON <br />SCREW ANCHOR <br />OR SCREWANCHOR <br />EACH END <br />(NOTE2) <br />§8" 0 x6" EMBED ANCHOR <br />0 x 6" EMBED ANCHOR <br />EACH END <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />HTT5 <br />STUD/BEAM/TRUSS <br />HTT45 <br />STUD/BEAM/TRUSS <br />MSTA24 <br />(9) 10d COMMON <br />MSTA24 <br />(9) 10d COMMON <br />(NOTE 2) <br />�8" 0 x 6" EMBED ANCHOR <br />0 x 6" EMBED ANCHOR <br />EACH END <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />HDQ8-SDS3 <br />IN STUD GROUP <br />PHD8 <br />GROUP-1/8" 0 x 12" EMBED <br />MSTA36 <br />(13) 1 Od COMMON <br />MSTA36 <br />(13) 1 Od COMMON <br />0 x 12" EMBED <br />ANCHOR IN CONCRETE <br />EACH END <br />EACH END <br />ANCHOR IN CONCRETE <br />META12 <br />4" WET EMBED IN <br />HTA16-18 <br />4" WET EMBED IN <br />MSTAM36 <br />WOOD FRAMING <br />MSTAM36 <br />WOOD FRAMING <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(4) W' x 2 %" TITEN <br />(5) Y4" x 2 %" TAPCON IN <br />SCREWS IN MASONRY <br />MASONRY <br />META20 <br />4" WET EMBED IN <br />HTA20-18 <br />4" WET EMBED IN <br />HTS20 <br />TRUSS/RAFTER <br />HTW20 <br />TRUSS/RAFTER <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(11) 10d x I Y2" IN <br />(11) 1 Od x I %" IN <br />STUD <br />STUD <br />ABU44 <br />(12) 16d COMMON NAILS <br />PAU44 <br />(12) 16d COMMON NAILS <br />HTSM20 <br />TRUSSIRAFTER <br />HTWM20 <br />TRUSS/RAFTER <br />STUD <br />OR EQUIVALENT IN STUD <br />ABU66 <br />%" 0 x 7" EMBED EPDXY <br />PAU66 <br />§8" 0 x 7" EMBED EPDXY <br />H2.5T/ <br />TRUSS <br />RT71 <br />TRUSS <br />DOOR RETURNS) <br />DOOR RETURNS) <br />TOP PLATE <br />TOP PLATE <br />HUC48, <br />HEADER <br />HD481F, <br />HEADER <br />HS <br />TRUSS <br />RT8A <br />TRUSS <br />HUC28-2 <br />HD28-21� <br />TOP PLATE <br />TOP PLATE <br />H UC41 0, <br />HEADER <br />HD4101F, <br />HEADER <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />LGT2 <br />LUGT2 <br />HUC210-2 <br />BEAM <br />HD210-21F <br />BEAM <br />SCREWS IN MASONRY <br />OR EQUIVALENT <br />HEADER <br />HD212-21F <br />HEADER <br />(10) 10d COMMON IN BEAM <br />(10) 10d COMMON IN BEAM <br />LGT 3 <br />IN WALL F RAMING <br />LUGT3 <br />FRAMING <br />(4)%" x 1 W SDS SCREW <br />(4) Y4"x1Y2" WS 15 SCREWS <br />IN TRUSS <br />IN TRUSS <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />IN TOP PLATE <br />IN TOP PLATE <br />SDWC14500, SDWC15600 <br />NO USP EQUIVALENT <br />HGAM10KTA <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />L_ <br />IN MASONRY <br />OR EQUIVALENT IN <br />MASONRY <br />NOTES: <br />1 REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. <br />2. PRODUCTS SELECTED USING G|MPGON2O17-2O18CATALOG. PRODUCTS MAY BESUBSTITUTED WITH EQUAL 0RBETTER APPROVED ALTERNATES, <br />3. REFER TOG|MPGONCATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. <br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT EOR FOR SPECIFIC FASTENING REQUIREMENTS. <br />5. POSITIVE PLACEMENT GUN NAILS, 21/2'LONG, WITH EQUIVALENT DIAMETER TOCOMMON NAILS SPECIFIED ABOVE MAY BEUSED FOR <br />ABUPOST BASE ANCHORS. C81O.AND MGTAFLAT STRAPS. <br />8. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES <br />Y4'0x2�/�^TITEN8ILO 10d.CONCRETE REQUIRES EQUIVALENT NUMBER OFX;'0x1'/4'T|TENSILO 1Od. <br />1 ALL MASONRY UNITS SHALL HAVE f m = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL <br />BED. <br />2. ENGINEER OF RECORD RECOMMENDS, BUT DOES NOT REQUIRE, ALL RUNNING BOND MASONRY WALLS TO BE EQUIPPED w/ 9 <br />GAUGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT ATEVERY OTHER COURSE, <br />3 SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER <br />TYPE HORIZONTAL JOINT REINFORCEMENT <br />4 ALL GROUT TOMIXED PER ASTMC4T0STANDARDS. fo=250OPG| <br />5. VERTICAL WALL REINFORCING TO8EA8TMAO15GRADE OOREBAR <br />0. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO8E25" <br />7 VERTICAL REINFORCING T0HAVE 1O^STANDARD HOOK INTO BOND BEAM. DOWEL TOHAVE 1O''STANDARD HOOK INTO FOOTING. <br />8 PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. <br />9 PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. <br />_ <br />Z� <br />m <br />��_��c_"n� <br />LEGEND <br />� <br />� <br />OR <br />',]R.SHALL MEAN THAT EITHER OPTION PROVIDED |GANEQUAL <br />ALTERNATIVE FOR THE APPLICATION SHOWN <br />UNO <br />UNLESS NOTED OTHERWISE DNPLAN ORDETAIL <br />EOR <br />ENGINEER 0FRECORD <br />EYV <br />EACH WAY <br />O88 <br />ORIENTED STRAND BOARD <br />VV8P <br />WOOD STRUCTURAL PANEL <br />'« <br />8YP <br />SOUTHERN YELLOW PINE <br />w� <br />8PF <br />' - <br />SPRUCE -PINE -FUR <br />r- <br />ry <br />CUNT <br />CONTINUOUS <br />00 <br />D.C. <br />ON CENTER <br />L8L <br />1.55ETiMBERGTRANDLGLENGINEERED LUMBER, 13/4^WIDE, UNO. <br />m <br />(3yS'VNDELGLBEAMS ARE EQUIVALENT TD2-PLY1Y{''BEAM) <br />' <br />LVL <br />2OEM|CROLLAMLVLENGINEERED LUMBER, 1|{''WIDE <br />r- <br />PSL <br />28EPARRALLAMP8LENGINEERED LUMBER, 8%^WIDE, UND, <br />�- <br />GYG42 <br />PROPERLY RATED OPEN WEB HEADER <br />N <br />rn <br />_j <br />INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS <br />LL <br />OUTLINED DmTYPICAL WALL SECTIONS, DETAIL SHEETSILLI <br />- <br />INTERIOR BEARING WALL WITH N0UPLIFT. NVUPLIFT ANCHORS REQUIRED. MINIMUM <br />_� <br />BOTTOM PLATE ANCHORAGE |Si{''ANCHOR @8''O''0.0 (UNOONFRAMING PLAN DR <br />GVVSPECIFICATIONS) <br />z <br />STRUCTURAL WOOD BEAM <br />STUD COLUMN KEYNOTE <br />NUMBER OFSDVVC15OOOCONNECTING TOP PLATE TDSTUDS, <br />-� <br />- <br />o <br />NUMBER DFSTUDS BELOW BEAM/GIRDER TRUSS. STUDS <br />c:) <br />TOMATCH WALL FRAMING SIZE AND GRADE, VNO. <br />r- <br />0 <br />- <br />ADD|T0NALCLARITY FOR THE LOCATION OFTHE STUD COLUMN <br />F__ <br />] <br />2 ANCHOR <br />UD <br />BOTTOM OFSTUD COLUMN CONNECTION <br />1ST LEVEL STUD COLUMN: HOLDDOVVNREQUIRED KTBASE OFCOLUMN <br />0 <br />>_j <br />ZNDLEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2NDLEVEL <br />COLUMN TO1STLEVEL 8TUD8/HEADER/BEAM <br />co <br />'y\NCH0R''REQUIRES BOTTOM PLATE ANCHOR WITHIN J^OFSTUD COLUMN <br />LLI <br />NUMBER OFSDVVC15450CONNECTING STUDS TOBOTTOM PLATE <br />CK <br />HEADER STRAPPING KEYNOTE <br />0 <br />NUMBER OFSTRAPS CONNECTING HEADER TDJACK STUD <br />U) <br />TYPE 0FSTRAP CONNECTING HEADER TDJACK STUD <br />0 <br />KING/JACK GROUP BOTTOM CONNECTION <br />0 <br />1ST LEVEL STUD GROUP: HOLQDOVVNREQUIRED ATBASE 0FSTUD GROUP <br />T7_ <br />2NDLEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2NDLEVEL STUD <br />UJ <br />GROUP T01OTLEVEL GTUDG/HEADER/8EAM. <br />O� <br />NUMBER OFHOLQB0VVNS/STRAPSATBASE OFKING/JACK GROUP <br />NON -BEARING HEADER FRAMING KEYNOTE <br />NUMBER OFKING STUDS EACH SIDE OFOPENING <br />'- <br />LO <br />HEADER MAY 8EFRAMED AGNON BEARING HEADER DUE T0LIGHTLY <br />/~ <br />^"""="^u"=.,u..on"v.c 0 <br />NUMBER OFKING STUDS EACH SIDE 0FOPENING <br />LIJ <br />NUMBER OFJACK STUDS EACH SIDE 0FOPENING <br />z <br />DEPTH VFLOAD-BEARING #2SYPHEADER <br />ZJ <br />NUMBER OFPLIES |NHEADER <br />co <br />ci� <br />ENGINEERED LUMBER HEADER FRAMING KEYNOTE <br />UU <br />NUMBER OFKING STUDS EACH SIDE 0FOPENING <br />z <br />[-HEADER <br />NUMBER OFJACK STUDS EACH SIDE 0FOPENING <br />_ <br />z <br />MATERIAL (LSL, LVL, PSL. OROYG42) <br />UJ <br />DEPTH OFLOAD-BEARING EVVPHEADER <br />[] <br />NUMBER OFPLIES |NHEADER (1-/4''VNDEUNO)HEADER <br />-- <br />O� <br />FRAMING <br />i <br />LL <br />1 ALL HEADER JACK AND KING GTUIDS SHALL BEFASTENED TOEACH OTHER WITH (2)ROWS 1Od@O''0C <br />z <br />STAGGERED. <br />0 <br />2. DUE TDLIGHTLY LOADED CONDITIONS, 48''ORLESS CLEAR -OPENINGS |NAN <br />EXTERIOR VVALLDONOT REQUIRE LOAD BEARING HEADER, SEE PLAN <br />' <br />3. FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROWS 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. <br />Of <br />4. FASTEN ALL HEADERS TDKING STUDS WITH (3)8dTOE NAILS <br />5, IFHEADERNOT SPECIFIED, CONTACT ENGINEER DFRECORD. <br />0 UNODNPLAN, MIN (1)SDVVC156O0TOP PLTTOKING STUD AND (1)GDVVC15450KING STUD T0BOTTOM PLATE <br />CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST <br />0 <br />C) <br />FLOOR HEADER WHEN A2ND LEVEL FLOOR SYSTEM !S ABOVE, <br />7 TOP PLATE TO HEADER CONNECTION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR <br />< <br />OPENINGS 39" OR LESS, OR AT FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: <br />[] <br />°ODVVC15OOV0yMAX 32^OCA8SHOWN, "ALTERNATE SECTION (HEADER8).ST'5 <br />°SPHw/(12)18dx11}8''8g16^O.C.DR <br />0 <br />~D8P*y(14)1Udxl'yi''@16"O.C.IUR <br />U_ <br />= FASTEN TRUSS DIRECTLY TOHEADER w/MT8ORHTGwY(14)1Odx1�2"(OR EQUAL APPROVED 8YEOR). <br />< <br />8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MAY BEFRAMED AT24'O.C. <br />- <br />CJ <br />z <br />FRAMING NOTES <br />1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS . <br />ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN 0 <br />AHOLE A@SPECIFIED BYMANF(TYPICALLY 1/10''T31/G^GREATER THAN SPECIFIED ANCHOR D|AMETER). <br />z <br />ADHESIVE/EPDXY MUST FILL THE HOLE /NTHE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S <br />][ <br />SPECIFICATIONS MUST 8EFOLLOWED FOR PROPER INSTALLATION. <br />2 ALL LUMBER SPECIFIED ONDRAVVNg8|�|NTENDEDFVRDRYU8E0NLYUN0ALLVVATERPROOF|N8ANDF|RE8AFE7Lu <br />� <br />. <br />SYSTEMS ARE THE RESPONSIBILITY DFTHE CONTRACTOR AND ARE TOBEDESIGNED AND DETAILED BYOTHER. <br />�- <br />3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN <br />x <br />TABLE 230491 <br />~~ <br />CL <br />4 BEAMS IDENTIFIED BYNUMBER ONPLAN ARE T08EPROVIDED BYTRUSS MANUFACTURER. <br />< <br />5, FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 1 Od @ 8" O.C.STAGGERED. <br />UPPER LEVEL MULTI -PLY STUD GROUPS BELOW ALL GIRDER LOCATIONS TO BE CONTINUOUS THROUGH FLOOR <br />< <br />SYSTEM TOFOUNDATION. (NOT REQUIRED BELOW HEADER JACK/K|NGSTUD GROUPS) <br />-� <br />5 FASTEN ALL STUDS TO BOTTOM AND TOP PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS. <br />7 FASTEN ALL TRUSSES AND RAFTERS TOTOP PLATES WITH (3)BdTOE NAILS. <br />c0 <br />0 ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM <br />[] <br />THICKNESS AND MATCHING WALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN, UNO.UU <br />8 EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATHED WITH DSBORPLYWOOD <br />z <br />true design studios <br />~ <br />3= <br />9000REGENCY SQUARE BLVD. (m <br />SUITE 1UO'JACN8OWV|LLE,FL��2�11 mn <br />� <br />� <br />04ft*H0ff0N <br />Al A <br />Uj <br />Abboft Park <br />LOT054-03-A [] <br />_ <br />PROJECT NO: LU <br />2019.007603 0 <br />UL <br />__--'_---------- _---- --------- -------------------------------- 0 <br />DRAWN: CRD <br />uxxo: -^ <br />EAF 0 <br />W <br />09 <br />' i5 <br />~~ �� . <br />z <br />09119/2019 ._ <br />REVISIONS: UU <br />No. Descriptionj Date <br />F- <br />0 <br />0 <br />