ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />R4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />---- <br />TRACK LIGHT <br />—� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />opli <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />r I I I HANSON <br />I I <br />BOX <br />I I <br />LA nu C <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />OPT. <br />LAV <br />LOAD CALCULATIONS <br />Unit -C- (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER A WATTS <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />P I . NEMA 1 <br />200 AMP <br />T-- ....1 <br />1 �0-200 All (P I I T /---Serial Cable <br />3R <br />Power Co. Feed —` 1] I_ #4 Solid COPPER Ground <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />DB&GFI TO <br />BE ALIGNED <br />VERTICALLY <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHTROUGH-IN <br />FOR OPT. <��FAN/LIGHi GFI <br />M�a 1:� <br />DININGKITCHENFI 'l_ GFISWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM</�>ROUGH-IN\ <br />FOROPT. <br />FAN/LIGHT <br />VTRY I, <br />GHT AS b <br />ER SPECS <br />1 <br />It <br />FI <br />L0 X <br />QO <br />O� L =J <br />0 Z) <br />I <br />I <br />I <br />I <br />I <br />I <br />rGF-L <br />C.M <br />1 UPSTAIRS � <br />F4"\\W.H. <br />.F. <br />0 <br />IGARAGE <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />r----------------- <br />Ip ZI0I,I>- <br />Iu-I� <br />JI> <br />LU <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL -UNIT-C 1624 <br />SCALE: Y4"=V-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL — UNIT—C 1624SCALE: Y"=V-0" <br />N <br />— <br />O <br />C1 <br />00 <br />�> _ C7 <br />°) <br />o <br />�d <br />Ljj <br />J <br />� <br />L <br />i1 <br />u, <br />L.) _.. <br />C' v <br />LU <br />CV <br />fV <br />0 <br />CV <br />ti <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code . <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal <br />W <br />E <br />o $ <br />0N <br />LQa <br />Y � <br />o <br />rn -�f <br />N <br />7' <br />C J <br />Z <br />% LL <br />LL <br />V <br />13,Q <br />J <br />w <br />a <br />ul <br />_ e <br />W <br />Cg <br />og <br />0 <br />W <br />Z <br />LL <br />rn °' <br />04 MZ <br />N <br />O U <br />U <br />W <br />0 rn <br />El <br />N f7 <br />o <br />� � <br />Q <br />E3 <br />U) <br />to <br />M <br />Z <br />U s <br />ty <br />a--+ <br />V � � <br />O <br />w s <br />U <br />W J <br />� E <br />g <br />t <br />09 -6 <br />S I� <br />o <br />w <br />Z <br />Cl) <br />LL_ <br />LQ <br />Z <br />EG� <br />vo <br />O � <br />O <br />oc <br />�z <br />�° <br />na <br />O <br />w� <br />N � <br />~ <br />Q? <br />an <br />a Y <br />m� <br />Z <br />VJ � <br />J <br />�x <br />c"i b <br />zz <br />? rWn <br />LLa <br />Z <br />W <br />o� <br />C <br />O <br />5 <br />o <br />V' <br />OZG <br />OU$ <br />.o r <br />ai <br />rn <br />C1.4 <br />C7 <br />CC> <br />T <br />T <br />E <br />O <br />Lid <br />v <br />NM�1 <br />A <br />'�O_ <br />0- m <br />60 <br />.-- <br />C r— <br />CN <br />L17 <br />~ <br />O <br />CD <br />c <br />C <br />N <br />d <br />Cfl <br />CD <br />Q 00 <br />� <br />In <br />OQ <br />f� <br />r <br />E <br />'E <br />o <br />Z <br />M <br />Z <br />:3N <br />E O <br />N <br />o <br />C <br />JOB <br />NO: 22-08433-08426 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />15 <br />