My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3187 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
3187 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:03:40 AM
Creation date
2/19/2025 2:20:51 PM
Metadata
Fields
Template:
Building Plans
Street #
3187
Location
Fallstone Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAxl-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />� r <br />r j <br />r <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />16GAx1-1/2" LONG (3/4"-1" 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />CROWN) STAPLES @ 6" OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6". <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) DOUBLE JOIST CONNECTION <br />N.T.S. <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF L J <br />HOME H C G <br />GARAGE SIDE 0 0 O <br />5'-0" a - <br />STUB -OUT FORLO <br />0 C)° <br />GAS METER <br />O <br />CV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1) SIMPSON HTS20 OR 3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3!4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.811.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking <br />BEARING Use 3" (10d) nails at 6" o.c. <br />Vertical load transfer =1900 plf max along load bearing wall. Load bearing walls <br />Load bearing wall must stack r <br />*Non -stacking walls over squash=20 blocks and y " <br />require additional wall or beam below.* <br />at bearing. ?1 - <br />Provide adequate bearing <br />for each lapped joist. <br />(quash block) 10dnails SECTION @ INT. BRG. WALL <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL—N STD, 900 HOOK <br />W <br />CONT. #5 HOOK <br />BAR <br />BOND BEAM <br />SIMPSON MGT <br />w/ (22)10d <br />NAILS TYP. GIRDER TRUSS <br />CONT. #5 <br />BAR 2X TOP PLATE <br />- - 5/81 <br />#5 CONT. THRU <br />J FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />_ 1 BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D-PLYWOOD <br />; <br />FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />,i r� <br />FOR BLOCKINGITJI <br />"—MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />above <br />to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. ) Small gap <br />2" min. <br />2" max. <br />4" max. _ Web Stiffener Fastener Schedule <br />Joist Bearing Location �I, <br />Series Depth_ End Intermediate <br />— 9-1/2, 2-8d 2-8d <br />BCI5000s® <br />11-7/8' 2-8d _ 3-8( <br />14 2-8d 5-8d <br />Clinch nails <br />r <br />9-1/2" 2-8d 2-8d <br />O <br />when ✓� <br />BCI 6000s" 11-7/8" 2-863-8d--- <br />possible <br />BCI 6500s®1 <br />2 $d 5-8d <br />- — <br />14" <br />6-8d <br />--� <br />- - <br />11-7/8" 2-8d 3-$d <br />BCI 60s®! 14" 2-8d 5-8d <br />Tight fit - �� <br />_ <br />��� 16" 2-8d 6-8d <br />_ <br />3 <br />114/8 3-16d -16d <br />2x4/Plywood/OSB web stiffener J <br />2" min. gC190s® <br />required when indicated or <br />4" max. 16" _L6-16� 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing <br />WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. <br />N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />1Y2' ROUND HOLE MAY -� A 6" 6" <br />A CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Y2' <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2' ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER, <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />- - 1/4"-2" gap L- � <br />f i <br />L <br />�Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1 /4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />-0.6 X Joist <br />✓ D /� , ' depth <br />n,4=_ <br />I —JOISTS BUCKETS <br />N.T.S. <br />LC <br />SIMPSC <br />w/ (22) <br />NAILS T <br />TYPICAL SIMPSON MGT TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM-� <br />SEE PLAN FOR •• a . • ; . <br />FOUNDATION INFO ' d' <br />STEM FOUNDATION <br />GRADE <br />° <br />i— REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12/METAI2TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />° <br />SECOND H10A <br />° ° °° <br />(WHEN <br />SIMPSON H10A ''�_-- <br />-=� <br />REQUIRED) <br />w/ (18)10d x 1 1/2" - <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />PLUMBING LINE <br />TOP (2) #5's x 4' 0" v <br />CENTERED @PIPE PVC OR SCH40 SLEEVE <br />PENETRATION <br />° G <br />a ° ° <br />, <br />a�I- <br />, <br />12" BELOW <br />GRADE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />° c d <br />c Z •° <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4' _0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 <br />-i 11—ll1= a ak4 <br />° r 11=11 I— <br />1 <br />SEE FND. PLN. <br />SIZE & REINF. <br />r 7 <br />r) <br />o <br />-t _ <br />[L, <br />W <br />U <br />_ <br />ti <br />LIJ <br />RID li" <br />J It <br />1 "" <br />C <br />IT <br />.' '' <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />4 <br />E <br />8 g8 <br />V (0 <br />tQ <br />Jn, <br />C14 C) <br />Q <br />aj M Q ss22LL <br />C J 5 �+ w <br />L, LL ii a <br />V' <br />Z <br />J uJ <br />—vim a <br />U� <br />W <br />0 <br />�MIrrn m <br />Z <br />0 <br />co Z d <br />ZN <br />OU U <br />W <br />❑ ❑ <br />c!) <br />to <br />n <br />/ <br />�-J <br />8 <br />1'` • <br />U <br />C <br />o � <br />Ln <br />c „ <br />w ro <br />v <br />< <br />O <br />� <br />w <br />z <br />U_ <br />m <br />pp <br />E <br />a'aR <br />z® <br />4 <br />O <br />H ry <br />5< <br />❑a <br />o E <br />N ra <br />i <br />f <br />a <br />EZ <br />w <br />d <br />a <br />a1 <br />m 7r <br />011 <br />z <br />Z <br />V <br />S <br />E <br />� <br />Nw <br />�, <br />lllllllllll� <br />o <br />CID <br />a <br />0 T <br />a) <br />> d' <br />ui <br />rn <br />N <br />cM <br />GO <br />T <br />~ <br />It1'7 <br />,-- <br />O <br />O <br />� <br />Co <br />ono <br />�- M <br />O <br />00 <br />r <br />C � <br />� <br />N <br />LO <br />F_ <br />:3 C) <br />N <br />M <br />C_ <br />+-a C)co <br />=3 ii <br />C�7 <br />00 <br />LO <br />00 <br />r <br />n <br />r <br />Z <br />Z <br />E O <br />In <br />lu <br />c <br />IL <br />y <br />Q <br />JOB <br />NO: 22-08433-08426 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.