My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3187 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
3187 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:03:40 AM
Creation date
2/19/2025 2:20:51 PM
Metadata
Fields
Template:
Building Plans
Street #
3187
Location
Fallstone Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I *DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />CONTINUOUS LATERAL <br />BRACING- NAIL OVER <br />X-BRACE AS SHOWN - <br />INSTALL BLKG. AT TRUSS <br />WEBS FOR NAILING <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />SEE ROOF <br />PLAN SHEATHING <br />_ - BLOCKIN <br />fi <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />X-BRACING - 2x4 SPF OR <br />SYP w/ 2-16d @ EACH TRUSS <br />WEB <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />SSES <br />(2) 12D NAILS <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />TRUSS NOTES. <br />TYP. HAND FRAMING ABOVE TRUSS <br />FRAMED RIDGE 2X4 STUDS & PLATES AT O.C. <br />CON1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />MAY B <br />MAY BE NAILED EACH DIRECTION TYP. U.N.O.N.O. <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER <br />w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS 2x8 BLKING. NAILED EACH <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />ILS WHN <br />SIDE w/ (3) 12d NAILS WHEN <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES &I <br />REQUIRED w/ (2) HTS20 <br />[ <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />W/ (14) - 10d X 1 1/2" EACH <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />'k k <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />Cg <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />DB <br />B <br />5. <br />PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX &EACH END ALTERNATE <br />DIRECTION TYP. -� <br />A <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />SCALE: 1 /2"=V-0" <br />HIP <br />G.T <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />DIAGONAL 2x8 #2 SPF RIDGE BEAM <br />AT 8'-0" WOOD <br />MAX TRUSS * * 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />J1F4 <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"0.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT-/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL aC� INTERIOR BEARING 3 <br />�LWOOD TRUSS -� SCALE: 1/2" = 1'-0" <br />-` <br />J A PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />TAIL STANDARD HEEL HEIGHT <br />TYP. WOOD TRUSS BLOCKING <br />DE <br />SCALE: 1 /2"= V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />PROVIDE 25" LAP <br />(2) SIMPSON SDWC15600 SCREWS @ <br />SPLICE @ F.C. REBAR <br />EACH TRUSS TO LEDGER <br />1/2" GYP. WB <br />OR 3/8" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />TOP -CHORD BEARING <br />COMMON @ 6" O/C TO ONE SIDE OF THE <br />FLOOR TRUSSES @ <br />FLOOR TRUSS FOR AN <br />24" O.C. <br />AREA 5 1000 SQ. FT. OF _ <br />FLOOR AREA & SEALED <br />2) 2x8 SYP #2 P.T. <br />PENETRATION AREA W/ <br />LEDGER ATTACHED TO <br />FOAM. DRAFTSTOPPING <br />_ <br />MASONRY w/ (2) ROWS <br />SHALL DIVIDE THE <br />1/2" SIMPSON TITEN HD, <br />CONCEALED SPACE INTO - <br />MIN. 5" EMBEDMENT PER <br />APPROX. EQUAL AREAS. <br />A <br />54/D1 SPACING. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />FLOOR CONNECTION @EXTERIOR WALL <br />SCALE: 3/4" =1'-1 <br />2'-0" MIN. <br />LAP SPLICE <br />1'-0" 6" 6" 1'-0" 6" 6" <br />TYP. <br />O O I O O <br />I SPLICE <br />O I O O <br />2.0 SPLICE BEYOND <br />PART. ELEV. VIEW <br />V-0" <br />TYP. <br />O 0- <br />0 <br />2'-0" <br />II: • : • <br />.0-7 <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 1/2" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />EDGER <br />OGETHER w/ <br />LAP b'PLIUL <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />- PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />(2) ROWS OF 10d NAILS @ 4" O.C. <br />FLOOR TRUSSES <br />—@ 24" O.C. <br />1.2sj <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 - ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0" O.C. T & B <br />FLOOR ATTACHMENT r5_d� <br />SCALE: 3/4" = V-0" <br />WOOD TRUSS <br />DETAIL - ADJACENT TO TRUSSES <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION.—, <br />PRE-ENGINEERED ROOF <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"x24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS, PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />1']ATTCAI CTf]flC• <br />MASONRY <br />SEE PLAN <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />10\_10A Tl11117AIAILS <br />2X6 P.T. CONT. <br />LEDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />O.C. T&B <br />(6)•.162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />w/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />MASONRY WALL--,= . <br />SEE FLOOR <br />PLAN FOR MORE <br />INFO. <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />MIN. 2x4 #2 SPF P.T. <br />CONT. W/ (2) "' W <br />TITEN2 SCREWS @ <br />16" O.C. <br />TRUSS OR <br />/ ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r52 <br />SCALE: 3/4' = 1'-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING.—� <br />2x4 BLOCKING @ 48" O.C. MAX. W/ 0 LB FELT (SHINGLES) <br />(2) 16d TOE NAILS @ EACH END FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK SHEATHING 4' ON EA. SIDE <br />RUNNER TO SHEATHING OF WALL NOT STAGGERED CEILING BOARD <br />ABOVE AT EACH SIDE OVER PARTY WALL <br />2x4 LEDGER @ 48" O.C. SEE ROOF PLAN <br />... _. -- - - <br />MAX VERTICALLY NAILED FOR STRAP INFO. <br />O 8d TO TRUSS WEBS W/ 2 BASE BOARD PER SPECS <br />STD 90° HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL <br />CELL PLAN FOR <br />UL-U905 (see sht 9) <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"0" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />SEE 53/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD — <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ 1' <br />8d COMMON AT 6" O.C. TO ONE SIDE OF , TOP CHOAp-B/RG. <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. FLOOR"SYSTEM <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP. <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN FOR LOCATIONS) <br />8" CONC. BLOCK (TYP.) PER UL905 - <br />1x P.T. BASE NAILER <br />6x6 W1.4xW1.4 WWF. ---r <br />w <br />U <br />J <br />a <br />. <br />a o I EXTEND BURN CLIPS AS PER 2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. FOR PLYWOOD EDGE NAILING <br />• R30 INSUL. MIN. SPECIFICATIONS NAILED INTO W/ (2) 1/4"x3"TITEN2 <br />o e I 2x4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />-- -- (2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH SCREWS @ EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" LEDGER <br />DRYWALL NAILS OR DRYWALL <br />SCREWS 7" O.C. EDGES. <br />SIMPSON RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS 3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />.0-7 <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 1/2" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />EDGER <br />OGETHER w/ <br />LAP b'PLIUL <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />- PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />(2) ROWS OF 10d NAILS @ 4" O.C. <br />FLOOR TRUSSES <br />—@ 24" O.C. <br />1.2sj <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 - ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0" O.C. T & B <br />FLOOR ATTACHMENT r5_d� <br />SCALE: 3/4" = V-0" <br />WOOD TRUSS <br />DETAIL - ADJACENT TO TRUSSES <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION.—, <br />PRE-ENGINEERED ROOF <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"x24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS, PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />1']ATTCAI CTf]flC• <br />MASONRY <br />SEE PLAN <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />10\_10A Tl11117AIAILS <br />2X6 P.T. CONT. <br />LEDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />O.C. T&B <br />(6)•.162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />w/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />MASONRY WALL--,= . <br />SEE FLOOR <br />PLAN FOR MORE <br />INFO. <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />MIN. 2x4 #2 SPF P.T. <br />CONT. W/ (2) "' W <br />TITEN2 SCREWS @ <br />16" O.C. <br />TRUSS OR <br />/ ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r52 <br />SCALE: 3/4' = 1'-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING.—� <br />2x4 BLOCKING @ 48" O.C. MAX. W/ 0 LB FELT (SHINGLES) <br />(2) 16d TOE NAILS @ EACH END FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK SHEATHING 4' ON EA. SIDE <br />RUNNER TO SHEATHING OF WALL NOT STAGGERED CEILING BOARD <br />ABOVE AT EACH SIDE OVER PARTY WALL <br />2x4 LEDGER @ 48" O.C. SEE ROOF PLAN <br />... _. -- - - <br />MAX VERTICALLY NAILED FOR STRAP INFO. <br />O 8d TO TRUSS WEBS W/ 2 BASE BOARD PER SPECS <br />STD 90° HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL <br />CELL PLAN FOR <br />UL-U905 (see sht 9) <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"0" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />SEE 53/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD — <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ 1' <br />8d COMMON AT 6" O.C. TO ONE SIDE OF , TOP CHOAp-B/RG. <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. FLOOR"SYSTEM <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP. <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN FOR LOCATIONS) <br />8" CONC. BLOCK (TYP.) PER UL905 - <br />1x P.T. BASE NAILER <br />6x6 W1.4xW1.4 WWF. ---r <br />w <br />U <br />J <br />a <br />. <br />a o I EXTEND BURN CLIPS AS PER 2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. FOR PLYWOOD EDGE NAILING <br />• R30 INSUL. MIN. SPECIFICATIONS NAILED INTO W/ (2) 1/4"x3"TITEN2 <br />o e I 2x4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />-- -- (2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH SCREWS @ EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" LEDGER <br />DRYWALL NAILS OR DRYWALL <br />SCREWS 7" O.C. EDGES. <br />SIMPSON RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS 3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />- <br />AFTER INSTALLING RBC'S <br />8"x8"x16" CONC. KNOCKOUT <br />BLK. W/ 1 #5 ROD CONT. <br />1/2" GYP. WB OR 3/8" <br />PLYWOOD/ <br />TYPE 2-M-W OSB <br />V . <br />FILLED W/ GROUT <br />(DRAFTSTOPPING) <br />" " <br />OBE NAILED W/8d <br />Y= <br />- <br />4 x4 INSPECTION PORT AT <br />- <br />EACH FILLED CELL (TYP.) <br />COMMON @ 6" O/C TO <br />1x P.T. BASE NAILER <br />ONE SIDE OF THE <br />STD. 90Q HOOK <br />FLOOR TRUSS FOR AN <br />(SEE DETAIL) <br />AREA <_ 1000 SQ. FT. OF <br />NAIL FLOOR TRUSS TO LEDGER W/ <br />FLOOR AREA &SEALED <br />4 10d TOENAILS (TYP.) EA. SIDE <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />SHALL DIVIDE THE <br />(2) SIMPSON SDWC15600 SCREWS @ <br />CONCEALED SPACE INTO <br />EACH TRUSS TO LEDGER <br />TOP CHORD BRG. <br />APPROX. EQUAL AREAS. <br />FLOC SYSTEM, <br />PRE-ENGINEERE <br />- <br />FLOOR TRUSS' AT <br />- - <br />24" O.C. <br />GYP. BOARD CLG. <br />- <br />DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA, COURSE FILLED W/ GROUT <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1" P.T. NAILER <br />R-3 MIN. INSUL. PER. FBC. <br />1/2" GYP. BD. <br />GYP. WB. <br />1 X 4 P.T. BASE <br />NAILER <br />�. <br />BASE BOARD <br />TYP. "S" MORTAR (TYP.) <br />PER SPECS. <br />U <br />CONC. SLAB <br />- <br />SEE FOUND. PLA <br />N <br />6 MIL VISQUEEN <br />4"x4" INSPECTION PORT. AT <br />EACH FILLED CELL (TYP.) <br />0 <br />fin•>��. T- <br />(4) #5 CONT. STD. 90Q HOOK <br />ON 3" CHAIR 8" 2'-0" 811 (SEE DETAIL) <br />2-STORY PARTY WALL SECTION PW01 <br />SCALE: 3/4"=V-0" <br />TREATED; <br />U <br />SEE PLAN <br />TOP OF PLATE <br />'--TOP COURSE W/ <br />�— LINTEL SEE <br />PLAN <br />SEE PLAN <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />1 U-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />`r F.F. <br />00 <br />VARIES WITH <br />b SITE GRADES <br />SEE PLAN <br />(V <br />T <br />3 #5 CONT. —� 20" <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />CV <br />N <br />( O <br />00 <br />� <br />W7 <br />Ge <br />LLI <br />rr\\\11 ti 111 I I I l lllrrr <br />Ire <br />�0 W N <br />• <br />J <br />FLU <br />A4'0F fSSO• <br />/rl;iii(IIt11 <br />To the best of the Engineers knowledge, infonnaflon and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />N <br />I- - g E <br />Q 8 <br />S <br />00 <br />IM 0 "o <br />iri in ti r� � J <br />M M c LL <br />N J <br />Q C LL <br />'--r W <br />0 �u.LL L a <br />2 <br />.� — l <br />L S0 <br />2 <br />o mnc° 0 <br />orn <br />W (D o, m <br />Z M Z a J <br />N <br />Z�' <br />OU < Q <br />W ❑ ❑ <br />z <br />L <br />Q <br />� <br />U <br />V) z <br />LL <br />Cn <br />� w <br />•0 <br />u <br />YZ <br />o <br />W <br />M <br />o <br />U_ <br />E <br />so <br />i� <br />E u <br />[O <br />� � <br />a <br />f o <br />R u <br />a <br />� O <br />� V <br />Z <br />o <br />N <br />a40 <br />¢o <br />a <br />L <br />¢ p <br />m i <br />Z <br />�r <br />in a; <br />o2 <br />z <br />,z <br />2z <br />17 <br />a s <br /><o <br />z <br />o <br />b= <br />216 <br />O 9 <br />T <br />o12 <br />> d' <br />an <br />rn <br />T <br />ca <br />� <br />cNfl <br />T <br />~ <br />O <br />n <br />•r <br />E <br />O <br />_ <br />CID 6 <br />OM <br />a. m <br />O <br />0o <br />T <br />C r <br />� N <br />L (-� <br />~ <br />O <br />c <br />N <br />� O <br />O <br />Q <br />OO <br />n <br />T <br />E <br />CDy <br />o <br />l0 <br />= <br />E B ?: <br />a <br />c <br />1 <br />U Q ca <br />JOB <br />NO: 22-08433-08426 <br />SCALE : AS NOTED <br />SHEET NO. <br />D1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.