My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36387 Camp Fire Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36387 Camp Fire Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 7:14:15 PM
Creation date
2/19/2025 2:21:39 PM
Metadata
Fields
Template:
Building Plans
Street #
36387
Location
Camp Fire Ter
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�_4t <br />I "DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />CONTINUOUS LATERAL <br />BRACING- NAIL OVER <br />X-BRACE AS SHOWN - <br />INSTALL BLKG. AT TRUSS <br />WEBS FOR NAILING - <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />SEE -ROOF <br />PLAN F- SHEATHING <br />BLOCKING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />X-BRACING - 2x4 SPF OR <br />SYP w/ 2-16d @ EACH TRUSS <br />WEB <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />USSES <br />(2) 12D NAILS -' <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL 2 <br />SCALE: 1 /2"=1'4' <br />TRUSS NOTES. <br />TYP. HAND FRAMING ABOVE TRUSS <br />CONY. FRAMED RIDGE 2X4 STUDS & PLATES AT 2'-0" O.C. <br />1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />MAY BE NAILED EACH DIRECTION TYP. U.N.O. <br />TRUSS PLATE INSTITUTE NOTE THAT THE COMBINED WIND AREA IS GREATER <br />( ) <br />w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS 2x8 BLKING. NAILED @EACH <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />WH <br />SIDE w/ (3) 12d NAILS WHEN <br />WHSIMPSON <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />REQUIRED w/ (2)NAILS <br />HTS20 <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />W/ (14) - 10d X 1 1/2" EACH <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />�C <br />2. <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />Cg <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />5. <br />PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />PRE-ENG. TRUSS <br />-- 2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX & EACH END ALTERNATE <br />DIRECTION TYP. " <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />HIP <br />G.T <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />DIAGONAL 2x8 #2 SPF RIDGE BEAM <br />AT 8'-0" WOOD <br />MAX TRUSS 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. ATCONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />4L~~ _� SCALE: 1/2" = V-0" <br />WOOD TRUSS <br />'°` PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1/2"=1'4' <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />PROVIDE 25" LAP <br />(2) SIMPSON SDWC15600 SCREWS @ <br />= <br />SPLICE @ F.C. REBAR <br />EACH TRUSS TO LEDGER <br />1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE <br />2-M-W OSB (DRAFTSTOPPING) TO BE <br />- <br />NAILED W/8d COMMON @ 6" O/C TO ONE <br />TOP -CHORD BEARING <br />SIDE OF THE FLOOR TRUSS FOR AN ARE <br />FLOOR TRUSSES @ <br />:5 1000 SQ. FT. OF <br />24" O.C. <br />FLOOR AREA & SEALED —_.- <br />PENETRATION AREA W/ <br />2) 2x8 SYP #2 P.T. <br />FOAM. DRAFTSTOPPING <br />LEDGER ATTACHED TO <br />SHALL DIVIDE THE <br />MASONRY w/ (2) ROWS <br />CONCEALED SPACE INTO <br />5/8" SIMPSON TITEN HD, <br />APPROX. EQUAL AREAS. <br />MIN. 5" EMBEDMENT @ <br />24" O.C. STAGGERED @ <br />12" O.C. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />F <br />IN EACH COURSE. <br />FLOOR CONNECTION aC� EXTERIOR WALL <br />SCALE: 3/4" = V-0" <br />2'-0" MIN. <br />LAP SPLICE <br />1'-01, 6" <br />6" 1'-0" 6" <br />01 <br />6" 1'-01, <br />TYP. <br />TYP. <br />0 0 1 0 0 <br />0 0— <br />I SPLICE <br />0 0 1 0 0 <br />0 0 <br />2'-0� <br />SPLICE BEYOND <br />2'-0" <br />d <br />DBL. KO. BLOCK MIN. <br />fJ <br />MIN. TYP. <br />11 <br />[I <br />�] <br />�] <br />24" MIN. <br />(2)2x8 P.T. <br />ATTACHED <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICE TOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />_ PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />(2) ROWS OF 10d NAILS @ 4" O.C. <br />—FLOOR TRUSSES <br />@ 24" O.C. <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />(2) 5/8" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0"O.C.T&B <br />FLOOR ATTACHMENT r5O� <br />SCALE: 3/4" = V-0" <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />WOOD TRUSS <br />DETAIL - ADJACENT TO TRUSSES <br />MAS0 <br />SEE P <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />" <br />/n\ 1nd Tl1CAIA 11 Q <br />2X6 P.T. CONT. <br />LEDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />D.C. T&B <br />TRUSS <br />(6) .162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL _ 51 <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />W/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />MASONRY WALL <br />SEE FLOOR <br />PLAN FOR MORE <br />INFO. <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />MIN. 2x4 #2 SPF P.T. <br />CONT. W/ (2)1 x3" <br />TITEN2 SCREWS @ <br />16" O.C. <br />TRUSS O ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL 52 <br />SCALE: 3/4" = V-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />7 - DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING. <br />ELIMINATE 3/4 AIR SPACE. 2x4 BLOCKING @ 48" O.C. MAX. W/ //;:�0 LB FELT (SHINGLES) _-- <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION. (2) 16d TOE NAILS @EACH END FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK SHEATHING 4' ON EA. SIDE <br />PRE-ENGINEERED ROOF RUNNER TO SHEATHING OF WALL NOT STAGGERED CEILING BOARD <br />TRUSSES AT 24" O.C. MAX OVER PARTY WALL <br />ABOVE AT EACH SIDE <br />2X4 LEDGER @ 48" O.C. SEE ROOF PLAN <br />MAX VERTICALLY NAILED FOR STRAP INFO. <br />(2) LAYERS 1"X24" PROPRIETARY TYPE TO TRUSS WEBS W/ (2) 8d BASE BOARD PER SPECS <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK RUNNER TO TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 1002. <br />STD 909 HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR <br />UL-U905 (see sht 9) LOCATIONS) <br />2 x P.T. BLOCKING BY FRAMER FOR PLYWOOD EDGE NAILING <br />w/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />(2) 2x8 SYP #2 P.T. CONT. LEDGER w/ (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE AND EACH END SEE 54/D1— <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ <br />8d COMMON AT 6" O.C. TO ONE SIDE OF TOP CHORD SRG. <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. FLOOR SYSTEM <br />AND SEALED PENETRATION AREAS W/--- <br />FOAM. DRAFTSTOPPING SHALL DIVIDE �- <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP. <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE — <br />FOUNDATION PLAN FOR LOCATIONS) <br />8" CONC. BLOCK (TYP.) PER UL905 - <br />1x P.T. BASE NAILER <br />6x6 W1.4xW1.4 WWF. <br />w <br />U <br />Z J <br />2Cn <br />a <br />LOQ_ <br />►ilE <br />(TYP.) <br />' <br />EXTEND BURN CLIPS AS PER <br />2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. <br />FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. <br />SPECIFICATIONS NAILED INTO <br />W/ (2) 1/4"x3" TITEN2 <br />0 o <br />2x4 LEDGER ONLY AT EACH <br />0 o <br />SIDE OF STEEL "H" STUD. <br />---------.--- - <br />�(1) LAYER 1/2" HIGH STRENGTH <br />(2) SIMPSON SDWC15600 <br />SCREWS @ EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" <br />LEDGER <br />DRYWALL NAILS OR DRYWALL <br />- <br />SCREWS 7" O.C. EDGES. <br />SIMPSON RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS <br />3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" <br />SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />- -- <br />AFTER INSTALLING RBC'S <br />1/2" GYP. WB OR 3/8" <br />8"x8"x16" CONC. KNOCKOUT <br />PLYWOOD/ <br />BLK. W/ 1 #5 ROD CONT. <br />TYPE 2-M-W OSB <br />FILLED W/ GROUT <br />(DRAFTSTOPPING) <br />4"x4" INSPECTION PORT AT <br />0 BE NAILED W/8d <br />- - <br />EACH FILLED CELL (TYP.) <br />COMMON @ 6" O/C TO <br />1x P.T. BASE NAILER <br />ONE SIDE OF THE <br />STD. 909 HOOK <br />FLOOR TRUSS FOR AN AREA :51 00 S . F <br />(SEE DETAIL) <br />OF <br />NAIL FLOOR TRUSS TO LEDGER W/ <br />FLOOR AREA &SEALED <br />4 10d TOENAILS (TYP.) EA. SIDE <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />- <br />SHALL DIVIDE THE <br />(2) SIMPSON SDWC15600 SCREWS @ <br />CONCEALED SPACE INTO <br />EACH TRUSS TO LEDGER <br />APPROX. EQUAL AREAS. <br />TOP CHORD BRG. <br />FLOOR SYSTEM. <br />PRE -ENGINEERED - <br />-- <br />FLOOR TRUSS' AT <br />- <br />- - - <br />24" 0 C <br />DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />- CONT. IN EA. COURSE FILLED W/ GROUT <br />1" P.T. NAILER <br />R-3 MIN. INSUL. PER. FBC. <br />1/2" GYP. WB. <br />TYP. "S" MORTAR (TYP.) <br />_U <br />Z M <br />ga <br />N <br />4"x4" INSPECTION PORT. AT <br />EACH FILLED CELL (TYP.) <br />o <br />/AI <br />• • <br />(4) #5 CONT.—STD. 90° HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) <br />2-STORY PARTY WALL SECTION(F"VlIIIliO' <br />SCALE: 3/4"=V-0" <br />REV. 05.24.23 <br />GYP. BOARD CLG. <br />SEE 5301 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. <br />(2)-1 X 4 P.T. <br />NAILER <br />BASE BOAR[ <br />PER SPECS. <br />CONC. SLAB <br />SEE FOUND. <br />6 MIL VISQU <br />TREATED; <br />SEE PLAN <br />TOP OF PLATE <br />TOP COURSE W/ <br />LINTEL SEE <br />to <br />PLAN <br />=- SEE PLAN <br />TOP OF WIN <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />10'-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />Ll G <br />T F.F. <br />00 <br />VARIES WITH <br />to SITE GRADES <br />SEE PLAN <br />CV <br />3 #5 CONT. <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />c•_r <br />N 0 <br />w <br />CD <br />� 4 <br />N d O fC <br />t CV � <br />� &E <br />� _ <br />3 m <br />N Q. 17 <br />C <br />Q <br />a. <br />-. 1L <br />/z �OPESS�Ot� <br />//Iwi`111 <br />f I I I I III,00\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />N <br />H g QE <br />O N V N <br />V N O 0) IIj � iM <br />MQ <br />0 'Coo <br />. <br />M rnnr;� LL w ' <br />(f) m a a a <br />a U_ U_ a� <br />-9 z <br />Zm -; <br />R & o <br />fY N� CoJ a <br />CS <br />N mow <br />z N Z U <br />, H <br />ILW <br />rV <br />z O U ❑❑❑ <br />Z <br />W <br /><= Q <br />v <br />��jj)�o <br />a <br />J C <br />I ` <br />C_ <br />�' <br />U <br />pv <br />O C N <br />�N <br />) <br />C) <br />J <br />nook <br />t <br />T <br />T <br />91 <br />N <br />am <br />mJ <br />rdE <br />- <br />U <br />E <br />Z <br />E <br />J, <br />z � <br />ZI <br />m v <br />4 51 <br />m <br />441,, <br />J <br />cn <br />V <br />cl <br />U <br />o Q <br />L <br />> 00 <br />U <br />co <br />rn <br />Co <br />Fes- <br />00 <br />M <br />U_ <br />M <br />T <br />T E <br />C <br />M <br />60 <br />v) U <br />O� <br />T <br />ca <br />r <br />T <br />}I <br />Q CD <br />LO <br />1? M <br />L o <br />C <br />r- N <br />00 a <br />00 MT <br />O <br />07 <br />CD <br />cD N <br />L f <br />CD <br />M <br />C0 <br />co �; <br />o <br />Z <br />Z <br />E t— <br />c <br />n <br />E _0 :? <br />U -1 Q 10 <br />C <br />3 <br />JOB <br />NO: 23-05713-015718 <br />SCALE : AS NOTED <br />SHEET NO. <br />D1 <br />