I I t I I I I ! L-11 I - I - 1 1 - - -L ---- L__L_ I _1_� a' -, 'L-B JU_L_L_ __ L_ - ff- 11 . 11 1 1 1 1 ] '— — I ----- J_ I — — I __ I I I I i I 1 11 1 1 --- L_ __ I _L I - - I ) <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with LIL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in LIL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14� Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />F� <br />I 'fE DUPLEX OUTLET ABOVE COUNTER <br />FITF <br />KDw.P. WEATHERPROOF DUPLEX OUTLET <br />4m,, GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />F 1. <br />FliisF HALF -SWITCHED DUPLEX OUTLET <br />L.r_'h SPECIAL PURPOSE OUTLET <br />F �_'>v <br />I= DUPLEX OUTLET IN FLOOR <br />:E:�F <br />I /'-� - 220 VOLT OUTLET <br />ff��E <br />IWALL SWITCH <br />$3 THREE-WAY SWITCH <br />6. <br />_�)4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />3:� CEILING MOUNTED LIGHT FIXTURE <br />771 HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />L.21 <br />I­_0 WALL MOUNTED LIGHT FIXTURE <br />@) RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />I I C)N, EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />PH] CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W1 ROUGH -IN FOR <br />OPT. CEILING FAN <br />GD (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />jt <br />LAV <br />-1 <br />"U fUB/ — <br />W/C SHOWER <br />LAV <br />3" VTR <br />JIL <br />OPT. <br />LAV <br />LAV <br />Lj W/C <br />_U <br />SHOWER <br />W/C <br />STUDOR DBL SINK <br />VENT t Lrj W/ DISP. <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS - <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />1 <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />3R <br />Cable <br />#4 Solid COPPER Ground <br />Q <br />C.O. <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />------------------------- <br />OUTDO\OR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT WP <br />GFI <br />I AT% <br />kue <br />nwwn <br />KITCHEN) <br />F — — — <br />�Fl ' Ez <br />U, <br />SWITCH F OR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />/,,>ROUGH -IN\ <br />FOR OPT <br />< *> FAN/LIGHT <br />=8 <br />FOYERI�. <br />DB <br />aB <br />ENtRY WPO— <br />LIGHTAS GFI& <br />PER SPEC�S�W��' <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />W <br />W Z <br />20 <br />W <br />LL <br />EE <br />W 0 <br />> <br />I <br />.1 UPSTAIRS t <br />GF1 <br />@ 44" <br />LW.H. <br />A.F.F. <br />0 <br />IGARAGE <br />I <br />GARAGE <br />LIGHT AS <br />TER SPECS <br />\,,GARAGE <br />=;E3 <br />DOOR <br />GFI <br />r-- — — <br />— — <br />— — — — — — — — — — — -- <br />Uj <br />Z <br />< <br />P: <br />_j <br />< <br />0 <br />> <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE: Y4"=1'-O" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />F__ __ — — — — — — — — — — — —1 <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: Y4"=V-0" <br />ell— <br />C"I <br />Co C-7 ,14 <br />Cn -0 cc <br />Lj '0 <br />C' W <br />C:2 <br />W cc �;_ <br />r- _C3 <br />ra <br />C41). <br />CD <br />2! <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions <br />of the drawing pages beanng <br />Engineers signature and seal. <br />W <br />4 <br />E 8 c,4 <br />co 8 <br />C14 <br />C'j <br />0 <br />LO <br />N 0 a, Lu <br />U_ <br />M <br />Z <br />0 <br />0. <br />W <br />0 <br />0 T 0, 1 r- Z <br />W <br />Z <br />00 0 x 0 Lu <br />LO M Z 5 U <br />W <br />Z <br />< E3 <br />C-) I' <br />W <br />0 <br />V) <br />C1 <br />4-1 <br />Ln <br />C) <br />C_ <br />__j <br />W, <br />E <br />E <br />0 <br />10 <br />ZE <br />t <br />U:) <br />Z <br />__j <br />C§ <br />I U <br />Q <br />C' <br />> <br />.0 C:) <br />Q 00 <br />> <br />co <br />T <br />0 <br />(D <br />CN <br />CID <br />LL <br />LO <br />CL <br />E <br />oo <br />W .2 <br />co <br />C\j <br />N— <br />00 <br />C14 <br />F— <br />0 <br />LO <br />M <br />U-) <br />00 04 <br />a <br />C:) <br />< <br />Q4 <br />to <br />CN <br />E <br />ce) <br />j6 LO <br />0 <br />M <br />Z <br />E <br />ca <br />Q. <br />E <br />0 0 <br />1 0 _j <br />'a cc <br />< 0 <br />C <br />0 <br />_j <br />JOB <br />NO 23-05747-05752 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />