ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f ® <br />SPECIAL PURPOSE OUTLET <br />17-9 <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4 � <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />,�, <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�[]eD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />N 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />_M=L <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />JAL <br />�I <br />r <br />LAV <br />u -_ - <br />TUB/ <br />W/C SHOWER <br />LAV <br />3" VTR <br />jj� <br />OPT. <br />LAV <br />AV <br />u W/C <br />SHOWER <br />STU DOR <br />VENTI 1 DBL SINK <br />T W/ DISP. <br />I•L A <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10KWat o <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA 1 <br />200 AMP <br />CEEORA N <br />1A P Serial Cable <br />NEMA <br />3R <br />Power Co. Feed — -- 1-1 1 _ 1--.r- #4 Solid COPPER Ground <br />---------------- <br />OUTDOOR LIVING <br />C.O. <br />INSTALL LIGHT 'Y <br />ROUGH -IN /^ <br />FAN/LIGHT LOIGHT / WP <br />GFI <br />tm <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />0 <br />��QPGFI <br />7 <br />NJ <br />DINING <br />KITCHEN <br />I <br />FI �0-� J <br />ZI- <br />— — <br />W <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />`' /ROUGH -IN\ <br />��_ FOR OPT. <br />FAN/LIGHT I <br />y <br />I <br />I <br />I <br />I <br />I DB <br />ENfiRY I WPo- <br />LIGjiTAS O GFI� <br />PEF SPECS <br />DB&GFITO <br />BE ALIGNED <br />VERTICALLY <br />LU <br />H <br />\ W Z <br />>OQ <br />\ >_jm <br />C.M <br />1 UPSTAIRS C <br />` W.H. <br />\ O <br />I \ <br />I <br />IGARAGE <br />I <br />\ GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />F------ <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL —UNIT—A 1532 <br />SCALE: Y4"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />0. BATH <br />j BATH 2 <br />--\, 7 <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />OWNER'S <br />BEDROOM <br />`' (ROUGH -IN <br />�FOR OPT. <br />FAN/LIGHT <br />I <br />I S.D <br />Al <br />LOFT Ld <br />C.M <br />S.D. <br />I <br />I <br />"(ROUGH -IN <br />1 FOR OPT. <br />\ </ ,JEAN/LIGHT <br />�EDROOM 2 <br />2ND ELECTRICAL — UNIT —A 1532 <br />SCALE: Y4"=1'-0" <br />ers <br />ems+ <br />C <br />a <br />w <br />> W <br />1 n t o <br />c cavn <br />m ,.c <br />a- <br />= �o 0 <br />Q N X <br />2 <br />E c <br />w o c' <br />Ce �' ' 3 m <br />� u u <br />�c <br />m <br />N <br />c E <br />m <br />� <br />d � <br />M <br />N <br />a <br />N <br />N <br />i <br />0 <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />W <br />N m <br />r <br />rA <br />C <br />O N N <br />I`Pi <br />LL LL <br />to rp n 'Z J2 <br />N � rNi a <br />uJ w <br />w a <br />a J L � <br />IZ Y Z <br />z <br />z �_ <br />0 <br />N (0 <br />a <br />co wW <br />coW <br />rn <br />) <br />IL <br />wOiooEN <br />z O (5 <br />❑El❑ <br />W <br />00 <br />` p Q <br />n ,r, <br />^V) J[\. c <br />W C� <br />(7) <br />U <br />O w o <br />V) r_ �' <br />•� <br />C- <br />I IJ J <br />f <br />8 <br />—0 <br />o <br />C <br />M <br />In <br />U_ <br />E <br />pE <br />" <br />o a <br />•= N <br />PJ <br />E u <br />F_ <br />Y <br />. <br />❑ <br />E <br />=Y <br />m <br />r <br />'". <br />Z <br />A s <br />W <br />> _ <br />o <br />m <br />^ IY <br />o <br /><<sl <br />' <br />., <br />0 <br />.= o <br />2 <br />U <br />rn <br />CN <br />cc <br />o <br />Co <br />L F- <br />fV <br />cN <br />=3 N L TL_ <br />o <br />ll'7 <br />CIL <br />E <br />Cn <br />00 <br />m <br />N <br />l.f� <br />N <br />QO <br />LO <br />o <br />ca'o <br />ui <br />E <br />m <br />c <br />z <br />Z <br />E <br />E <br />m` <br />a <br />U _j Q O <br />JOB <br />NO: 23-05725-05728 <br />SCALE : AS NOTED <br />SHEET NO. <br />11.1 <br />