Laserfiche WebLink
I J I .__ LI _..� L 11. . 1 1 II II__ <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH /— WALL SHEATHING <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN I 16GAx1-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN I VA O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF I <br />HOME H C G <br />GARAGE SIDE O O 0 <br />5-0" Q - <br />STUB -OUT FOR " <br />O 1'-0"GAS <br />o <br />GAS METER U <br />o <br />N or <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCIeJoist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 112" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />FILL CELL <br />STD. 90° HOOK r— BOND BEAM <br />w <br />> STD. 90° CONT. #5 <br />CONT. #5 HOOK - - BAR <br />BAR <br />#5 CONT. <br />---- - --- _ - -- FROM <br />_ <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />BASE PLATE <br />ll <br />BEARING COLUMN I I �CONT. <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />_FOR <br />f BLOCKING/TJI <br />'--MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />N.T.S. <br />Filler blocking 1/8" min. } Small gap 2" min. <br />* 2" max. 4" max. <br />1/8" gap Web Stiffener Fastener Schedule <br />Joist Bearing- Location <br />Series Depth End Intermediate__ <br />9-1/2" 2-8d 2_8d <br />�2 BCI 5000s R 11-7/8" 2-8d 3-8d <br />F 14" 2 8d 5-8d <br />Clinch nails <br />J <br />9--1/2-- "--2-8d <br />� <br />2-8d <br />when <br />� <br />�' <br />BC16000s@r11-7/8„ <br />2-8d <br />3-8d <br />- <br />possible <br />i <br />O�� <br />BCI6500sR <br />14" <br />2-8d <br />5-8d <br />„ <br />1 16" <br />2-8d <br />6-8d <br />1) <br />Support back of web during nailing to prevent damage to <br />% <br />11-7/8" <br />2-8d <br />3-8d <br />web-flange <br />BCI 60s® <br />_ <br />2 <br />Block solid between joists for full length of span. <br />betwe between g p <br />Tight <br />9 <br />16" <br />2 8d <br />3) <br />Leave 8 gap between top of filler blocking and bottom of top flange. <br />\ <br />1116" <br />13- 6d <br />3-616d -� <br />4) <br />Place joists together and nail from each side with 2 rows of 10d nails <br />2x4/PI ood/OSB web stiffener - <br />Y�' <br />2" min. <br />4„ <br />® 14" <br />BCI 90s _ <br />15-16d <br />5-16d _ <br />required when Indicated or max. 16" 6-16d 6-16d <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGYs" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />— <br />DOUBLE Birdsmouthth cuts. DOUBLE JOIST CONNECTION top flan joist. <br />. N.T.S. <br />- Under 2nd floor C^ll Imn w/ lnaric <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing walls <br />Load bearing wall must stack <br />*Non -stacking walls over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />area =2 of high <br />s 0 9 <br />= <br />r-2 ink <br />0 0 sinker <br />lateral load. <br />1 <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) I <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES ---� <br />DO NOT cut, notch <br />or drill flanges <br />Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over _ <br />% blocking and wall or beam below.* — -� <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />ME (O (o <br />611 A 1)12" ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT #ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN %" <br />Round 1 <br />4, <br />Z <br />8 <br />8 M. <br />10 <br />11 <br />12 <br />PwittmaAw Hale Skie In <br />2 <br />3 <br />5 <br />6 <br />it <br />9 <br />10 <br />Any 16" joist <br />Span (ft) <br />8 <br />V-0" <br />V-1" <br />1'-2" <br />1' 2" <br />1'-3" <br />V-3" <br />T-T' <br />V-11" <br />24" <br />7_9" <br />3-2" <br />3'-T' <br />12 <br />V-0" <br />V-1" <br />1'-2" <br />V-2" <br />V-3" <br />V-9" <br />24" <br />2'-11 " <br />3-T' <br />4-2" <br />4'-0" <br />64" <br />16 <br />V-0" <br />V-1" <br />1'-2" <br />1' 2" <br />1'-T' <br />2'-5" <br />3-2" <br />3-10" <br />4-9" <br />5'-7 <br />6 4' <br />T-2" <br />20 <br />V-0" <br />1'--1" <br />V-2" <br />V-2" <br />2-0" <br />3-0I" <br />4'-0" <br />4'-10" <br />5'-11" <br />6-11" <br />7'-11" <br />8'-11" <br />24 <br />V-0" <br />T-1" <br />1'-2 <br />V-3" <br />2-5" <br />3-7 <br />4-9" <br />5'-10' <br />T 2 <br />9-4- <br />9'-6" <br />101-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN, SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S <br />SIMPS( <br />w/ (22) ' <br />NAILS 1 <br />5/8"0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />00 FINISH GRADE <br />Backer block (12" wide min.) -1 11=1 I 1=1 I 1=1 I = JI I <br />Nail with 10- 10d nails. --1 11-1 I I-1 I 1=1 I I— — <br />Install tight to top flange. <br />SLEEVE THRU STEM 11= <br />Joist hanger SEE PLAN FOR t a ., • <br />FOUNDATION INFO a <br />STEM FOUNDATION <br />�l GRADE REINF. SEE PLAN <br />Filler block. <br />Nail with <br />10-10d nails. <br />d <br />Backer block required where top a <br />mount hanger load exceeds 250 lbs. °=40 <br />Install tight to top flange. d-777-7 <br />✓ 1/4"-2" gap <br />II <br />i <br />- Backer Block �� - I A/C CHASE 4" PVC (2) 45 REBAR <br />"Top Mount" "Face Mount" SLEEVE THRU FOOTING <br />Backer block shall be tight Backer block shall be tight MONO FOUNDATION <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height TYP. FND. PENETRATIONS <br />requirements <br />7,^I SCALE: N.T.S. <br />X Joist <br />T <br />de th �o <br />P <br />I -JOISTS BUCKETS <br />N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A <br />° ° <br />- <br />(WHEN <br />w/ (18)10d x 1 1/2" <br />°' <br />_, = <br />REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />PLUMBING LINE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE PVC OR SCH40 SLEEVE <br />PENETRATION <br />� ° n <br />a a <br />I I I —I a <br />71�=��M=Fl <br />I�-I <br />- <br />I 1=1 I I I I I <br />SEE <br />FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4' -0" <br />CENTERED @ PIPE <br />PENETRATION <br />° <br />PVC OR SCH40 SLEEVE <br />/ r PLUMBING LINE <br />is � <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d ° a n° <br />I__IIT- <br />° � III=III <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />C" <br />0 <br />N <br />ti <br />Z = <br />a W <br />ono <br />G �O C3 N <br />xs Im re <br />__ <br />c"-a- <br />N fV O tr <br />yi z L <br />40 b O <br />om <br />t= <br />_ <br />d os� <br />tO y V � <br />y6.f •f <br />> c n <br />O� cc �.. <br />L. E <br />n, ty <br />ty <br />M <br />CV <br />0 <br />CV <br />c�D <br />CV <br />C=� <br />C <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />E. $ E 8 NNQ� <br />Q O f 1 8 N <br />� N � <br />R <br />0 � <br />_ <br />v <br />a c _J a Y � <br />J LL LL_ /7 Z <br />z <br />— <br />z O � <br />��3' � 21 <br />= f>7 N �_ m ui Q <br />0 <br />W 00 Z� z w <br />d o <br />Cl)U <br />LL <br />N tU F <br />z o d 000 <br />z <br />W <br />C, M <br />J N M <br />U) <br />to <br />(31 - IL <br />4-+ <br />0 w $ <br />U L <br />r 8 <br />I <br />U <br />-CJD <br />0 <br />0 <br />Lo <br />M <br />J <br />> <br />co E <br />- <br />z F; <br />o <br />caE <br />= 0 <br />CL <br />ZLL <br />d t <br />o <br />s� <br />7 K <br />�z <br />m <br />8 <br />WCn <br />� <br />Y <br />nw <br />z <br />JInJ_ <br />o <br />�J <br />��C <br />= <br />U <br />F_ <br />rn <br />0-4 <br />O <br />� <br />~ <br />Co o <br />N <br />CV jL <br />O <br />`n <br />Cr E <br />ri <br />T <br />T <br />50 <br />°° U <br />O <br />CN <br />p LO <br />Cv <br />m <br />Np <br />U-5 <br />.-. <br />'0 (? <br />Llf') <br />Q C:) N <br />O <br />O <br />N c 11.0 <br />r <br />mot- <br />m <br />T v; <br />z <br />z <br />E <br />�a <br />m <br />a <br />E v <br />v a o <br />_J <br />JOB <br />NO: 23-05725-05728 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />