My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36462 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36462 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:24:11 AM
Creation date
2/19/2025 2:25:18 PM
Metadata
Fields
Template:
Building Plans
Street #
36462
Location
Flats St
Contractor
Lennar Homes LLC
Building Plans - Permit #
6033
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />v, <br />x <br />m <br />LO <br />00 <br />0 <br />r") <br />Ln <br />0 <br />Vi <br />O <br />J <br />LO <br />O <br />I <br />N <br />m <br />00 <br />0 <br />M <br />LO <br />LO <br />cn <br />Q <br />r` <br />J <br />LO <br />0 <br />I <br />N <br />i[ <br />v7 <br />ED <br />Cr <br />Cn <br />cn <br />0 <br />3 <br />Q <br />N <br />N <br />v <br />a <br />0 <br />E <br />0 <br />v <br />J <br />N <br />N <br />ti <br />E2 <br />U <br />a <br />UI <br />a <br />a <br />0 <br />U <br />0 <br />L= <br />NM <br />CV <br />45 <br />0 <br />0 <br />a. <br />0 <br />N <br />0 <br />Q <br />m <br />v <br />cn <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOW BUCK <br />2) SEALANT JOINT <br />5 SEALANT FROM <br />q INSIDE EDGE OF <br />WINDOW FRAME <br />� WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />I Z/ <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTI( <br />1. Cut, fold up & temporarily secure) <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR <br />SELF -ADHERED FLASHIN <br />SHEATHING <br />BY LAPPING DOWN -, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING \ <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />SINGLE <br />JOIST <br />SELF -ADHERED - <br />FLASHING <br />DOUBLE <br />JOIST <br />WOOD BEAM <br />BELOW <br />SELF -ADHERED <br />FLASHING Q <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />2xFRAMEWALL-,-_� <br />PRODUCTS DETAILS <br />TILE FINISH---�� <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />1/2" DUROCK --_ <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as# in each detail that corresponds to the <br />numbered items in the list of Instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />8" CMU <br />-E-- <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />4" OR 8" CMU <br />d <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH) <br />4. Split the release paper using the ripcord (Split release on demand, <br />FILL WITH GROUT <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />a <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />a <br />Minimum) <br />SLOPED MUD BED <br />6. Fold as shown by arrows <br />ri <br />a <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />VINYL SHOWER PAN <br />_ <br />8. Mechanically fasten as necessary <br />SLOPE <br />1'4' PER PLAN <br />1'-0" PER PLAN <br />SHOWER SEAT <br />WEATHER RESISTIVE <br />BARRIER <br />107 <br />Q <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-V BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL <br />SELF -ADHERED FLASHING v <br />0 <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />aa.. <br />a a <br />= W <br />U <br />W w <br />2 rr, <br />~¢ Ir <br />Lu W <br />O <br />Z;U) <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />� DOOR ROUGH OPENING <br />SLOPE <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm: 30.5 cm) <br />include flashing as described in Section R703.4. <br />- 3/4%1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />NAIL BRAND OR EQUAL WEATHER <br />CEMT. FIN. <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />PROOF CAULKING <br />BUILDING PAPER <br />of draining to the exterior water that penetrates the exterior cladding. <br />SELF -ADHERED FLASHING <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />SUBFLOOR <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />i <br />l <br />= <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />L <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />RIM Jolsr <br />SN <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />1 <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />2 <br />O <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />1 <br />SELF -ADHERED FLASHING <br />LIM <br />CEMT. FINISH SILL/ POTSHELF/CHIMNEY SMOULDER <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />INSTALL SELF -ADHERED <br />FLASHING JAMB &HEAD <br />NEEDED IN CORNERS ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED <br />prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF -ADHERED FLASHING, <br />�'a <br />(BEFORE FOLDING, SCORE <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />EXTEND A MINIMUM 6" <br />RELEASE PAPER TO EXPOSE <br />ADHESIVEASSHOWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />BOTTOM OF FROM <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD <br />shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />2 <br />following: <br />5 <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />1 <br />6 <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />2 <br />7 <br />subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />lo st <br />SELF -ADHERED FLASHING m <br />a <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />INSIDE CORNER <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1 <br />6.6.At wall and roof intersections. <br />coat r Rst t Barrier <br />7.7.At built-in putters. <br />:LF-ADHERED FLASHING <br />TCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />4 <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />- , I 3-1/2" INCH FLANGE <br />-_--- 1 <br />�Iv II rlv <br />PLASTER STOP THIS <br />NATU <br />DO NI <br />CONTINUOUS BACKER <br />ROD & SEALANT DRIP <br />ACCE <br />A <br />SOFFIT/CANTILEVER <br />e esan <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING, 'OSB', PLYWOOD, DENSGLASS <br />2AL FRAMING <br />2AL SHEATHING <br />3AF <br />PLANE WRB <br />AK WRB <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />1� <br />I� <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTM C1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />�.e <br />CM <br />04 <br />C= <br />Q <br />� w <br />U- <br />= " <br />E <br />=. <br />O <br />N <br />N_ <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />N <br />W <br />E <br />M <br />a o 8 <br />� N r <br />Co <br />0 oo <br />a <br />N l�Np <br />h" <br />t�i <br />4 N M 7 <br />C LL <br />-I <br />coLL� a <br />0 <br />Z - d a <br />L (0 <br />w q o <br />W 05 m <br />Z00 <br />MZ a J <br />Z N OU 6 C) <br />- W ❑❑ <br />o <br />� N <br />z � <br />Q <br />N <br />U) a <br />M <br />Vn)' 2! a <br />W 0(D o <br />4-, <br />O <br />w o <br />cn R <br />�N = <br />l✓ C <br />W J <br />=Ij® <br />0 .. = L N <br />7 <br />c n <br />Q N <br />Illl, <br />f9 <br />w <br />M <br />M <br />Z ¢ <br />p Y5 <br />Z <br />Z <br />Q <br />EE <br />sa 0 <br />=o <br />w°<� <br />zo <br />? <br />H- rp <br />g g <br />00 <br />a <br />o <br />a< <br />�z <br />� ITT <br />._om0 <br />0 <br />C <br />U <br />z <br />Z <br />.__I <br />m <br />etl <br />Q W <br />1 <br />:5- <br />a <br />g <br />z <br />gz <br />o <br />W <br />CD <br />oLL <br />az <br />m <br />a 2 <br />'7 <br />�3 <br />_ <br />as <br />Wo <br />o <br />Wo <br />v <br />o�Q <br />a <br />° 3 <br />yO <br />Ii <br />L i <br />L i <br />0 <br />Q/� <br />� <br />L <br />Ln <br />:3 <br />LO <br />r <br />T <br />W <br />_ <br />Q <br />m <br />a-1 U) <br />' <br />LO <br />m N <br />O <br />00 <br />ILL.N <br />N <br />LO <br />M <br />r <br />r <br />E <br />CO r <br />c C� <br />Z <br />cc <br />Z <br />E Occ <br />rp <br />E a N <br />U <br />C <br />c <br />o- <br />Q p <br />°i <br />JOB <br />NO: 23-00527 <br />SCALE : AS NOTED <br />SHEET NO. <br />WP <br />Ik Hill { _,, „I <br />
The URL can be used to link to this page
Your browser does not support the video tag.