Laserfiche WebLink
U <br />0 0 O, O v'v ,vv•a, ,vya< <br />8F8-18/1T 8F8---�0B�J/1T <br />O�J dvv, v <br />O O O O O O <br />8RF14-1B/1T8RF14-0B/1T 8F16-1B/1T <br />dO <br />v dv <br />v � v <br />O D vv v <br />8FB/1 16-OT 0 <br />U <br />OO O O O <br />8F20-1B/1T 8F20-0B/1T <br />O 0 <br />< �10:_< O<Av<�A <br />TYPE DESIGNATION <br />#SREBAR <br />ATTOP <br />F = FILLED WITH <br />IN. <br />(1) REQ'D <br />GROUT / U = UNFILLED <br />112" <br />a ° <br />R = RECESSED <br />CLEAR <br />QTY. OF #5 <br />0 <br />REBAR @ BOTTOM <br />° <br />OF LINTEL CAVITY <br />8F16- B/1T <br />H <br />Q <br />J <br />° <br />80 <br />�E� <br />z <br />° ° <br />GROUT <br />tNOMINAL. QUANTITY OF <br />5 REBAR AT <br />WIDTH #5 REBAR AT <br />° O <br />BOTTOM OF <br />TOP <br />LINTEL CAVITY <br />NOMINAL <br />BOTTOM REINFORCING <br />HEIGHT <br />PROVIDED IN LINTEL <br />7-5/8"ACTUAL <br />(VARIES) <br />8" NOMINAL WIDTH <br />MATERIALS <br />Ic precast lintels = 3500 psi. <br />Pc prestressed lintels = 6000 psi. <br />§routed per ASTM C476 fg = 3000 psi w/ <br />+haximum 3/8" aggregate and 8" to 11" slump. <br />Eoncrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />Rebar per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />270 low relaxation. <br />7/32 wire per ASTM A510. <br />Mortar per ASTM C270 type M or S. <br />GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7132" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with vertical (gravity and uplift) and horizontal (lateral) <br />loads should be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load <br />O <br />Safe vertical load Safe horizontal load . <br />ALTERNATE POWERS <br />STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D 1.1/2" CLEAR <br />J <br />w \\� <br />H C.M.U. <br />So U U) <br />xOWw <br />wL0? <br />oU)4J <br />rr L_1 <br />u <br />0 <br />o w #5 REBAR AT BOTTOM <br />Q O xQ MIN. (1) REQ'D <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting. <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required top and <br />bottom of all Powers Steel lintels. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitious coating. See contractor specifications <br />— <br />y <br />•a o 8RF6-OB/1T <br />•o <br />• <br />av <br />.•O.v. <br />• <br />O O <br />O, <br />8F20-1 B-2T <br />O O <br />O O <br />8F24-1B/1T <br />8F24-0B/1T <br />0 <br />0 <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />10 <br />10 <br />IN <br />2ND FLOOR LINTEL PLAN <br />SCALE: 3/16"=1'-0" <br />IN <br />SYMMETRICAL <br />(�)MIN. OMIN, OMIN. <br />MIN. MIN. MIN. <br />1ST FLOOR LINTEL PLAN <br />SCALE: 3/16"=1'-0" <br />SYMMETRICAL <br />�r <br />CM <br />9 Lu <br />CM <br />N � CV <br />CU � i3 <br />C::C <br />E <br />�21 Q <br />M <br />CV <br />O <br />N <br />Co <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications <br />contained within <br />these <br />drawings comply with the 2020 Florida <br />Building Code <br />- <br />Residential 71h Edition. Engineer's <br />signature and seal <br />is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />r ^ 5 <br />_ W <br />E S <br />V <br />N N CA � 9k W <br />0 <br />=�-LL <br />to <br />J) '- IJi <br />w <br />2 y <br />Q <br />N O 0 w <br />aj M V w 4 <br />a6; <br />co LL LL 4 Z <br />J <br />0M <br />r <br />A' <br />Lu <br />0< <br />W <br />W <br />o° <br />c?.JKz <br />LLmZ <br />oxOw <br />U <br />ZN <br />❑m <br />O ❑❑aoH <br />U <br />Z <br />W <br />allillillim <br />N Mp <br />O O <br />z <br />N <br />z o � <br />d <br />rs <br />- N <br />M <br />GA <br />cn <br />O <br />V) <br />ij o <br />w <br />to <br />C) <br />LU <br />E <br />N O <br />I <br />l� u <br />O N <br />C d <br />O <br />Q N 0 <br />Jw <br />co <br />M <br />M <br />Z C <br />o <br />F. <br />Z <br />Q <br />crr E <br />=o <br />oo <br />�ty <br />a� <br />E= UU <br />oa <br />Fc6 r6� <br />�` <br />-o <br />o� <br />O <br />co <br />a O <br /><Z <br />0 Z <br />wz <br />cn <br />� <br />aZ <br />oo <br />mo <br />Z <br />DO li <br />QZ <br />gzo <br />g <br />� <br />� <br />M <br />°off <br />w <br />ao <br />aZ <br />w <br />= <br />all <br />Z <br />= <br />H <br />M <br />v <br />zl¢ <br />ov 3 <br />c O <br />0 <br />rn <br />m <br />CN <br />H <br />G'VCo� <br />T <br />LO <br />� N <br />'� <br />N <br />C <br />�.� <br />60 <br />U <br />(1) m <br />E <br />U <br />T <br />N <br />CN <br />O <br />Lc� <br />M <br />LO <br />I'llO <br />M <br />,6 <br />r <br />0) N <br />- <br />Ln <br />r <br />ai <br />M <br />o <br />r <br />z <br />z <br />E r <br />a <br />m <br />d <br />o <br />U J <br />Q <br />J <br />JOB <br />NO: 23-03667-03672 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />L 1 <br />