Laserfiche WebLink
STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN = 14'-2" <br />�c <br />CD <br />OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />BATHROOM 2 <br />SCALE: 3/8" = V-0" <br />42" KNEE WALL <br />WITH 1x8 CAP & <br />CASING (AT 2nd <br />FLOOR ONLY) <br />\ <br />\ <br />---------- -- <br />\ <br />\ <br />13 <br />6 <br />2x STRINGERS <br />0 <br />00 <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.Q. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 J <br />S.H. <br />13 <br />20 X 38 J <br />181 X 37 J <br />S.H. <br />14 <br />20 X 50 J <br />181 X 50 <br />S.H. <br />15 <br />20X63 <br />18JX621 <br />S.H. <br />16 <br />20 X 72 <br />18 J X 711 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 } <br />S.H. <br />1H3 <br />271/4X38 <br />26x371 <br />S.H. <br />1 H4 <br />27 4 X 50 i <br />26 x 50 <br />S.H. <br />11­15 <br />27JX63 <br />26X621/2 <br />S.H. <br />11­16 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 -1 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 JZ X 37 3/4 <br />S.H. <br />24 <br />37 a X 50 s <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S. H. <br />26 <br />37JX72 <br />3671X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 1 WIDE <br />S.M. <br />32 <br />54 X 26 <br />52 J X 25 J <br />S.H. <br />33 <br />54 X 38 J <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 621 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 J <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />(2) 2X8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. <br />\ w <br />\ U <br />Z <br />T. <br />HAND RAIL w <br />J <br />U <br />1 <br />TYP. STAIR SECTION_ <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />v� <br />_L F. FL. lyl <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />BLOCKING AS <br />REQUIRED <br />2x4 #2 SYP. P.T. THRUST <br />BLOCK W/(2)- 1/4"x 3 1/2" <br />3" FROM EA.. END.c. AND HANDRAIL D E TA I L <br />SCALE: 3" =1'4' <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34" <br />NOR MORE THAN <br />38" ABV. TREAD <br />NOSING <br />METAL HANDRAIL <br />BRACKET <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />M I <br />VERIFY <br />AC PAD LOCATION OF <br />A/C PAD <br />HB <br />19 <br />------------------------- <br />OUTDOOR <br />LIVING <br />0 <br />9'-4" CLG. A.F.F. <br />b <br />a <br />CONCRETE <br />-0" <br />16'-8" <br />6-8" <br />3'-10" 3`-10" 2'-8" <br />Y o <br />6068 SGD <br />°' ~ <br />® <br />®TitI' <br />00 <br />C <br />O <br />o <br />- <br />r22468 <br />REF <br />BF <br />oo <br />I <br />-1 <br />E0 <br />&-3" <br />3'-2" 6_7" <br />O OO <br />DINING N <br />KITCHEN W I �0 <br />N <br />9'-4" FLAT CLG. <br />9'-4" FLAT CLG. z <br />TILE <br />TILE Z 1 <br />I <br />I <br />SINKw/ I <br />fb <br />D/W DISPOSAL I <br />zo <br />r � I <br />L - - -J <br />FLRG. LINE <br />-------- - <br />2x8 WALL <br />8'-4" <br />6-0" T-8" <br />o <br />16" CNTR. AT 42" ;o <br />A.F.F. <br />1/2 WALL <br />co <br />CAPPED <br />1 <br />r <br />UP 2 <br />T <br />II <br />3 <br />I <br />Cl) <br />GREAT ROOM <br />5 <br />6 <br />9'-4" FLAT CLG. <br />CARPET <br />00 <br />14'4' <br />- ' 7 <br />co <br />cD <br />c° <br />o <br />9 <br />PW01 <br />D1 <br />10 <br />GG <br />TYP. <br />r- <br />S3 <br />11 <br />12 <br />2x6 WALL <br />LO <br />7'-0" <br />2'-8" 4'-4" <br />o <br />--- <br />r` <br />rn <br />CO <br />*NO UPLIFT* <br />- - <br />`o <br />PWO1 <br />FLRG. LINE_-_--_ <br />Q <br />00'� <br />N <br />z <br />jO r V V R <br />D1 <br />- --- -- - <br />S4 <br />. <br />TYP. <br />l , <br />co ; H1 <br />LL TILE <br />Y <br />FO ER <br />I <br />o <br />9'-4" FLAT CLG. <br />b 2868 <br />TILE <br />00O <br />OJ <br />00 <br />tt"• <br />in <br />1 <br />91_41� � <br />cv <br />Lfl <br />T.O.M. <br />T-4" <br />2'-6" <br />M <br />3068 <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />�A / <br />PROTECTION <br />O <br />WHEN REQUIRED <br />cM <br />PER FBC <br />2'-0" 4'-8" <br />1-CAR GARAG <br />E <br />-1 <br />-° <br />9'-4" FU <br />T CLG. <br />CONC <br />RETE <br />ENTRY <br />1 <br />9'-4" CLG. A.F.F. o <br />cv <br />cqv <br />CONCRETE in <br />v <br />O <br />r- - - - - - - - - - <br />------ <br />vo <br />I <br />1 <br />I <br />I <br />�� <br />I <br />I <br />I <br />I <br />I <br />� <br />I <br />I <br />00 <br />°O <br />j TYP. @ <br />j <br />0 <br />ra <br />F2 <br />I GARAGE <br />I <br />K <br />I <br />I <br />- <br />cq <br />I S4 <br />I <br />N <br />N <br />N <br />%6I' <br />I''oa,-71 r±AMAt'- <br />Mnno ® <br />STONE <br />VENEER <br />1ST FLOOR PLAN - UNIT-C 1624 <br />SCALE: Y4"=1'-0" <br />9 <br />c <br />i• <br />2ND FLOOR PLAN -UNIT-C 1624 <br />SCALE: A"=1'-0" <br />IR <br />E <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />Q <br />+29.7 / -32.2 <br />( <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />0 <br />SEE SN SHEET O SEE SN SHEET <br />140 MPH <br />INNOTE. <br />WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Ed. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT : : <br />• I A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR <br />2ND FLOOR <br />664 S.F. <br />970 S.F. <br />TOTAL <br />1634 S.F. <br />GARAGE <br />246 S.F. <br />LANAI <br />108 S.F. <br />ENTRY <br />98 S.F. <br />TOTAL SQ. FT. <br />2086 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />G.C.An TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />C <br />C11*4 <br />N! <br />W <br />�5_ <br />V Qr- C= <br />N� <br />rs.= � <br />� + <br />cm %3 . <br />c � <br />CJ <br />M <br />N <br />0 <br />N <br />0 <br />z o <br />J��f'3ti�'S5'ti41� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />1 <br />(0cli <br />E S N <br />N L <br />- 0 <br />_ <br />7�op N # LL 0' <br />M! <br />tl! <br />�rrV uJ W <br />m v <br />14 <br />� w o <br />c J a Y <br />Z <br />o <br />'Z <br />N <br />..a, <br />o <br />Z <br />LL <br />N U7 00 L Q <br />rn rn ¢ z <br />J Lu <br />r, Z U G H <br />4, <br />(5 <br />N <br />oL) oo❑ <br />iA.,- . ' W <br />M <br />Z (MV M <br />o <br />z 00 <br />Q Q <br />J <br />13 <br />U) <br />N <br />M <br />W <br />0 o <br />4--1 <br />� <br />V <br />O <br />o <br />V) <br />w <br />c <br />c <br />=� <br />U o 0 <br />0 <br />N <br />ti <br />� <br />M <br />M <br />J <br />J <br />zo <br />W <br />Z <br />Z <br />G <br />U- CC <br />c, E <br />E <br />zo <br />o0 <br />> N <br />4N <br />oa <br />F- <br />2g <br />Qo <br />o <br />Q E <br />�o ro <br />&0 <br />Q`; <br />WZ <br />wZ <br />�r <br />o� <br /><o <br />UD <br />O <br />M J <br />C U <br />.9 <br />mo <br />¢ <br />¢z <br />15 <br />o <br />Z. <br />Z <br />�i >? <br />o� <br />LL <br />go <br />a z <br />N W <br />M <br />dLL <br />001 <br />K <br />=1 <br />o <br />w1W <br />-o <br />MV <br />zl< <br />a <br />0 <br />3r-... <br />0 <br />co <br />N <br />O <br />I-- <br />Cfl <br />N <br />CO N <br />� <br />u <br />r <br />LV-0 <br />N <br />CN <br />I <br />2 <br />a <br />E <br />r <br />00 <br />M m <br />U <br />r <br />N <br />LO <br />o <br />04CID <br />CD <br />T <br />t- <br />t <br />M NI- <br />o <br />CU <br />:3r <br />N <br />z <br />z <br />E r <br />E <br />`m <br />c <br />ca a <br />U � <br />Q p <br />� <br />JOB <br />NO: 23-03667-03672 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />