My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36478-36494 Camp Fire Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36478-36494 Camp Fire Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:40:25 AM
Creation date
2/19/2025 2:26:10 PM
Metadata
Fields
Template:
Building Plans
Street #
36478-36494
Location
Camp Fire Ter
Contractor
Lennar Homes LLC
Building Plans - Permit #
6304-6311
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLG. HGT. _ — — <br />T.O.M._-- <br />AT GAR. <br />8" FRIEZE — <br />BAND <br />r 80 <br />'v <br />o_ <br />F.FL. — <br />LEFT ELEVATION - STANDARD (STD <br />SCALE: 3/16" = 1'-0" <br />12 <br />4.0E— ; <br />=i <br />FIBERGLASS <br />T-' --— SHINGLES <br />— — — — — — — — — — — ---------------------------------- ----------------------------------- <br />0 <br />TEXTURED 0 <br />13 SH <br />FINISH 13 SH <br />1. <br />0 <br />0 00 <br />=L. <br />16" BAND <br />1 T T,— <br />-�-- <br />------- <br />--- T.O. M <br />ti.. <br />`t <br />HDR. <br />co <br />_ <br />o <br />C9 <br />TEXTURED <br />b <br />FINISH <br />00 <br />0 <br />25 SH 25 SH 35 SH <br />RIGHT ELEVATION - STANDARD (STD <br />SCALE: 3/16" = 1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />I Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having a 7/16" head, or 1-1/2" long, <br />16 gage staples, spaced in accordance with ASTM C1063 or <br />C1787, or as otherwise approved. (Refer to sheet SN1 for the <br />engineered method for Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"-1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />cri \), <br />CV <br />O <br />� <br />N <br />.. <br />C <br />CD <br />�cuC.� <br />CD � <br />WW <br />s� i3. xi <br />E <br />1 <br />M <br />N <br />O <br />GN <br />to <br />0 <br />✓' <br />Lj <br />F <br />Y 3�+}iilili� L <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />r W <br />-'"• <br />r� ci <br />�E <br />8 <br />N N # rn <br />0 <br />co <br />w <br />M a d <br />Qaj <br />Z <br />V W <br />Z <br />rn 0 0 <br />.c m v 0 o <br />CO m J <br />W <br />UM <br />r Q1 <br />c°n � pj Ci a r Z <br />o w <br />o <br />Z <br />00 ❑OD <br />N M <br />o g <br />Z aaN <br />Z O Q <br />Q <br />J � <br />(Z <br />� <br />M <br />V1 <br />al(DM <br />z <br />c� <br />,, w <br />U <br />,O^ <br />v ' <br />u S <br />r.Ly N <br />f� <br />U c <br />— N p <br />Q N O <br />C <br />d <br />m <br />_M <br />J <br />w <br />z <br />W <br />m E <br />E o <br />zo <br />oo <br />wz <br />rm <br /><� <br />o° <br />1— r0 <br />O E <br />to <br />� <br />¢ Z <br />00 <br />U <br />° ¢ <br />W Z <br />ItCD <br />0 <br />c <br />m a�i <br />J <br />py, <br />ho <br />0 <br />Qz <br />w <br />�z <br />S <br />CO <br />o< <br />go <br />oil <br />Im <br />$ <br /><o <br />G <br />aE <br />.. <br />o <br />wF <br />�0 <br /><17 <br />c O <br />0 <br />>� <br />L�L <br />f <br />U <br />N <br />O <br />CN <br />CV <br />N <br />LM <br />04 <br />tL <br />r <br />� <br />a <br />E <br />r <br />60 <br />CO m <br />(� <br />T <br />N <br />� <br />� <br />N <br />Ln <br />M M <br />LA) <br />.� <br />1q, O <br />C� <br />Q T <br />M N <br />CO <br />Lf 7 <br />r <br />ai <br />E <br />E <br />M <br />o <br />o T <br />ri <br />Z <br />Z <br />c <br />I_ <br />N <br />c <br />a_ <br />U <br />Q <br />� <br />JOB <br />NO: 23-03667-03672 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.