STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />42" KNEE WALL WITH <br />1x8 CAP & CASING - <br />36" H. CONT. <br />GRASPABLE <br />RAILING <br />lx8 CAP & <br />CASING - <br />(3) 2xl2 <br />STRINGERS- <br />MIN. (3) 2x STUDS R <br />@ END OF LANDING <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS W/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O <br />LANDING FRAMIN( <br />(2) 2x HDR. <br />REQ'D @ EN[ <br />LANDING FOF <br />STRINGERS - <br />CONNECT TC <br />i15 <br />i �4 <br />i13 <br />M i12 <br />i <br />j9 1 <br />I(�(-10 <br />ig <br />I o l O ig STORAGE <br />z7 UNDER <br />STAIRS <br />6 1x TREAD <br />5 (TYP.) <br />i4 1x RISERS <br />IUD <br />3 00 (TYP.) <br />2 N 2x FRAMED 2x FRAMED <br />WALL WALL <br />1 , <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />16"o.c. AND 3" FROM EA. END. <br />*�IN <br />rIN <br />CONT. HANDRAIL <br />42" KNEE WALL RETURN TO <br />WITH 1x8 CAP <br />& CASING 3/4" PLYWOOD WALL DETAIL <br />_uf_ DECKING <br />FLOOR SYSTEM SCALE: NTS <br />TYP. STAIR SECTION <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '% inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertical) from the sloped lane adjoining the tread nosing, or finish surface of <br />9 Y P P 1 9 9� <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />W/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />1 <br />D2 <br />TYP. @ <br />CONERS <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />J <br />S6 <br />TYP. <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />DRYER VENT- <br />THRU ROOF. <br />HANSON BOX @ <br />36" A.F.F. <br />LAU N <br />8'-0" FLAT CLG. <br />TILE <br />25-0" <br />H1 A 6 <br />2O D2 <br />H1 B 6 <br />2>(K) <br />D2 <br />EGRES <br />TB 60" X 36" <br />- <br />SHOWER <br />c0 <br />16 4' <br />FIBERGLASS <br />SURROUND. <br />3'-4" <br />-- 5'-5" <br />OWNER'S <br />SUITE <br />- <br />BATH <br />" FLAT CLG. 2668- 1 <br />8'-0" FLAT CLG. iv <br />2068 <br />TILE = <br />_ <br />CARPET ih <br />u� <br />G.T, T <br />C30 30 <br />O 0 <br />4SH <br />- <br />R&S 1`3_l <br />------ <br />Al 11 <br />LL_P L S M <br />WIC <br />u)1 8'-0" FLAT CLG. 2068 <br />ml CARPET 2668 <br />TILE TO 7' 0 <br />A.F.F. <br />IV <br />2 4SH <br />'-0" T CLG. °0 <br />TILE 2468 <br />TP =--- - - TB BF <br />5-9" 3'-0" L T-3" <br />- 2668-I _ r' <br />+ I 4'-2" <br />@j I <br />U_ <br />w D. 42" HIGH 1/200 <br />I I I <br />;�: <br />F <br />cc WALL W/ ix CAP <br />DNI I I <br />14'-0" <br />CHASEI N <br />N <br />IuIisp®I®I®Im In <br />10'-2" <br />BEDROOM 3 <br />8'-0" FLAT CLG. <br />CARPET <br />G.T. <br />IA' A" <br />I I I I I Q <br />I I I I I <br />I I I I 1 00 <br />61514131211 NME MISS! <br />11'4. <br />3'-0" <br />0 <br />�v <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP 60 <br />N <br />H3 <br />W <br />=O <br />010 <br />WN O <br />0 <br />00 <br />F_ <br />N <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN Y-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS** <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />181X25 <br />S.H. <br />13 <br />20X38J <br />18JX37i <br />S.H. <br />14 <br />20X50517 <br />18JX50 <br />S.H. <br />15 <br />20X63 <br />18JX62J <br />S.H. <br />16 <br />20X72 <br />18JX71 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 J <br />S.H. <br />1H3 <br />271/4X38J <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 J <br />26 x 50 <br />S.H. <br />1H5 <br />27JX63 <br />26X621/2 <br />S.H. <br />1H6 <br />27aX72 <br />26X711/2 <br />S.H. <br />22 <br />37 4 X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />3671 X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />362X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 X 25 <br />S.H. <br />33 <br />54 X 381 <br />52 J X 37 34 <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52' X 62 1 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 112" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 114 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />e <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />RAG <br />(2) - 2X4 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />Follow Q/S4. See Plan for <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />AA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />+28.3 / -30.8 <br />CD <br />+28.3 / -37.0 <br />CE <br />+26.6 / -29.1 <br />CF <br />+26.6 / -33.5 <br />CG <br />SEE SN SHEET CC SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />SECOND FLOOR PLAN - B <br />SCALE: 4"=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter Private Swimming Pools <br />p 9 <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA 721 S.F. <br />2ND FLOOR LIVING AREA 807 S.F. <br />TOTAL 1528 S.F. <br />GARAGE 397 S.F. <br />LANAI 60 S.F. <br />ENTRY 30 S.F. <br />TOTAL SQ. FT. 2015 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />c� <br />Cv <br />0 <br />n -W <br />CL) <br />W <br />o � <br />a � o <br />C mcoM <br />c.e <br />®�roac <br />LZ t <br />2-= . <br />U11 = ® _ <br />s = a� <br />c� c <br />CD := <br />pv o� su c <br />c� c+ <br />W i C <br />it c=M <br />Vf it <br />c E <br />�0 0 <br />5i <br />M11,�<�1z, �a o i djJ <br />I<'V11 <br />ViJJ <br />i �2 > <br />d <br />.\ L <br />✓� ,» <br />0 pie <br />F <br />�"till <br />I K481a'- <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />a <br />v E <br />0 <br />' m c <br />O1 r <br />- J 0 <br />) 00 N 1-1 rb <br />00 <br />C J $ <br />u ti U W <br />n. <br />Z <br />WO <br />- a Y <br />c and <br />l� <br />o <br />y o <br />_ 'Fa N W <br />W <br />i°nLu <br />4t <br />Z <br />Co <br />J <br />- NZ a <br />M <br />N <br />QUMR Q <br />o" <br />Z <br />W <br />�CD <br />❑ ❑ <br />M <br />7 <br />Z N M <br />o � <br />Z N <br />v <br />J <br />n. <br />V) <br />Z a <br />C7 <br />0- <br />F, <br />i <br />w = <br />o �° <br />�° <br />V <br />_ <br />0 <br />Ln <br />w o <br />C w <br />UOL <br />�N <br />_ <br />U <br />E <br />- <br />o I <br />8 <br />= w � <br />=I' <br />U o 8 <br />m m <br />e <br />N M <br />I� <br />o <br />w <br />c <br />M <br />M <br />J <br />� <br />o <br />Z <br />z <br />Q <br />� <br />LL <br />W <br />po <br />Y N <br />< 2 <br />o <br />EU <br />ui z` <br />z0 <br />oa <br />F- r6 <br />o <br />o E <br />E . <br />K U <br />& = <br />U O <br />U <br />S� <br />= <br />Z <br />cD <br />-!D- It <br />w a <br />2 <br />A) <br />O <br />m v <br />Nm <br /><� <br />aw <br />�z <br />� <br />w <br />Qo <br />C. <br />aZ <br />�w <br />C. <br /><o <br />all <br />w <br />3 <br />=r <br />w< <br />;o <br />F <br />miM <br />-I <br />0. <br />d <br />OU 3 <br />=O <br />0 <br />= <br />a) <br />J <br />(� <br />O <br />m <br />rn <br />0 <br />co <br />T <br />f"r T <br />Co <br />r <br />00 <br />LO <br />O <br />L0 <br />LO <br />N <br />LO <br />T <br />a <br />O <br />L0 <br />T <br />M <br />o <br />Z <br />ca <br />E T <br />rn LO <br />c <br />c <br />a. <br />U J <br />Q p <br />J <br />JOB <br />NO: <br />23-06121 <br />SCALE: <br />AS NOTED <br />SHEET NO. <br />1.2 <br />