My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36529 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36529 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 3:16:01 PM
Creation date
2/19/2025 2:27:38 PM
Metadata
Fields
Template:
Building Plans
Street #
36529
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
6511
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cn <br />4J <br />I <br />x <br />Q <br />4 <br />J <br />N <br />0 <br />I <br />N <br />M <br />N <br />0 <br />0 <br />.�S <br />Q <br />3 <br />C <br />Q <br />N <br />N <br />8. <br />E <br />E <br />_ <br />J <br />0 <br />0 <br />J <br />a� <br />Li <br />N <br />N <br />0 <br />0 <br />a <br />N <br />0 <br />v7 <br />0 <br />f <br />d <br />DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />TO PRODUCT <br />1x4 <br />1/2" DRYWALL <br />TO PRODUCT <br />P T. <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />r 1x4 P.T. <br />1x4 <br />1 X 4 <br />FURRING <br />3-1/4" LONG X 3/16"0 <br />4 FURRING <br />3116"0 X 3" LONG <br />TAPCONS X 3 <br />FURRING <br />(2) ROWS 3/16" x 3-1/2" <br />TAPCON. INTO <br />STAGGERED @ 16" <br />TAPCON @ 16" O.C. & 4"L111X8 <br />X8 <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />1x8 P.T. <br />FROM EACH END w/ MIN. <br />2" EDGE DIST. ATTACH <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1 /211 DETAIL <br />1x8 w/ (2) ROWS 8d NALS <br />�� <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C. <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />1x4 <br />1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN. <br />TO PRODUCT <br />TO PRODUCT <br />2" EDGE DIST. <br />APPROVAL FOR CONN. <br />2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. <br />(2) ROWS 3/16" x 3-1 /2" <br />x 3-112" TAPCON @ 16" <br />O.C. & 4" FROM EACH <br />1x4 <br />❑ <br />TAPCON @ 16" O.C. & <br />END w/ MIN. 2" EDGE DIST. <br />FURRIN( <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" <br />2x8 <br />2x DETAIL <br />? 1/4" <br />DETAIL <br />STAGGERED @12"O.C• <br />3-1/411 DETAIL <br />BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL — <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45^ DIAGONAL (4)10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />INSTALL WDW, SCREW ANCHOR <br />INTO ARCH BLKG. PER <br />INSTALLATION DETAILS <br />1 /4" MAX <br />SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2 x 8 BUCK - CONNECT TO BLOCK <br />2'-0" <br />SECTION <br />A -A <br />8" <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />/4" MAX EMBEDMENT INTO .) <br />T-0" <br />BLOCK HEADER <br />SOLID BLKG. AT TOP BTWN. ARCH <br />1 X 4 FURRING <br />BLKG. &BUCK <br />8d NAILS @ 8" O.C. AT BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />PROVIDE 2 x 8 DIAG. BRACE B <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />LEAVE A CUT OUT IN O.S.B. ON TI <br />2 x 8 VERT. BRACE(S) <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />TO FIT ARCH CONNECT W/ <br />Sd NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />INSTALL WDW, SCREW <br />THRU OSB INTO 2 x 8 <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />ARCH DETAIL K <br />B-B <br />SCALE: N.T.S. SS <br />1/4" x 31/4" TAPCONS <br />--LEAVE A CUTOUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />\_ <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL 4' MAX. RAD. <br />PROPER INSTALLATION MAX. 8 <br />t - <br />FILL SOLID <br />BOTH CELLS <br />#5 REB, <br />(TYP,) <br />STD. 90' <br />HOOK (l <br />±5^ <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />.......,APACITY = 805 # FOR 1 STRAP <br />=1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7)1/4"x2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5)12d NAILS SIMPSON <br />2X6 TO 2X4 H2.5A w/ (10) <br />8d NAILS <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />I <br />GLASS BLOCK INSTALLATION NOTES <br />A) <br />COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) <br />ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) <br />SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) <br />SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) <br />INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL <br />PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) <br />EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />:;';;. <br />SEALANT <br />* PRESS PANEL REINFORCING INTO PLACE. <br />„ <br />6 MIN. LAP SPLICE W/ <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) <br />PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />ILAP <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MIN. <br />G) <br />SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />H) <br />STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) <br />AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) <br />APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) <br />A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAYBE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH —J <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" =1'41 SS <br />#5 CONT. TOP & MID <br />" <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />i <br />i <br />i <br />FILLED CELL PER <br />FOUNDATION PLAN <br />♦ UNACCEPTABLE INSTALLTION <br />♦♦♦ DO NOT DO THIS ♦♦♦ <br />i♦ <br />�R ♦♦♦ <br />YP.) ♦♦ <br />1♦ <br />.^. <br />fHE ♦♦ <br />S ♦♦♦ <br />#5 REBAR (TYP,) ♦♦♦ <br />1� <br />1♦ <br />90° HOOK (TYP.) <br />♦♦♦ <br />FILLED CELL INSTALLATION <br />SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />CCC dl!\TC 4 E)CI /V^f <br />BRG WALL TYPE <br />PER PLAN I I <br />2X2 #2 P.T. MIN, <br />FASTENED PER NOTE <br />2 BELOW <br />CONT 2x4 NAILED TO <br />BLOCKING w/ 2-12d NAILS (**) <br />ALUM DRIP EDGE <br />2x SUB FASCIA <br />L CONT VENTED OR SOLID SOFFIT <br />2x BLOCKING NAILED TO TOP <br />CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SIN. <br />2. 2x2 #2 MIN. P.T. w/ J-CHANNEL SECURED @ 24" O.C. FASTEN TO: <br />- CMU w/ 3/16"x3" TITEN2 @ 16" O.C. (ALT. PAF 0.145/0.157 & 0.300 WASHER W/ <br />MIN. 1" EMBEDMENT @ 16" O.C.) <br />WOOD w/ 0.148"x 3 1/4" @ 16" O.C. <br />3. IF] CHANNEL APPLICATION: 2X2 NOT REQUIRED SEE (PA) INSTALLATION GUIDE <br />/ <br />STRUCTURAL SOFFIT <br />SF01 SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS 71'-4" <br />REV. 09.10.2021 BLOCKING REQUIRED, FOR SOFFITS < V-4" <br />MID BLOCKING NOT REQUIRED <br />FOR VINYL SOFFITS > V-0" SHALL HAVE MID <br />BLOCKING PER R704.2.1 <br />i <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />W.W,M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />WITH MIN. 3 COVER 6'4- <br />10 <br />IU."111 Wit I tr <br />► e — — <br />1 <br />►e <br />• 'a <br />GRADE :► G •n <br />e <br />M ► <br />Z <br />N �► . ' <br />• e' <br />° (2) #5 REBAR. (1-STORY) <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />REV. 07.28.21 SCALE: 3/4" = V-0" <br />2x <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />PRECAST LINTEL <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2X4 SCAB FOR 7-6" TO 4'-0" O.H. <br />CF/I/O�h (2)1Old NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />PLYWOOD SHEATHING <br />BLOCKING AS <br />+ REQUIRED TO <br />+ + <br />+ SUPPORT SOFFIT <br />SO <br />I , IfJ11J' SEE ELEVATION ' <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION rm <br />SCALE: 3/4" = V-0" SS <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: <br />CFF CHFFT m Akin <br />z <br />O <br />a <br />U_ <br />O <br />L11 <br />F- <br />U <br />@ FIRST COURSE <br />i♦ <br />ii <br />H <br />SS <br />2"x BOT. PLATE W/ (2)1 Od @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED — <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />,-2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAM10KTA @ 12" O.C. <br />w/ (4)1/4x1 1/2" SDS SCREWS <br />INTO BAND JOIST & (4)1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />a, <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. • ° e' •� <br />OVERHAN <br />•� :a <br />a' <br />a,' <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR RECI'D. <br />1'-011 51-011 <br />INISH <br />SCALE: N.T.S. <br />• ' ' ► #5 BAR x <br />CENTERED W/ <br />► .:' a IN TOP o <br />► a ' KNOCKOUT / N <br />.; • CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN <br />AND SECTION DETAILS <br />CLEAN FILL .► ° e <br />DIRT b z <br />•,• • • STANDARD ED <br />90 HOOK N <br />#5 BAR IN <br />FILLED CELL,1. <br />, <br />,e <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. AND STEMWALL <br />SECTIONN DDETAETAILS <br />SCALE: 3/4" = V-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC' <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />4" SAW CUT <br />EXISTING FOOTING A SECTION <br />SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />O <br />N <br />Z <br />� <br />c W <br />ci a e p <br />a <br />Q C%i .2 <br />3 3 ro <br />. d Iv .= <br />q <br />c cm <br />a ry <br />N 'a -= <br />C � <br />4 t�i <br />e�����E�113IL v$Pfr�y� <br />Zv, <br />i]" a <br />Y L Jo'� <br />• <br />CMi <br />Q <br />C ti �C�' 7'- <br />•Z <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />W <br />a_ <br />v E <br />0 <br />8 <br />ii <br />0 <br />nl a m <br />UB101�_ <br />di <br />M :0 U. <br />0 J v LL 'L <br />Z <br />0 <br />JLLIL .a <br />-a°0, <br />ma <br />2 <br />m Gj <br />IL <br />zZ`ZNow <br />d � <br />Z <br />N OU U <br />W <br />❑ ❑ <br />M <br />Z N �pC, <br />z <br />v <br />J <br />(nul) <br />z <br />C1 <br />v <br />o <br />� a <br />l.1 <br />O,,,s <br />N <br />-N <br />C N <br />= Y <br />U <br />W J <br />t $ <br />i> <br />U o � <br />• <br />rMi <br />z <br />s <br />z <br />z <br />`° <br />zooZW¢ <br />o <br />C o <br />Z <br />ni <br />O E <br />E <br />o¢ <br />o <br />01 <br />z <br />w <br />¢0 <br />wo <br />wZ <br />M, <br />o <br />C <br />C <br />�z <br />z <br />U <br />mo <br />z <br />oLL <br />z <br />Z <br />m J <br />ro <br />¢ a <br />Q z <br />gZ <br />8 3 <br />0 <br />g <br />�W <br />W <br />m <br />CS� <br /><a <br />F <br />�o <br />8I� <br />0 3 <br />0 O <br />= <br />N <br />> Lo <br />m <br />ca <br />ca <br />c� <br />N <br />CU L <br />N <br />T <br />�•� <br />Y <br />/+ <br />T <br />a. <br />U) m <br />= <br />L:) <br />� <br />O <br />— <br />3: N <br />0) <br />CD <br />rn CN <br />Ln <br />T <br />LO <br />LO <br />M T <br />C;m <br />z <br />z <br />E N <br />N <br />�, <br />w <br />m <br />a. <br />E <br />U � <br />o a? <br />Q O <br />c <br />JOB <br />NO : <br />23-06124 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.