Laserfiche WebLink
FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />BARRIER <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />TEMPORARILY SECURE <br />DOOR ROUGH OPENING <br />WEATHER <br />SLOPE <br />RESISITIVE <br />BARRIER <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />P g P P <br />TAPE EXTERIOR <br />WOOD FRAME CONSTR <br />SELF -ADHERED FLASHI. NG 3/4%1" BEAD OF CONSTR. <br />(0.6 cm: 30.5 cm) <br />include flashing as described in Section R703.4. <br />3 SHEATHING <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND <br />(ASSEMBLED WINDOW) <br />WALL BY 6 IN. RETURN UP JAMB 6". USE LIQUID <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />z <br />NAIL <br />BRAND OR EQUAL WEATHER NAIL <br />CEMT. FIN. <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />WEATHER <br />CAULKING <br />PRO�- <br />O SELF FLASHING <br />BUILDING PAPER <br />of draining to the exterior water that penetrates the exterior cladding. <br />-ADHERED <br />2 RESISITIVE <br />BARRIER <br />SEAL TOPS OF JOISTS 1 <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />UNDER DECKING SUBFLOOR <br />(SEE DETAIL WP07) <br />_ , <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />PP Pp 9 P PP <br />SELF -ADHERED FLASHING <br />.. , <br />_ <br />horizontal) with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />y, PP Y pp Y J pP <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />HEAD FLASHING TIE-IN INSTsecure <br />No.15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />�. cut, fold &temporarily secure weather <br />eat <br />RIM JOIST <br />buildingappendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />q P <br />THESE DETAILS ARE GENERIC AND <br />a <br />resistive barrier above header to allow for <br />flashing installation <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />USED. <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />O <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathin shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />g°BE <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOWSELF-ADHERED <br />FLASHINGFLASHING <br />i <br />SELF -ADHERED FLASHING <br />1 <br />EXTERIOR DOOR WITH DECK - SECTION A <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />EXTERIOR SHEATHING <br />JI <br />3/4"-l" BEAD OF CONSTR. INSTALL SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD <br />NEEDED IN CORNERS ADHESIVE <br />ASPHALT ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />3/8" CEMENT <br />PLASTER <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />12 MIL DRYLOK CMU - MASONRY BLOCK <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />EXTREME <br />REFER TO TECHNICAL <br />SCORED <br />prevent the entry of water into the wall cavity' or penetration of water to the building structural framingcomponents. <br />P ry `' P g P <br />WINDOW <br />LETTER ON CHEMICAL O <br />COMPATIBILITY <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />FASTENER <br />1) SEALANT AT <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING, <br />�o (BEFORE FOLDING, SCORE <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />4) SEALANT JOINT WINDOW BUCK TO <br />EXTEND A MINIMUM 6' <br />PER TO EXPOSE <br />READH ADLEASE HESIVE OWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />OUTSIDE EDGE OF '' MASONRY <br />WINDOW BUCK t <br />° <br />VERTICALLY BOTTOM OF FROM <br />flashing in exterior walls shall comply with AAMA 714, The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />2) SEALANT JOINT <br />e <br />e ° ° <br />THRESHOLD <br />, <br />�- <br />shall be installed at the following locations: <br />5) SEALANT FROM INSIDE EDGE OF <br />z a <br />WINDOW FRAME WINDOW BUCK <br />ACROSS WINDOW BUCK <br />SECTION -A (SEE DETAIL WP02) <br />�-J <br />AND EXTEND TO WINDOW FRAME <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />MASONRY ATTACHED <br />PER CODE <br />° SELF -ADHERED FLASHING <br />O <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />AAMA 712. Flashing door be installed in the <br />6) TOOLED SEALANT REQUIREMENTS <br />2 <br />shall comply with at exterior window and openings shall accordance with one or more of <br />BEAD BRIDGING <br />following: <br />CLADDING AND WINDOW <br />FRAME <br />z <br />SELF -ADHERED FLASHING <br />5 <br />1.1 The fenestration manufacturer's installation and flashing Instructions or forapplications not addressed in the fenestration <br />g , <br />3) SEALANT WINDOW FRAME T <br />WINDOW BUCK ALL THE WAY <br />NAILING FLANGE 1 <br />O <br />4 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />AROUND, INCLUDING SILL. <br />DO NOT FLASH OVER 2 <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />6 <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />BOTTOM NAILING Q <br />O <br />(SEE DETAIL WP07) 2 <br />7 <br />subsequent drainage. Openings usin an flashing shall incorporate flashing or protection at the head and sides. <br />q 99 P 9 P 9 <br />FLANGE <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />SELF -ADHERED FLASHING <br />1 <br />SELF -ADHERED FLASHING <br />1 <br />SELF -ADHERED FLASHING . <br />, <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />FENESTRATION INSTALLATION AND INTERFACE <br />HALF ROUND WINDOW <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />SHEATHING <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />. <br />Water Resistant Barrier <br />7.7.At built-in gutters. <br />JAMB, SILL AND HEAD DETAIL <br />Lath <br />APPROVED SHEATHING <br />SELF -ADHERED FLASHING <br />Sheathing <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />APPROVED HOUSEWRAP <br />PATCH <br />STRUCTALATH TWIN <br />stucco <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />MEET PLASTER <br />3/4" CEMENT PLASTER <br />° a , <br />° ° <br />° ° <br />12 MIL (min) DRYLOK EXTREME <br />° ° <br />APPROVED FLASHING TAPE <br />DOUBLE <br />° <br />° ° ° <br />7/8" Cement Plaster <br />"V" SEALANT SOCKET WITH <br />JOIST <br />° a d ° < <br />° <br />TOOLED APPROVED SEALANT <br />SINGLE WOOD BEAM <br />° ° <br />Foundation Wall ° <br />in accordance with 7/8" Cement Plaster <br />JOIST BELOW <br />1 SELF -ADHERED FLASHING <br />u ° <br />ASTMC926 in accordance with <br />SELF -ADHERED FLASHING <br />° ° d <br />° ° <br />ASTMC926 <br />2 <br />° <br />° <br />Felt backed metal <br />3" MIN <br />- <br />k.:. ` lathe in accordance Felt backed metal <br />SELF -ADHERED SELF -ADHERED <br />4 <br />with ASTMC1063 lathe in accordance <br />FLASHING FLASHING O <br />2 <br />5 <br />With ASTMC1063 <br />Building Paper <br />' Building Paper <br />7/16" O.S.B. <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />SELF -ADHERED FLASHING ' <br />SELF -ADHERED FLASHING , <br />FOUNDATION WEEP SCREED <br />sheathing 7/16" O.S.B. <br />Metal . , sheathing <br />EXTRUDED SHOULDER <br />DECK JOIST <br />OUTSIDE CORNER <br />, <br />Flashing <br />Weep Screed <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL <br />�� <br />/ �j <br />Installed As Per <br />Manufact. Specs. <br />PRODUCTS DETAILS <br />TILE FINISH <br />I i STRIP OF SAF LEGEND <br />I 1 SELF ADHERED FLASHING (SAF) <br />Maintain Stampede or similar <br />Bottom of cauk bottom <br />DRAINAGE PLANE WRB DRAINAGE <br />RAINABARRIER EAPLLANE (DP) WEATHER RESISTANT <br />Weep Screed joint only <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />1/2" DUROCK <br />(WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER- - - <br />I I� I BOND BREAK WRB SELF FURRING (SF) LATH <br />n n <br />1 1/2 to 2 <br />Above Roof Weep Screed <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Q <br />I 1 PLASTER ACCESSORY <br />Sheathing Installed As Per <br />I_ SF LATH SHEATHING,'OSB', PLYWOOD, DENSGLASS ® <br />Manufact. Specs. <br />1'4" PER PLAN <br />z­7 <br />I <br />Detail Instructions <br />Iff <br />,- „ <br />1 0 PER PLAN <br />v <br />I I WRAP DP WRB ONTO <br />I I � THE VERTICAL <br />„ <br />ous <br />finish <br />Refer to the number marked as # in each detail that corresponds to the <br />P <br />I SURFACE TO TOP OF <br />Cement Plaster De nativeCeme <br />Decorative Finish <br />numbered items in the list o Instructions below: <br />I 1 I FLANGE AS AN AIR <br />in accordance <br />I BARRIER <br />with ASTMC926 ° o,. <br />o., , o, All inside and <br />1. Install self -adhered flashing in order as shown by numbers <br />SLOPE <br />8" CMU <br />I I 3-1/2" INCH FLANGE <br />I <br />over wood 2nd •o'p ••o,• outside corner will <br />floor <br />2. Install flashing and weather resistive barrier to form water shedding <br />- - <br />Q °a <br />--------------- - - J I <br />' ®•o,®• need to be miter <br />- <br />laps <br />4"OR8"CMU ° <br />�------------------ I I <br />•o cut and caulked all <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH) H ° <br />_ _ _ <br />Z <br />Z <br />1 I STRUCTURAL FRAMING <br />'�°•oe. °•4 butt joints need to <br />• o, o• <br />4. Split the release paper using the ripcord (Split release on demand, <br />-I-- ° <br />FILL WITH GROUT I::::I a <br />a <br />a <br />I. <br />" <br />� • o•®, eq'• becaulked using <br />' ° ° " <br />embedded in the adhesive layer) - for ease of installation and to <br />e,d i STRUCTURAL SHEATHING <br />Stampede or sim. <br />minimize scoring cuts <br />a ° ° <br />a <br />d <br />THIS GAP IS A RESULT OF <br />PLASTER STOP NATURAL SHRINKAGE. STRIP OF SAF <br />caulk for all <br />5. Remove all release paper per standard installation instructions and <br />° d a <br />_ <br />cn <br />Cl) <br />DO NOT SEAL <br />- - - - - - - - - . <br />CONTINUOUS BACKER i- ---- ---- a DRAINAGE PLANE WRB <br />adhere to substrate using a square piece of flashing material (6" X 6" <br />° <br />0 <br />U <br />ROD & SEALANT DRIP SCREED PLASTIC i I <br />Minimum) <br />SLOPED MUD BED ° ° <br />L'-' <br />_ <br />W <br />ACCESSORY I li BOND BREAK WR13 <br />I ; I <br />6. Fold as shown by arrows'- <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />° <br />8 <br />I�-I <br />a <br />LU <br />LILI <br />i SF LATH <br />fit tight to corner <br />VINYL SHOWER PAN L I ° ° <br />0 <br />, I <br />A iI <br />P ° <br />it <br />II <br />Note: <br />8. Mechanically fasten as necessary <br />° d <br />U) <br />I I <br />===`------ ' <br />The lath <br />SLOPE ° a <br />- <br />building paper and metal must be <br />(___ <br />Cement installed over the top of the weep screed. <br />d <br />° - ° <br />__________ <br />PLASTER STOP �� <br />Plaster <br />block <br />4 <br />CONTINUOUS BACKER ROD <br />over <br />d <br />a a <br />a <br />& SEALANT <br />1 st floor <br />CEMENTITIOUS FINISH <br />WEEP SCREED DETAIL <br />SHOWER SEAT <br />SOFFIT/CANTILEVER • <br />SCALE: NOT TO SCALE <br />N <br />Z <br />W <br />a <br />t0 y N <br />N as V- to <br />asQ <br />Q � N <br />F. 4J Gf <br />� F. <br />V) rL <br />CI), <br />CV <br />0 <br />CV <br />L <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />W <br />�£ <br />0 <br />8 <br />0 <br />N c c� r <br />��, <br />Ol <br />r'n��� <br />W <br />4 <br />tl <br />M <br />Co LLI� a <br />- -6nw <br />Z <br />L r6 � <br />O <br />O <br />ILW�2pjO' <br />ZZ <br />m w <br />tO N O Q F- <br />I- <br />� <br />V <br />N <br />OU <br />Z <br />W <br />CJ � <br />Z N M <br />� � <br />z <br />Z n <br />rz � <br />N <br />Ln <br />- <br />f7 <br />z .B <br />v <br />1 , <br />o <br />LL <br />w � <br />� <br />U <br />O <br />w 8 <br />C <br />�N <br />� <br />rUu <br />'- - E <br />L <br />I <br />Cn-0 <br />c <br />N <br />� <br />aZ <br />Zz <br />w <br />M <br />o3 <br />r <br />a <br />J <br />=o <br />g <br />E <br />ao <br />E U <br />o <br />oLL <br />� <br />z® <br />oa <br />ro <br />o <br />00 <br />Z�� <br />r <br />,0 <br />WZ <br />R <br />o <br />_ <br />m 0 <br />Z <br />Z <br />9 <br />Ln <br />m <br />¢ ZO <br />V7 z <br />0 <br />o <br />=o <br />az <br />W <br />8 SC <br />mMJ <br />¢ <br />yLL <br />mW <br />=3 <br />v <br />0. <br />a 3 <br />H <br />>Lo <br />c� <br />� <br />N <br />Co <br />LO <br />Cr <br />0 <br />L1 i <br />O <br />3:N <br />a) <br />to <br />Q <br />a) o <br />to <br />T <br />L` j <br />T" <br />LO <br />m <br />N <br />M ` <br />LLB <br />o <br />Z <br />Z <br />e IN <br />ti <br />U) <br />cc <br />E <br />U <br />w <br />� <br />a <br />Q <br />JOB <br />NO: <br />23-06124 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP1 <br />