My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36529 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36529 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 3:16:01 PM
Creation date
2/19/2025 2:27:38 PM
Metadata
Fields
Template:
Building Plans
Street #
36529
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
6511
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outiet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�--0 <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />,Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />© <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />10 #14 to lights & outlets <br />NEMA 1 <br />0 #12 to appliances and GFi <br />150 AMP/ <br />200 AMP <br />b #10 to WH <br />#8 to Range <br />10 #5 to HVAC <br />viT <br />n <br />200 amp <br />150 amp <br />UNDERGROUND Ois <br />SERVICE BY POWER CO.� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />r 7- �- — i <br />�I ALT II <br />I AC PAD I I <br />I� �I <br />OPT. <br />• <br />AC PAD <br />DISC. WP <br />GFI <br />`❑ <br />I <br />DINING <br />�o � <br />1 / <br />LIGHT AS PER <br />SPECS <br />PENDANT <br />LIGHT PER <br />SPECS <br />GREAT RM <br />r]� ROUGH -IN 12 FOR OPT. U.C.OUTLET <br />47 <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />■■ --- ■■ I-------------------� <br />• - LANA]---- <br />I I <br />I I I I <br />WP <br />GFFI / .lid I t I <br />77 <br />_ <br />BRKEST.I <br />O <br />LIGHT AS PER <br />SPECS <br />,GFI- <br />1 0- p� <br />`' <br />I€ <br />GFI <br />I -- <br />.�' <br />IGFI <br />I <br />I <br />o <br />- <br />s <br />SWITCH .. <br />-- -- <br />,o_ <br />.- <br />_ <br />C <br />•'LIGHT <br />DISPOSAL <br />Ill <br />111 <br />H <br />-_ <br />• <br />D <br />jj�� <br />• EL <br />FOYER GFI @ 44" <br />A.F.F. 1 W.H. <br />ZOZ <br />/ a <br />• • / �a <br />GFI <br />1�JI <br />a <br />ENTRY <br />/ 0 <br />GARAGE <br />L <br />LIGHT AS <br />U <br />PER SPECS <br />W <br />GARAGE,./ <br />' w <br />1 &GARAGE <br />- <br />DOOR <br />GFI <br />�------------------------------� <br />I I <br />I <br />I <br />IRRIGATION GFI 1 <br />• <br />i ' <br />@ 44" A.F.F. <br />I <br />I � <br />I <br />I <br />I <br />I � <br />I <br />I <br />I / <br />I <br />------------------------------ <br />r <br />------------CaACHT11GFITS ----------- <br />OR PREWIRE AS <br />\ \ PER SPECS <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />W <br />�O <br />Q <br />BUJ <br />i OJ an <br />� I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER <br />GFI @ <br />44" A.F.F. <br />ill 3" VTR 1.5" VTR <br />I � �I►I <br />I� <br />I I <br />I I <br />I I <br />K� I I <br />—111 3" VTR <br />I � I 1� <br />I I <br />j I (�/ � I <br />I I I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN_ <br />M1 .fl <br />♦� O W <br />Z ar <br />_ cc C.i <br />N <br />r C W O. <br />0 N L <br />to <br />BC <br />Q-NED <br />ai ai <br />i E �" c <br />d Ewa <br />�� co <br />d <br />C <br />tD C <br />a � <br />0 <br />M <br />0 <br />N <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />11- W a E 8 N <br />Q M <br />0 2 LL J <br />D7 � LL <br />to � 0 t` wa <br />to 0`1 w <br />oO. <br />a@NLc�oL <br />103 Z <br />o <br />oQ <br />O 0wa� <br />mr- mJ_ <br />O°' ¢ znF <br />mCj <br />W°� <br />Ln M Z <br />ILW <br />C.) CD F=- <br />aN <br />O U ❑❑❑ <br />W <br />C'4 <br />n- <br />V I <br />N z '9 <br />Cn <br />W CM <br />Q A <br />U <br />0 <br />W S <br />Ly N <br />�V) <br />N = D <br />f6 <br />U ry�tp <br />r-- — E <br />®� W J <br />t $ <br />j <br />S <br />U <br />0 <br /><Z <br />w <br />M <br />� �4 <br />g <br />LJL <br />d. Q <br />U <br />wo <br />� O <br />W '+ <br />z <br />ZN <br />Z Z a <br />❑a <br />F— 1D <br />pc <br />E1° <br />so <br />r <br />Uu <br />¢ <br />Z <br />` <br />�o <br />ww <br />in <br />`z <br />0¢ <br />U <br />mo <br />°� <br />Zr <br />Z <br />m J <br />Nm <br />a� <br />¢w <br />�ZO <br />0 <br />U <br />W <br />p20xw <br />3 <br />� <br />I_ <br />I5 <br />Lln <br />0 <br />m <br />� <br />N <br />Lo <br />T <br />L , <br />cc <br />a. <br />m <br />= <br />�N� <br />Y �/ <br />...00 <br />0 _ <br />N <br />0) <br />CO <br />O <br />LC� <br />r <br />N <br />N <br />r <br />ai <br />T <br />CM M <br />0M <br />N ;� ) <br />Z <br />Z <br />E N a <br />m <br />a <br />E .. v` ui <br />U Q p <br />JOB <br />NO: 23-06124 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.