Laserfiche WebLink
L ! I 1 1111' 11 1 <br />t _. <br />CU <br />1co LL <br />Ln <br />ru <br />CS <br />U <br />ICU 00 <br />0*4 <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. <br />Q CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY I CACT"1F:DQ <br />� <br />� <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 (1) PLY <br />1450 (2) PLY <br />7 - 10d x 1 1/2" <br />6-16d x 3 112" <br />HTA20 <br />1870 <br />1730 <br />A 2) <br />( <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />_ <br />10 -10d x 1 1/2" <br />14- 16d x 3 1/2" <br />(2)HTA20 <br />2430 <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" � <br />HTA16 <br />1870 <br />1730 <br />C <br />H2.5A <br />700 <br />615 <br />10 - 8d x 2 1/2" <br />RT7A <br />630 <br />510 <br />D <br />H3 <br />400 <br />365 <br />8 - 8d x 2 1/2" <br />RT3 <br />345 <br />305 <br />E <br />META20 <br />1450 <br />8 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1495 <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />G <br />H 10A <br />1040 <br />1015 <br />18 - 10d x 1 1 /2" <br />RT 16A <br />1025 <br />900 <br />H <br />FGTR <br />4725 <br />3400 <br />wl (18) 1 x DS WOOD SCREWS AND <br />(2)1/2" x 5" TITEN HD ANCHOR BOLTS <br />RFUS <br />7100 <br />J <br />HTT5 <br />4350 <br />3740 <br />5l8"ANCH, / (26) 10dx1-1/2" <br />HTT45 <br />5795 <br />K <br />HD313 * <br />3130 <br />3050 <br />5/8" ANCH./ (2) 5/8" STUD BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />L <br />VGT R/L <br />2225 <br />1600 <br />(16)114"x3"SDS WOOD SCREWS & <br />HDU4-SDS2.5 wl (10) 114"x2-112" SDS <br />WOOD SCREWS & (1) 518" ATR <br />___ <br />___ <br />M <br />VGT - F <br />4940 <br />3555 <br />----- <br />-- <br />--- <br />- <br />--- <br />N <br />LUS26 <br />1165/1150 ** <br />865/785 ** <br />8 - 10d x 3" <br />JUS26 <br />105011080" <br />840/950** <br />P <br />HUS26 <br />1320/3280 ** <br />1150/2780 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2045/3400 <br />1640/2990** <br />Q <br />HUS28 <br />1760/4095 *` <br />1480/3520 ** <br />_ <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />R <br />MTS12 <br />990 <br />850 <br />14 - 10d x 1 1/2" <br />MTW12 <br />810 <br />S <br />VGT - M* <br />4940 <br />3555 <br />16) 114"x" SDS OD SCREWS & <br />1) 5/8"ATR EPDXIED wl SIMPSON <br />EN <br />_ <br />_965 <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />"— <br />4730-M 5010-F <br />x - <br />& (8) 3/8"x5"TITEN HD (2 PLY) or <br />5 16d SINKERS FRAME <br />U <br />MGT -M' <br />3965 <br />3330 <br />(22)10d x 3" w/ (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" EPDXY <br />MUGT15 <br />4240 <br />3730 <br />W <br />MGT -F^ <br />(32)10d x 3-1/4"SINKERS 6 (14) TITEN TURBO <br />LOW ROOF / FLOOR FRAMING PLAN - <br />STANDARD (STD) <br />SCALE: %4"=1'-0" <br />CCA 01/25/2016 <br />9-10dx1112" <br />9 -10d x 1 1/2" <br />9 - 10d x 1 1/2" <br />10 - 8d x 1 1/2" <br />8 - 8d x 1 1/2" _ <br />9-10dx1112" <br />11-10dx11/2" <br />9- 1 Od x 1 1/2% 8-1 Od <br />07WS3 WOOD SCREWS & <br />(4) 3/4" x 6" WEDGE -BOLTS <br />5/8" ANCH. /(26) 10d x2-112 <br />5/8" ANCH./ (2) 5/8" STUD BOL <br />(8)-10dx3" <br />(20)16d x 3-1/2" <br />30d -16d x 3-1/2" <br />14-10d x 1-112" <br />(28)10d x 3" (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C EPDXY <br />(32)10d x 3" (0) 14"x " EWALT <br />V <br />(2) LGT2 <br />4060-M 4080-F <br />3500-M 3510-F <br />(2 PLY) or (60)10d x 3.114" SINKERS @ FRAME <br />LUGT2 <br />3310-M 4040-F <br />2920-M 3560-F <br />SCREW -BOLT or (64)10d x 3" @ FRAME <br />"X" <br />HTS 20 <br />1415 <br />1215 <br />16 -10d x 1 1/2" <br />HTW20 <br />1355 <br />1140 <br />24-1Od x 1 1/2" <br />SP1 <br />555 <br />535 <br />10 - 10d x 3" <br />SPT22 <br />735 <br />8 - 10d x 3" <br />SP2 <br />1010 <br />605 <br />12 - 10d x 3" <br />SPT24 <br />1090 <br />12 - 10d x 3" <br />HCP2 <br />590 <br />510 <br />12-1 Od x 1 1/2" <br />HHCP2 <br />680 <br />595 <br />(20)10d x 1-112" <br />` MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. <br />REVISED03-14-22 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />(A) <br />121 <br />OR 2 PLY <br />;ARRIER <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT (B <br />SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE <br />TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). INTERSECTING POINT <br />TO BE FASTENED w/ (2) - 16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD (+) <br />OF (B) TRUSS TO TOP CHORD (A) CARRIER TRUSS 2x CONT. SCAB SO. PINE w/ THE SAME SPECIFIED <br />COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER <br />(LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING <br />TRUSSES. R1 Vi <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS INTERSECTIONS. 1 O---(A) <br />SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING <br />SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />OR <br />CONT LEDG�R� <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RS H CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) <br />WIND AREA (+) VALUE DENOTES PRESSURE HIP ROOF >20 TO 45 DEG. <br />(SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=4ft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />HIP -35.94 -49.57 -49.57 -49.57 <br />10 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: %6" EXP. 1 (2Y,6) or 1Y32" EXP. 1 (3�6) <br />TILE: t%2' EXP. 1 (3�6) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 3/8" x 0.113") NAILS t <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1Y2", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2Y2" x 0.131 ") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />[4:12]-[12:12] <br />e•Nla <br />C <br />N <br />P+" <br />C <br />il— o <br />O a w <br />P <br />.L-. <br />c cewr.1�' <br />-�Im x <br />to � iV L <br />N O <br />cI ov N Y <br />d <br />a _c of <br />c <br />C_ � ca <br />RJ d 61 � <br />� V d <br />� G C <br />e N a s, <br />RJ E <br />M <br />N <br />0 <br />N <br />N <br />N <br />rn <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />hW- o E <br />Q p N Q �+ <br />5? N <br />N <br />� C <br />J <br />+� <br />0 00 � <br />M LL LL <br />7 � <br />N cnr-Z _- <br />u- w <br />Q �RNiov <br />13 <br />