Laserfiche WebLink
I..1L I I 1 1. _L 1 II ''_ _I _L . I I -1 _. I 1 II ' L- I I I I f. I I I _ I I I 1 'I I I _ - I I I I I- I' _I I� I I I I I I I I I II I_ <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FqF <br />WEATHERPROOF DUPLEX OUTLET <br />PET-W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />'4 �FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />;Qr EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />k<USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />Ua ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />3" VTR <br />JIB <br />I I <br />I I <br />I I <br />I I <br />OPT. <br />`I <br />I I LAV LAY <br />HANSON <br />I I BOX I <br />I I 3„ <br />I I W/C <br />LAV 1� SHOWER <br />3„ <br />TUB/ <br />W/C SHOWER <br />STUDOR <br />VENTI , DBL SINK <br />TI W/ DISP. <br />LAV I W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Riser Diagram <br />4 UNIT BUILDING <br />(2) 1532 UNITS & (2) 1624 UNITS <br />3" <br />800 AMP <br />0 <br />TERMINAL BOX <br />O <br />TENANT PANEL w/ 150 <br />150 AMP <br />150 AMP <br />AMP INSIDE MAIN <br />0 <br />O <br />150 AMP <br />150 AMP <br />0AM <br />1P <br />150 AMP <br />GROUND <br />1/0 CU. TO BUILDING STEEL <br />C.O. <br />E--- 2" PVC CONDUIT WITH 2 #2/0 AL - 1 #1/-0 AL-1 #1 AL <br />TO POWER CO. 6 REQUIRED PER BUILDING <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17 LOCAL CODES AND THE LOCAL POWER CO. <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT �\�10,� <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT i GFI <br />iM <br />QDGFI <br />r jG <br />o <br />1 I� <br />DINING �� I <br />I <br />KITCHEN 1 <br />GFI — <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />/,>ROUGH -IN\ <br />FOR OPT. <br />FAN/LIGHT 1 <br />I <br />I <br />1 / <br />FOYER <br />�i <br />/ r <br />I I <br />I <br />I DB <br />EN J RY O— <br />LIGJHTAS �O GFI& <br />PER SPECS <br />DB&GFI TO — <br />BE ALIGNED <br />VERTICALLY <br />I <br />4— <br />I <br />I�I <br />I <br />I <br />I <br />C.M <br />j • 11I1�17� <br />i <br />GFI <br />@ 44" <br />` \ <br />\ <br />LW.H. <br />A.F.F. <br />' <br />\ 0 <br />I <br />\ <br />1 <br />I <br />GARAGE <br />I <br />\ <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />--------------- <br />I <br />I � <br />b <br />I <br />I <br />Z <br />f= a <br />I <br />I <br />�a <br />I <br />I <br />iW� <br />W <br />I <br />I <br />Dw <br />I <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE: Y"=V-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />NOTE: <br />-INSTALL 2" CONDUIT TO METER CAN <br />-INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />O. BATH <br />BATH 2 <br />r.7 <br />WIC <br />I <br />OWNER'S <br />BEDROOM <br />/,,^ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />F` <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />— — — — — — — — — , <br />I <br />I <br />/P ! l <br />\ I I <br />V/ -WIC I <br />�\ LOFT <br />C.M \ <br />1 <br />/,>ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />\\BEDROOM 2 <br />2ND ELECTRICAL -UNIT-A 1532 <br />SCALE: Y4"=V-0" <br />M <br />c� <br />0 <br />cV <br />o <br />d' <br />0 <br />u a <br />N <br />cl- <br />y 10 O <br />to -0 N t <br />Q N Y <br />a� <br />d <br />o.s d <br />T E L C <br />M V r G <br />a N <br />u a� <br />m c rJ <br />c � <br />� o <br />G <br />CN <br />O <br />N <br />r <br />/ <br />ti <br />. - i _I <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />to <br />h <br />Q <br />o tE p S <br />O N '• N V <br />N <br />Lo <br />O � <br />07 <br />rntiti'_0 W w <br />- IQ <br />LL LL d Y dry" <br />! <br />0 <br />Z <br />o o <br />r m _ <br />o W O <br />W <br />Q <br />0 d Co <br />(1)°'6 �Gw <br />Z <br />ILW <br />M Z U V H <br />0 <br />N <br />b (3 ❑O❑ <br />Z <br />W <br />N M <br />imam <br />� <br />Q <br />N <br />G <br />U <br />o <br />i—J <br />(a <br />cn <br />w <br />U <br />L <br />f O <br />Oi <br />o0N <br />0 <br />J <br />p <br />oW <br />nN <br />E U <br />m <br />n <br />�u <br />0 <br />E <br />a; <br />Z <br />CO CU <br />4" <br />�o <br />w <br />�w <br />@ <br />z <br />o. <br />-25 <br />S <br />LL� <br />Z <br />az <br />W <br />T y <br />O <br />N <br />m <br />Will <br />Cn <br />-� <br />< <br />a <br />o r' <br />m <br />M <br />M <br />0 <br />tV <br />C,fl <br />fy <br />r <br />CO L 00 <br />O <br />CM <br />T <br />00 <br />r <br />L0 <br />Cr <br />' <br />U <br />O <br />m <br />O00 <br />r <br />� <br />T_ <br />04 <br />F— <br />s] <br />04 <br />Ln <br />.Q <br />O <br />LO <br />O <br />5 <br />Q O <br />(V <br />Lo <br />d' <br />CN <br />2 T <br />0) <br />o <br />m <br />3 O <br />�; <br />z <br />z <br />c <br />E <br />E <br />m <br />a <br />U <br />d <br />Q p <br />JOB <br />NO: 23-12150-12153 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />11.1 <br />