Laserfiche WebLink
3 <br />T3 <br />Q <br />00 <br />00 <br />CV <br />to <br />LO <br />U) <br />C, <br />rn <br />S <br />J <br />C) <br />O <br />1 <br />N <br />a <br />00 <br />N <br />1n <br />1rn <br />O <br />S <br />0 <br />J <br />C) <br />I <br />N <br />LO <br />rn <br />0 <br />0 <br />Q <br />rn <br />0 <br />Q <br />i <br />O <br />a <br />E <br />O <br />v <br />c <br />J <br />N <br />LZ <br />U <br />U <br />i <br />v <br />v <br />0 <br />a <br />U <br />a <br />d <br />iu <br />0 <br />i <br />0 <br />0 <br />LZ <br />rR <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR 1' <br />PANEL CENTER h `� <br />#14 to lights & outlets <br />NEMA 1 10 #12 to appliances and GFI I <br />150 AMP/ <br />200 AMP No #10 to WH <br />10 #6 to Range A ti/ I \ <br />#6 to HVAC <br />7 <br />200 amp <br />150 amp <br />UNDERGROUND [Dis <br />SERVICE BY POWER CO.----_ <br />INTERSYSTEM <br />BONDING O <br />TERMINATION PER 71 <br />NEC 17, 250.94 <br />150=2/0 <br />200=410 in 2" Conduit <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[C H <br />CHIMES (OPTIONAL) <br />�BP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />T� <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />_ <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM — <br />v Cr(Ir T IVIC I CR <br />LOCATION WITH <br />BUILDER <br />15'-0" <br />j1 VTR <br />I �^ <br />I AV I <br />I I <br />VTR 1 3" 1 311 <br />III 1,11 <br />N QI <br />-4 <br />< <br />211 I <br />Z" I <br />3'�wR 1 <br />I <br />I <br />ENTRY <br />9 <br />NK rl� <br />l:� SiNT <br />KiTG TO �E <br />W, Po <br />3". <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />MAIN FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />-.J <br />J <br />0 <br />G <br />O <br />N -d <br />a> -o <br />O <br />G <br />@`,N <br />rp yc. <br />to <br />c0 N <br />P p fa <br />N 1 <br />r_ <br />7 0 Q <br />3 Co -Q'3 <br />t0 J N <br />G+ <br />N ra <br />`v- <br />eo a <br />w <br />N <br />0 <br />CV <br />rn <br />CV <br />co <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />M <br />Jo FW- <br />a <br />' V <br />o E <br />00 N 8 <br />d <br />Co <br />N <br />.'T C <br />> u7 W N <br />^O <br />e <br />tits <br />N 2 <br />co v J u <br />MLL 5 5 <br />w w <br />w a <br />a, <br />I�il Z <br />M N <br />}w}. <br />W <br />W <br />2 <br />ILQ <br />_ <br />N (D <br />02r- <br />rn rn 0 <br />�, <br />O <br />0 <br />m <br />N <br />(N <br />d <br />J <br />(� <br />6 <br />UO <br />U' f7 N <br />N C, <br />0 <br />� 6 a <br />J <br />Q. � <br />N <br />N <br />'n <br />'�'C• <br />4-1 <br />t� w �c <br />Q <br />U <br />O <br />o <br />,, <br />N c J <br />F E <br />L <br />"a0} <br />• <br />U 93 <br />< Y <br />N O� <br />ti <br />Z)W <br />co <br />M <br />¢ <br />5 <br />q <br />LL <br />E <br />E <br />wz <br />aR <br />oa <br />>o <br />Zo <br />O <br />N <br />a <br />R <br />Z <br />� ry <br />r � <br />� J <br />zq <br />�r <br />�n <br />- <br />i? -0 <br />m� <br />¢ . <br />w <br />s rn <br />W <br />T <br />a <br />� <br />O <br />nE <br />`< <br />D <br />o F <br />CID°s <br />�Iw <br />�aT. <br />�C:) <br />2 <br />> U')J <br />LOrn <br />0 <br />Q <br />CL <br />L, <br />F-- <br />Qi <br />C:)co <br />C) <br />Y <br />�--- <br />rCf <br />V J o <br />`o <br />N <br />m <br />+-� m <br />LO <br />T <br />Q <br />0 <br />s <br />i <br />'D N <br />L0 <br />00 <br />00 <br />-0 <br />QC1*4 <br />am N <br />T <br />ai <br />TT <br />V J <br />00 (V <br />iri 0 <br />o <br />Z <br />rEu <br />Z <br />E O <br />to <br />a <br />E <br />_j <br />_0 w <br />a o <br />c <br />c <br />JOB <br />NO: <br />22-09414 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />"-.T �--- <br />