Laserfiche WebLink
I tI fElIII - t 11' I I 1 19 1! I I — -- �— <br />3 <br />v <br />m <br />W) <br />I <br />to <br />it, <br />0 <br />N <br />0 <br />J <br />is <br />0 <br />I <br />N <br />i <br />m <br />N <br />M <br />to <br />!n <br />O <br />O <br />4 <br />0 <br />I <br />M <br />to <br />O <br />tyT <br />3 <br />H <br />h7 <br />N <br />N <br />E <br />0 <br />E <br />x <br />J <br />d <br />,o <br />0 <br />0 <br />tv <br />Ef <br />0 <br />0 <br />0 <br />a <br />M <br />CN <br />t <br />to <br />S <br />0 <br />�m <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI LIL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />. <br />� 4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />I{6]P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />I [D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />i✓ J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />M <br />C <br />20( <br />15C <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />Typical 150-200 Amp <br />NOTE: ELECTRICAL MATERIAL AND <br />PROVISIONS OF THE NFPA 70-2017, <br />CODES AND THE LOCAL POWER/UT <br />150A/200A INDOOR <br />PANEL CENTER <br />1111 014 to lights & outlets <br />NEMA 1 10 a12 to appliances and GFl <br />150 AMP/ <br />200 AMP 10 a10 to WH <br />a8 to Range01 <br />f <br />as to HVAC <br />FIRST FLOOR ELECTRICAL PLAN — ELEV-131 <br />SCALE: %4"=1'-0" <br />e+ri <br />N <br />C= <br />CV <br />� <br />Ego <br />C <br />U CV <br />C 1L a <br />N R CD r <br />N W O eC <br />Q N <br />W <br />E c <br />CD J <br />ao W as .a <br />F <br />N as <br />E <br />M <br />N <br />O <br />N <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />Q <br />E p 9 N <br />UV N_ 0-0d <br />0 <br />- C �i # <br />J <br />(nm� # <br />N <br />J <br />N(14io a a <br />a <br />J aZ <br />V�� <br />Z <br />13 <br />mc" <br />�X o��9r <br />Q <br />D W N (D m JCo <br />W <br />w <br />Z <br />IL <br />00 d o <br />M Z U H <br />Z <br />N (n <br />O U ❑❑❑ <br />W <br />M <br />N M <br />00 <br />M <br />N <br />` <br />0 <br />t� <br />U a <br />U <br />O <br />�Ln <br />� <br />pom <br />I.A.1 p <br />r:" <br />) <br />ll J <br />E <br />t <br />l L <br />sm <br />ti <br />0 <br />(a <br />ch <br />M <br />J <br />t1 <br />� <br />Nix <br />z u <br />rc <br />u <br />a <br />E <br />E v <br />t� <br />6 E <br />Q <br />�n <br />i <br />Z <br />o <br />U.)C: <br />�= <br />10 o- <br />Z7D� <br />m, <br />K� <br />W <br />C' <br />m <br />r <br />o <br />T <br />Z <br />J <br />LO <br />^ <br />LO <br />OI <br />C <br />Q <br />c� <br />V O <br />ca <br />r <br />C)C <br />J <br />T_ <br />Ym <br />T-- <br />Cl) ca <br />co <br />N <br />LO <br />r <br />Q <br />�O <br />I <br />cv N <br />O <br />M <br />-0 <br />� N <br />M <br />Q <br />1 <br />�" <br />ui <br />E <br />T <br />c <br />CD L0 <br />coo <br />z <br />Z <br />E r <br />E <br />c <br />m <br />n <br />U � <br />Q O <br />J <br />JOB <br />NO: <br />23-06144 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />