Laserfiche WebLink
PROJECT INFORMATION <br />ONVNER <br />SF ZEPHYR COMMONS OUTPARCELS LP <br />400 CLEMANTIS STREET; SUITE 200 <br />WEST PALM BEACH, FLORIDA 33401 <br />TEL: 678-977-3362 <br />CONTACT: JEFFREY W. PRESTON <br />ARCHITECTURAL <br />STINARD ARCHITECTURE, INC. <br />217 SOUTH ERWIN STREET <br />CARTERSVILLE, GA 30120 <br />TEL: 770-425-7400 FAX: 770-425-7444 <br />ARCHITECT OF RECORD: SCOTT STINARD <br />FL LICENSE NO. 16999 <br />STRUCTURAL <br />BENNETT & PLESS <br />3395 NORTHEAST EXPRESSWAY, SUITE 110 <br />ATLANTA, GA 30341 <br />TEL: 678-990-8700 FAX: 678-990-8701 <br />ENGINEER OF RECORD: PAUL GRUPE <br />FL LICENSE NO.: 32427 <br />PLUMBING., MECHANICAL & ELECTRICAL <br />PROFICIENT ENGINEERING, INC. <br />6991 PEACHTREE INDUSTRIAL BLVD BLDG 700 <br />PEACHTREE CORNERS, GA 30092 <br />OFFICE: 404-330-9798 CELL: 404-394-1147 <br />ELECTRICAL ENGINEER OF RECORD: BRIAN ARMENTA <br />FL LICENSE NO. 67193 <br />MECHANICAL ENGINEER OF RECORD: JOHN P. KENNEY <br />FL LICENSE NO. 70199 <br />PLUMBING ENGINEER OF RECORD: JOHN P. KENNEY <br />FL LICENSE NO. 70199 <br />BUILDING CODE SUMMARY <br />THE BUILDING DESCRIBED IN THESE PLANS SHALL BE CONSTRUCTED IN COMPLIANCE WITH THE FOLLOWING CODES: <br />2017 - 6TH EDITION FLORIDA BUILDING CODE - BUILDING <br />2017 - 6TH EDITION FLORIDA BUILDING CODE - PLUMBING <br />2017 - 6TH EDITION FLORIDA BUILDING CODE - FUEL GAS <br />2017 - 6TH EDITION FLORIDA BUILDING CODE - MECHANICAL <br />2017 - 6TH EDITION FLORIDA BUILDING CODE - ACCESSIBILITY <br />2017 - 6TH EDITION FLORIDA BUILDING CODE - ENERGY CONSERVATION <br />2017 - 6TH EDITION FLORIDA FIRE PREVENTION CODE <br />2015 EDITION NFPA I WITH FLORIDA AMENDMENTS <br />2015 EDITION NFPA 101 WITH FLORIDA AMENDMENTS <br />20 10 ADA STANDARDS FOR ACCESSIBLE DESIGN <br />2014 NATIONAL ELECTRICAL CODE/NFPA 70 <br />OCCUPANCY CLASSIFICATION: <br />NON -SEPARATED MIXED OCCUPANCY (508.3): <br />GROUP B BUSINESS (3 04. 1) <br />GROUP S-1, MODERATE HAZARD STORAGE <br />(311.2) <br />CONSTRUCTION TYPE: <br />T 601 <br />BUILDING HEIGHT: <br />PROPOSED <br />ALLOWABLE: TABULAR (T503) <br />SPRINKLER INCR (504.2) <br />TOTAL <br />BUILDING AREA: <br />PROPOSED: I ST FLR - STORAGE <br />2ND FLR - STORAGE <br />2ND FLR - BUSINESS <br />TOTAL <br />ALLOWABLE - SINGLE OCCUPANCY MULTI -STORY (506.2.3): <br />TABULAR (T 506.2, S- 1, 11 B, SM/NS) <br />FRONTAGE (506.3.3, NS): <br />(F/P)-.25)x(W/30') = If, (if x At) <br />ALLOWABLE AREA/FLR <br />ACTUAL STORIES (4 MAX) <br />TOTAL ALLOWABLE BUILDING AREA <br />FIRE PROTECTION SYSTEMS: <br />AUTOMATIC SPRINKLER SYSTEM (903.2.9) <br />STAND PIPE SYSTEM (905.3) <br />PORTABLE FIRE EXTINGUISHERS (906.1) <br />FIRE ALARM AND DETECTION (907.2) <br />[NFPA 10142.3.4.1.31 <br />FIRE RESISTIVE CONSTRUCTION: <br />EXTERIOR WALLS (T602) <br />EXTERIOR OPENINGS (705.8.1 EX 2) <br />FIRE WALL <br />FIRE BARRIER - SHAFT (707.3.1, 713.4, 1022.2) <br />CORRIDORS (T 10 18. 1) <br />OCCUPANT LOAD: <br />TABLE 1004.1.2 [NFPA 101 T7.3.1.2,42.1.71: <br />1 ST FLR WAREHOUSE@ 11500 GSF <br />2ND FLR WAREHOUSE @ 11500 GSF <br />2ND FLR_ BUSINESS @ 1/100 GSF <br />TOTAL <br />EGRESS CAPACITY: <br />CORRIDORS: <br />OCCUPANT LOAD x 0.2" (1005.3.2) [NFPA 10 1 T7.3.3. I ] <br />MIN WIDTH (T 10 18.2) [NFPA 10 17.3.4. 1 (1)] <br />DOORS: <br />OCCUPANT LOAD x 0.2" (1005.3.2) [NFPA 10 1 T7.3.3. I ] <br />MIN WIDTH (1008. 1. 1) [NFPA 10 1 7.2.1.2.3.21 <br />X" <br />BLDG A BLDG B BLDG C BLDG D BLDG E BLDG F <br />GROUP S- I GROUPS-] GROUP S- I GROUP S- I GROUPS-] GROUP S- I <br />GROUP - B <br />TYPE H B <br />20'-4" / 2 STORY <br />55'/ 2 STORY <br />20'/ 1 STORY <br />75'/ 3 STORY <br />26,174 SF <br />25,344 SF <br />830 SF <br />52,348 SF <br />52,500 SF <br />12,600 SF <br />65, 100 SF/FLR <br />2STORY <br />130,200 SF <br />TYPE H B TYPE 11 B <br />9'-9" / I STORY 9'-6" / I STORY <br />55'12 STORY 55'12 STORY <br />N/A N/A <br />55'12 STORY 55'12 STORY <br />5,100 SF 3,400 SF <br />TYPE Il B TYPE 11 B <br />10'-6" / I STORY 9'-9" / I STORY <br />55'12 STORY 55'/2STORY <br />N/A N/A <br />55'12 STORY 55'12 STORY <br />3,925 SF 6,600 SF <br />TYPE H B <br />10'-0" / I STORY <br />55'12 STORY <br />8,800 SF <br />NOTINCLUDED NOTINCLUDED NOTINCLUDED NOTINCLUDED NOT INCLUDED <br />NFPA 13 <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />PROVIDED <br />PROVIDED <br />PROVIDED <br />PROVIDED <br />PROVIDED <br />PROVIDED <br />SPRINKLER <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />NOT REQD <br />0 14R (>I 0') <br />NO LIMIT (0 HR) <br />N/A <br />1 HR <br />0 HR (SPRINK) <br />53 (26,174/500) <br />51 (25,344/500) <br />9 (830/100) <br />113 <br />I <br />ZEPI COMMONS <br />0 HR (>10') <br />0 HR (>10') <br />0 HR (>101) <br />0 HR (>10') <br />0 HR (>10') <br />NO LIMIT (0 HR) <br />NO LIMIT (0 HR) <br />NO LIMIT (0 HR) <br />NO LIMIT (0 HR) <br />NO LIMIT (0 HR) <br />3HR <br />3HR <br />3HR <br />3 14R <br />3HR <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />11 (5,1001500) 7 (3,400/500) 8 (3,925/500) 14 (6,600/500) 18 (8.800/500) <br />11" (53 x 0.2") 3" (11 x 0.2") 2" (7 x 0.2") 2" (8 x 0.2") 3" (14 x 0.2") 4" (18 x 0.2") <br />44" 36" (<50) 3611 (<50) 36" (<50) 3611 (<50) 36" (<50) <br />I I" (53x 0.2") 3" (1 Ix 0.2") 2" (7x 0.2") 2" (8 x 0.2") 3" (14x 0.2") 4"(18xO.2") <br />32" 321# 32" 3211 32ft 3211 <br />MIN NUMBER OF EXITS (T 1021.2(2)) [NFPA 10142.2.4.1(3)] <br />2 PER FLR <br />MAX TRAVEL DISTANCE (T 10 16.2) [NFPA 10 1 T42.2.61 <br />250'(SPRINK) <br />MAX COMMON PATH TRAVEL (T 1014.3) [NFPA 101 T42.2.51 <br />100'(SPRINK) <br />MAX DEAD END CORRIDOR (10 18.4) [NFPA 10 1 T42.2.51 <br />50'(SPRINK) <br />PLUMBING FIXTURES: <br />WATER CLOSETS (T 2902. 1): MALE FEMALE <br />BUSINESS @ (9/2)/25 = 0.18 0.18 <br />STORAGE @ (157/2)/100 = 0.79 0.79 <br />TOTAL 0.97 = 1 0.97 1 <br />LAVATORIES (T 2902. 1): <br />BUSINESS @ (9/2/40) = 0.11 0.11 <br />STORAGE @ (157/2/100) = 0.79 0.79 <br />TOTAL 0.90 = 1 0.90 1 <br />DRINKING FOUNTAINS: <br />BUSINESS @ (9/100) = 0.09 <br />STORAGE @ (157/1000) 0.16 <br />TOTAL 0.25 = I <br />SERVICE SINK: I <br />1 (<49, <75') <br />1 (<49, <75') <br />1 (<49, <75') <br />1 (<49, <75') <br />1 (<49,<75') <br />200' <br />200' <br />200' <br />200' <br />200' <br />100, (<30) <br />100'(<30) <br />1001 (<30) <br />100'(<30) <br />100'(<30) <br />20' <br />20' <br />20' <br />20' <br />20' <br />F <br />SET J <br />STOPAGE <br />3 8011 Pretty Pond Road <br />ephyrhills, F 33541 <br />GENERAL NOTES <br />I . GENERAL: NOTES AND DETAILS INDICATED ON DRAWINGS APPLY TO ALL SIMILAR CONDITIONS. <br />DO NOT SCALE DRAWINGS. LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER <br />SCALE DRAWINGS. IN CASE OF CONFLICTING REQUIREMENTS FOR QUANTITIES OR QUALITY <br />LEVELS, COMPLY WITH T14E MOST STRINGENT REQUIREMENT. <br />2. CONTRACT DOCUMENT AND FIELD CONDITION REVIEW: THE GENERAL CONTRACTOR SHALL <br />COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER AND THE FIELD CONDITIONS, AND <br />REPORT ANY INCONSISTENCIES, ERRORS, OR OMISSIONS TO THE ARCHITECT BEFORE BEGINNING <br />THE WORK. VERIFY DIMENSIONS AND FIELD CONDITIONS AND NOTIFY T14E ARCHITECT OF ANY <br />DISCREPANCIES BEFORE BEGINNING THE WORK. WHERE DETAILED INFORMATION IS LACKING, <br />REQUEST INSTRUCTIONS FROM THE ARCHITECT. <br />3. SPECIAL INSPECTIONS: THE OWNER IS RESPONSIBLE FOR PROVIDING AN INSPECTION AND <br />TESTING AGENCY APPROVED IN THE STATE WHERE THE PROJECT IS LOCATED TO PERFORM ALL <br />SPECIAL INSPECTIONS AND FURNISH ALL REPORTS FOR THIS PROJECT IN ACCORDANCE WITH <br />THE STATEMENT AND SCHEDULE OF SPECIAL INSPECTIONS - SEE STRUCTURAL FOR SPECIFIC <br />REQUIREMENTS. <br />4. LOW VOLTAGE SYSTEMS: DESIGN OF LOW VOLTAGE SYSTEMS INCLUDING SECURITY, DATA, <br />AND COMMUNICATIONS IS THE RESPONSIBILITY OF THE OWNER. THE GENERAL CONTRACTOR IS <br />RESPONS113LE FOR COORDINATING WITH THE OWNER'S REQUIREMENTS, AND PROVIDING <br />CONDUIT TO LOCATIONS MADE INACCESSIBLE BY CONSTRUCTION. <br />5. FIRE SPRINKLER SYSTEM - BLDG A: DESIGN OF FIRE SPRINKLER SYSTEM IS THE <br />RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE ENTIRE BUILDING IS TO BE FULLY <br />SPRINKLERED IN ACCORDANCE WITH NFPA 13, AND ALL FEDERAL, STATE AND LOCAL CODES. <br />SUBMIT SPRINKLER SYSTEM DRAWINGS PREPARED BY A CERTIFIED SPRINKLER CONTRACTOR TO <br />THE FIRE MARSHAL FOR APPROVAL, AND OBTAIN A SEPARATE PERMIT FOR THE FIRE SPRINKLER <br />SYSTEM. COORDINATE SPRINKLER SYSTEM WITH SURROUNDING CONSTRUCTION. <br />6. FIRE ALARM SYSTEM - BLDG A: DESIGN OF FIRE ALARM SYSTEM IS THE RESPONSIBILITY OF THE <br />GENERAL CONTRACTOR. PROVIDE A LIMITED FIRE ALARM SYSTEM FOR DUCT SMOKE <br />DETECTORS, AND SPRINKLER SYSTEM SUPERVISION IN ACCORDANCE WITH NFPA 72, AND ALL <br />FEDERAL, STATE AND LOCAL CODES. SUBMIT FIRE ALARM SYSTEM DRAWINGS PREPARED BY A <br />CERTIFIED CONTRACTOR TO THE FIRE MARSHAL FOR APPROVAL, AND OBTAIN A SEPARATE <br />PERMIT FOR THE FIRE ALARM SYSTEM. COORDINATE FIRE ALARM SYSTEM WITH SURROUNDING <br />CONSTRUCTION. <br />7. FIRE EXTINGUISHERS: PROVIDE FIRE EXTINGUISHERS IN ACCORDANCE WITH THE FIRE <br />MARSHAL'S REQUIREMENTS. PROVIDE MINIMUM SIZE OF 2A I OBC, AND MOUNT IN CABINET WITH <br />BOTTOM AT 27" ABOVE FINISH FLOOR. <br />8. BUILDING ADDRESS: POST ADDRESS ON EACH BUILDING IN ACCORDANCE)WITH THE FIRE <br />MARSHAL'S REQUIREMENTS. <br />9. KNOX BOX: PROVIDE KNOX BOX IN ACCORDANCE WITH THE FIRE MARSHAL'S REQUIREMENTS. <br />CONTACT FIRE MARSHAL FOR APPLICATION. <br />10. FIRE BARRIER IDENTIFICATION: PROVIDE PERMANENT SIGNS OR STENCILING ON ALL FIRE <br />AND/OR SMOKE RATED BARRIERS ABOVE ANY DECORATIVE CEILING AND/OR IN CONCEALED <br />SPACES. IDENTIFICATION TO BE IN 2" HIGH LETTERING, SPACED EVERY 12 FEET, AND READ "I <br />HOUR FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS", OR EQUIVALENT WORDING <br />ACCEPTABLE TO AUTHORITY HAVING JURISDICTION. <br />11. ACCESSIBLE STORAGE UNITS: PROVIDE ACCESSIBLE STORAGE UNITS IN ACCORDANCE WITH <br />2012 INTERNATIONAL BUILDING CODE SECTION 1108.3 AND ADA 2010 STANDARDS FOR <br />ACCESSIBLE DESIGN SECTION 225.3. <br />12. EXTERIOR SIGNAGE: DESIGN OF EXTERIOR SIGNAGE IS BY OTHERS. COMPLY WITH ALL LOCAL <br />CODES. SUBMIT SIGNAGE DRAWINGS TO THE AUTHORITY HAVING JURISDICTION FOR APPROVAL, <br />AND OBTAIN A SEPARATE PERMIT FOR SIGNAGE. COORDINATE SIGNAGE WITH SURROUNDING <br />CONSTRUCTION. <br />13. EMERGENCY RESPONDER RADIO COVERAGE: NOTIFY FIRE MARSHAL AT STAGE OF <br />CONSTRUCTION REQUIRED TO TEST EMERGENCY RESPONDER RADIO COVERAGE. <br />ABBREVIATIONS <br />@ <br />AT <br />ABV <br />ABOVE <br />ACM <br />ALUM COMPOSITE MATERIAL <br />ACOUST <br />ACOUSTICAL <br />AFF <br />ABOVE FINISH FLOOR <br />ALUM <br />ALUMINUM <br />ALT <br />ALTERNATE <br />AMV <br />ADHERED MASONRY VENEER <br />ANOD <br />ANODIZED <br />AP <br />ACCESS PANEL <br />ARCH <br />ARCHITECTURAL <br />AWB <br />AIR WATER BARRIER <br />BD <br />BOARD <br />BLDG <br />BUILDING <br />BM <br />BEAM <br />CABT <br />CABINET <br />BOT <br />BOTTOM <br />CEM <br />CEMENT <br />ci <br />CONTROL JOINT <br />CL <br />CENTERLINE, CLOSET <br />CLG <br />CEILING <br />CLR <br />CLEAR <br />CNTR <br />COUNTER <br />CMU <br />CONCRETE MASONRY UNIT <br />CO <br />CASED OPENING <br />COL <br />COLUMN <br />CONC <br />CONCRETE <br />CONT <br />CONTINUOUS <br />CPT <br />CARPET <br />CT <br />CERAMIC TILE <br />DBL <br />DOUBLE <br />DEMO <br />DEMOLITION <br />DF <br />DRINKING FOUNTAIN <br />DIA <br />DIAMETER <br />DIM <br />DIMENSION <br />DN <br />DOWN <br />DR <br />DOOR <br />DS <br />DOWNSPOUT <br />DWG <br />DRAWING <br />EA <br />EACH <br />EF <br />EXHAUSTFAN <br />EIFS <br />EXTERIOR INSULATION AND <br />FINISH SYSTEM <br />EJ <br />EXPANSION JOINT <br />ELEC <br />ELECTRICAL <br />ELEV,EL <br />ELEVATION <br />EPDM <br />ET14YLENE PROPYLENE <br />DIENE MONOMER <br />EQ <br />EQUAL <br />EQUIP <br />EQUIPMENT <br />EW <br />EACH WAY <br />EWC <br />ELECTRIC WATER COOLER <br />EXP <br />EXPANSION <br />EX <br />EXISTING <br />EXT <br />EXTERIOR <br />FC <br />FIBER CEMENT <br />FD <br />FLOOR DRAIN <br />FE <br />FIRE EXTINGUISHER <br />FEC <br />FIRE EXTINGUISHER CABINET <br />FF <br />FINISH FLOOR <br />FG <br />FIBERGLASS <br />FIN <br />FINISH <br />FLR <br />FLOOR <br />FOC <br />FACE OF CONCRETE <br />FOM <br />FACE OF MASONRY <br />FOS <br />FACE OF STEEL/STUD/SLAB <br />FRT <br />FIRE RETARDANT TREATED <br />FT <br />FEET <br />FVC <br />FIRE VALVE CABINET <br />GA <br />GAUGE <br />GAB <br />GRADED AGGREGATE BASE <br />GALV <br />GALVANIZED <br />GYP <br />GYPSUM <br />HI3 <br />HOSE BIBB <br />HC <br />HOLLOW CORE <br />HDWD <br />HARDWOOD <br />HDWR <br />HARDWARE <br />HGT <br />HEIGHT <br />lim <br />HOLLOW METAL <br />HOR <br />HORIZONTAL <br />HP <br />HIGH POINT <br />HR <br />HOUR <br />ID <br />INSIDE DIAMETER <br />IN <br />INCH <br />INT <br />INTERIOR <br />INSUL <br />INSULATION <br />JT <br />JOINT <br />LAM <br />LAMINATE <br />LAV <br />LAVATORY <br />LF <br />LINEAR FOOT <br />LGT <br />LIGHTING <br />LLH <br />LONG LEG HORIZONTAL <br />LLV <br />LONG LEG VERTICAL <br />LP <br />LOW POINT <br />MAINT <br />MAINTENANCE <br />MATL <br />MATERIAL <br />MAX <br />MAXIMUM <br />MBM <br />METAL BLDG MFR <br />MECH <br />MECHANICAL <br />MFR <br />MANUFACTURER <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MO <br />MASONRY OPENING <br />MTL <br />METAL <br />MTD <br />MOUNTED <br />MWP <br />METAL WALL PANEL <br />NIC <br />NOT IN CONTRACT <br />NTS <br />NOT TO SCALE <br />0C <br />ON CENTER <br />OD <br />OUTSIDE DIAMETER <br />OPP <br />OPPOSITE <br />PL <br />PLATE <br />PLAM <br />PLASTIC LAMINATE <br />PLYWD <br />PLYWOOD <br />PNL <br />PANEL <br />PNT <br />PAINT <br />PREFIN <br />PREFINISHED <br />PT <br />PRESERVATIVE TREATED <br />PVC <br />POLYVINYL CHLORIDE <br />QTY <br />QUANTITY <br />QT <br />QUARRY TILE <br />R <br />RADIUS, RISER <br />RD <br />ROOF DRAIN <br />REfNF <br />REINFORCEMENT <br />REQD <br />REQUIRED <br />REV <br />REVISION <br />RO <br />ROUGH OPENING <br />RM <br />ROOM <br />SAF <br />SELF -ADHERING FLASHING <br />SC <br />SOLID CORE <br />SCHED <br />SCHEDULED <br />SF <br />SQUAREFOOT <br />SFRM <br />SPRAYED FIRE -RESISTIVE <br />MATERIAL <br />Sim <br />SIMILAR <br />S/S <br />STAINLESS STEEL <br />STD <br />STANDARD <br />STL <br />STEEL <br />STN <br />STAIN <br />STRUCT <br />STRUCTURAL <br />SUSP <br />SUSPENDED <br />sv <br />SHEET VINYL <br />T <br />TREAD <br />T&G <br />TONGUE & GROOVE <br />TAFS <br />TEXTURED ACRYLIC FINISH <br />SYSTEM <br />TOM <br />TOP OF MASONRY <br />TOS <br />TOP OF STEEL <br />TYP <br />TYPICAL <br />UON <br />UNLESS OTHERWISE NOTED <br />VCT <br />VINYL COMPOSITION TILE <br />VERT <br />VERTICAL <br />VTR <br />VENT THROUGH ROOF <br />Vwc <br />VINYL WALL COVERING <br />W/ <br />WITH <br />WC <br />WATER CLOSET <br />WI) <br />WOOD <br />W/o <br />WITHOUT <br />vrP <br />WATERPROOFING / WORKING <br />POINT <br />WRB <br />WATER RESISTIVE BARRIER <br />WWF <br />WELDED WIRE FABRIC <br />XPS <br />EXTRUDED POLYSTYRENE <br />YD <br />YARD <br />DRAWING INDEX <br />ARCHITECTURAL <br />AO. I COVER SHEET <br />AO.2 UL DESIGN, COMCRECK, UNIT MIX, OUTLINE <br />SPECIFICATIONS <br />AO.3 OUTLINE SPECIFICATIONS <br />AO.4 OUTLINE SPECIFICATIONS <br />AO.5 LIFE SAFETY PLANS <br />A 1.0 ARCHITECTURAL SITE PLAN <br />ALI FIRST FLOOR PLAN - BLDG A <br />AL2 SECOND FLOOR PLAN - BLDG A <br />AL3 ROOF PLAN - BLDG A <br />AL4 ELEVATIONS - BLDG A <br />AL5 FLOOR/ROOF PLANS AND ELEVATIONS - BLDG B <br />AL6 FLOOR/ROOF PLANS AND ELEVATIONS - BLDG C <br />AL7 FLOOR/ROOF PLANS AND ELEVATIONS - BLDG D <br />AL8 FLOOR/ROOF PLANS AND ELEVATIONS - BLDG E <br />AL9 FLOOR/ROOF PLANS AND ELEVATIONS - BLDG F <br />(_4�33� ONS, DETAILS <br />I <br />I <br />A A �WALL �SE T�IONSS �AND DEA �S <br />A5.2 WALL SECTIONS AND DETAILS <br />WA <br />LL SECTION <br />SAND <br />DETAILS <br />I A 12 IMMM5 <br />- <br />A5.4 WALL SECTIONS AND DETAILS <br />A5.5 WALL SECTIONS AND DETAILS <br />ZZA <br />A7.1 SCHEDULES AND DETAILS <br />STRUCTURAL <br />SOA GENERAL NOTES <br />SO.2 SCHEDULES, COMPONENT AND CLADDING PRESSURES <br />SLI FIRST FLOOR FOUNDATION PLAN - BLDG A <br />SI.2 SECOND FLOOR FRAMING PLAN - BLDG A <br />SI.3 MAIN ROOF FRAMING PLAN - BLDG A <br />SL3A HIGH ROOF FRAMING PLAN - BLDG A <br />SIA FOUNDATION & ROOF FRAMING PLAN - BLDG B & C <br />SI.5 FOUNDATION & ROOF FRAMING PLAN - BLDG D <br />SI.6 FOUNDATION & ROOF FRAMING PLAN - BLDG E & F <br />S2.1 SECTIONS AND DETAILS <br />S2.2 SECTIONS AND DETAILS <br />S2.3 FOUNDATION ELEVATIONS <br />S3.1 SECTIONS AND DETAILS <br />S4.1 SECTIONS AND DETAILS <br />S4.2 SECTIONS AND DETAILS <br />S5.1 DETAILS & ELEVATIONS <br />GRAPHIC SYMBOLS <br />Y^l k1t, A SECTION <br />ELEVATION <br /><4 2 INTERIOR <br />3 > ELEVATION <br />DETAIL <br />MATERIALS LEGEND <br />ELECTRICAL <br />EO. I NOTES, LEGEND AND SPECIFICATIONS <br />EO.2 SCHEDULE, DIAGRAMS AND DETAILS <br />EO.3 SCHEDULES <br />ELI FIRST FLOOR PLAN - BLDG A <br />EL2 SECOND FLOOR PLAN - BLDG A <br />EL3 FLOOR PLAN - BLDG B, C, D <br />EIA FLOOR PLAN - BLDG E & F <br />E2.1 ENLARGEDPLANS <br />E3.1 LIGHTING CERTIFICATES AND INSPECTIONS <br />MECHANICAL <br />MOA SPECIFICATIONS, LEGEND AND ABBREVIATIONS <br />MO.2 DETAILS <br />MO.3 SCHEDULES <br />MO.4 COMPLIANCE CERTIFICATES & INSPECTIONS <br />Mi.] FIRST FLOOR PLAN - BLDG A <br />ML2 SECOND FLOOR PLAN - BLDG A <br />M2.1 ENLARGED PLAN - BLDG A <br />PLUMBING <br />POA SPECIFICATIONS, LEGEND AND SCHEDULES <br />PO.2 DETAILS <br />PLI FIRST FLOOR PLAN - BLDG A <br />PL2 SECOND FLOOR PLAN - BLDG A, ENLARGED PLANS <br />01011 <br />ELEVATION MARK <br />F=[N <br />Root_l <br />ROOM NAME <br />Eol <br />NUMBER <br />DOOR MARK <br />WINDOW MARK <br />PARTITION TYPE <br />01 <br />d <br />GYPSUM BOARD <br />STEEL <br />BATT/LOOSE <br />BRICK INSULATION <br />CONCRETE MASONRY RIGID INSULATION <br />UNIT <br />CONCRETE PLYWOOD <br />GRAVEL FINISH WOOD <br />I I�El 1 IE�9E]l Ea.� I iEi I 1 <br />I lEj I IEEI 1 12=1 1 E di <br />EARTH DIMENSIONAL WOOD <br />[Irp, N111--ilti-IN _11-411i glid, <br />VICINITY MAP <br />Z,1 <br />U-i uj <br />u D ry <br />U) LU <br />ui 0 uj u- L-ui <br />z 3: E3 L/) of I<- 0z < <br />-i >_ w ui 0 _j w <Z <br />_j Uj IL T U- CD ct < uuji <br />z < = 0 F- w 0'_ u <br />2 0 =n �-- Ln Fu- 0 0 0 <br />0 af Z <br />yj of 0 CL <br />mzzD0 3:to C�r�ljujco) <br />g�--<o <br />= Z75 cz z u) w Z' z �='r <br />Z U) 0 <br />< u u �� �� N - F- t 2 0 <br />z [-- 0 U) U) z uj P <br />(DO-0ffi::5uz[__zw M <br />z >- Lu Lu IL 0-- z zw=�--U)u <br />-::)) W w �; [-- wo w::) <br />�i �0_- L=Y) ou z < ffi 0 >- u �X- <br />0 m Z W <br />()�a_ucuc�uou__j M<Z <br />OOUJ[rujuj Zu__j0ucL0(D <br />ui cr a- F 0'- z < E < w Of UJ U z <br />IL uj - < < cr <br />= [L m <br />w w u Of Lu Uj < L6 <br />U UJ � F-- <br />- < i uu <br />= = Of w Ir 0'� z u= )!= c<r <br />I— < cr < IL Fn 0 0 F- E5 3: 0 <br />Q <br />c <br />ct ��4 <br />.0 <br />V <br />7� <br />ct <br />r= <br />>_1 <br />v <br />00.1 <br />ISSUE: FOR CONSTRUCTION <br />REVISIONS: <br />12-6-19 OWNERCOMMENTS <br />PROJECTNUMBER <br />201812 <br />DATE <br />4-3-19 <br />SHEET NUMBER <br />AOO I <br />