Laserfiche WebLink
� M <br />= 0 <br />GENERAL NOTES: <br />G <br />No. 32427 <br />1. PROVIDE CONSTRUCTION CONFORMING TO THE 2017 FLORIDA BUILDING CODE (SIXTH <br />EDITION). REFERENCE TO OTHER STANDARDS, SPECIFICATIONS, OR CODES MEANS THE <br />LATEST STANDARD OR CODE PUBLISHED AND ADOPTED. <br />2. THESE NOTES APPLY EXCEPT WHERE OTHERWISE INDICATED BY DRAWINGS OR <br />SPECIFICATIONS. <br />3. STRUCTURAL DRAWINGS INDICATE TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. <br />SUBMITTED SHOP DRAWINGS DETAIL ALL CONDITIONS IN ACCORDANCE WITH SPECIFIED <br />STANDARDS AND THE SPECIFIC REQUIREMENTS OF THIS PROJECT AS INDICATED ON THE <br />D RAVVI N G S. <br />4. COORDINATE THE STRUCTURAL CONTRACT DOCUMENTS WITH ARCHITECTURAL, <br />MECHANICAL, ELECTRICAL, PLUMBING, CIVIL, AND ALL OTHER CONSULTANTS. NOTIFY THE <br />ARCHITECT AND STRUCTURAL ENGINEER OF RECORD IN WRITING OF ANY CONFLICT AND/OR <br />OMISSION. <br />5. COORDINATE AND VERIFY FLOOR AND ROOF OPENING SIZES AND LOCATIONS SHOWN WITH <br />ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. FOR ADDITIONAL <br />OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS REFER TO THE ARCHITECTURAL <br />AND MECHANICAL DRAWINGS. OBTAIN WRITTEN APPROVAL OF ADDITIONAL OPENINGS <br />LARGER THAN 12"X 12" FROM THE STRUCTURAL ENGINEER OF RECORD. <br />6. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, ADEQUACY, AND SAFETY OF <br />ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, AND ALL OTHER MEANS, METHODS, <br />TECHNIQUES, SEQUENCES, AND PROCEDURES OF CONSTRUCTION. <br />7. COORDINATE THE BUILDING ORIENTATION WITH THE ARCHITECTURAL DRAWINGS. <br />8. COMPLETE SHOP DRAWINGS FOR CONSTRUCTION OF EACH BUILDING COMPONENT NOT <br />DESIGNED BY THE DESIGN TEAM OF RECORD AND NOT SPECIFIED ON THE PROJECT <br />CONSTRUCTION DOCUMENTS SHALL BE SEALED AND SIGNED BY A PROFESSIONAL <br />ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED AND SHALL BE MADE AVAILABLE <br />AT THE JOB SITE. <br />FOUNDATION: <br />1 THE DESIGN OF FOUNDATIONS, RETAINING WALLS, AND SLABS -ON -GRADE IS BASED ON THE <br />FOLLOWING CRITERIA ESTABLISHED IN THE GEOTECHNICAL REPORT BY UNIVERSAL <br />ENGINEERING SCIENCES, DATED OCTOBER 29,2018, REVISED NOVEMBER 8,2018, PROJECT <br />NUMBER 0830.1800145. <br />ALLOWABLE SOIL BEARING PRESSURE: 3000 PSF <br />COEFFICIENT OF SLIDING FRICTION: 0.40 <br />Ka (COEFFICIENT OF ACTIVE PRESSURE)- 0.33 <br />Kg (COEFFICIENT OF PASSIVE PRESSURE): 3.00 <br />Ko (COEFFICIENT OF AT REST PRESSURE): 0.50 <br />A GEOTECHNICAL REPORT WITH RECOMMENDED DESIGN CRITERIA MUST BE PROVIDED <br />PRIOR TO THE START OF CONSTRUCTION. <br />AFTER EXCAVATION, IF THE CONDITION OF THE SOILS DO NOT MEET THE RECOMMENDED <br />DESIGN CRITERIA STATED IN THE GEOTECHNICAL REPORT, NOTIFY THE ARCHITECT AND <br />STRUCTURAL ENGINEER OF RECORD SO THAT THE FOUNDATIONS MAY BE REDESIGNED IF <br />NECESSARY. <br />2. THE GEOTECHNICAL ENGINEER MUST VERIFY THE CONDITION AND/OR ADEQUACY OF ALL <br />SUB -GRADES, FILLS, AND BACKFILLS PRIOR TO THE PLACEMENT OF FOUNDATIONS, <br />FOOTINGS, SLABS, WALLS, ETC. <br />3. LOCATE TOP OF EXTERIOR FOOTING ELEVATIONS l'-6" BELOW FINISHED FLOOR, BUT NOT <br />LESS THAN l'-6" BELOW FINISHED GRADE, UNLESS NOTED OTHERWISE. <br />4. LOCATE TOP OF INTERIOR FOOTING ELEVATIONS 1'-0" BELOW FINISHED FLOOR, UNLESS <br />NOTED OTHERWISE. <br />5. BACK FILLING WALLS: <br />A. DEPOSIT BACKFILL AGAINST WALLS EVENLY AGAINST BOTH SIDES OF WALL UNTIL THE <br />LOWER FINAL GRADE IS REACHED. <br />B. DO NOT PLACE BACKFILL AGAINST WALLS DEPENDENT UPON TOP AND BOTTOM <br />CONCRETE SLABS FOR SUPPORT UNTIL THE CONCRETE SLABS HAVE ATTAINED 65% <br />OF THEIR DESIGN 28 DAY COMPRESSION STRENGTH. <br />C. SHORE AND BRACE WALLS SHOWN MONOLITHIC WITH A SLAB -ON -GRADE AT THE TOP <br />OF THE WALL DURING BACKFILLING OPERATIONS. <br />6. CONSTRUCT COLUMN FOOTINGS AND WALL FOOTINGS MONOLITHICALLY WITH TOPS OF <br />ADJACENT FOOTINGS AT THE SAME ELEVATION. <br />7. FILLS: <br />A. REMOVE ALL ORGANIC SOILS AND REPLACE WITH CLEAN STRUCTURAL FILL AT THE <br />DIRECTION OF THE GEOTECHNICAL ENGINEER. <br />B. PLACE FILL SOILS IN 6" MAXIMUM (LOOSE) LIFTS AT MOISTURE CONTENTS AS <br />DESCRIBED <br />IN THE GEOTECHNICAL REPORT. <br />C. COMPACT ALL FILL WITHIN 10'-0" OF THE BUILDING LIMIT TO 98% STANDARD PROCTOR. <br />D. TEST FIELD DENSITY AS DESCRIBED IN THE GEOTECHNICAL REPORT TO VERIFY <br />ADEQUATE COMPACTION AND DESIGN BEARING PRESSURE. <br />8. SIDES OF FOUNDATIONS MUST BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. <br />FOUNDATIONS PLACED AGAINST THE EARTH REQUIRE THE FOLLOWING PRECAUTIONS: <br />SLOPE SIDES OF EXCAVATIONS AS APPROVED BY THE GEOTECHNICAL ENGINEER AND <br />CLEAN UP SLOUGHING BEFORE AND DURING CONCRETE PLACEMENT. <br />9. WHERE FOOTING STEPS ARE NECESSARY, SLOPE NO STEEPER THAN ONE VERTICAL TO <br />TWO HORIZONTAL. <br />REINFORCED CONCRETE: <br />1 PROVIDE REINFORCED CONCRETE CONFORMING TO THE FOLLOWING STANDARDS: <br />ACI 301-10, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. <br />ACI 318-14, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. <br />ACI 302.1 R-04, GU I DE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION. <br />ACI 360R-10, DESIGN OF SLABS -ON -GROUND. <br />2. FULLY DOCUMENT AND SUBMIT FOR REVIEW THE PROPOSED MATERIALS AND MIX DESIGN <br />FOR ALL CONCRETE. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE REQUIRED <br />DESIGN STRENGTH. ALL CONCRETE TEST DATA MUST BE AVAILABLE AT THE JOB SITE. <br />3. DETAIL CONCRETE REINFORCEMENT ACCORDING TO ACI SP-66 DETAILING MANUAL. SUBMIT <br />SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS <br />FOR PLACING CONCRETE REINFORCING AND ACCESSORIES. DO NOT BEGIN FABRICATION <br />UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED BY THE STRUCTURAL ENGINEER <br />OF RECORD. UNLESS SPECIFICALLY APPROVED OTHERWISE, DETAIL ALL CONCRETE WALLS <br />AND BEAMS IN ELEVATION. <br />4. PROVIDE NORMAL WEIGHT CONCRETE WITH 4000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. <br />5. PROVIDE CONCRETE WITH: <br />A. 4% TO 6% ENTRAINED AIR BY VOLUME IN CONCRETE PERMANENTLY EXPOSED TO <br />WEATHER. <br />B. THE USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IS NOT <br />PERMITTED. <br />C. PLACE CONCRETE AT A SLUMP OF 5" ± 1" UNLESS NOTED OTHERWISE. <br />6. CONSTRUCT CONCRETE WALLS MONOLITHICALLY WITH ADJOINING COLUMNS UNLESS <br />SPECIFICALLY NOTED OTHERWISE. INSTALL CONCRETE FOR SUCH WALLS THAT IS THE SAME <br />TYPE AND STRENGTH AS SPECIFIED FOR COLUMNS. <br />7. UNLESS NOTED OTHERWISE, PROVIDE REINFORCING STEEL CONFORMING TO ASTM A 615, <br />GRADE 60. <br />8. PROVIDE WELDED WIRE REINFORCMENT (W.W.R.) IN FLAT SHEETS (ROLLS NOT PERMITTED) <br />CONFORMING TO ASTM A 1064. LAP WELDED WIRE REINFORCEMENT A MINIMUM OF 6" AT <br />EACH SPLICE. PLACE WELDED WIRE REINFORCEMENT 1 Y2" BELOW THE TOP OF <br />SLABS -ON -GRADE. <br />9. FIBER REINFORCING MAY BE SUBSTITUTED FOR WELDED WIRE REINFORCMENT (W.W.R.) IN <br />SLABS -ON -GRADE WITH THE APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD. <br />PROVIDE FIBER REINFORCING CONFORMING TO ASTM A 820, TYPE I AT 25 PCY DOSAGE. <br />10. WATERSTOPS: <br />A. PROVIDE AN ACTIVE SODIUM BENTONITE WATERSTOP IN ALL BELOW GRADE <br />CONCRETE CONSTRUCTION JOINTS THAT IS MANUFACTURED SPECIFICALLY FOR THIS <br />PURPOSE. <br />B. INSTALL THE WATERSTOP MATERIAL IN STRICT CONFORMANCE WITH THE <br />MANUFACTURER'S WRITTEN OR PUBLISHED INSTRUCTIONS. <br />C. IF AN ADHESIVE IS REQUIRED TO FIX THE WATERSTOP MATERIAL TO THE CONCRETE <br />SUBSTRATE ONLY USE MATERIAL THAT CONFORMS TO THE REQUIREMENTS OF THE <br />WATERSTOP MANUFACTURER. <br />11. UNLESS NOTED OTHERWISE, PROVIDE THE FOLLOWING CONCRETE COVER ON ALL <br />REINFORCING STEEL: <br />CONCRETE COVER <br />CONCRETE AGAINST EARTH (NOT FORMED): 3" <br />FORMED CONCRETE EXPOSED TO EARTH OR WEATHER: <br />#6 THROUGH #18 BARS: 211 <br />#5 BARS AND SMALLER: 1 Y210 <br />FORMED CONCRETE NOT EXPOSED TO EARTH OR WEATHER: <br />SLABS: %" <br />12. PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE. SPLICE REINFORCING <br />BARS ONLY AS SHOWN OR APPROVED. STAGGER SPLICES WHERE POSSIBLE. USE CLASS <br />"B" TENSION SPLICES UNLESS NOTED OTHERWISE INCLUDING DOWELS. <br />13. DO NOT LAP MORE THAN 50 PERCENT OF HORIZONTAL WALL REINFORCING IN A SINGLE <br />VERTICAL PLANE. <br />14. TIE ALL REINFORCING STEEL AND EMBEDDED ITEMS SECURELY IN PLACE PRIOR TO PLACING <br />CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF THE <br />REINFORCEMENT WITHIN SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. <br />15. "STICKING" DOWELS, ANCHOR RODS, OR OTHER EMBEDDED ITEMS INTO WET CONCRETE IS <br />NOT PERMITTED. <br />16. PROVIDE CORNER BARS AT ALL CORNERS AND INTERSECTIONS OF ALL FOOTINGS AND <br />WALLS. <br />17. CHAMFER OR ROUND ALL EXPOSED CORNERS A MINIMUM OF 3/4". <br />18. PROVIDE CONSTRUCTION OR CONTRACTION JOINTS IN SLABS ON GRADE SO THAT THE <br />MAXIMUM AREA OF SLAB BETWEEN JOINTS IS NO MORE THAN 400 SQUARE FEET AND THE <br />LENGTH BETWEEN CONTROL JOINTS IS NO MORE THAN 1 Y4 TIMES THE WIDTH BETWEEN <br />CONTRACTION JOINTS. <br />19. CONTRACTION OR CONSTRUCTION JOINTS: PROVIDE JOINTS UTILIZING THE DRY CUT <br />(SOFF-CUT) METHOD. <br />A. INITIATE SAW CUTTING AS SOON AS THE SLAB WILL SUPPORT THE WEIGHT OF THE SAW <br />AND OPERATOR WITHOUT CHIPPING, SPALLING, TEARING OR DISTURBING FINAL FINISH <br />(NORMALLY WITHIN 2 HOURS AFTER FINAL FINISHING AT EACH CONTROL JOINT <br />LOCATION). <br />a. SAW: PROVIDE A HUSQVARNA SOFF-CUT 150 SAW OR APPROVED EQUAL. <br />b. SPACING: PROVIDE JOINTS AT SPACING SHOWN ON PLAN. <br />c. DEPTH: PROVIDE JOINTS AT DEPTH SHOWN ON PLAN. <br />d. SAW CUT JOINTS INA NEAT, VERTICAL STRAIGHT LINE. <br />e. SAW CUT JOINTS TO BEY8" WIDTH. <br />B. THE SAW OPERATION SHALL BE CARRIED ON AS REQUIRED DURING BOTH DAY AND <br />NIGHT REGARDLESS OF CONDITIONS. <br />C. SAW JOINTS AT THE REQUIRED SPACING CONSECUTIVELY IN THE SEQUENCE OF THE <br />CONCRETE PLACEMENT. <br />a. A CHALK LINE FOR MARKING JOINT LOCATION SHALL NOT VARY MORE THAN Y4" FROM <br />THE TRUE JOINT ALIGNMENT. <br />b. PROTECT ALL JOINT INTERSECTIONS WITH "SOFF-CUT JOINT PROTECTOR, METEGER <br />MCGUIRE SPAL-PRO ROD" OR EQUAL. <br />D. WORKMEN AND INSPECTOR SHALL WEAR CLEAN, RUBBER -SOLED FOOTWEAR, AND THE <br />NUMBER OF PERSONS WALKING ON THE SLAB SHALL BE LIMITED TO THOSE ACTUALLY <br />PERFORMING THE SAWING OPERATION. <br />E. INITIAL JOINT CUTTING PROCEDURE: <br />a. ATTEMPT A 5 FOOT LONG CUT AND EVALUATE IT FOR REVELING OR SPALLING <br />BEFORE CUTTING ENTIRE SECTION. <br />b. WHEN FIBERS ARE PULLED UP, DELAY THE CUTTING AND REPEAT THE ABOVE <br />PROCEDURE UNTIL THE CUT REVEALS FIBERS. <br />F. IMMEDIATELY AFTER THE JOINT IS SAWED, THE SAW CUT AND ADJACENT CONCRETE <br />SURFACE SHALL BE THOROUGHLY CLEANED BY LIGHT SWEEP WITH A SOFT BROOM OR <br />DRY VACUUM. ANY MEMBRANE -CURED SURFACE DAMAGED DURING SAWING <br />OPERATIONS SHALL BE RE -SPRAYED. <br />G. PROVIDE THE NUMBER OF SAWING UNITS EQUIPMENT POWER TO COMPLETE THE <br />SAWING AT THE REQUIRED TIME. <br />a. HAVE AN AMPLE SUPPLY OF BLADES AND ANTI -RAVELING SKID <br />PLATES SHALL BE AVAILABLE ON THE JOB BEFORE CONCRETE <br />PLACEMENT IS STARTED. <br />b. PROVIDE AT LEAST ONE STANDBY SAWING UNIT IN GOOD WORKING <br />ORDER AT THE JOBSITE AT ALL TIMES DURING THE SAWING <br />OPERATION. <br />c. REPLACE SAW BLADES AND ANTI -RAVELING SKID PLATES AS REQUIRED BY THE SAW <br />MANUFACTURER. <br />20. THE LOCATION OF CONSTRUCTION JOINTS REQUIRES THE APPROVAL OF THE STRUCTURAL <br />ENGINEER OF RECORD. <br />a. UNLESS NOTED OTHERWISE, THOROUGHLY ROUGHEN (BY MECHANICAL MEANS) AND <br />CLEAN CONSTRUCTION JOINTS. <br />b. APPLY SLUSH COAT AS SPECIFIED. <br />21. ALL CONDUIT, SLEEVES AND PIPES EMBEDDED IN CONCRETE MUST CONFORM TO SECTION <br />20.7 OF ACI 318 AND THE FOLLOWING UNLESS NOTED OTHERWISE: <br />A. SLEEVES AND PIPES MUST BE PLACED SO THAT REINFORCING STEEL CAN BE PLACED <br />B. WITH THE SPECIFIED COVER AND CLEAR DISTANCE BETWEEN BARS. <br />C. THE CONCRETE COVERING OF PIPE AND SLEEVES MUST NOT BE LESS THAN ONE INCH. <br />D. CLEAR DISTANCE BETWEEN SUCH PIPES AND SLEEVES MUST NOT BE LESS THAN ONE <br />E. AND ONE-HALF INCHES. <br />F. CONDUIT AND PIPES PLACED IN SLABS MUST NOT BE LARGER IN OUTSIDE DIAMETER <br />G. THAN ONE-THIRD THE THICKNESS OF SLAB. <br />H. DO NOT PLACE CONDUIT IN ELEVATED SLABS. <br />22. THE PLACEMENT OF ALL REINFORCING STEEL MUST BE REVIEWED BY A PROFESSIONAL <br />ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS TO BE CONSTRUCTED OR BY <br />A REPRESENTATIVE RESPONSIBLE TO HIM (REF. ACE 318,26.13.1.2). <br />STRUCTURAL STEEL: <br />1. PROVIDE STRUCTURAL STEEL CONFORMING TO THE FOLLOWING STANDARDS: <br />A. AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION <br />B. AISC 360-10, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS <br />C. AISC 303-10, CODE OF STANDARD PRACTICE FOR STRUCTURAL STEEL BUILDINGS AND <br />BRIDGES <br />D. AISC 326-09, DETAILING FOR STEEL CONSTRUCTION, 3RD EDITION <br />2. SHOP DRAWINGS: <br />A. SUBMIT SHOP DRAWINGS PREPARED IN ACCORDANCE WITH AISC 326-09. <br />B. PROVIDE COMPLETE WELDING INFORMATION USING AWS SYMBOLS. <br />C. USE PREQUALIFIED WELDED JOINTS PER AISC AND AWS D1.1 "STRUCTURAL WELDING <br />CODE." <br />D. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED <br />BY THE STRUCTURAL ENGINEER OF RECORD. <br />3. UNLESS NOTED OTHERWISE PROVIDE STRUCTURAL STEEL CONFORMING TO: <br />A. WIDE FLANGE SHAPES: ASTM A992 <br />B. CHANNELS, ANGLES AND PLATES: ASTM A36 <br />C. HOLLOW STEEL SECTIONS (HSS): ASTM A500, GRADE B <br />D. ANCHOR RODS: ASTM F 1554, GRADE 36. <br />E. COMMON BOLTS: ASTM A307, GRADE A <br />4. BOLTED CONNECTIONS: <br />A. UNLESS NOTED OTHERWISE, MAKE ALL CONNECTIONS WITH 3/4" DIAMETER ASTM A 325 <br />BOLTS. <br />B. ASSEMBLE AND INSPECT BOLTED CONNECTIONS IN ACCORDANCE WITH RESEARCH <br />COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) "SPECIFICATION FOR JOINTS USING <br />HIGH STRENGTH BOLTS", 2014. <br />C. PROVIDE SNUG TIGHT JOINTS. <br />5. WELDED CONNECTIONS: <br />A. MAKE ALL WELDED CONNECTIONS IN ACCORDANCE WITH AWS D1.1-14 "STRUCTURAL <br />WELDING CODE", USING TYPE E70XX ELECTRODES. <br />B. EMPLOY ONLY CERTIFIED WELDERS. <br />C. MAINTAIN PROOF OF CERTIFICATION AT THE JOB SITE. <br />6. PROVIDE SPECIAL CONNECTIONS BETWEEN STEEL FRAMING COMPONENTS NOT DETAILED <br />BY THE STRUCTURAL ENGINEER OF RECORD DESIGNED BY A PROFESSIONAL ENGINEER <br />REGISTERED IN THE STATE WHERE THE PROJECT IS TO BE CONSTRUCTED INCLUDING BUT <br />NOT LIMITED TO BRACE END CONNECTIONS, MOMENT RESISTING CONNECTIONS, MODIFIED <br />BEAM SEAT CONNECTIONS, AND MEMBER SPLICE CONNECTIONS. <br />7. DO NOT USE GAS CUTTING TORCHES TO CORRECT FABRICATION ERRORS IN STRUCTURAL <br />STEEL FRAMING. <br />8. PROVIDE TEMPORARY BRACING FOR STRUCTURAL STEEL FRAMING UNTIL ALL PERMANENT <br />BRACING, MOMENT CONNECTIONS, AND FLOOR/ROOF DECKS (DIAPHRAGMS) ARE <br />COMPLETELY INSTALLED. <br />9. PAINT STRUCTURAL STEEL IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. DO NOT <br />PAINT STEEL SURFACES TO BE ENCASED IN CONCRETE, SURFACES TO RECEIVE <br />FIREPROOFING, CONNECTIONS DESIGNATED AS FRICTION TYPE, SURFACES TO BE WELDED, <br />OR SURFACES RECEIVING WELDED STUDS OR DEFORMED BAR ANCHORS ("DBNS") IN THE <br />FIELD. <br />COLD FORMED METAL FRAMING: <br />1. PROVIDE COLD -FORMED METAL FRAMING CONFORMING WITH THE FOLLOWING STANDARDS: <br />AISI S100-12 / S1.09 NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD -FORMED <br />STEEL STRUCTURAL MEMBERS. <br />2. PROVIDE CURTAIN WALL AND NON -LOAD BEARING WALL FRAMING INSTALLATION TO <br />ACCOMMODATE VERTICAL DISPLACEMENT OF THE PRIMARY STRUCTURE. <br />3. DESIGN SLIP TRACK USING THE GUIDELINES ESTABLISHED IN STEEL STUD MANUFACTURER'S <br />ASSOCIATION (SSMA) TECHNICAL NOTE NUMBER 3, PUBLISHED APRIL 2000. <br />4. PROVIDE STUDS, RUNNER TRACK, AND ASSOCIATED ACCESSORIES OF THE TYPE AND <br />THICKNESS INDICATED ON THE DRAWINGS. <br />5. PROVIDE STUDS, JOISTS, RUNNER TRACK, AND ACCESSORIES MANUFACTURED OF HOT DIP <br />GALVANIZED ASTM A 1003 STEEL WITH THE FOLLOWING YIELD STRENGTH: <br />33,000 PSI 43-MIL (18 GAGE) MEMBERS <br />50,000 PSI 54-MIL (16 GAGE), 68-MIL (14 GAGE), AND 97-MIL (12 GAGE) MEMBERS <br />6. SUBMIT SHOP DRAWINGS SHOWING THE SIZE OF ALL MEMBERS AND ALL CONNECTIONS <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS <br />TO BE CONSTRUCTED. <br />A. REVIEW OF SHOP DRAWINGS BY THE STRUCTURAL ENGINEER OF RECORD IS FOR: <br />1. GENERAL CONFORMANCE WITH THE CONTRACT DOCUMENTS REGARDING <br />ARRANGEMENT AND SIZES OF MEMBERS. <br />2. THE DESIGNER'S INTERPRETATION OF THE DESIGN LOADS AND CONTRACT <br />DOCUMENT DETAILS. <br />7. MINIMUM CONNECTIONS (UNLESS NOTED OTHERWISE ON THE DRAWINGS): <br />A. STUD TO STUD CONNECTIONS: A MINIMUM OF TWO 10 - 16 SELF TAPPING SCREWS. <br />B. STUD TO TRACK CONNECTIONS: TWO 10 - 16 SELF TAPPING SCREWS. <br />C. TRACK ON CONCRETE SLAB: 0.157" 0 X 1 Y4"POWER ACTUATED FASTENERS AT l'-6" ON <br />CENTER MAXIMUM AT NON-X-BRACE LOCATIONS. SPACING = 12" O.C. MAXIMUM AT <br />X-BRACE LOCATIONS. <br />D. MULTIPLE STUD JAMBS: #10 SCREWS AT 12" ON CENTER PENETRATING EACH MEMBER. <br />E. STUD TO WALL SHEATHING: Y2" X 1 %" BUGLE HEAD #6 SELF DRILLING SCREWS AT 8" <br />ON CENTER. <br />1. SEE ARCHITECTURAL DRAWINGS FOR EXACT SHEATHING TYPE. <br />F. STUD TO STRUCTURAL STEEL: AS SHOWN ON SECTIONS. <br />8. PROVIDE BRIDGING AND BRACING PER STUD MANUFACTURERS RECOMMENDATIONS. <br />9. REINFORCE EXTERIOR STUDS THAT ARE CUT TO INSTALL MECHANICAL OR ELECTRICAL <br />MATERIAL. SUBMIT REINFORCEMENT DETAIL FOR APPROVAL BEFORE PROCEEDING WITH <br />CONSTRUCTION. <br />10. ANY EXTERIOR BUILDING SINAGE PROVIDED BY THE OWNER IS TO HAVE THE SIGN FRAME <br />ATTACHED PER THE MANUFACTURER'S RECOMMENDATION TO EVERY COLD FORMED STEEL <br />WALL STUD THE SIGN FRAME CROSSES, BOTH TOP AND BOTTOM OF THE SIGN FRAME. <br />STRUCTURAL MASONRY: <br />1. PROVIDE STRUCTURAL MASONRY CONFORMING TO THE FOLLOWING STANDARDS: <br />A. ACI 530-13 / ASCE 5-13 / TMS 402-13, BUILDING CODE REQUIREMENTS FOR CONCRETE <br />MASONRY STRUCTURES. <br />B. ACI 530.1-13 / ASCE 6-13 / TMS 602-13, SPECIFICATIONS FOR CONCRETE MASONRY <br />STRUCTURES. <br />2. LOAD BEARING MASONRY WALLS ARE DESIGNED IN ACCORDANCE WITH CHAPTERS 1 AND 2 <br />OF ACI 530. <br />3. PROVIDE HOLLOW, LOAD BEARING CONCRETE MASONRY UNITS (CMU) CONFORMING TO <br />ASTM C 90 WITH A MINIMUM COMPRESSIVE STRENGTH OF MASONRY (F'M) OF 1500 PSI AND A <br />NET STRENGTH OF 2000 PSI ON THE NET CROSS -SECTIONAL AREA OF CMU DETERMINED IN <br />ACCORDANCE WITH ASTM C 140. <br />4. PROVIDE BRICK MASONRY UNITS CONSTRUCTED OF CLAY OR SHALE CONFORMING TO ASTM <br />C 652. <br />5. PROVIDE MORTAR CONFORMING TO ASTM C 270, TYPE S. STANDARD MORTAR BED JOINT <br />THICKNESS IS 3/8"AND MUST NOT VARY OUTSIDE OF THE RANGE BETWEEN ONE QUARTER <br />INCH AND ONE HALF INCH. DO NOT USE AIR ENTRAINED MORTAR. <br />6. PROVIDE GROUT FOR REINFORCED MASONRY CONFORMING TO ASTM C 476 WITH MINIMUM <br />COMPRESSIVE STRENGTH OF 2500 PSI AND A MINIMUM SLUMP OF 10". <br />7. PROVIDE STEEL REINFORCEMENT IN MASONRY WALLS CONFORMING TO ASTM A615, GRADE <br />60. <br />8. PROVIDE MASONRY TIES AND ANCHORS OF THE TYPE AND SPACING AS DETAILED ON THE <br />STRUCTURAL DRAWINGS AND IN CONFORMANCE WITH ASTM A82. <br />9. PROVIDE LADDER TYPE HORIZONTAL JOINT REINFORCING CONFORMING TO ASTM A951 IN <br />ALL MASONRY WALLS. UNLESS NOTED OTHERWISE, PLACE 9 GAGE ZINC COATED LADDER <br />TYPE HORIZONTAL JOINT REINFORCING AT 16" ON CENTER. LAP HORIZONTAL JOINT <br />REINFORCING MINIMUM 12". USE PREFABRICATED'L'S AND'T'S AT CORNERS AND <br />INTERSECTIONS. <br />10. LAY ALL MASONRY UNITS IN RUNNING BOND. <br />11. FOR GROUTED WALLS: <br />A. THE MAXIMUM HEIGHT OF GROUT LIFTS MUST NOT EXCEED 64'. <br />B. THE MAXIMUM UN -GROUTED HEIGHT OF CMU WALLS PRIOR TO GROUTING MUST NOT <br />EXCEED 64". <br />C. CONSOLIDATE AND RECONSOLIDATE GROUT IN ACCORDANCE WITH PARAGRAPH 3.5.E <br />OF ACI 530.1. <br />12. REINFORCEMENT: <br />A. DETAIL REINFORCEMENT IN LOAD BEARING CMU WALLS IN ELEVATION ON SHOP <br />DRAWINGS. <br />B. LAP VERTICAL MASONRY WALL REINFORCING AS SHOWN IN THE MASONRY LAP <br />LENGTH SCHEDULE AND PROVIDE MINIMUM BAR SPLICE LENGTH. <br />13. PROVIDE VERTICAL CONTROL JOINTS IN ALL MASONRY WALLS NOT RETAINING EARTH. <br />UNLESS NOTED OTHERWISE ON THE ARCHITECTURAL DRAWINGS, PLACE VERTICAL <br />CONTROL JOINTS AT THREE TIMES THE WALL STORY HEIGHT, BUT NOT CLOSER THAN 26-0- <br />ON CENTER OR FARTHER THAN 40'-0" ON CENTER. <br />14. UNLESS NOTED OTHERWISE, PROVIDE MINIMUM (1) #5 VERTICAL BAR, GROUTED FULL STORY <br />HEIGHT, AT EACH SIDE OF OPENINGS AND AT ALL CORNERS AND ENDS OF WALLS, <br />INCLUDING BOTH SIDES AT ENDS OF WALL PANELS AT VERTICAL CONTROL JOINTS. <br />15. UNLESS NOTED OTHERWISE, ANCHOR SIDES AND TOPS OF MASONRY WALL PANELS TO THE <br />STRUCTURE BY DOVETAIL ANCHORS, METAL STRAPS, OR EQUIVALENT. <br />16. PLACE CONNECTORS FOR MASONRY VENEERS AT NOT MORE THAN 16"ON CENTER <br />VERTICALLY OR 24" ON CENTER HORIZONTALLY. <br />17. PROVIDE A CONTINUOUS BOND BEAM AT THE TOP OF ALL MASONRY WALLS. UNLESS NOTED <br />OTHERWISE REINFORCE BOND BEAMS WITH (2) #4 CONTINUOUS REINFORCING BARS. <br />18. PROVIDE LEVEL B QUALITY ASSURANCE AS DESCRIBED IN TABLE 4 OF ACI 530.1-13 / ASCE <br />6-13 / TMS 602-13. <br />19. SAMPLE AND TEST GROUT IN ACCORDANCE WITH ARTICLES 1.4 B AND 1.6 OF ACI 530.1-13 <br />ASCE 6-13 / TMS 602-13. <br />1 <br />2. <br />POST -INSTALLED ANCHORS: <br />GENERAL <br />A. PRE -CONSTRUCTION DUTIES OF THE CONTRACTOR: <br />1. ARRANGE FOR AN ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE ONSITE <br />INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. <br />2. PROVIDE THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED <br />CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO INSTALL <br />ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS. <br />B. INSTALL POST -INSTALLED ANCHORS ONLY WHERE SPECIFIED ON THE CONSTRUCTION <br />DOCUMENTS. <br />C. OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING <br />POST -INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST -IN -PLACE <br />ANCHORS. <br />D. ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS <br />AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN <br />ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS. <br />E. EXISTING REINFORCING BARS AND OTHER EMBEDDED MATERIAL CONTAINED IN THE <br />CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. <br />1. CONTRACTOR REVIEW THE EXISTING STRUCTURAL DRAWINGS AND UNDERTAKE TO <br />LOCATE THE POSITION OF MATERIAL EMBEDDED IN THE CONCRETE AT THE <br />LOCATIONS OF THE DETAILED ANCHORS, BY HILTI FERROSCAN, GPR, X-RAY, <br />CHIPPING OR OTHER MEANS UNLESS IT IS NOTED ON THE DRAWINGS THAT THE BARS <br />CAN BE CUT. <br />F. DRILL AND CLEAN HOLES IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN <br />INSTRUCTIONS. <br />G. SUBMIT SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED <br />BELOW TO THE ENGINEER -OF -RECORD PRIOR TO USE ALONG WITH: <br />1. PROVIDE CALCULATIONS THAT ARE PREPARED & SEALED BY A REGISTERED <br />PROFESSIONAL ENGINEER. <br />2. PROVIDE CALCULATIONS THAT DEMONSTRATE THE SUBSTITUTED PRODUCT IS <br />CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE <br />SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR <br />STANDARD(S) AS REQUIRED BY THE BUILDING CODE. <br />3. INCLUDE CONSIDERATION OF CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION <br />TEMPERATURE IN SUBSTITUTION REQUEST. <br />4. EVALUATION OF SUBSTITUTIONS WILL BE BASED ON THEIR HAVING AN ICC ESR <br />SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, <br />LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF <br />COMPREHENSIVE INSTALLATION INSTRUCTIONS. <br />CONCRETE ANCHORS <br />A. MEDIUM DUTY MECHANICAL ANCHORS FOR USE IN CRACKED AND UN -CRACKED <br />CONCRETE THAT HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI <br />355.2 AND ICC-ES AC193. PRE -APPROVED MECHANICAL ANCHORS INCLUDE: <br />1. HILTI KWIK BOLT-TZ EXPANSION ANCHORS (ICC ESR-1917) <br />2. HILTI KWIK HUS-EZ AND KWIK HUS EZ-1 SCREW ANCHORS (ICC ESR-3027) <br />3. SIMPSON STRONG -TIE "TITEN-HD' (ICC-ES ESR-2713) <br />4. SIMPSON STRONG -TIE "STRONG -BOLT 2" (ICC-ES ESR-3037) <br />5. DEWALT POWER -STUD + SD2 (ICC-ES-ESR 2502) <br />6. DEWALT SCREW -BOLT + (ICC-ES-ESR 3889) <br />B. HEAVY DUTY MECHANICAL ANCHORS FOR CRACKED AND UN -CRACKED CONCRETE <br />USE: <br />1. HILTI HDA UNDERCUT ANCHORS (ICC ESR 1546) <br />2. HILTI HSL-3 EXPANSION ANCHORS (ICC ESR 1545) <br />3. SIMPSON STRONG -TIE "TORQ-CUT" (ICC-ES ESR-2705) <br />4. DEWALT "ATOMIC +" ANCHOR (ICC-ES-ESR 3067) <br />C. ADHESIVE ANCHORS FOR USE IN CRACKED AND UN -CRACKED CONCRETE THAT HAVE <br />BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC308. <br />PRE -APPROVED ADHESIVE ANCHORS INCLUDE: <br />1. HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HIT-Z ROD (ICC ESR-3187) <br />2. HILTI HIT -RE 500-V3 EPDXY ADHESIVE ANCHORING SYSTEM WITH HAS-E THREADED <br />ROD (ICC ESR-3814) FOR SLOW CURE APPLICATIONS. <br />3. SIMPSON STRONG -TIE "SET-3G" (ICC-ES ESR 4057). <br />4. DEWALT "PURE 110 +" STANDARD CURE EPDXY (ICC-ES-ESR 3298) <br />5. DEWALT "AC100 +" FAST CURE/COLD WEATHER (ICC-ES-ESR 4027) <br />6. PROVIDE STEEL ANCHOR ELEMENT CONSISTING OF CONTINUOUSLY THREADED <br />ROD CONFORMING TO ASTM, A36 OR ASTM F 1154, GRADE 36. <br />3. MASONRY ANCHORS <br />A. ANCHORAGE TO SOLID -GROUTED CONCRETE MASONRY <br />1. MECHANICAL AND CONCRETE SCREW ANCHORS FOR USE IN SOLID -GROUTED <br />CONCRETE MASONRY MUST HAVE BEEN TESTED AND QUALIFIED FOR USE IN <br />ACCORDANCE WITH ICC-ES AC01 OR AC106, RESPECTIVELY. PRE -APPROVED <br />MECHANICAL AND CONCRETE SCREW ANCHORS INCLUDE: <br />a. SIMPSON STRONG -TIE "STRONG BOLT2" (IAMPO UES ER-265) <br />b. SIMPSON STRONG -TIE "TITEN-HD' (ICC-ES ESR-1056) <br />c. HILTI KWIK HUS-EZ SCREW ANCHOR (ICC ESR-3056) <br />d. HILTI KWIK BOLT-3 EXPANSION ANCHORS (ICC ESR-1385) <br />e. DEWALT "SCREW -BOLT +" (ICC-ES-ESR 4042) <br />f. DEWALT "POWIF-R-STUD + SD1" (ICC-ES-ESR 2966) <br />2. ADHESIVE ANCHORS FOR USE IN SOLID -GROUTED CONCRETE MASONRY MUST <br />HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC58. <br />PRE -APPROVED ADHESIVE ANCHORS INCLUDE: <br />a. SIMPSON STRONG-TIE"SET-XP" (ICC-ES ESR-1772) <br />b. SIMPSON STRONG -TIE "AT-XP' (IAMPO UES ER-281) <br />c. HILTI HIT-HY 70 MASONRY ADHESIVE ANCHORING SYSTEM (ICC-ES ESR-2682) <br />d. PROVIDE STEEL ANCHOR ELEMENT CONSISTING OF CONTINUOUSLY THREADED <br />ROD CONFORMING TO ASTM, A36 OR ASTM F 1554, GRADE 36. <br />e. DEWALT "AC100 + GOLD" (ICC-ES-ESR 3200) <br />B. ANCHORAGE TO HOLLOW CONCRETE MASONRY/U NREIN FORCED CLAY BRICK <br />MASONRY <br />1. SCREW ANCHORS FOR USE IN HOLLOW CONCRETE MASONRY MUST HAVE BEEN <br />TESTED AND QUALIFIED IN ACCORDANCE WITH ICC-ES AC106. PRE -APPROVED <br />SCREW ANCHORS INCLUDE: <br />a. SIMPSON STRONG -TIE "TITEN-HD"(ICC-ES ESR-1056) <br />b. HILT[ KWIK HUS-EZ SCREW ANCHOR (ICC ESR-3056) <br />c. DEWALT "AC100 + GOLD" (ICC-ES ESR-4105) <br />2. ADHESIVE ANCHORS WITH SCREEN TUBES THAT ARE TESTED AND QUALIFIED IN <br />ACCORDANCE WITH ICC-ES AC58 OR AC60, AS APPROPRIATE. USE THE APPROPRIATE <br />SCREEN TUBE AS RECOMMENDED BY THE ADHESIVE MANUFACTURER. PRE -APPROVED <br />ADHESIVE ANCHORS WITH SCREEN TUBES INCLUDE: <br />a. SIMPSON STONG-TIE "SET-XP" (IAMIPO LIES ER-265) <br />b. SIMPSON STRONG-TIE"ACRYLIC-TIE' (ICC-ES ER-5791) <br />c. SIMPSON STRONG -TIE "ET" (ICC-ES ER-4945) <br />d. HILTI HIT-HY 70 MASONRY ADHESIVE ANCHORING SYSTEM (ICC ESR-3342) <br />e. DEWALT "AC100 + GOLD" (ICC-ES ESR-3200) <br />e. PROVIDE STEEL ANCHOR ELEMENT CONSISTING OF CONTINUOUSLY THREADED <br />ROD. <br />DESIGN LOADS: <br />1. LIVE LOADS: <br />UNIFORM CONCENTRATED <br />STAIR 100 PSF ON 300 LB. ON AREA <br />STAIR TREADS OF 4 <br />SQUARE INCHES <br />STORAGE 125 PSF <br />CORRIDORS 100 PSF <br />ROOF 20PSF <br />OA 0 RT"T kil 11191 9 A <br />ULTIMATE WI D SPEED, VULT <br />138 MPH <br />NOMINAL DESIGN WIND SPEED, VASD <br />107 MPH <br />RISK CATEGORY <br />11 <br />WIND EXPOSURE <br />C <br />INTERNAL PRESSURE COEFFICIENT <br />±0.18 <br />COMPONENTS AND CLADDING <br />PRESSURES - BUILDING A <br />SEE 1 / SO.2 AND 2 / SO.2 <br />COMPONENTS AND CLADDING <br />PRESSURES - BUILDINGS B,C,D,E,F,G <br />SEE 3 / SO.2 AND 4 / SO.2 <br />3. FLOOD DESIGN DATA: <br />FLOOD HAZARD ZONE DESIGNATION <br />AE <br />ELEVATION OF LOWEST FLOOR: <br />113'-0" <br />bennett&pless 10 <br />Experience Structural Expertise <br />Atlanta, Boca Raton, Charlotte, Chattanooga, Orlando <br />1964 - 2019 Celebrating 55 Years <br />of Structural Excellence <br />47 Perimeter Center East, Suite 500 <br />Atlanta, Georgia 30346 <br />Tel. 678 990 8700 Fax. 678 990 8701 <br />Copyright 2019 - Bennett & Pless, Inc. <br />All Rights Reserved <br />B & P Job Number 18161 <br />ST4XE OF <br />DR! <br />04-03-2019 <br />LU LU LU Q� <br />LLI I E, D, w . 0 W, <br />OJ 90 0� < Z < <br />< w <br />j <.,,<,i <br />< LLJ 0 <br />(D _w, �<- �0- F0- L �- <br />0 co I <br />cy- < , zi < C, Go- <br />L,j < <br />C� z U w 0 <br />z w 'z z cif <br />z: v) 3 0 Z <br />< w 10 10 LLj 0 <br />U <br />0 LL, M <br />z>_0B0w_Q,z 7_LL,=F-0=) <br />ww �; F_ U <br />0 w LU <br />LU F- j:) w z <br />oo� a- L) 0 - -i = < Z <br />(500 'L 0 <br />C�OLUG�LUL,UOZL , <br />LU Of �- 0- F- 0� z < E < Uj a, LLJ Z <br />W a- Lu < - Lu < L6 < <br />CL <br />W LLI U ch U LIJ LU F_ LU U < <br />of w fy 0� F_ < z �; = L/) Q� <br />< in < 0- FI-) 0 0 1— W> F_ C� C) <br />a) <br />bju <br />03 <br />;-.4 <br />0 <br />4_j <br />>1 <br />r=51 <br />ISSUE: FOR CONSTRUCTION <br />REVISIONS: I I <br />PROJECT NUMBER <br />201812 <br />DATE 04-03-2019 <br />I I SHEET NUMBER I I <br />S091 <br />