Laserfiche WebLink
4 <br />RDOOTYPES <br />\ <br />, <br />v. .R. <br />...` <br />e <br />x� <br />, �..., <br />s. <br />Y <br />s> \. <br />,. \\n <br />,r•� <br />_...ate. .. , <br />,. .. ..,_ .. ,. .. ... <br />Nominal Size DOOR FRAME FIRE RATING <br />O N O <br />-C U) <br />l cU Z3 U O N N E O <br />I; u <br />Q D O <br />O <br />? _ O iL iL <br />IEX - - - - - - - - - - - - <br />D <br />P ! <br />I IL it Al 310" 6'8" 1 3/4" Swing Simple SCWD PT A HM PT A 60 20 <br />TYPE A TYPE B TYPE C TYPED TYPE E TYPE F <br />A2 3'0" 618" 1 3/4" Swing Simple SCWD PT A HM PT A 60 20 <br />B1,B2 3'0" 618" 1 3/8" Swing Simple MDF PT A WD PT C - - <br />C1 310" 618" 13/8" Bi-fold MDF PT B WD PT D - - <br />C2 40" 618" 13/8" Slider MDF PT C WD PT D - - <br />D1 31011 61811 1 3/8" Swing Simple SCWD PT A HM PT A - - <br />FRAM E TYPES El 610" 61811 1 3/4" Swing Bipari• SCWD PT D HM PT B 60 20 <br />TYPE A <br />5 <br />TYPE B <br />F1 <br />310" <br />61811 <br />GI <br />310" <br />61811 <br />H1 <br />2110" <br />61811 <br />H2 <br />211011 <br />618" <br />H3 <br />2' 10" <br />6'8" <br />HARDWARE NOTES: <br />Existing Stair Door <br />SCWD <br />I PT <br />E <br />HM <br />1 3/4" <br />Swing Simple <br />Insul, <br />PT <br />F <br />HM <br />Fiberglass <br />1 3/4" <br />Existing Patio Door <br />Insul, <br />Fiberglass <br />PT <br />F <br />HM <br />1 3/4" <br />Existing Patio Door <br />Insul, <br />Fiberglass <br />PT <br />F <br />HM <br />1 3/4" <br />Existing Patio Door <br />Insul, <br />Fiberglass <br />PT <br />F <br />HM <br />1. ALL HARDWARE SHALL BE GRADE 2, <br />2, HARWARE FINISHES TO MATCH EXISTING. <br />3. PROVIDE LEVER SETS ON ALL DOORS. <br />4. SELF CLOSING DEVICES (CLOSERS OR SPRING HINGES) SHALL BE <br />PROVIDED ON ALL FIRE RATED DOORS. <br />5. PROVIDE SCHLAGE M490P/M492P OR EQUAL WHERE MAG LOCK <br />IS INDICATED. <br />6. PROVIDE SCHALGE SERIII-W SCRAMBLE KEYPAD OR EQUAL WHERE <br />KEYPAD IS INDICATED. <br />7. PROVIDE SCHLAGE CT5000 CONTROLLER OR EQUAL AS REQUIRED <br />FOR ACCESS CONTROLLED DOORS, <br />8. GC SHALL COORDINATE ALL NECESSARY POWER AND LOW VOLTAGE <br />FOR ACCESS CONTROLLED DOORS WITH DOOR HARDWARE <br />SUBCONTRACTOR AND ELECTRICAL SUBCONTRACTOR. <br />9. ALL ACCESS CONTROLLED DOORS SHALL HAVE SAME KEYCODE, <br />10. ALL KEYING SHALL BE REVIEWED AND APPROVED BY OWNER. GC TO <br />COORDINATE DIRECTLY WITH OWNER. <br />PT <br />A <br />60 <br />45 <br />PT <br />A <br />- <br />- <br />PT <br />A <br />- <br />- <br />PT <br />A <br />- <br />- <br />PT <br />A <br />- <br />- <br />HARDWARE I GENERAL <br />� <br />O <br />N <br />D <br />Cn <br />U <br />� <br />U <br />N <br />- <br />- <br />EXISTING DOOR TO REMAIN <br />a » <br />MATCH EXISTING DOORS TO REMAIN. RE -USE STOCKPILED DOORS TO <br />» `° <br />Z-1 F <br />PASSAGE <br />» <br />THE GREATEST EXTENT POSSIBLE <br />Z-1G <br />ENTRANCE <br />MATCH EXISTING DOORS TO REMAIN. RE -USE STOCKPILED DOORS TO <br />THE GREATEST EXTENT POSSIBLE <br />MATCH EXISTING DOORS TO REMAIN. RE -USE STOCKPILED DOORS TO <br />STATE OF FLORIDA <br />-- - <br />Z-lA <br />PASSAGE <br />THE GREATEST EXTENT POSSIBLE <br />REGISTERED ARCHITECT <br />Z c <br />�20 <br />- <br />- <br />BIFOLD DOOR HARDWARE. PROVIDE PULL KNOB <br />ROBERT A, GLISSON <br />- <br />< NpwU <br />AR0015123 <br />0 <br />- <br />- <br />SLIDER DOOR HARDWARE. PROVIDE RECESSED PULL <br />w z <br />Z Q <br />Z-lA <br />OFFICE <br />MATCH KEYING WITH EXISTING EMPLOYEE LOUNGE WITHIN MEMORY UNIT. <br />ACCESS <br />MATCH EXISTING DOORS TO REMAIN. PROVIDE MAGLOCK, SCRAMBLE KEYPAD ON BOTH <br />Z-2B <br />CONTROLLED <br />SIDES, DOORS SHALL NOT UNLOCK UPON ACTIVATION OF FIRE ALARM OR LOSS OF <br />POWER. PROVIDE BATTERY BACKUP. <br />ACCESS <br />PROVIDE MAG LOCK, SCRAMBLE KEYPAD ON BOTH SIDES. DOORS SHALL NOT UNLOCK <br />Z-1 B <br />CONTROLLED <br />UPON ACTIVATION OF FIRE ALARM OR LOSS OF POWER. PROVIDE BATTERY BACKUP. <br />E-lA <br />ENTRANCE <br />MATCH EXISTING PATIO DOORS. <br />E-lA <br />ENTRANCE <br />REPLACE EXISTING HINGES WITH SWING CLEAR FULL MORTISE HINGES. <br />- <br />- <br />PROVIDE DEADBOLT KEYED ON BOTH SIDES TO LOCK DOOR <br />E-1 C <br />PANIC <br />PROVIDE HARDWARE TO LOCK DOOR AT NIGHT TO PREVENT ACCESS FROM OUTSIDE, <br />THE COMMONS <br />ON PRETTY POND <br />38130 Pretty Pond Road <br />Zephyrhills, FL 33540 <br />HARDWARE SET DESCRIPTIONS NOTE: NOT ALL DOOR HARDWARE PACKAGES SHOWN MAY BE APPLICABLE TO THIS PROJECT. <br />E-lA LOCK <br />E-1 B LOCK/CLOS <br />E-1 C PANIC <br />E-1 D PUSH/PULL <br />E-1 E DEADLOCK <br />E-2A LOCK <br />E-26 PANIC 1 <br />E-2C PANIC 2 <br />E-21D PUSH/PULL <br />3 - HINGES <br />3 - HINGES <br />3 - HINGES <br />3 - HINGES <br />3 - HINGES <br />6 - HINGES <br />6 - HINGES <br />6 - HINGES <br />6 - HINGES <br />1 - LOCK <br />1 - LOCK <br />1 -PANIC DEVICE <br />1 - DEAD LOCK <br />1 - LOCK <br />1 - LOCK <br />2 - PANIC DEVICE <br />2 - PANIC DEVICE <br />1 - DEAD LOCK <br />1 - PHOLD <br />1 -CLOSER <br />1 -PANIC TRIM <br />1 - PUSH PLATE <br />1 - PHOLD <br />2 - FLUSH BOLTS <br />2 - PANIC TRIM <br />2 - PANIC TRIM <br />2 - PUSH PLATES <br />c <br />O <br />1 -SWEEP <br />-CLOSER <br />1 - PULL PLATE <br />1 -SWEEP <br />2 - CLOSERS <br />1 - FLUSH BOLTS <br />2 - CLOSERS <br />2 - PULL PLATES <br />1 - W'STRIP <br />1 - PHOLD1 <br />1 - T'HOLD <br />1 - CLOSER <br />1 - W'STRIP <br />1 - T'HOLD <br />1 - LOCK <br />1 - PHOLD <br />2 - FLUSH BOLTS <br />,c <br />1 SWEEP <br />1 - W'STRIP <br />1 -SWEEP <br />1 - PHOLD <br />1 - DEADBOLT LOCK <br />2 - SWEEPS <br />1 - T'HOLD <br />2 - SWEEPS <br />2 - CLOSERS <br />w <br />1 - W'STRIP <br />1 -SWEEP <br />1 -W'STRIP <br />2 - SWEEPS <br />1 - W'STRIP <br />1 - T'HOLD <br />1 - DOUBLE CYLINDER <br />1 - W'STRIP <br />1 - ASTRAGAL <br />1 - W'STRIP <br />1 - ASTRAGAL <br />2 - SWEEPS <br />1 - ASTRAGAL <br />2 - LOCKS (OPT) <br />1 -W'STRIP <br />1 - ASTRAGAL <br />Z-1 A LOCK <br />Z-1 B LOCK/CLOS. <br />Z-1 C PANIC <br />Z-1 D PUSH PULL <br />Z-1 E DEADLOCK <br />Z-1 F LOCK/SELF CLOSE <br />Z-1 G LOCK/SELFCLOS <br />Z-1 H PUSH PUSH <br />3 - HINGES <br />3 - HINGES <br />3 - HINGES <br />3 - HINGES <br />3 - HINGES <br />3 - SPRING HINGES W/ <br />3 - SPRING HINGES W/ <br />3 - HINGES <br />1 - LOCKSET <br />1 - LOCKSET <br />1 -PANIC DEVICE <br />1 - PUSH PLATE <br />1 - LOCK <br />SECURITY FASTNERS <br />SECURITY FASTNERS <br />2 - PUSH PLATE <br />1 -STOP <br />1 - CLOSER <br />1 -PANIC TRIM <br />1 - PULL PLATE <br />1 - DEADBOLT LOCK <br />1 - LOCKSET <br />1 -TUBULAR INTERCON <br />1 -CLOSER <br />1 -STOP <br />1 - CLOSER <br />1 -CLOSER <br />1 -CLOSER <br />1 -STOP <br />LOCK W/ DEADBOL <br />1 -STOP <br />1 -STOP <br />1 -STOP <br />1 - ONEWAY VIEWER <br />1 -STOP <br />c <br />Z-2A LOCK <br />Z-21B LOCK/CLOSER <br />Z-2C 1 PANIC <br />Z-2D 2 PANIC <br />Z-2E PUSH PULL <br />Z-2F DOUBLE ACTING <br />Lu <br />z <br />6 - HINGES <br />6 - HINGES <br />6 - HINGES <br />6 - HINGES <br />6 - HINGES <br />4 - DOUBLE ACTING <br />1 - LOCKSET <br />1 - LOCKSET <br />1 - PANIC DEVICE <br />2 - PANIC DEVICES <br />2 - PUSH PLATES <br />DOOR PIVOT <br />1 - FLUSH BOLTS <br />1 - FLUSH BOLTS <br />1 - PANIC TRIM <br />2 - PANIC TRIMS <br />2 - PULL PLATES <br />4 - PUSH PLATES <br />2 - STOPS <br />2 - STOPS <br />2 - FLUSH BOLTS <br />2 - CLOSERS <br />2 - CLOSERS <br />2 - STOPS <br />2 - CLOSERS <br />2 - CLOSERS <br />2 - STOPS <br />2 - STOPS <br />2 - STOPS <br />2 - LOCKS <br />FLAME SPREAD <br />INTERIOR WALL AND CEILNG FINISH REQUIREMENTS <br />DOOR NOTES & REMARKS <br />Group <br />Vertical exits and exit <br />Exit access corridors <br />Rooms and enclosed <br />passageways (a,b) <br />and other exitways <br />spaces (c) <br />B <br />A <br />B <br />C <br />DOOR DIMENSIONING: (THE DOOR SIZE SHALL BE GOVERENED BY THE DOOR SCHEDULE) <br />1. ALL DOOR IN A FRAMED PARTITION WALL ARE TO BE LOACTED BY ONE OF THE FOLLOWING- <br />a.) Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 sq <br />ft of applied surface area in the grade lobby where applied directly to a noncombustible base or over <br />A. IF THE DOOR IS LOCATED CLOSE TO ANOTHER WALL AT A RIGHT ANGLE PROVIDE MIN 4" <br />furring strips applied to a noncombustible base and fireblocked as required by section 803,3.1. <br />RETURN (TYP). <br />B. THE DOOR IS CENTERED IN A WALL. <br />b.) In vertical exits of buildings less than three stories in height of other than Group 1-3, Class B interior finish <br />C. OR AS DIMENSIONED ON THE PLAN. <br />for unsprinklered buildings and Class C interior finish for sprinklered buildings shall be permitted. <br />2. CONTRACTOR TO COORDINATE ALL REQUIRED ROUGH OPENINGS W/ THE DOOR MANUFACTURER <br />c.) Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. <br />Where a fire -resistance rating is required for structural elements, the enclosing partitions shall extend from <br />DOOR NOTES: <br />the floor to ceiling. Partitions that do not comply with this shall be considered enclosing spaces and the <br />rooms or spaces on both sides shall be considered one. In determining the applicable requirements for <br />rooms and enclosed spaces, the specific occupancy thereof shall be the governing factor regardless of <br />1. ALL DOORS' TYPE, STYLE & HARDWARE SHALL MATCH EXISTING. CONTRACTOR SHALL <br />the group classification of the building or structure. <br />COORDINATE ALL HARDWARE & CARD ACCESS REQUIREMENT WITH OWNER. <br />2, G.C. TO COORDINATE DOOR MANUFACTURERS UNIT DIMENSION WITH REQUIRED ROUGH <br />OPENING. <br />3. CONTACT ARCHITECT IF THERE IS A DISCREPANCY BETWEEN DOOR SIZE SHOWN AND ACTUAL <br />OPENING, <br />4. REFER TO MANUFACTURER SPECIFICATIONS FOR ALL DOOR AND FRAME REQUIREMENTS AND <br />INSTALLATION RECOMMENDATIONS, <br />5. PROVIDE 1/4" LABELED CLEAR TEMPERED GLASS AT NONRATED DOORS, WHEN APPLICABLE <br />6. PROVIDE LABELED FIRE RATED GLASS WHEN APPLICABLE. <br />4 3 2 <br />- <br />10/15/13 <br />PERMIT SET <br />- <br />8/30/13 <br />DESIGN DEVELOPMENT SET <br />Mark <br />I <br />Date <br />Description <br />SAFETY GLAZING NOTES & REMARKS <br />Issue/Revision <br />Revision <br />Project ID <br />13016 <br />CAD File Name <br />Filename <br />SAFETY GLAZING SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: <br />Drawn By <br />APM <br />Reviewed By <br />JS <br />A) INGRESS AND EGRESS DOORS <br />Plot Date: <br />00/00/00 <br />B) FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SWINGING DOORS <br />Record Date: <br />00.00.00 <br />Sheet Title <br />C) DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND <br />SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS <br />WHERE THE BOTTOM EDGE OF THE THE GLAZING IS LESS THAN 60" ABOVE THE DRAIN OUTLET, <br />D) INDIVIDUAL FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL <br />DOOR SCHEDULE <br />EDGE IS WITHIN A 24" ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS <br />LESS THAN 60" ABOVE THE FLOOR OR WALKING SURFACE. <br />_ <br />E) INDIVIDUAL OR OPERABLE PANEL, OTHER THAN THOSE DESCRIBED ABOVE THAT MEETS ALL OF THE <br />FOLLOWING CONDITIONS: <br />1. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. <br />2. BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR <br />3. TOP EDGE GREATER THAN 36" ABOVE FLOOR <br />SHEET SCALE: NTS <br />4. ONE OR MORE WALKING SURFACES WITHIN 36" HOR. OF THE PLANE OF THE GLAZING <br />5. ALL GLAZING IN RAILINGS REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE <br />INCLUDING STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN -FILL PANELS <br />Drawing No. <br />F) GENERAL CONTRACTOR (G.C.) TO VERIFY REQUIREMENTS FOR TEMPERED GLAZING PER ALL <br />APPLICABLE CODES. <br />G) G.C. TO DETERMINE MINIMUM GLASS THICKNESS PER ALL APPLICABLE CODES <br />A-6,1 <br />H) GLAZING SEALANTS SHALL COMPLY WITH SEALANT AND GLASS MANUFACTURERS TO SUIT <br />PARTICULAR PROJECT APPLICATION ANDD SURFACES CONTACTED. COLOR SHALL MATCH <br />ADJACENT SURFACES, <br />1 <br />