Laserfiche WebLink
5 <br />4 <br />3 <br />2 <br />1 <br />I <br />14 <br />A <br />GENERAL NOTES: <br />1. CONTRACTOR IS RESPONSIBLE FOR AND SHALL VERIFY AND <br />COORDINATE ALL DIMENSIONS AND DETAILS BEFORE PROCEEDING WITH <br />WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE <br />ATTENTION OF THE ARCHITECT AND ENGINEERS. <br />2. DETAILS SHOWN IN ANY SECTION APPLY TO ALL SIMILAR SECTIONS AND <br />CONDITIONS UNLESS NOTED OTHERWISE. <br />3. CONTRACTOR SHALL FULLY BRACE AND OTHERWISE PROTECT ALL WORK <br />IN PROGRESS UNTIL THE BUILDING IS COMPLETED. <br />4. ALL STRUCTURAL ITEMS FOR THIS PROJECT HAVE BEEN DESIGNED IN <br />ACCORDANCE WITH APPROPRIATE PROVISIONS OF EACH OF THE <br />FOLLOWING: <br />A. THE FLORIDA BUILDING CODE, 2010 EDITION. <br />B. ACI STANDARD 318-08 BUILDING CODE REQUIREMENTS FOR <br />REINFORCED CONCRETE. <br />C. BUILDING CODE REQUIREMENTS FOR MASONRY Q STRUCTURES (ACI <br />530-08/ASCE 5-10/TMS 402-05). <br />D. AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND <br />ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" NINTH EDITION. <br />E. AMERICAN FOREST AND PAPER ASSOCIATION, NATIONAL DESIGN <br />SPECIFICATION 2005 EDITION. <br />F. ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER <br />STRUCTURES". <br />5. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH <br />THE SPECIFICATIONS AND THE ARCHITECTURAL AND MECHANICAL <br />DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ARCHITECT PRIOR TO <br />PERFORMING WORK. IN CASE OF CONFLICT THE MOST STRINGENT <br />CONDITION SHALL APPLY. <br />6. ALL DIMENSIONS MUST BE COORDINATED WITH ARCHITECTURAL <br />DRAWINGS AND WITH EQUIPMENT MANUFACTURER (I.E. WINDOW, DOOR, <br />AIR HANDLER, ETC.). CONTRACTOR MUST OBTAIN AN ARCHITECTURAL <br />DIRECTIVE IN CASE OF ANY CONFLICT. REFER TO ARCHITECTURAL <br />DRAWINGS FOR DIMENSIONS NOT SHOWN IN STRUCTURAL DRAWINGS, <br />CONCRETE AND REINFORCING: <br />1. ALL CONCRETE WORK SHALL CONFORM TO THE LATEST ACI "BUILDING <br />CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI-318". <br />2. ALL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE <br />STRENGTHS AS INDICATED BELOW: <br />CONCRETE MAX WATER TYPE <br />STRENGTH CEMENT RATIO AGGREGATE LOCATION USED <br />3000 PSI 0.52 STONE CONCRETE U.N.O. <br />3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, NEW BILLET <br />STEEL, DEFORMED BARS, CONFORMING TO ASTM A-615, GRADE 60. <br />ALL BARS SHALL BE SECURELY SUPPORTED AND WIRED IN PLACE. <br />PRIOR TO POURING CONCRETE. ALL REINFORCING STEEL TO BE WELDED <br />SHALL CONFORM TO ASTM A-706. <br />4. ALL WELDED WIRE FABRIC (W.W.F.) IN FLAT SHEETS ONLY AND SHALL <br />CONFORM TO ASTM A-185. <br />5. UNLESS NOTED, ALL BARS MARKED CONTINUOUS SHALL BE SPLICED AT <br />ALL LAP POINTS AND CORNERS AND DEVELOPED AT NON -CONTINUOUS <br />ENDS AS PER TYPICAL DETAILS. SPLICE CONTINUOUS TOP BARS AT <br />CENTER BETWEEN SUPPORTS AND SPLICE CONTINUOUS BOTTOM BARS <br />AT SUPPORTS. <br />6. CONCRETE COVER FOR REINFORCING BARS SHOWN IN TYPICAL DETAILS. <br />7. UNLESS NOTED, TEMPERATURE REINFORCING (ASTM A-615-60) TO BE <br />0.0018 X CONCRETE AREA. <br />8. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED JUST <br />BEFORE PLACING NEW CONCRETE IN ACCORDANCE WITH THE BUILDING <br />CODE. <br />9. CONTRACTOR SHALL COORDINATE PLACEMENT OF, OR BOX OUT FOR, <br />ALL PIPE SLEEVES, OPENINGS, ETC, REQUIRED FOR VARIOUS TRADES. <br />10. CONTRACTOR SHALL COORDINATE AND NOTIFY OTHER TRADES IN <br />SUFFICIENT TIME TO ALLOW THEM TO SET ANCHORS, INSERTS, BOLTS, <br />HANGERS, ETC., AS REQUIRED FOR THEIR USE. <br />11. UNDER NO CIRCUMSTANCES SHALL CONCRETE BE PUMPED THROUGH <br />ALUMINUM PIPES. CONCRETE SHALL NOT BE PLACED IN CONTACT WITH <br />ALUMINUM, ALUMINUM MIXING DRUMS, TRUCK MIXERS, BUGGIES, <br />CHUTES, CONVEYORS, TREMIE PIPES, AND OTHER EQUIPMENT MADE OF <br />ALUMINUM SHALL NOT BE USED ON THIS PROJECT. <br />12. SLUMPS OF OVER 4 INCHES WILL NOT BE PERMITTED UNLESS THE <br />HRWR ADMIXTURE (SUPER PLASTICIZER) IS USED. MAXIMUM SLUMP IS <br />THEN 8 INCHES UNLESS OTHERWISE DIRECTED BY THE ENGINEER. <br />13. NO ADMIXTURE SHALL BE USED IN CONCRETE EXCEPT WITH THE <br />PERMISSION OF THE ENGINEERS AND AFTER LABORATORY DESIGN MIX <br />APPROVAL. ALL ADMIXTURES SHALL CONTAIN NO MORE CHLORIDE IONS <br />THAN ARE PRESENT IN MUNICIPAL DRINKING WATER. <br />14. WATER REDUCING ADMIXTURE SHALL CONFORM TO THE ASTM C-494, <br />TYPE A, AND SHALL BE USED IN ALL CONCRETE. <br />15. AIR ENTRAINING ADMIXTURE SHALL CONFORM TO ASTM C260. AIR <br />CONTENT OF CONCRETE SHALL BE USED AS FOLLOWS: <br />A. FOR CONCRETE EXPOSED TO SOIL AND/OR WEATHER, 5%. <br />B. FOR INTERIOR WALLS, COLUMNS, AND SLABS, 3%. <br />20. FLY ASH - ASTMC618, TYPE C OR TYPE F SHOULD BE USED BUT NOT <br />TO EXCEED 20% CEMEN1111OUS CONTENT. <br />21. ALL EXPOSED CONCRETE SLABS SHALL RECEIVE A CURING COMPOUND. <br />THE CURING COMPOUND SHALL CONFORM TO ASTM C309 AND SHALL <br />HAVE 30% SOLIDS MINIMUM. WATER/BLANKET CURING AS PER ACI <br />RECOMMENDATION MAY BE USED AS ALTERNATE. <br />GENERAL STRUCTURAL NOTES <br />SETTLEMENT NOT TO EXCEED 1/8 CONTRACTOR MUST CONTACT A <br />GEOTECHNICAL ENGINEER TO DO A SOIL EXPLORATION WHICH MUST <br />INCLUDE BORINGS AT A MINIMUM RATE OF ONE FOR EVERY 3000 <br />SQUARE FOOT OF BUILDING BUT NOT LESS THAN TWO BORINGS, THE <br />BORINGS MINIMUM DEPTH SHOULD BE TWENTY FIVE FEET (25'-0") OR <br />TWICE THE LARGEST DIMENSION OF THE LARGEST FOUNDATION WHICH <br />EVER IS GREATER, THESE REQUIREMENTS MAYBE MODIFIED AT THE <br />DISCRETION OF THE GEOTECHNICAL ENGINEER. A REPORT SIGNED AND <br />SEALED BY A PROFESSIONAL GEOTECHNICAL ENGINEER MUST BE <br />SUBMITTED TO MICE PRIOR TO ANY FOUNDATION WORK, <br />2. FILL AND SUBGRADE PREPARATION SHALL BE AS NEEDED TO OBTAIN <br />THE SAFE BEARING PRESSURE INDICATED ON NOTE 1. ALL ORGANICS <br />AND UNSUITABLE SOIL SHOULD BE REMOVED AND A MINIMUM OF 98% <br />MUST BE OBTAIN UNLESS GEOTECHNICAL ENGINEER RECOMMENDATIONS <br />ALLOW A LOWER PERCENT OF COMPACTION. <br />3. ALL COLUMN FOOTINGS SHALL BE CENTERED UNDER COLUMN <br />CENTERLINES UNLESS OTHERWISE NOTED. <br />4. BACKFILLING AGAINST FOUNDATION WALLS SHALL BE DONE CAREFULLY <br />WITH SMALL COMPACTION EQUIPMENT, AFTER SLABS ON GROUND ARE <br />IN PLACE AND CONCRETE HAS SET, NO TRUCKS, BULLDOZERS, ETC. <br />SHALL BE ALLOWED CLOSER THAN 6'-0" TO ANY FOUNDATION WALL. <br />ANY WALL 3'-0" OR HIGHER MUST BE BRACED DURING THE <br />CONSTRUCTION PROCESS. <br />5. NO FOUNDATIONS SHALL BE PLACED ABOVE 1 VERTICAL ON 2 <br />HORIZONTAL SLOPES EXTENDED FROM THE CLOSEST EDGE OF ANY <br />UNDISTURBED SOIL OR OTHER FOUNDATION STRUCTURE. BOTTOM OF <br />FOOTINGS SHALL NOT BE LESS THAN 1'-0" BELOW EXISTING GRADE <br />(U.N.O.). <br />6. FOR FOUNDATIONS SIZE AND REINFORCING SEE SCHEDULE. <br />7. CONTRACTOR SHALL TREAT SOIL BENEATH BUILDING FOR TERMITES. <br />WOOD FRAMING NOTES: <br />1. ALL WOOD FRAMING SHALL BE IN COMPLIANCE WITH THE LATEST NDS <br />EDITION FOR WOOD CONSTRUCTION. DIMENSIONED LUMBER SHALL BE <br />DRESSED S4S, AND SHALL BEAR THE GRADE STAMP OF THE <br />MANUFACTURER'S ASSOCIATION. <br />2. ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WARP. <br />3. ALL FRAMING LUMBER SHALL BE SOUTHERN YELLOW PINE #2 OR <br />BETTER. <br />4. INTERIOR NON -LOAD BEARING WALLS SHALL BE UTILITY GRADE OR <br />BETTER. <br />5. MINIMUM OF 3-PLY STUD COLUMNS TO BE INSTALLED AT BEAM OR <br />GIRDER TRUSS BEARING LOCATIONS UNLESS NOTED OTHERWISE. <br />6. INSTALL BLOCKING IN ALL WALL STUDS OVER 8'-0" AT MID -HEIGHT, <br />AND SHEATHING JOINT. BRACE GABLE END AT 4'-0" O.C. AS SHOWN <br />IN THE DRAWINGS. <br />7. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE <br />PRESSURE TREATED OR OF NATURAL DURABLE WOOD. <br />8. PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH AN <br />APPROVED TREATMENT IN ACCORDANCE WITH F.S. 11-W-571 AND <br />BARE THE AMERICAN WOOD PRESERVES INSTITUTE EQUALITY MARK <br />LP-2. <br />9. SHEATHING SHALL BE APA EXTERIOR GRADE RATED, AND INSTALLED <br />WITH PLY -CLIPS AT 24" O.C. SEE NAILING SCHEDULE FOR SHEATHING <br />CONNECTION. <br />10. FLOOR SHEATHING SHALL BE A MINIMUM OF 5/8" TONGUE AND <br />GROOVE TYPE SUPPORTED AT 24" O.C. MAX, UNLESS NOTED <br />OTHERWISE IN PLAN. <br />11. ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE <br />OF TIMBER CONSTRUCTION REQUIREMENTS. ALL NAILS EXPOSED TO THE <br />EXTERIOR SHALL BE GALVANIZED. <br />12. ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED BY <br />SIMPSON STRONG TIE OR APPROVED EQUAL. SUBMIT CUT SHEETS FOR <br />ALL CONNECTION HARDWARE TO ENGINEER FOR APPROVAL. ALL NAIL <br />HOLES SHALL BE FILLED OR AS REQUIRED BY THE MANUFACTURER TO <br />ACHIEVE LOAD CAPACITY. <br />13. BRACING: TEMPORARY BRACING OF THE ROOF SYSTEM SHALL BE <br />INSTALLED PER HIB-91 RECOMMENDATIONS AND SHALL BE UTILIZED AS <br />THE PERMANENT BRACING FOR THE ROOF SYSTEM, UNLESS NOTED <br />OTHERWISE. <br />14. ALL WOOD FRAMING SHALL BE IN COMPLIANCE WITH THE LATEST NDS <br />EDITION FOR WOOD CONSTRUCTION. <br />STRUCTURAL STEEL: <br />1. ALL STRUCTURAL STEEL WORK SHALL BE FABRICATED AND ERECTED IN <br />ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS. <br />2. STRUCTURAL STEEL SHALL CONFORM TO: <br />WIDE FLANGE (WF) ASTM A992 (50 KSI) <br />SHAPES (L,T,C,PL) ASTM A36 <br />STRUCTURAL TUBE (HSS) ASTM A500 (46 KSI) <br />ANCHOR BOLTS ASTM F1554 (36 KSI) U.N.O. <br />IN PLANS, OR SECTIONS. <br />FRAMING BOLTS ASTM A325 OR A490 <br />WELDING ELECTRODES E70XX <br />3. ALL HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM SPECIFICATION <br />A325 AND SHALL BE PROVIDED WITH HARDENED WASHERS UNDER THE <br />TURNED ELEMENT (NUT OR BOLT HEAD). <br />4. INSTALLATION AND TIGHTENING OF ALL HIGH STRENGTH BOLTS SHALL <br />CONFORM TO THE "SPECIFICATION FOR STRUCTURAL JOINTS USING <br />ASTM A325 OR A490 BOLTS". <br />5. SHOP CONNECTIONS MAY BE WELDED OR HIGH STRENGTH BOLTED. ALL <br />BOLTS SHALL BE 3/4" DIAMETER MINIMUM. ALL CONNECTIONS SHALL <br />CONFORM TO THE TYPICAL CONNECTION DETAILS SHOWN ON THE <br />PLANS UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. <br />6. ALL FIELD CONNECTIONS SHALL BE BOLTED WITH HIGH STRENGTH <br />BOLTS, SLIP -CRITICAL (FRICTION) TYPE EXCEPT WHERE SLOTTED HOLES <br />ARE SPECIFIED OR WHERE MOVEMENT OF THE CONNECTED MEMBERS IS <br />EXPECTED. IN THESE CASES PROVIDE OVERSIZED WASHER, HAND <br />TIGHTEN BOLTS, AND TACK WELD WASHER TO NUT TO VERIFY <br />ASSEMBLY IS HELD TOGETHER. <br />7. ALL WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY <br />CODE, ANS01.1, ALL WELDING SHALL BE PERFORMED USING E70XX <br />U.N.O. <br />8. CUTS, HOLES, COPINGS, ETC. REQUIRED IN STRUCTURAL STEEL <br />MEMBERS FOR THE WORK OF OTHER TRADES SHALL BE SHOWN IN THE <br />STRUCTURAL STEEL SHOP DRAWINGS AND SHALL BE MADE IN THE <br />SHOP. HOLES SHALL BE REINFORCED AS REQUIRED BY THE ENGINEER. <br />9. BURNING OF HOLES, CUTS, ETC. IN STRUCTURAL STEEL MEMBERS IN <br />THE FIELD WILL NOT BE PERMITTED, EXCEPT WITH THE SPECIFIC <br />APPROVAL OF THE ENGINEER. <br />10. ALL STEEL MEMBERS EXPOSED TO WEATHER (SUCH AS LINTELS, DOOR <br />JAMBS, ETC.) SHALL BE GALVANIZED. <br />11. FOR MISCELLANEOUS STEEL, SEE ARCHITECTURAL DRAWINGS. <br />12. ANY STEEL MEMBERS REQUIRED BY THE ELECTRICAL OR MECHANICAL <br />TRADES FOR THE SUPPORT OF THEIR EQUIPMENT, WHICH ARE NOT <br />SHOWN ON ARCHITECTURAL OR STRUCTURAL DRAWINGS, SHALL BE <br />PROVIDED BY THE TRADE REQUIRING SUCH SUPPORT. <br />13. SEE SPECIFICATIONS FOR PAINTING OF STRUCTURAL STEEL. ALL <br />FABRICATION AND ERECTION MARKS SHALL BE COVERED DURING FIELD <br />TOUCH-UP PAINTING.. <br />15. DESIGN CONNECTIONS FOR THE MAXIMUM SHEAR (V IN KIPS) LISTED IN <br />THE TABLES FOR "ALLOWABLE UNIFORM LOADS IN KIPS FOR BEAMS <br />LATERALLY SUPPORTED" AT THE BOTTOM OF EACH PAGE IN THE <br />"PROPERTIES AND REACTION VALUES", PART 2 OF THE LATEST EDITION <br />OF THE AISC "MANUAL OF STEEL CONSTRUCTION". PROVIDE SIGNED <br />AND SEALED DRAWINGS AND CALCULATIONS BY A PROFESSIONAL <br />ENGINEER. <br />16. DESIGN BASE PLATE ANCHOR BOLTS FOR LATERAL MEMBERS USING <br />FORCES INDICATED IN DRAWINGS. PROVIDE SIGNED AND SEALED <br />DRAWINGS AND CALCULATIONS BY A PROFESSIONAL ENGINEER. <br />POST -INSTALLED ANCHORS <br />1. POST -INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED <br />ON THE CONSTRUCTION DOCUMENTS. SPECIAL INSPECTIONS (ARE/ <br />ARE NOT) REQUIRED PER THE PROVISIONS SET FORTH BELOW. <br />CONTRACTOR TO CONTACT MANUFACTURER'S REPRESENTATIVE FOR <br />PROPER PRODUCT INSTALLATION TRAINING ON INITIAL ANCHORS. <br />2. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE <br />SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO <br />THE ENGINEER -OF -RECORD ALONG WITH CALCULATIONS THAT ARE <br />PREPARED & SEALED BY A REGISTERED PROFESSIONAL ENGINEER. <br />THE CALCULATIONS SHALL DEMONSTRATE THAT THE SUBSTITUTED <br />PRODUCT IS CAPABLE OF ACHIEVING THE PERTINENT EQUIVALENT <br />PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING <br />THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS <br />REQUIRED BY THE BUILDING CODE. <br />3, EXPANSION ANCHORS SHALL BE STUD TYPE WITH A SINGLE PIECE <br />OF THREE SECTION WEDGE AND ZINC PLATED IN ACCORDANCE WITH <br />ASTM B633. THE ANCHORS SHALL MEET FEDERAL <br />SPECIFCATIONFF-S-325, GROUP II, TYPE 4, CLASS I FOR CONCRETE <br />EXPANSION ANCHORS. ANCHORS SHALL BE HILTI KWIK BOLT II AS <br />SUPPLIED BY HILT] INC. TULSA OKLAHOMA. ANCHORS SHALL BE <br />INSTALLED IN HOLES DRILLED WITH HILT) CARBIDE TIPPED DRILL BITS <br />OR MATCHED TOLERANCE DIAMOND CORE BITS. ANCHORS SHALL BE <br />INSTALLED IN ACCORDANCE WITH MANUFACTURE'S <br />RECOMMENDATIONS. <br />4. INJECTED ADHESIVE ANCHORS SHALL BE USED FOR INSTALLATION OF <br />THREADED RODS. ADHESIVE SHALL BE FURNISHED IN A SIDE BY SIDE <br />REFILL PACK WHICH KEEP COMPONENT A AND B SEPARATE. <br />INJECTION ADHESIVE SHALL BE HILTI HIT HY 150 AS SUPPLIED BY <br />HILT] INC. TULSA OKLAHOMA. ANCHOR RODS MEET ASTM F1554 (36 <br />KSI). NUTS AND WASHERS SHALL BE FURNISHED TO MEET THE <br />REQUIREMENTS OF AN ASTM F1554 (36 KSI) STEEL ROD. <br />PRE-ENGINEERED WOOD PRODUCTS: <br />1. ALL PRE-ENGINEERED WOOD PRODUCTS SHALL BE VERIFIED BY TRUSS <br />MANUFACTURER. TRUSS MANUFACTURER SHALL HAVE THE AUTHORITY <br />TO MAKE SUBSTITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS <br />DUE TO AVAILABILITY OR ECONOMICS. CHANGES SPECIFIED BY THE <br />TRUSS MANUFACTURER SHALL CONTROL. CHANGES MADE AFTER TRUSS <br />ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD, MUST BE <br />APPROVED BY THE ENGINEER OF RECORD. <br />2. FRAMING PLAN IS DIAGRAMMATIC IN NATURE AND IS PROVIDED FOR <br />ILLUSTRATION PURPOSES ONLY. TRUSS MANUFACTURER TO PROVIDE <br />SEPARATE LAYOUT AND TRUSS COMPONENT DESIGN SIGNED AND <br />SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER. <br />3. ALL PRE-ENGINEERED WOOD PRODUCTS ARE THE RESPONSIBILITY OF <br />THE TRUSS MANUFACTURER. THE TRUSS ENGINEER IS A DELEGATED <br />ENGINEER FOR THIS PROJECT, AND AS SUCH, IS RESPONSIBLE FOR THE <br />VALIDITY OF THE COMPONENTS PROVIDED. FRAMING LAYOUTS SHOWN <br />MAY BE CHANGED BY THE TRUSS MANUFACTURER. THE DELEGATE <br />ENGINEER IS RESPONSIBLE FOR PROVIDING A FINAL SEALED SET OF <br />ALL CALCULATIONS AND LAYOUTS FOR THIS PROJECT TO THE ENGINEER <br />OF RECORD FOR REVIEW PRIOR TO MANUFACTURE OF SAID <br />COMPONENTS. ENGINEER OF RECORD HAS NOT REVIEWED THE <br />PRE-ENGINEERED TRUSS MANUFACTURER'S COMPONENTS AT THIS 11ME <br />AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER SUCH <br />INFORMATION HAS BEEN PROVIDED FOR REVIEW. CONTRACTOR, AS <br />PROJECT COORDINATOR, SHALL BE RESPONSIBLE FOR INSURING <br />INFORMATION REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER <br />OF RECORD IN A TIMELY MANNER WHEN AVAILABLE. <br />4. ALL PRE-ENGINEERED TRUSSES TO BE DESIGNED USING THE MOST <br />RECENT TPI CRITERIA. TRUSSES TO BE HANDLED AND INSTALLED USING <br />MOST RECENT HIB RECOMMENDATIONS. TEMPORARY AND PERMANENT <br />BRACING SHALL BE IN ACCORDANCE WITH BCSI 1-03 <br />RECOMMENDATIONS UNLESS NOTED OTHERWISE, OR MORE STRINGENT <br />CODE REQUIREMENTS APPLY. TRUSS ENGINEER IS RESPONSIBLE FOR <br />INDICATING ALL TRUSS TO TRUSS CONNECTORS, ALL COMPONENTS TO <br />BE DESIGNED FOR BOTH GRAVITY AND UPLIFT LOAD CASES, INCLUDING <br />BEAM COMPONENTS. <br />5. UPON REVIEW, ENGINEER OF RECORD WILL PROVIDE A REVIEW LETTER <br />INDICATING ANY CHANGE IN STRAPPING OR SUPPORT BASED ON THAT <br />REVIEW. CONSTRUCTION COMMENCING PRIOR TO ENGINEER'S REVIEW IS <br />SUBJECT TO MODIFICATION BASED ON REVIEW LETTER. <br />SHOP DRAWINGS: <br />1. NO STRUCTURAL DRAWINGS SHALL BE REPRODUCED FOR USE AS SHOP <br />DRAWINGS. <br />2. ALL DIMENSIONAL COORDINATION SHALL BE DONE BY THE CONTRACTOR <br />AND/OR HIS DETAILER. <br />3. DETAILER SHALL CHECK ALL ARCHITECTURAL AND MECHANICAL <br />DRAWINGS FOR ALL ATTACHMENTS, CLIPS, OPENINGS, OR DUCT WORK <br />AFFECTING STRUCTURAL MEMBERS. ALL ITEMS SHALL BE SHOWN ON <br />SHOP DRAWINGS. <br />4. ALL SHOP DRAWINGS SHALL BE SUBMITTED ON TRANSPARENCIES FOR <br />DIRECT REPRODUCTION WITH THREE PRINTS ONLY. DISTRIBUTION AS PER <br />ARCHITECT INSTRUCTIONS. <br />5. PROVIDE SUFFICIENT SPACE ON SHOP DRAWINGS NEAR TITLE BOX <br />(ABOUT 40 SQUARE INCHES) FOR STAMPS AND ENGINEERS COMMENTS. <br />6. THE SHOP DRAWINGS SHALL BEAR INITIALS OF DETAILER'S CHECKER <br />AND CONTRACTOR PRIOR TO SUBMISSION. <br />7. COMPLETED ERECTION PLANS SHALL BE SUBMITTED PRIOR TO OR IN <br />CONJUNCTION WITH DETAIL DRAWINGS. BUT IN NO CASE SHALL DETAIL <br />DRAWINGS BE SUBMITTED PRIOR TO ERECTION PLANS. <br />8. DETAILER SHALL SUBMIT AN INDEX OF THE DETAIL DRAWINGS WITH <br />EACH SHOP DRAWING SUBMITTAL. <br />9. SHOP DRAWINGS NOT COMPLYING WITH ALL THE ABOVE ITEMS SHALL <br />BE RETURNED FOR CORRECTIONS WITHOUT PROCESSING. <br />10. RESUBMITTED SHOP DRAWINGS SHALL HAVE THE FOLLOWING CHANGES <br />INCORPORATED: FIRST RESUBMISSION TO HAVE LETTER "A" ADDED TO <br />DRAWING <br />A. NUMBER AND ANY CHANGES MARKED ON THE DRAWING <br />MARKED 1 AT EACH ITEM CHANGED. ALL ITEMS TO BE NOTED IN <br />REVISION BOX. <br />B. SUBSEQUENT RESUBMISSION SHALL BEAR CHANGES "B" AND 2 <br />AND 3 ETC. AS IN 11A. <br />11. CONTRACTOR SHALL HAVE SHOP DRAWINGS WHICH HAVE BEEN <br />SATISFACTORILY REVIEWED BY THE ARCHITECT AND/OR ENGINEER AND <br />CONFIRMED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY <br />WORK. <br />12. DETAILER SHALL USE THE SAME STRUCTURAL ELEMENT NUMBER IN HIS <br />DETAILS AS THOSE SHOWN ON CONTRACT DRAWINGS. <br />13. SHOP DRAWINGS FOR ALL STRUCTURAL ELEMENTS SHOULD BE <br />SUBMITTED TO MICE WITH A MINIMUM TIME TO BE REVIEWED OF 10 <br />WORKING DAYS, IN CASE OF A LARGE SUBMITTAL OR MORE THAN ONE <br />SUBMITTAL FOR THE SAME PROJECT, AN ADDITIONAL WORKING DAY IS <br />REQUIRED FOR EVERY 5 DRAWINGS/SHEETS OVER 30 <br />DRAWINGS/SHEETS, THE TIME INDICATED ABOVE IS FOR MICE REVIEW <br />ONLY, CONTRACTOR MUST INCLUDE ENOUGH TIME FOR DELIVERY. <br />ARCHITECTURAL REVIEW, AND OWNERS REVIEW AND WORK THIS 11ME IN <br />THE PROJECT SCHEDULE AS NEEDED, <br />14. THERE SHALL BE NO DEVIATION FROM THESE CONSTRUCTION <br />DOCUMENTS, IF ANY CHANGES ARE PROPOSED BY THE CONTRACTOR <br />OR THE PROVIDER OF THE SHOP DRAWINGS. THEY SHOULD BE CLEARLY <br />INDICATED, SIGNED AND SEALED DRAWINGS AND CALCULATIONS BY <br />FLORIDA PROFESSIONAL ENGINEER MUST BE PROVIDED. ANY CHANGES <br />WITHOUT PROPER DOCUMENTATION INDICATED ABOVE WILL RESULT IN <br />SOME REVISIONS BY THE ENGINEER OF RECORD AND/OR ARCHITECT, <br />THE COST FOR THESE REVISIONS INCLUDING ENGINEER AND <br />ARCHITECTURAL FEES SHALL BE PAID BY THE CONTRACTOR, <br />`\`���.....�lllt <br />`'� 0A �• Cgsl��11 <br />No • �Z i <br />43453 <br />ATE OF • �= <br />ARMANDO A. CASTELLON, �.E ���`•••'�< p R pP•' <br />FL. LIC. No. 43453 rt�+1 �O •A 1•••��G+. <br />MASTER""'�`� <br />CONSULTING <br />ENGINEERS, INC. <br />STRUCTURAL CONSULTANTS <br />5523 WEST CYPRESS ST., #200 <br />TAMPA, FLORIDA 33607 <br />813.287.3600 FAX 813.287.3622 <br />www.mcenginwa.com <br />THIS DRAWING AND ALL IWDRMA71ON CONTAINED HEREIN IS THE SOLE PROPERTY <br />OF MISTER CONSULTING ENGINEERS, INC. AND MAY NOT BE REI RDDUCED, <br />CORED, ALTERED OR USED IN ANY WAY WTMOUT THE O REM WRITTEN <br />AUTHORIZATION FROM MASTER CONSULTING ENGRE"", INC. <br />CA: 8426 PROJ NO. 1001-000 <br />© COPYRIGHT 2013 <br />THE COMMONS <br />ON PRETTY POND <br />38130 Pretty Pond Road <br />Zeph yrh it l s, FL 33540 <br />i ie cc��1Nt��s <br />110/15/13 I PERMIT SET <br />8/30/13 DESIGN DEVELOPMENT SET <br />Mark I Date <br />scriaiion <br />Issue/Revision <br />Revision <br />Project ID <br />13016 <br />CAD File Name <br />S1.1 GENERAL STRUCTURAL NOTES <br />Drawn By <br />JW <br />Reviewed By <br />HK <br />Plot Date: <br />10/11 /2013 <br />Record Date: <br />10/10/2013 <br />Sheet Title <br />General Structural Notes <br />Drawing No. <br />SHEET SCALE: NTS <br />5 <br />4 <br />3 <br />2 <br />1 <br />S1.1 <br />